Proteco Q45 new User manual

Q45_new_2018
Q45new
PROTECO S.r.l. Via Neive, 77 - 12050 Castagnito (CN) ITALY Tel. +39 0173 210111 - Fax +39 0173 210199 [email protected] - www.proteco.net
230V ac
Instructions Manual
CONTROL PANEL 230V
FOR ROLLING SHUTTERS
Control panel for electric rolling shutters – 230Vac
• Built-in radio receiver 433Mhz
• Adjustable pause time for automatic closing function
• Adjustable working time
• Output for safety photocells or safety edges
• Output for safety flashing light connection
• It can be connected to a timer-clock for pre-set time opening and closing
TECHNICAL FEATURES
Item code PQ45
Control Panel Dimensions 98x98x45 mm
Box dimensions 110x150x70 mm
Radio reciver In-built, 433Mhz
Main Power 230Vac ~ 50Hz
Current in stand-by mode 3 W
Main fuse 230V (F2) 5 A
Accessory fuse 24V (F1) 1.6 A
Blinker power supply 24 Vac, max 10 W
Courtesy light 24 Vac, max 10 W – still light for 90 seconds
Working time Adjustable, up to 120 seconds
Pause time for automatic closing Adjustable from 5 to 120 seconds
Working temperature -20 +50 °C

1 Q45
PROTECO S.r.l. Via Neive, 77 - 12050 Castagnito (CN) ITALY Tel. +39 0173 210111 - Fax +39 0173 210199 [email protected] - www.proteco.net
1. WARNINGS
WARNING: This manual contains important information concerning personal safety.
An incorrect installation or an improper use may lead to severe injuries.
Read carefully and pay particular attention to the safety sections marked by the symbol .
Store this manual safely for future use.
Do not allow children or pets near your electric rolling shutter. Never let children operate or play with the controls.
Keep the remote controls away from children and unauthorised users.
All wirings or operations on the control panel must be performed with the control panel disconnected from the
power supply.
Connect the control panel only to a power supply line equipped with safety grounding system.
Means for disconnections must be incorporated in the fixed wiring in accordance with the wiring rules and wiring diagram
Wiring, settings and commissioning of this control board must be carried out by qualified and experienced personnel only.
The installation has to comply to laws and regulations in force.

Q45 2
PROTECO S.r.l. Via Neive, 77 - 12050 Castagnito (CN) ITALY Tel. +39 0173 210111 - Fax +39 0173 210199 [email protected] - www.proteco.net
TR3
K2
K3
F2
RL1
JP4 JP3 JP1
P1 P2 P3
J3
F1
SET WORK BREAK
5A-250V
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
DL1
SW1
CAPACITOR
NEUTRAL
Main components description
F1 = Accessories protection fuse 24V, 1.6A
F2 = Main power and motor protection fuse 230V, 5A
J3 = Radio receiver
DL1 = Control panel’s status LED
SW1 = Programming dip-switches block
SET = Control panel Programming key
WORK = Working time adjustment key
BREAK = Pause time setting key for automatic closing
2. WIRING DIAGRAM
Polarity in main power supply line connection
must always be respected
(plug 1= Neutral, plug 2 = Phase).
Minimum wire-section size for 230Vac outputs
(motors and light) is 1.5mm²
Always use separate wires for accessories and
controls wiring (24V) to avoid disturbances or
damages caused by synchronous generated
voltage. Do not use only one multi-core cable
for wiring.
In case of wirings longer then 50m, we recom-
mend to decouple the command circuits by
using suitable relays on main electric board.
2. ELECTRIC WIRINGS
1 - 2 = MAIN POWER 230Vac ~ 50Hz
1 Neutral
2 Line
6 - 7 = FLASHING LIGHT. Blinking signal
FLASH 24Vac, max 10W
3 - 4 - 5 = MOTOR output. Max 700W.
3 Neutral
4 Open
5 Close
8 - 9 = PHOTOCELLS output 24Vdc. Max 500 mA
8 Positive
2 Negative
9 - 10 = STOP command (NC contact).
STOP Always stops the motor.
If the stop command is given during the
pause time, automatic closing will be
disabled.
9 – 11 = CLOSING command (NO contact).
9 – 12 = OPENING command (NO contact).
9 – 13 = START command (NO contact).
Step-by-step mode (open, stop, close)
9 – 14 = CLOSING PHOTOCELL input (NC contact).
Active only when closing
(stops and reopens).
15 - 16 = AERIAL terminal block
15 aerial EARTH
16 aerial SIGNAL
9 – 13 = CLOCK Timer input (NO contact).
To enable pre-set open/close timing
CLOSING
OPENING
BLINKING
LINE
NEUTRAL
CLOSING
OPENING
SIGNAL wire
EARTH wire

