Pure Reliability LAZER 150G User manual

LAZER 150G
PR-5030A
This product manual contains important information about the safe installation and
use of this projector. Please read and follow these instructions carefully and keep this
manual in a safe place for future reference.
PR LIGHTING LTD.
Yingbin Road, Dashi Panyu, Guangzhou, 511430 China
http://www.pr-lighting.com

Laser 100 manual_en.doc
2/21
MAIN FEATURES 3
SAFETY WARNING 4
SAFETY PROTECTION FUNCTIONS 5
SAFE USAGE OF THE PROJECTOR 6
INSTALLING THE PROJECTOR 7
POWER SUPPLY – MAINS 7
OPERATION 8
XLR CONNECTORS AND TERMINATOR 9
DMX512 CONTROL 10
DMX CONTROL CHANNEL FUNCTIONS 11
OPERATIONS FOR DATA REFRESH 17
MAINTENANCE 17
ELECTRICAL DIAGRAM 18
NOTICE 21
Please note that as part of our ongoing commitment to continuous product development, specifications are subject to change
without notice. Whilst every care is taken in the preparation of this manual, we reserve the right to change specifications in the
course of product improvement. The publishers cannot be held responsible for the accuracy of the information herein, or any
consequence arising from them.
Every apparatus is tested completely and packed properly by the manufacturer. Please make sure the packing and / or the
apparatus is in good condition before your installation and use. Should there be any damage caused by transportation, consult
your dealer and do not use the apparatus. Any damage caused by improper use will not be assumed by the manufacturer and /
or dealer.
THESE ITEMS ARE PACKED TOGETHER WITH THE PROJECTOR
Power-cord (1 PCS)
XLR cable with 3-pin plug and socket (1 PCS)
Cable of data refreshes (1 PCS)
CD included this manual (1 PCS)
Laser key (2 PCS)
Urgency laser safety switch + Connector (1 set)
Thank you for purchasing our product LAZER 150, PR-5030A series.
This product manual contains important information about the safe installation and use of this projector.
Please read and follow these instructions carefully and keep this manual in a safe place for future
reference
The LAZER 150 is an innovative projector with an elegant housing, which is made from high intensity
and heat-resistant complex plastic. LAZER 150 complies with CE norms and standards and uses
international protocol DMX 512. The LAZER 150 uses 16 DMX channels. Through DMX 512 controller,
you can select the pictures and their movement changing methods, so you can get charming and
dreamful effect of the various laser pictures. The projector has 3 group of sound activation demo so
makes light and sound uniformity come true. You can get impact effect using the music together. The
unit has reliable safety equipments. Once the errors occur, the unit will be cut off automatically. It is
suitable for application in TV station, discotheque, singing and dancing stage, nightclub, bar, press
conference, exhibition, etc.
The projector uses green solid laser lamp for light source. This series also has PR-5031, PR-5032,
PR-5033, and PR-5034 and so on according to the differences of the power consumption and colour
of their light source. All of the product manuals in the PR-5030A series are same except the
differences of the power consumption and colour.
ACCESSORIES
INDEX
INTRODUCTION

Laser 100 manual_en.doc
3/21
MAIN FEATURES:
1. Professional optical system dustproof technique, so need not periodic clean even if long time
usage.
2. Uses international standard high speed vibratile lens whose scanning speed above 30K, make the
scanning pattern more steady and exquisite.
3. Adopts the latest laser lamp of DPSS.
4. Uses international standard DMX 512 protocol.
5. Laser pictures, picture changing method and picture movement speed can be controlled via DMX
512 controller.
6. Adopts large memory of FLASH to save the pictures. The memory capacity can up to 8Mbit.
7. There are 256 built-in basic pictures and characters, 256 pre-programmed “combination picture
effect”, up to 300,000 kinds of actual light beam effects, 10 set of beautiful animation and 32 user
refreshable graphics.
8. Users can convert the standard ILDA format into the laser pictures, compile program and refresh
the 32 user refreshable graphics inside the unit.
9. The 12-bit resolution of the laser picture makes the pictures clearer.
10. Adopts BLANKING technology to produce verisimilitude images.
11. Has multi-laser safety protection function and can cut off automatically if any error occurs.
12. Has 3 sound activation demo to achieve impact effect, single projector can run under sound
activation without controller.
TECHNICAL DATA
Power supply: 90-220V AC 50Hz, wide voltage
Power consumption: 100W / 220V
Output power: 150mW
Beam length: 532nm, Green
Interface: Control: DMX 512
Refresh data: RS-232
Channels: 16
Dimensions: 411mm LONG x 261mm WIDE x 150mm HIGH
Net weight: 16kg

