PROIETTA ARCHILED RGB User manual

!
!
INSTRUCTION MANUAL"
"
ARCHILED RGB
WARNING:"
Read this instruction manual carefully before using the
projector!
Thank you for choosing a PROIETTA product#

INDEX
•SAFETY INFORMATION!
•TECHNICAL SPECIFICATIONS!
•PRODUCT INTRODUCTION "
1.1. PRODUCT FEATURES"
1.2. QUICK START"
1.3. DATA TRANSFER BETWEEN DIFFERENT UNITS (HOST - SLAVE)"
1.4. MULTIPLE UNITS SYNCHRONIZATION !
•MODE OF OPERATION"
2.1. MAIN MENU"
2.1.1. BASIC USAGE"
2.1.2. KEYPAD LOCK "
2.2. MENU STRUCTURE "
2.3. MENU DESCRIPTION"
2.3.1. STATIC MODE (STAT) "
2.3.2. AUTO MODE (AUTO) "
2.3.3. DMX AND SLAVE (RUN) "
2.3.4. DMX ADDRESS CODE (dMX) "
2.3.5. DMX512 CHANNEL MODE (PERS) "
2.3.6. ID ADDRESS CODE (Id)"
2.3.7. SCENE EDITING (EdIT)"
2.3.8. NATIVE SETTING (SET)"
2.3.9. WHITE BALANCE SETTING (CAL1)"
2.3.10. COLOR CORRECTION SETTING (CAL2)"
2.3.11. KEY PROTECTION SETTING (KEY)"
1!
2!
3!
3!
4!
5!
5!
6!
6!
6!
6!
6!
9!
9!
10!
10!
11!
11!
12!
12!
13!
14!
15!
15!

2.4. DMX CONSOLE OPERATION "
2.4.1. CHANNEL TABLE"
2.4.2. COLOR CHANGING TABLE"
2.4.3. DIMMING SPEED TABLE!
•DEFAULT CUSTOM PROGRAMS!
•WARRANTY!
•DECLARATION OF CONFORMITY!
•DISPOSAL OF UNUSED PRODUCT!
!
2
15!
15!
18!
18!
19!
22!
23!
23!

SAFETY INFORMATION
Read the following security information carefully before performing any operations. The
product described in this manual is a lighting fixture for projecting a light beam into
outdoor environments.!
Any other use is not provided by the manufacturer and therefore relieves him of any
liability for damages arising from misuse.!
The only maintenance operation allowed in warranty is the replacement of the lamp. Any
other repairs must be carried out solely by the manufacturer, who denies any
responsibility for unauthorized interventions.!
Always disconnect the projector from the outlet before any maintenance operation. The
risk of electric shock if you disassemble the projector or some of its parts. !
For reliable operation of the device, the ambient temperature must be between -25°C
(-13°F) and 45°C (113°F).!
Do not place objects on the power cable and in case of damage to the manufacturer for
replacement in order to avoid dangers of electrocution.!
Do not look at the beam of light to avoid damaging your eyes.!
Never place the projector on flammable and/or combustible surfaces.!
Never touch the projector or its components with wet hands.!
1

TECHNICAL SPECIFICATIONS
!
MODEL
ARCHILED RGB
POWER SUPPLY
SUPPLY VOLTAGE
AC 100-240 V
ELECTRICAL FREQUENCY
47-63 Hz
LED
54 LED (18 R, 18G, 18B)
NOMINAL POWER
98 W
NUMBER OF COLORS
16.000.000
LIFETIME
50.000 h
CONTROLS
Menu 4 buttons (4-digit display); DMX 512; Master/Slave
IP (Protection rating)
IP66
MINIMUM AMBIENT TEMPERATURE
-25 °C
MAXIMUM AMBIENT TEMPERATURE
45 °C
WEIGHT:
7 Kg
DIMENSIONS:
See the drawings below (dimensions in mm)
2

