PRORS
Keyless / Remote Start
Quick Installaon Guide
For Complete Installaon Guide and Technical Support
Visit
www.voxxuniversity.com
Or Call
1-800-225-6074
3 Chirp 4 Chirp 5 Chirp 6 Chirp
1 Lock / Unlock Funcon 500ms 3.5sec 500ms L, DBL UL DBL L, 500ms UL DBL L, DBL UL 500ms L, 350ms UL
2 Ignion Lock OFF ON
3 Ignion Unlock OFF Unlock All
4 Exterior Illuminaon OFF With Arm
With Disarm With Arm & Disarm
5 Auto Relock OFF ON
6 Auto Arming / Locking N/A
7 Nocaon Sound N/A
8 Horn Timing 16ms 30ms
9 Valet Override Method N/A
10 Driver Priority Unlock OFF ON
11 Silent Choice OFF From Transmier
12 Security Prole OFF OEM Security
13 Door Trigger Input Negave Posive
14 Park Light / Trunk Swap OFF ON
15 Data Port Protocol ADS DBI
16 Dome Light Delay Timer OFF / Program 15sec
17 Alarm Trigger Legnth 30sec 45sec 60sec
3 Chirp 4 chirp 5 Chirp 6 Chirp
1 Defrost Output Pulsed 10min
2 RS Start Nocaon ON OFF
3 RS Runme
15min 20min 45min 60min 5min 10min
4 RS Parking Lights Steady Flashing
5 Engine Conrmaon Tach Voltage
6 Voltage Level >0.5v B4 Start <0.5v B4 Start
7 Ignion 2 Output Ignion Accessory
8 Ignion 3 Output Ignion Accessory Start
9 Accessory Output Accessory Ignion
11 Max Crank Time 0.8sec 1.0sec
1.5sec 2.0sec 3.0sec 4.0sec
12 Diesel Delay OFF Diesel 5 Diesel 10
Diesel 15 Diesel 20 Diesel 30
14 Crank Duraon Averaging Preset
15 RS Shock Override Shunt unl Clear Shunt RS Cycle
17 Start Acvaon Two Press One Press
18 RS Lock Funcon No Change UL Before L Aer
UL Before Start Lock Aer Start
19 Factory Disarm Output Single Pulse Double Pulse
350ms 500ms 800ms Same As Bank 2, F1
20 Addional Unlock Pulse No Pulse IGN, ACC, GWR
Negave Output Control (NOC)
AUX Output Control
Negave output control allows any NOC to be programmed for any one of nineteen (19)
opons. This feature is accessible via FlashLogic Weblink or Weblink Mobile.
Any AUX output can congured using the AUX Control Menu. This feature is only
accessible via FlashLogic Weblink or Weblink Mobile.
The Feature Banks below can also be programmed using the FlashLogic Weblink or Weblink Mobile.
Headlight
Defrost
LED
Ch. 4 AUX
Ch. 5 AUX
Ch. 6 AUX
Ch. 7 AUX
REV. B 2020 Voxx Electronics. All Rights Reserved.
Remote Programming
The PRORS does not include an RF remote kit. The RF remote kit Includes two (2) remotes,
one (1) antenna, and one (1) cable. When added, remotes must be programmed to
the system. Remote Programming is located in Feature Bank 1. To enter Remote Auto
Programming:
1. Turn the ignion key to ON.
2. Press and release the valet buon three (3) mes. System will beep and ash the
parking lights one (1) me.
Press the lock buon on each remote. The system will beep one (1) me to indicate the
remote has been programmed. If programming one (1) buon remotes, press the Start
buon. Only primary remote funcons are auto programmed. This Includes Lock, Unlock,
and Trunk/Start.
If using AUX output control, you must manually program the AUX output channels to
the remote. Please see the complete installaon guide for manual remote programming
instrucon.
Note: If programming 2-Way remotes, wait for the remote to beep before programming
addional remotes. This beep is conrmaon that a 2-Way response has been received
from the main module.
Feature Programming
The PRORS Feature Banks can be programmed by using the valet buon and remote. To
enter Feature Bank programming:
1. Turn the ignion key to ON.
2. Press and release the valet buon three (3) mes. System will beep and ash lights
one (1) me for Feature Bank 1, Remote Programming.