Laser 100 manual_en.doc
4/21
PR-5030A OUTLOOK
The LAZER 150 PR-5030A belongs to the CLASS III-B laser product, the laser lamp parameter is as
follows:
Maximum output power:150 mW
Beam length: 532 nm, green therefore
Light spot size: <1.2mm
Note of Safety Use 1: because the energy of this kind of laser is strong enough to result in the
permanence injury to persons’ eyes, must avoid see the laser beam directly in use process, especially
the laser beam stops at a spot can cause eye burns seriously.
Note of Safety Use 2: inside of the projector has automatic laser safety protection circuitry. However,
for your safety, it is recommended that install the “Laser urgency switch” in place you can control
conveniently, so that you can turn off the laser manually in case of emergency.
Note of Safety Use 3: for your safety, please do not run the projector when cover is open.
Note of Safety Use 4: please take off the laser key if non-use, in case of other people unfamiliar with
the projector turn it on and then lead to harm.
Note of Safety Use 5: the safety standard in every country and area is different. Please contact local
laser official to know correlative regulations before actual usage of the projector.
SAFETY WARNING

Laser 100 manual_en.doc
5/21
The laser safety protection measures of this product LAZER 150 PR-5030A are implemented
according to the relative European items. These measures are as below:
▲the cover open protection: open the plastic shell if there is current flows, the laser will be cut off
automatically.
▲laser key switch: the laser can be switch on when key is under on circumstance; the key cannot pull
out at the same time.
▲external urgent and safe switch: switch off the laser manually if error occurs.
▲laser indication device: there are laser indication devices at the side of key switch and on the socket,
used to indicate “the laser is ready".
▲laser safety marks: there are marks on the head of the unit at several places comply with the
Europe standard.
AVOI D DI RECT EXPOSURE TO BEAM
I NTERLOCK DEFEATED
I F COVER I S OPENED AND
LASER RADI ATION CALSS 3B
▲the laser safety protection panel: if the laser beam scans in a small spot may have safety-hidden
trouble. The panel will be closed within 25 ms compulsorily.
KEY WORD: LASER SAFETY USAGE
SAFE USAGE OF THE PROJECTOR
SAFETY PROTECTION FUNCTIONS

Laser 100 manual_en.doc
6/21
The following points are important for safety as well as for the smooth
installation and performance of the unit
When unpacking and before disposing of the carton, check there is no transportation damage before
using the projector. Keep the carton well for future possible transportation. Should there be any
damage caused by transportation, consult your dealer and do not use the apparatus.
The projector is for Indoor use only, IP20. Use only in dry locations. Keep this device away from rain
and moisture, excessive heat, humidity and dust. Do not allow contact with water or any other fluids, or
metallic objects.
The projector is not designed or intended to be mounted directly on to inflammable surfaces.
The projector is only intended for installation, operation and maintenance by qualified personnel.
The projector must be installed in a location with adequate ventilation, at least 50cm from adjacent
surfaces. Be sure that no ventilation slots are blocked.
Do not project the beam onto inflammable surfaces, minimum distance is 3m. 3m
Avoid direct exposure to the light from the lamp. The light is harmful to the eye.
Do not attempt to dismantle and/or modify the projector in any way.
Electrical connection must only be carried out by qualified personnel.
Before installation, ensure that the voltage and frequency of power supply match the power
requirements of the projector.
It is essential that each projector is correctly earthed and that electrical installation conforms to all
relevant standards.
Do not connect this device to any dimmer pack.
Make sure that the power-cord is never crimped or damaged by sharp edges. Never let the power-
cord come into contact with other cables. Only handle the power-cord by the plug. Never pull out the
plug by tugging the power-cord.
The projector should always be installed with a secondary safety fixing. A safety cord is supplied for
this and it should be attached as shown in “installing the projector” section.
There are no user serviceable parts inside the projector. Please do not open the housing and never
operate the projector with the covers removed.
Always disconnect from the mains, when the device is not in use or before
cleaning it or before attempting any maintenance work.
If you have any questions, do not hesitate to consult your dealer or manufacturer.