PRODUCT INTRODUCTION
1.1 PRODUCT FEATURES
OPERATING MODE:
1. External Control Mode!
!
- DMX512 (console control, with five different DMX channel modes available);"
- Master-Slave control.!
2. Auto Mode!
!
Built-in programs:"
"
- color-fade (gradient) and color-pulse (fading to black) effects"
"
- Strobe effect with custom variable speed (from slow rate to very fast-paced)
available in external control mode or standalone use (static color plus strobe or strobe
plus color gradient effect programming custom scenes)"
"
Internal programming to customize automatic mode programs:"
"
- programming function: do not need the console to program and change the gradient
speed between the scenes or colors used by each of the ten programs (in any
combination with the strobe effect, up to thirty scenes per program)"
"
- program data can be exchanged between different units (host-slave) !
3. Static Mode!
!
It’s possible to select any fixed color without the use of the console (also assign the
strobe effect and vary its speed)!
STAGE MODE: BLACK-OUT CONTROL FROM CONSOLE AND ID ADDRESS CODE
In STAG mode, when predefined and custom programs run, if the value of the overall
brightness adjustment channel is set to zero the light will be completely attenuated. The
program will continue to work automatically (it can be restored at any time by moving the
appropriate cursor up on the console). Despite the result being the same, it is actually
different from setting all channels to 0 using the Black-Out button dedicated, available on
almost all DMX controllers."
In STAG mode, a series of lights with the same DMX address (up to 66 units) can be
indexed with a different ID and independently controlled to achieve various effects."
3

NON-LINEAR DIMMING AND LINEAR DIMMING SPEED
Operating at 16 bits (up to 65,535 different levels of intensity available) it is possible to
achieve and set non-linear curves to increase the smoothness of the dimming.!
White Balance!
Different preset balances can be saved and reused with different color temperature
corrections.!
Color correction
It is possible to correct the RGB balance by changing the maximum values for each
channel.!
Screen lock and password protection
The display will automatically turn offafter 30 seconds if no key is pressed (just press any
button and release it to turn the display back on): the menu panel can also be password
protected to prevent any unauthorized changes.!
1.2 QUICK START
SETTING UP OPERATING MODES:
The main menu normally runs "External Control" Mode: unless it’s been selected
"Automatic" Mode, "Static" Mode, or "Slave" Mode. Therefore if SLAV or one of the
default or custom programs (selected during previous use) appears on the display on
power on, the unit will wait to receive an external DMX signal on the selected address,
and will not emit any light until this happens.!
The default mode is the DMX512 (to use a DMX console): while receiving a standard
DMX512 signal the point after the fourth decimal point will flash. If it does not flash,
please check if the console (or any other DMX512 signal source) is properly connected
and transmitting:!
•if you want to change the value of the DMX address, press the MENU button until you
see dMX and press the ENTER button to access the sub-menu (this allows to set the
starting DMX address pressing UP and DOWN);!
•If you want to select the DMX channel mode, press the "MENU" key until you see PERS
and press the "ENTER" key to enter the submenu (refer to pages 15-18 to see a
detailed channel chart for each mode);!
•There are 5 different dimming speed (increasing the “softness“ of the dimming) to
choose from: while in the SET menu press “UP” or “DOWN” until dIM appears on the
display and press “ENTER” to access the sub-menu (refer to page 18 for details).!
If you want to use the Master-Slave control, enter the RUN menu and select SLAV for all
the units that must be chained as slaves to the master one which should be set to STAT
or AUTO mode.!
Please note: do not set up more than one Master unit per DMX chain. It’s necessary that
there is only one signal source (Master unit or DMX console) for each line. In case there
are multiple sources the signal would interfere, preventing the correct reception of data.!
4