3 Q45
PROTECO S.r.l. Via Neive, 77 - 12050 Castagnito (CN) ITALY Tel. +39 0173 210111 - Fax +39 0173 210199 [email protected] - www.proteco.net
4. PROGRAMMING
4.1 WORKING MODE setting
Use SW1 dip-switches to select the working mode.
While setting SW1 dip-switches make sure that the control panel is not powered (main power supply disconnected).
SW1 ON OFF
1 “Hold-to-run” working mode:
•OPEN command: opens as long as the key is holded
pressed, if released the motor stops
•CLOSE command: closes as long as the key is holded
pressed, if released the motor stops
•START command = step-by-step mode (open, stop, close)
2COURTESY LIGHT mode (90 seconds)
Standard working mode:
• OPEN command: complete opening only
• CLOSE command: complete closing only
• START command = step-by-step mode
(open, stop, close)
BLINKING flashing light mode
4.2 WORKING TIME adjustment
4.2.1 WORKING TIME adjustment – WITHOUT opening delay
1) Close the rolling shutter and power the control panel on.
Then press SET key once: DL1 will flash to confirm that the control panel is now on programming mode.
2) Press once WORK key on the control panel: motor will start running.
3) When the rolling shutter is completely open wait for a few seconds more (maximum 7) and then press WORK
key again. The motor will stop running and after few seconds it will automatically close.
Closing time will be equal to opening time.
4) Once the motor has completed the closing it will stop and the control panel will automatically exit from the
programming mode. DL1 light stops blinking and stays on still.
To further changes to the working times, please repeat the above procedure.
4.2.2 WORKING TIME adjustment – WITH opening delay
Opening delay is recommended in case of several control panes wired in series to avoid over-loadings.
1) Close the rolling shutter and power the control panel on.
Then press SET key once: DL1 will flash to confirm that the control panel is now on programming mode.
2) Press and hold WORK key on the control panel as long as you want to set the opening delay and then release
the key. The motor will start running
3) When the rolling shutter is completely open wait for a few seconds more (maximum 7) and then press WORK
key again. The motor will stop running and after few seconds it will automatically close.
Closing time will be equal to opening time.
4) Once the motor has completed the closing it will stop and the control panel will automatically exit from the
programming mode. DL1 light stops blinking and stays on still.
To further changes to the working times, please repeat the above procedure.
4.3 AUTOMATIC CLOSING adjustment
1) Close the rolling shutter and power the control panel on.
Then press SET key once: DL1 will flash to confirm that the control panel is now on programming mode.
2) Press BREAK key once: the control panel starts counting the pause time for the automatic closing (minimum 5
seconds)
3) Once the suitable pause time has been reached press again BREAK key on the control panel.
The pause time is now saved and the control panel will automatically exit from the programming mode.
DL1 light stops blinking and stays on still.
To further changes to the pause time, please repeat the above procedure.
TRANSMITTER'S COMMAND ALWAYS WORKS AS START IMPULSE (NO DEAD-MAN SETTING)

Q45 4
PROTECO S.r.l. Via Neive, 77 - 12050 Castagnito (CN) ITALY Tel. +39 0173 210111 - Fax +39 0173 210199 [email protected] - www.proteco.net
To disabled the AUTOMATIC CLOSING function, please follow the procedure here below:
1) Close the rolling shutter and power the control panel on.
Then press SET key once: DL1 will flash to confirm that the control panel is now on programming mode.
2) Press and hold BREAK key on the control panel until DL1 light stops blinking and stays on still.
Now release the key, the control panel automatically exits form the programming mode.
DL1 light remains on still.
4.4 RADIO CODING
The control panel can store up to 10 different radio codes.
Please follow this procedure to save a radio code on the control panel:
1) Close the rolling shutter and power the control panel on.
Then press SET key once: DL1 will flash to confirm that the control panel is now on programming mode.
2) Press and hold the remote control’s key until DL1 light stops blinking and stays on still.
3) The radio code is now stored and the control panel will automatically exit from the programming mode.
DL1 light stops blinking and stays on still.
Please follow the same procedure to store further radio codes (maximum 10).
To delete all radio codes previously stored, please follow the procedure here below:
1) Close the rolling shutter and power the control panel on.
Then press and hold the SET key on the control panel until DL1 light turns off (about 10 seconds)
2) Now release SET key: DL1 will turn on again and stays still.
All radio codes have been deleted and the control panel returns to stand-by mode.
5. COMMISSIONING and TROUBLE-SHOOTING
Once all electrical and safety devices have been wired (push buttons, photocells, flashing light, etc.) power the
control panel and make sure that DL1 light is on.
If it is not, please:
- Check main power supply wiring on terminals 1 and 2;
- Check for burnt fuses and, if needed, replace them with same capacity new ones
Check the motor working keeping in mind that the control panel will perform opening as first movement.
If not used, Normally Closed contacts (for photocells and stop-button) need a jumper to plug 9 (common).
Instruct end-user about the controls and correct use of the electric shutter.
Also inform end-users about safety devices and danger involved when using the automation.
Fill in the technical file for the installation and fulfill any obligations required by regulations in force.
6. DISPOSAL
Do not pollute the environment
Some electronic components may contain polluting substances.
Ensure materials are passed to the authorised collection centres, according to the laws and the regulations on
force, for safe disposal.

CE COMPLIANCE DECLARATION
Manufacturer: PROTECO S.r.l.
Address: Via Neive, 77 – 12050 Castagnito (CN) – ITALIA
declares that
The product type:Q45 NEW electronic controller for rolling ers, 230V
Models: MQ452
Is built to be integrated into a machine or to be assembled with other machinery to crate a machine under
provisions of 2006/42/EC Machinery Direve.
It complies with the essenal requirements of EEC Direcves:
2006/95/EC Low VoltageDirec�ve
2004/108/EC Electromagne�c Compa�bility Direc�ve
R&TTE 99/5 Radio & Telecommunica�ons Terminal Equipments Direc�ve
The manufacturer declares that the start-up ofthe machinery isnot unless the machine, inwhich
the product is incorporated or of which is becoming a component, has beenideed and declaredas
conformed to2006/42/EC Machinery Direve.
Nn
Castagnito, July 14th 2018
Marco Gallo
Managing Director
This manual suits for next models