Laser 100 manual_en.doc
7/21
Always ensure that the projector is firmly anchored to avoid vibration and slipping whilst functioning.
Always ensure that the structure to which you are attaching the projector is secure and is able to
support a weight of LAZER 150. For safety, the projector should have a secondary fixing with a safety
chain through the holes on the underside of the unit.
WARNING: The projector should NEVER be lifted or carried by the yoke.
Use the plug provided to connect the mains power to the projector paying attention to the voltage and
frequency marked on the panel of the projector. It is recommended that each projector be supplied
separately so that they may be individually switched on and off.
IMPORTANT
It is essential that each projector is correctly earthed; otherwise, hardware inside the projector may
cause unexpected damage.
INSTALLING THE PROJECTOR
POWER SUPPLY - MAINS

Laser 100 manual_en.doc
8/21
The unit uses standard DMX 512 controller. With the
touch-switches and the digital display screen, DMX start
address can be easily set and the various setup options
may be configured.
The display shows the DMX start address after the
projector is switched on (if you have already set the
DMX start address and saved it, the screen will display
the last setting).
TO SET THE DMX START ADDRESS
Press the UP or DOWN buttons and the display will show the DMX start address.
Confirm your choice by pressing the ENTER button, this will save and set the DMX start address.
The display will show the latest setting each time the projector is powered up.
To control the projector with a DMX controller the DMX start address must be set.
Ensure that none of the Stand-Alone options is set or they will interfere with correct DMX operation.
SETUP OPTIONS - PROJECTOR CONFIGURATION
To browse through the various Setup Options, press the FUNC button consecutively. There are 11
Option codes (1~B), and each code has a specific function. The functions provided are listed in the
following table.
SETUP OPTIONS
CODE CHOICE FUNCTION
N No pan mirror
1 Y Pan mirror
N No tilt mirror
2 Y Tilt mirror
1 Run sound activation demo 1
2 Run sound activation demo 2
3 Run sound activation demo 3
3
N Stop sound activation demo
Y Self test enable
4 N Self test disable
Without DMX512, built-in DEMO program enable
Y Connect DMX512, Run sound activation demo 1, 2,
3, and built-in DEMO program according to music
5
N Built-in DEMO program disable
6 Not used
7 Not used
8 Not used
9 Not used
A Not used
B Not used
When under functional operation, the display format of the digital display screen is:
OPERATION