To select the Static Mode: enter the STAT menu by pressing ENTER from the main menu
and choose the color by setting the RGB values (after setting the color also the strobo
speed can be set, see more at page 9).!
•To select the Auto Mode: enter the AUTO menu by pressing ENTER from the main menu
and choose a standard built-in program (AT.01-AT.10) or a custom program (PR.01-PR.
10). To edit them refer to page 10.!
1.3. DATA TRANSFER BETWEEN DIFFERENT UNITS
It’s possible to transfer program data between different units by sending data from a
Master used as a host to one or more connected as Slave.!
The copied values are all custom programs (pR.01-pR.10) that can be edited using the
EDIT menu to create their scenes (see page 12 and 19).!
To start the transfer, select UPLd from the SET menu of the Master used as Host (host the
programs to transfer to Slave units) and press ENTER (see page 13 for more details).!
1.4 MULTIPLE UNITS SYNCHRONIZATION
When a DMX console controls a number of units, you can simultaneously send DMX
values to the various addresses selected for each device.!
DMX data conversion is done individually by each one of the connected units.!
Please note:!
1. in some circumstances, units may be out of sync at startup (due to inconsistencies in
startup times or abnormal behavior due to data packet leaks). If this happens, move
the DMX channel cursor relative to the incorrect value, setting it first to zero and then
to the desired value;"
2. since the crystal frequency of each headlight is not exactly the same, after a long time
running the same program, there may be delays between the headlights, resulting in
phase-out phenomena. To avoid that result there are two different approaches:"
"
- use a console to simultaneously launch programs by selecting them through their
DMX channel or by programming their console scenes after properly assigning DMX
addresses (refer to the console manual);"
"
- use the Master-Slave control to synchronously run, on all Slave units, the program
set on the first unit of the chain (Master).!
If you are using different models of ArchiLED at the same time, with different LED
configurations (RGB, RGBW, RGBAL…), the Master has to be the one with most
channels (RGBW>RGB not vice versa). In this way the signal is correctly
recognized by all units.!
In addition, the Master has to be properly programmed in one of the "Static"
modes or by editing one of the pR.01-pR.10 programs in order to use only the
channels common to all Archiled used.!
5

MODE OF OPERATION
2.1. MAIN MENU
2.1.1 BASIC USAGE
Select main menu or return to the previous menu when in a sub-menu!
Enter or select sub-menu/function!
Select previous menu tool or parameter increasing!
Select next menu tool or parameter decreasing!
2.1.2. KEYPAD LOCK
The default password sequence to unlock keys is: UP-DOWN-UP-DOWN, then press
ENTER. To unlock, press and release the UP button, followed by down, press and release
the UP button again, press DOWN and release it, finally press ENTER to confirm.!
2.2 MENU STRUCTURE
STAT R.000
G.000
d.000
ST.00
6
(0-255)!
(0-255)!
(0-255)!
(0-20)
MENU!
ENTER!
UP!
DOWN

AUTO AT.01
AT.10
PR.01
PR.10
RUN dMX.
SLAV.
dMX d.001
PERS STAG
ARC.1
AR1.d
HSV.
Id Id.01
7
(1-512)!
(1-66)!

EdIT PR.01 SC.01 R.000
G.000
PR.10 SC.30 b.000
ST.00
T.000
F.000
SET UPLd.
REST.
Id OFf.
ON.
RGb OFF.
ON.
POW. HIGH
NORM
dIM. OFF.
dIM1.
dIM2.
diM3.
dIM4.
8
(0-255)!
(0-255)!
(0-255)!
(0-20)!
(0-255)!
(0-255)!

CAL1 WT.01 R.000
G.000
WT.11 b.000
CAL2 RGb R.255
G.255
b.255
KEY OFF.
ON.
2.3 MENU DESCRIPTION
2.3.1 STATIC MODE (STAT)
STAT R.000
G.000
b.000
ST.00
9
(0-255)!
(0-255)!
(0-255)!
(25-255)!
(25-255)!
(25-255)!
(0-255)!
(0-255)!
(0-255)!
(0-20)!

