Pure Air Essentials Works COOL MIST Installation instructions manual

COOL MIST
Luxury Ultrasonic Humidifier
IMPORTANT INSTRUCTIONS — RETAIN FOR FUTURE USE

Congratulations on your purchase of the Pure Air Essentials Works COOL MIST Luxury
Ultrasonic Humidifier. Please read the instructions and safety tips before use. Your
humidifier comes with a 2-year warranty. If for any reason you need service, please
call 800-520-6000.
Components
Specifications
Humidifying Mode: Ultrasonic Cool Mist
Power Supply: 100-240V, 50Hz
Power Consumption: <25W
Tank Capacity: 4.5L (4.75 Quarts)
Moisture Output: 300ml/h (10 oz./h)
Dimensions: 8”L x 8”W x 10”H
Weight: Approximately 2.16 lbs.
2

How to Operate
SET UP
Select a firm and flat location at least six inches from any wall or object for proper air flow. Place
humidifier on a water-resistant surface, as water can damage furniture and some flooring. Do
not place directly on carpet, towels, blankets or other absorbent surfaces. We do not accept
responsibility for damage caused by water spillage.
FILLING
Make sure unit is unplugged.
1. Separate the tank from
the base of the unit.
3. Pour cool, clean water
directly into the tank.
(Works best with purified
or distilled water.)
2. Flip over water tank and
open the tank lid, turning it
to the left.
4. Close the tank lid, turning it
to the right. It is important
to FIRMLY secure cap after
filling the tank with water.
5. Attach tank to base of unit.
6. Before turning on make sure there is water in the unit.
3

How to Operate
FUNCTIONS AND FEATURES
A. ON/OFF and Low Water Level Indicator
Press button A to turn the humidifier ON and OFF. When the humidifier is low on water, the
LED indicator light on the body will change from blue to red, and the unit will shut off. Add
water to continue use.
B. Mist Output Setting
Press button B to set the low, medium and high mist output
C. Night Light
Press button C to turn light ON/OFF.
D. Timer Setting
Press button D to determine the operating time. It can be set to 2, 4 or 8 hours or for
continuous operation.
E. Sleep Mode
Press button E to turn off all the lights after the light flashes 3 seconds.
Mist Director
The mist director can be rotated 360 degrees by manually turning the spout.
Cleaning Brush
The humidifier includes a cleaning brush that should be used to keep the ultrasonic disk free
from dust and debris.
Humidifier Tank
When the humidifier water tank is removed from the body of the unit, the power automatically
shuts off.
4

Maintenance
Always unplug the unit before servicing in any way.
GENERAL CLEANING
• Inside the base of the unit. Pour excess water out of the unit. Wash out the unit with fresh
water using the cleaning brush and a soft cloth as needed. Do not submerse the base of the
unit into water, or allow water to enter inside the dry air exhaust port of the unit.
• Water tank. Empty water tank. Remove mist nozzle and clean the mist tube with fresh water
and a light brush (bottle cleaning brush is recommended).
• Outer surface of the unit. Wipe the surface of the unit with a soft, damp cloth if needed.
If you notice an accumulation of water during usage, reduce humidity and dry outer surface
with a cloth.
• Ultrasonic Disk.
Remove the tank and empty all the water in the base and tank.
Locate the ultrasonic disk on the inner center of the base unit. USE ONLY THE ENCLOSED
CLEANING BRUSH to gently clean disk and remove build up and deposits. No other
cleaning tool should be used. Do not scrub or scrape the ultrasonic disk.
DE-SCALING
• As water types differ and for your health, cleaning or scale removing (if present) may be
required weekly or every other week to optimize unit performance.
If scale becomes difficult to remove with brush:
1. Make a cup of mixture by adding 1 tsp. of white vinegar and 1 tsp. of water.
2. Let solution stand for 5 minutes.
3. Pour the mixture into the base, clean all interior surfaces with a soft cloth or brush to help
remove scale.
5