Laser 100 manual_en.doc
9/21
Once you have selected the desired operation code, press the key UP or DOWN to select “y” (means
ON) or “no “(means OFF). N = NO, Y = YES.
Press the key ENTER to save the selected function and configuration. If the display is showing “y”,
then the setting has been enabled. In the same way, if it was showing “n” when you pressed ENTER
the option has been disabled. The Red LED will flash during this operation.
During function set operation, Green LED will flash one time when press ENTER to indicate the set is
valid. The Red LED will be lit when DMX512 signal is normal.
Note:
1. The codes 3, 4 and 5 should be set “no” When operation.
2. When under sound activation, can use controller to adjust or set 3-Y condition.
3. When use DMX512 controller, codes 4, 5 and 6 should be set “no”.
4. Adjust 1-Y and 2-Y to select suitable display direction according to the actual installation direction.
XLR CONNECTORS
Connection between controller and projector and between one projector and another must be made
with 2 core screened cable, with each core having at least a 0.5mm diameter. Connection to and from
the projector is via cannon 3-pin XLR plugs and sockets which are included with the projector. The
XLRs are connected as shown in the figure above.
Note: care should be taken to ensure that none of the connections touches the body of the plug or
each other. The body of the plug is not connected in any way. The LAZER 150 accepts digital control
signals in standard DMX512 (1990) format.
5-PIN AND 3-PIN CONVERSION
LAZER 150 uses 3-pin XLR plug / socket. If your controller uses 5-pin XLR plug / socket, you should
convert 5-pin plug / socket into 3-pin socket / plug as shown below.
XLR CONNECTORS AND TERMINATOR

Laser 100 manual_en.doc
10/21
DMX TERMINATOR
In the Controller mode or Master/Slave mode, the DMX output has to be connected with a DMX
terminator at the last fixture in the chain. This prevents electrical noise from disturbing and corrupting
the DMX control signals.
The DMX terminator is simply an XLR connector with a 120Ω(ohm) resistor connected across pins 2
and 3, which is then plugged into the output socket on the last projector in the chain. The connections
are illustrated below.
Each LAZER 150 must be given a DMX start address so that the correct projector responds to the
correct control signals. This DMX start address is the channel number from which the projector starts
to “listen” to the digital control information being sent out from the controller. The LAZER 150 has 16
channels, so set the No. 1 projector’s address 001, No. 2 projector’s address 017, No. 3 projector’s
address 033, No. 4 projector’s address 049, and so on.
Certainly, you may use formulation: address = channels x (projector No. –1) +1
For example, for the No. 5 projector’s start address, you should calculate according to formulation: 16
x (5 – 1) +1 =65, so you set the No. 5 projector start address 065. (How to set DMX start address
please refer to “Operation” section.)
Connect the controller’s output to the first fixture’s input, and connect the first fixture’s output to the
second fixture’s input. The rest may be deduced by analogy. Eventually connect the last fixture’s
output to a DMX terminator as shown in the figure below.
DMX512 CONTROL

Laser 100 manual_en.doc
11/21
The LAZER 150 uses 16 DMX channels. They are listed in the following table.
CHANNEL DMX VALUE DESCRIPTION
0-37 Unit OFF
38-74 Unit ON, animation
75-110 Unit ON, geometric picture
111-147 Unit ON, effect
148-184 Unit ON, sound activation 1
185-221 Unit ON, sound activation 2
1
Unit ON/OFF
222-255 Unit ON, sound activation 3
Term explanation:
Animation: a program made by a group of constant pattern.
Geometric picture: static picture, users can edit moving effect via DMX512 controller.
Effect: pictures have had movement parameters, users cannot edit.
The following channels are only for channel 1 value 64-127, animation.
CHANNEL DMX VALUE DESCRIPTION
0-25
Animation 1
26-51
Animation 2
51-76
Animation 3
76-102
Animation 4
102-127
Animation 5
127-153
Animation 6
153-178
Animation 7
178-204
Animation 8
204-229
Animation 9
2
Animation
Selection
229-255
Animation 10
3 Not used
0-25
Animation movement 1 (fastest)
26-51
Animation movement 2
52-77
Animation movement 3
78-103
Animation movement 4
104-129
Animation movement 5
130-155
Animation movement 6
156-181
Animation movement 7
182-207
Animation movement 8
208-233
Animation movement 9
4
Animation movement
234-255
Animation movement 10 (slowest)
0-15
Full range
1/16
16-31
Full range
2/16
32-47
Full range
3/16
48-63
Full range
4/16
64-79
Full range
5/16
80-95
Full range
6/16
96-111
Full range
7/16
112-127
Full range
8/16
128-143
Full range
9/16
144-159
Full range
10/16
160-175
Full range
11/16
176-191
Full range
12/16
192-207 Full range13/16
208-223 Full range14/16
224-239 Full range15/16
5
X Range adjust
240-255
Full range
100%
DMX CONTROL CHANNEL FUNCTIONS