To access the static color mode press the MENU button until STAT appears on the
display.!
Press ENTER button to choose the color entering the submenu and setting the values for
the red, green, blue LEDs brightness and eventually to activate the strobe (0 = OFF, 01-20
= ON, with increasing frequency).!
Press UP/DOWN buttons to increase (or decrease) the value; then press ENTER to switch
to the next parameter.!
Press MENU button to return to the main menu.!
2.3.2 AUTO MODE (AUTO)
AUTO AT.01
AT.10
PR.01
PR.10
To run standard and custom programs press MENU until AUTO appears on the display.!
Press ENTER button to enter the sub-menu and choose the desired program by pressing
UP or DOWN button.!
Press MENU button to return to the main menu.!
2.3.3 DMX AND SLAVE (RUN)
RUN dMX.
SLAV.
10

The RUN menu allows the user to choose if the light source is going to be a Master or a
Slave unit.!
Press ENTER button and choose the desired mode by pressing UP or DOWN button:!
•dMX represents “External Control” mode. The light source receives a standard DMX512
signal from a DMX source or run as standalone (selecting AUTO or STAT modes);!
•SLAV represents the Slave mode: only the host signal is received from the Master unit.!
Press MENU button to return to the main menu.!
2.3.4 DMX ADDRESS CODE (dMX)
dMX d.001
To set the DMX starting address for the current unit press MENU until dMX appears; then
press ENTER to set the desired address having choosen the desired value by pressing UP
or DOWN button.!
Press MENU button to return to the main menu.!
2.3.5 DMX512 CHANNEL MODE (PERS)
PERS STAG.
ARC.1
AR1.d
AR1.Sù
HSV.
To set the DMX channel mode press MENU until PERS appears.!
Press ENTER button and choose the desired mode by pressing UP or DOWN button.!
For specific channel modes description please refer to “Channel Table” on page 15.!
Press MENU button to return to the main menu.!
11
(1-512)!

2.3.6 ID ADDRESS CODE (Id)
Id Id.01
To set a different ID for each headlight press MENU until ID appears.!
Press ENTER button and choose the desired ID by pressing UP or DOWN button.!
Press MENU button to return to the main menu.!
2.3.7 SCENE EDITING (EdIT)
EdIT PR.01 SC.01 R.000
G.000
PR.10 SC.30 b.000
ST.00
T.000
F.000
To set the custom programs enter the scene editing mode press MENU until EdIT
appears and then press ENTER to access the sub-menu.!
Choose the program to edit by pressing UP or DOWN button, select it by pressing
ENTER. Select the scene you want to edit and then press ENTER to scroll through the
scene parameters by changing them with Up or DOWN buttons (T = overall scene time, F
= fade time between consecutive scenes).!
12
(1-66)!
(0-255)!
(0-255)!
(0-255)!
(0-20)!
(0-255)!
(0-255)!

2.3.8 NATIVE SETTING (SET)
SET UPLd.
REST.
Id OFf.
ON.
RGb OFF.
ON.
POW. HIGH
NORM
dIM. OFF.
dIM1.
dIM2.
diM3.
dIM4.
To change the setting of the unit entering the native setting mode press MENU until SET
appears.
UPLd is intended to transfer programming data between units: just press ENTER and than
proceed entering password confirmation: UP, DOWN, UP, DOWN followed by ENTER.
If the transfer is successful the Master Archiled first turns yellow, indicating that the data
are in the process of transfer (the progress of upload is displayed). After the transmission
is completed, the lights turns green.
Slave units, similarly, emit yellow light when receiving and turns green after the
transmission in completed. If the light remains yellow then the reception failed: in this case
please restart again.
13

REST is used to restore the default settings: press ENTER button followed by the
sequence: UP, DOWN, UP, DOWN; then press ENTER again to confirm (custom programs
are not overwritten).
Id is used to enable the same function: press ENTER button followed by UP or DOWN
button to choose ON or OFF to enable/disable the ID address function.
RGb is used to activate color cast correction switch settings: press ENTER button followed
by UP or DOWN button to choose ON or OFF to enable/disable the color cast correction
switch settings.
POW allows to choose between NORM (33% = 1 W) e HIGH (100% = 3 W) power mode.
Please consider to avoid HIGH power mode if projecting steady colors at full values.
Static colors with values around 255 may reduce the lifespan of the single LEDs if
kept it on at HIGH power for a long time.
dIM is a non-linear dimming speed setting (refer to “dimming speed table” at page 18).
It uses the 16-bit operating control board to gradually smooth, with different curves, the
dimming speed of the LEDs.
2.3.9 WHITE BALANCE SETTING (CAL1)
CAL1 WT.01 R.000
G.000
WT.11 b.000
To set the white balance presets press MENU until CAL1 is displayed. !
Press ENTER button followed by UP or DOWN buttons to choose one of the proposed
programmes. To modify Red, Green and Blue values press ENTER button repeatedly to choose
the value to modify and UP/DOWN to set it.!
Please note:!
when DMX channel mode is set on STAG, channel 6 can be used to select one of these programs
(WT.01 - WT.11).!
14
(0-255)!
(0-255)!
(0-255)!

