5. External Output Control Function Description
CN 1
Start signal output
START
1.When (CN1+CN2) is closed, the screw driver then start running.
2.When (CN1+CN2) is open, the screw driver then stop running.
This pin refers to the START signal connection negative end
CN 3
Brake signal output
BRAKE
1.When (CN3+CN4) is closed, BRAKE is displayed.
2.When (CN3+CN4) is open, there is no output status.
This pin refers to the BRAKE signal connection negative end
CN 5
signal output
1.When (CN5+CN6) is closed, the screw driver then start reverse rotation.
2.When (CN5+CN6) is open, the screw driver then stop reverse rotation.
This pin refers to the Reverse signal connection negative end
fastening a screw
1.When (CN7+CN8) is closed, OK is displayed.
2.When (CN7+CN8) is open, there is no output status.
This pin refers to the OK signal connection negative end
CN 9
When error operation,
NG is displayed
1.When (CN9+CN10) is closed, NG is displayed.
2.When (CN9+CN10) is open, there is no output status.
This pin refers to the NG signal connection negative end
CN 11
or job sequence
completed, OKALL is
1.When (CN11+CN12) is closed, OKALL is displayed.
2.When (CN11+CN12) is open, there is no output status.
This pin refers to the OKALL signal connection negative end
CN 13
Vdc
Positive DC voltage
terminal
This pin is to provide the external positive voltage.
CN 14
Negati
This pin is to provide the external negative voltage.
※Remarks:
1. INPUT contact, if using non-isolating (wet contact) control, it needs to connect a 10K resistor in series on the line.
2. When the automatic machine is installed, it is recommended to install the signal line on the machine and then
connects to KL-WSCBSN.
When working with automatic control, pay attention to the above items to prevent equipment damage.
6. CONFIRM Mode
Code Description Remarks
C1 External GATE signal trigger once CONFIRM mode. External GATE signal trigger once
C2 External GAT E signal trigger twice CONFIRM mode. External GATE signal trigger twice
C3 When enable “Stop Mode AS” function, LCM screen will
display “C3” when OKALL.
panel key/external switch CONFIRM key
C4 When enable “Stop Mode AS” & “Gate Mode_Once”
function, LCM screen will display “C4” when OKALL.
External GATE signal trigger once + panel
key/external switch CONFIRM key
C5 When enable “Stop Mode AS” & “Gate Mode_Twice”
function, LCM screen will display “C5” when OKALL.
External GATE signal trigger twice + panel
key/external switch CONFIRM key