Laser 100 manual_en.doc
12/21
0-15 Full range1/16
16-31 Full range2/16
32-47 Full range3/16
48-63 Full range4/16
64-79 Full range5/16
80-95 Full range6/16
96-111 Full range7/16
112-127 Full range8/16
128-143 Full range9/16
144-159 Full range10/16
160-175 Full range11/16
176-191 Full range12/16
192-207 Full range13/16
208-223 Full range14/16
224-239 Full range15/16
6
Y Range adjust
240-255
Full range
100%
The following channels are only for channel 1 value 128-191, geometric picture. PR-5030A stores 256
static pictures that divided into 16 groups through channel 2 to choose the group number; every group
is made up of 16 pictures and through channel 3 to choose a picture and through other channel to edit
dynamic effect such as zoom in, rotate, move, write, etc. You can also edit static effect such as corner.
CHANNEL DMX VALUE
DESCRIPTION
0-15 Picture group 1
16-31 Picture group 2
32-47 Picture group 3
48-63 Picture group 4
64-79 Picture group 5
80-95 Picture group 6
96-111 Picture group 7
112-127 Picture group 8
128-143 Picture group 9
144-159 Picture group 10
160-175 Picture group 11
176-191 Picture group 12
192-207 Picture group 13
208-223 Picture group 14
224-239 Picture group 15
2
Picture Group
Selection
(16 groups)
240-255 Picture group 16
0-15 Picture 1
16-31 Picture 2
32-47 Picture 3
48-63 Picture 4
64-79 Picture 5
80-95 Picture 6
96-111 Picture 7
112-127 Picture 8
128-143 Picture 9
144-159 Picture 10
160-175 Picture 11
176-191 Picture 12
192-207 Picture 13
208-223 Picture 14
224-239 Picture 15
3
Picture
Selection
(16 pieces)
240-255 Picture 16
4 Not used
5 0-15 Full range1/16

Laser 100 manual_en.doc
13/21
16-31 Full range2/16
32-47 Full range3/16
48-63 Full range4/16
64-79 Full range5/16
80-95 Full range6/16
96-111 Full range7/16
112-127 Full range8/16
128-143 Full range9/16
144-159 Full range10/16
160-175 Full range11/16
176-191 Full range12/16
192-207 Full range13/16
208-223 Full range14/16
224-239 Full range15/16
X Range Adjust
240-255 Full range 100%
0-15 Full range1/16
16-31 Full range2/16
32-47 Full range3/16
48-63 Full range4/16
64-79 Full range5/16
80-95 Full range6/16
96-111 Full range7/16
112-127 Full range8/16
128-143 Full range9/16
144-159 Full range10/16
160-175 Full range11/16
176-191 Full range12/16
192-207 Full range13/16
208-223 Full range14/16
224-239 Full range15/16
6
Y Range Adjust
240-255 Full range 100%
0-15 Pan rotation without direction change
16-31
32-47
48-63
64-79
80-95
96-111
112-127
Normal rotation from slow to fast
128-143 Pan rotation without direction change
144-159
160-175
176-191
192-207
208-223
224-239
7
Pan Rotation
on Sixteen
240-255
Reverse rotation from slow to fast
0-15 Tilt rotation without direction change
16-31
32-47
48-63
64-79
80-95
96-111
112-127
Normal rotation from slow to fast
128-143 Tilt rotation without direction change
144-159
160-175
176-191
192-207
8
Tilt Rotation
on Sixteen
208-223
Reverse rotation from slow to fast