2.3.10 COLOR CORRECTION SETTING (CAL2)
CAL2 RGb R.255
G.255
b.255
To set the color correction setting press MENU until CAL2 is displayed, then press ENTER button.
Press ENTER button repeatedly to choose the value to modify and UP/DOWN to set it.!
2.3.11 KEY PROTECTION SETTING (KEY)
KEY OFF.
ON.
Lock the keys to prevent unwanted changes. Press MENU until KEY is displayed, then press
ENTER and UP/DOWN to select ON (or OFF to turn it off).!
2.4 DMX CONSOLE OPERATION
2.4.1 CHANNEL TABLE
A total of five DMX channel modes are available: !
STAG, ARC.1, AR1.d, AR1.S, HSV.
STAG (default)
CHANNEL
DATA
CONTROL FUNCTION
1
0-255
Dimming (master intensity level)
2
0-255
Red (when CH.7 chooses PR.01-10, CH.2 controls Time (reference: Edit Menu
page 12)
3
0-255
Red (when CH.7 chooses PR.01-10, CH.3 controls Fade Time (reference: Edit
Menu page 12)
4
0-255
Blue
5
0-9
No change in color
10-255
Color change mode (reference: “Color Changing Table” page 18)
6
0-9
No strobe effect
10-255
Strobe speed
15
(25-255)!
(25-255)!
(25-255)!

7
0-40
No program
41-70
Built-in program At.01
71-80
Built-in program At.02
…
(Each decade represents a program)
151-160
Built-in program At.10
161-170
Custom Program PR.01
…
(Each decade represents a program)
241-220
Custom Program PR.09
251-255
Custom Program PR.10
8
0-255
Built-in program speed (to adjust a custom program speed use CH2, CH3)
9
0-255
Dimming speed (reference: “Dimming Speed Table” page 18)
10
0-9
ID address is invalid (no ID)
10-19
ID1
…
(Each decade represents an ID)
200-209
ID20
210
ID21
211
ID22
…
(Each number represents an ID)
254
ID65
255
ID66
CHANNEL
DATA
CONTROL FUNCTION
16

ARC.1
AR1.d
AR1.S
HSV
CHANNEL
DATA
CONTROL FUNCTION
1
0-255
Red
2
0-255
Green
3
0-255
Blue
4
0-255
Dimming speed (reference: “Dimming Speed Table” page 18)
CHANNEL
DATA
CONTROL FUNCTION
1
0-255
Dimming (master intensity level)
2
0-255
Red
3
0-255
Green
4
0-255
Blue
5
0-255
Dimming speed (reference: “Dimming Speed Table” page 18)
CHANNEL
DATA
CONTROL FUNCTION
1
0-255
Dimmer (master intensity level)
2
0-255
Red
3
0-255
Green
4
0-255
Blue
5
0-9
No change in color
10-255
Color change mode (reference: “Color Changing Table” page 18)
6
0-9
No strobe effect
10-255
Strobe speed
7
0-255
Dimming speed (reference: “Dimming Speed Table” page 18)
CHANNEL
DATA
CONTROL FUNCTION
1
0-255
H (tone 0-100%)
2
0-255
S (saturation 0-100%)
3
0-255
V (intensity 0-100%)
4
0-255
Dimming speed (reference: “Dimming Speed Table” page 18)
17
Table of contents
Other PROIETTA Projector manuals