3. Cycle ignion key OFF/ON. System will beep and ash lights two (2) mes for
Feature Bank 2.
4. Press valet buon to cycle features. LED will ash to display feature number.
5. Press lock buon to cycle opons. System will beep to indicate opon number.
6. Cycle ignion key OFF/ON. System will beep and ash lights three (3) mes for
Feature Bank 3.
7. Press valet buon to cycle features. LED will ash to display feature number.
8. Press lock to cycle opons. System will beep to indicate opon Number.
Tach Programming
The installer must manually congure the Engine Conrmaon method in Feature Bank
3, Feature 5. The default method is “Tach”. When using the default “Tach” method, the
vehicle tach rate must be programmed. To enter tach rate programming:
1. Turn the ignion key ON.
2. Press and release the valet buon three (3) mes.
3. Turn the ignion key OFF.
4. Press and hold valet buon.
5. While holding valet buon, start the engine using the key.
6. Hold the valet buon for approximately ten (10) seconds. If connected to the vehicle
Tach source, the system will ash the parking lights one (1) me every second.
7. Release the valet buon. The system will turn on the parking lights for two (2)
seconds to indicate the tach rate is programmed.
The tach rate can also be programmed without the use of a valet buon. This is helpful
when using the OEM remote of CarLink system to control this module. To program the tach
rate without a valet buon:
1. Turn the ignion key to the ON posion and start the vehicle’s engine.
2. Wait for Engine RPM to lower to a normal idle.
3. Press and hold the vehicle’s brake pedal.
4. Press the LOCK buon on the OEM remote or the Carlink App.
Note: Programming tach signal via OEM or Telemacs control is only available on Firmware
v1.47 or Higher.
Data Protocol Selecon
The default data port protocol of this model is ADS (iDatalink 2-Way). This model is capable
of detecng the correct data port protocol (ADS or DBI) and automacally conguring
Feature Bank 2; Feature 18. To inialize the detecon procedure:
1. Press and hold the valet buon.
2. Cycle the vehicle’s Ignion ON/OFF two (2) mes.
3. Release the valet buon.
The system will automacally detect and set the correct data port protocol, ADS or DBI.
Note: This feature is only available on module rmware v2.0 or higher.
Nocaons
2 Remote Shutdown
3 Brake On
4 Manual Mode
5 Hood Open
6 Low / No Tach
7 Tach Programming
8 High Tach
OEM Security
The PRORS can provide OEM level security. The system will monitor all entry zones
(Door, Hood, And Trunk). When an entry zone is detected the system will beep the
vehicle horn and ash the parking lights. This feature must be acvated in Feature Bank
2, Feature 12.
Chirp Delete
System ARM/DISARM chirps can be toggled ON or OFF without entering the Feature
Bank programming.
1. Turn the ignion key ON/OFF.
2. Press and release the valet buon three (3) mes.
The system will respond with one (1) chirp for ON and two (2) Chirps for OFF. This
feature will not aect alarm trigger or programming.
User Programmable LED
System LED nocaons can be turned ON or OFF without entering Feature Bank
programming.
1. Turn the ignion key ON/OFF, ON/OFF.
2. Press and hold valet buon for ve (5) seconds.
The LED will ash one (1) me for ON, two (2) mes for OFF. This feature will not aect
LED ash during programming.
Remote Start
If the remote start fails to start the vehicle, the system will ash the vehicle parking
lights to indicate the cause.
Dome Delay Programming
This system can be programmed to ignore the vehicle’s theater dimming dome light. This
feature will be used when connecng the door trigger input to the dome light circuit for
alarm trigger.
Start with all doors closed and the vehicle dome light o.
1. Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light solid.
2. Open and close the driver door.
The system will monitor the dome light circuit. When the dome light turns o the system
will set the delay me and add an addional two (2) seconds.
Dome Delay Reset
1. Key ON/OFF, ON/OFF, ON/OFF.
2. Press and hold valet buon for ve (5) seconds.
The system will beep one (1) me to indicate reset is complete.
Programmable Input Control
Programmable Input Control allows any PIC be congured to one of the opons listed
below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.