Laser 100 manual_en.doc
14/21
224-239
240-255
0-15 Z rotation without direction change
16-31
32-47
48-63
64-79
80-95
96-111
112-127
Normal rotation from slow to fast
128-143 Z rotation without direction change
144-159
160-175
176-191
192-207
208-223
224-239
9
Z Rotation
on Sixteen
240-255
Reverse rotation from slow to fast
10 Z Initial Angle 0-255 Anti-clockwise 2.8 degrees when move 2 DMX value
0-15 Zoon in and out without change
16-31
32-47
48-63
64-79
80-95
96-111
112-127
Zoon in range from small to large
128-143 Zoon in and out without change
144-159
160-175
176-191
192-207
208-223
224-239
11
Zoom In and Out
on Sixteen
240-255
Zoon out range from small to large
0-127 Normal movement increment increases12
Pan Movement on 128 128-255 Reverse movement increment decreases
0-127 Normal movement increment increases13
Tilt Movement on 128 128-255 Reverse movement increment decreases
0-85 Rotate and zoom in/out round the figure centre
86-171 Rotate and zoom in/out round the picture centre
14
Rotation Centre/Write
3 172-255 Under write circumstance
0-15 Scanning speed is 24K
16-31 Scanning speed is 23K
32-47 Scanning speed is 22K
48-63 Scanning speed is 21K
64-79 Scanning speed is 20K
80-95 Scanning speed is 19K
96-111 Scanning speed is 18K
112-127 Scanning speed is 17K
128-143 Scanning speed is 16K
144-159 Scanning speed is 15K
160-175 Scanning speed is 14K
176-191 Scanning speed is 13K
192-207 Scanning speed is 12K
208-223 Scanning speed is 11K
224-239 Scanning speed is 10K
15
Scanning speed
240-255 Scanning speed is 9K
0-25 Strobe closed
26-51 Strobe 1 (slow)
16
Strobe 52-77 Strobe 2

Laser 100 manual_en.doc
15/21
78-103 Strobe 3
104-129 Strobe 4
130-155 Strobe 5
156-181 Strobe 6
182-207 Strobe 7
208-233 Strobe 8
234-255 Strobe 9 (fast)
Warning: when use DMX512 to control, some of picture under the edit effect
may result in laser safe protection panel moving but without laser projection.
That is the value of channel 4 or 15 is too large or the value of channel 5 or 6 is
too small. Only need to adjust them to a suitable value, the operation will
become normal.
The following channels are only for channel 1 value 192-255, effect selection. PR-5030A stores 256
pieces of “picture combination effect” which have had movement parameter and divided into 16 groups.
Every group has 16 “picture combination effect”, through channel 2 to choose a group and through
channel 3 to choose a “picture combination effect” in the group. “Picture combination effect” is different
from common picture and it is designed specially and cannot be edited.
CHANNEL DMX VALUE DESCRIPTION
0-15 Display picture group 1
16-31 Display picture group 2
32-47 Display picture group 3
48-63 Display picture group 4
64-79 Display picture group 5
80-95 Display picture group 6
96-111 Display picture group 7
112-127 Display picture group 8
128-143 Display picture group 9
144-159 Display picture group 10
160-175 Display picture group 11
176-191 Display picture group 12
192-207 Display picture group 13
208-223 Display picture group 14
224-239 Display picture group 15
2
Display picture
group selection
240-255 Display picture group 16
0-15 Display picture 1
16-31 Display picture 2
32-47 Display picture 3
48-63 Display picture 4
64-79 Display picture 5
80-95 Display picture 6
96-111 Display picture 7
112-127 Display picture 8
128-143 Display picture 9
144-159 Display picture 10
160-175 Display picture 11
176-191 Display picture 12
192-207 Display picture 13
208-223 Display picture 14
224-239 Display picture 15
3
Display picture
selection
240-255 Display picture 16