STORAGE
• Follow the maintenance instructions when the humidifier will not be use for a long period.
• Dry the humidifier completely before storing. DO NOT store with water inside base or
water tank.
• Pack the unit in its original box and store in a cool, dry location.
NOTE: IF YOU EXPERIENCE A PROBLEM, DO NOT ATTEMPT TO OPEN THE MOTOR
HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE
TO THE HUMIDIFIER OR PERSONAL INJURY.
Precautions
Failure to comply with the warnings listed may result in electric shock or serious injury.
• This product should be used only in accordance with the specifications outlined in this
manual. Usage other than what has been specified here may result in serious injury.
• CAUTION: To reduce the risk of severe burns, keep this product out of the reach of children
and pets.
• Disassembly, repair or remodeling by an unauthorized person may result in serious harm and
will void the manufacturer’s warranty.
• Always place this humidifier on a flat surface. It may not work properly on uneven surface.
• Do not place this product on cloth, carpet or a soft surface. This may block air inlet.
• This product releases mist. Do not place it directly on wood furniture, floor or any surfaces
that could be damaged by water. Manufacturer does not accept any liability for damage in
the case of the unit being placed incorrectly.
• Do not use if the plug is damaged or loose.
• Before filling or cleaning the unit, make sure it is unplugged.
• Once the humidifier has been plugged in, do not tilt or move the unit.
• Do not remove the water tank from the unit while it is on.
• Do not handle the plug with wet hands.
• Do not excessively bend, twist, pull or damage the power cord.
• Avoid placing this product where the spout is pointed directly at an object or person.
• Do not inhale the mist/vapor expelled from the product or drink water from the tank.
• Do not fill the water tank with hot or boiling water.
• Do not use this product in direct sunlight or near a heat source such as a stove, heater or
radiator.
• If the water tank becomes cracked or damaged, do not use.
• Do not keep this product running for an extended period of time.
• Unplug the cord when unit is not in use for an extended period of time and/or when not one
is home.
• Do not keep water in the tank when not in use for an extended period of time.
• Do not clean the unit, water tank or water reservoir with detergents or chemicals of any kind.
• The use of water additives including ethereal/essential oils, fragrances, eucalyptus, water
conditioners, etc. will damage the appliance materials and as a consequence the whole unit.
Any use of such additives will void the manufacturer’s warranty.
• Do not use this product near any other electronic device.
• Do not cover the spray spout at any time during use. Do not put anything on or in the tank.
• IMPORTANT: Neither humans nor animals can hear the high frequency vibrations.
6

• When unplugging from outlet hold humidifier securely.
• Do not place cord over objects.
• Do not get water in or on the power cord or where it connects to the product. Do not use
near a sink.
• Do not touch the water tank during operation.
• Do not submerse the unit in water or pour water on the unit or in the humidity spout.
• When emptying water from water tank, pour on drain side.
• Do not cover the spout with cloth or hand and do not use without the spout.
• Use clean or distilled water in tank. Hard water areas will require more frequent cleaning.
Troubleshooting
Please refer to the table below in the event the product is operating abnormally.
Problem Solution
Water vapor and humidity Power plug: Unplug and then try again.
are not produced.
Power failure: When power is returned, try again.
Tank installation: Make sure the tank is correctly attached.
The surface of the ultrasonic disk is dirty: Clean ultrasonic
disk.
Air blows but water vapor Excessive water: Remove a certain amount of water
is not produced. from the tank.
Detergent residue and/or oil ingredients from cosmetics,
etc. may be in tank; wash out tank and try again.
The surface of the ultrasonic disk is dirty: Clean ultrasonic
disk.
If you use hard water, replace with softer water.
Humidity level is low. The surface of the ultrasonic disk is dirty: Clean ultrasonic
disk.
The water in the unit is too cold: Replace with cool water.
The humidity has a bad Poor maintenance or dirty water: Clean the product
smell. thoroughly, and fill it with fresh water.
White dust is forming on Hard water may deposit a certain kind of dust. Dust in the
nearby furniture. air also settles because of added humidity in the room.
Use distilled water if this becomes a nuisance.
7

8
Item #308798
pureessentialoilworks.com • 800.520.6000
tng worldwide • New Hudson, MI 48165
©2018 TNG • Made in China
Problem Solution
Unit has stopped working. No or low water. Unplug unit and refill tank.
Water is accumulating Saturation of humidity. Lower mist control setting.
outside of unit or area
surrounding unit. Unit not level and water is accumulating. Unplug and
place on level surface.
Point spray away from objects. Raise unit on a water-
resistant level surface 2-3 feet off of floor.
Water dripping when Water remaining on bottom of tank. Wipe tank or tilt to
refilling. drain before transporting.
Increased noise level. Unit must be placed on a flat, level, hard surface. Make sure
it is NOT place on a soft or absorbent surface.
Red light on power dial. Indicates low water. Unplug and refill tank.
Warranty
Pure Air Essentials Works offers a 2-year warranty for defects only. Not responsible for
unit due to tampering, negligence, dropping, outdoor use or operating near water. If
you experience any issues with the COOL MIST Luxury Ultrasonic Humidifier, please
contact us at 800-520-6000. Do not contact or return to the retailer that you purchased
from. In case of warranty replacement, please have your proof of purchase available.
Product Registration
To ensure your full warranty and to receive product updates and streamlined customer
support, remember to register your product at:
www.pureessentialoilworks.com/registration.
Table of contents