Laser 100 manual_en.doc
16/21
4 Not used
0-15 Full range1/16
16-31 Full range2/16
32-47 Full range3/16
48-63 Full range4/16
64-79 Full range5/16
80-95 Full range6/16
96-111 Full range7/16
112-127 Full range8/16
128-143 Full range9/16
144-159 Full range10/16
160-175 Full range11/16
176-191 Full range12/16
192-207 Full range13/16
208-223 Full range14/16
224-239 Full range15/16
5
X Range Adjust
240-255 Full range 100%
0-15 Full range1/16
16-31 Full range2/16
32-47 Full range3/16
48-63 Full range4/16
64-79 Full range5/16
80-95 Full range6/16
96-111 Full range7/16
112-127 Full range8/16
128-143 Full range9/16
144-159 Full range10/16
160-175 Full range11/16
176-191 Full range12/16
192-207 Full range13/16
208-223 Full range14/16
224-239 Full range15/16
6
Y Range Adjust
240-255 Full range 100%

Laser 100 manual_en.doc
17/21
1. Connect the power cord and cable of data refresh with the unit, and the other end of the cable of
data refresh connecting with a personal computer. Note: The power must be cut off before this
operation.
2. First, turn on the computer power, and then the unit’s power.
3. Don’t run the data refresh program until the red LED near the unit’s screen is blinking. Set the
computer’s interface of COM1 or COM2 according to the cable of data refresh you have connected.
4. Running LASERDANCE 5.0 software, refer to user manual of relative software.
Note: During transmitting the data, the power of the unit cannot be off; otherwise, some components
inside the unit may be damaged! Wait until appear the dialog box for complete transmitting, and then
you turn off the unit.
5. After turning off the unit’s power, pull the data refresh cable out of the unit. Connect the DMX512
cable to the unit for operation.
6. The data refresh cable is made up of DB9/M and DB9/F plugs and 3 core screened cable as shown
below.
Because the unit is a precise device integrated with optics, mechanism and electronics, please pay
attention to the following points when use the unit normally.
1. When use a fog machine, do not eject the fog to the unit directly, minimum distance is 1m. It is
recommended to use a fan to blow strong fog away from the unit, or to use a dry ice machine to
produce the fog.
2. Please use the special cleaning products in cleaning the optics inside the unit. The operation must
be completed by qualified personnel.
3. The scanner drive PCB and scan head inside the unit are used by couple. They must be changed
together. The operation must be completed by qualified personnel.
OPERATION FOR DATA REFRESH
MAINTENANCE

Laser 100 manual_en.doc
18/21
a) PR-5030A circuit diagram
b) PR-5030A shape
ELECTRICAL DIAGRAM

Laser 100 manual_en.doc
19/21
c) PR-5030A assemblage
d) PR-5030A back nog

Laser 100 manual_en.doc
20/21
Assembly Spec
Item Name Description
1 Main-board ZK4-02 V1.0
2 Reed Switch&Magnet 50V/1A
3 Safe board LASER-SAFE V1.1
4 X-scanner moto /
5 Y-scanner moto /
6 X scanner serve amplifier
board
SCAN-D1 V4.1A
7 Y scanner serve amplifier
board
SCAN-D1 V4.1A
8 Multi-outputs switching
regulator
INAC85~250V OUT±
24V/1A,5V/1A
9 Inter-lock board SAFE-LOCK V1.2
10 Laser power /
11 laser 532nm,150mw
12 EMI Filter 115/250VAC 1A
13 Potentiometer 10KΩ/0.5Wgain adjust
14 Panel socket 3 poles
15 Panel plug 3 poles
16 Key Switch /
17 Laser Emergency Stop
connector
/
18 Laser Standby Redφ3 LED
19 Fan DC 24V/0.15A
20 Data Port DB9/M
21 Display board SZ4-02 V1.0
This manual suits for next models
1
Table of contents
Other Pure Reliability Projector manuals