PRORS
Remote Start w/Keyless Entry
System Layout
For Complete Installaon Guide and Technical Support Visit www.voxxuniversity.com. Or Call 1-800-225-6074 2020 Voxx Electronics. All Rights Reserved.
1
2
3
4
1 2 3 4
1
2
3
4
1 Red/Black Ignion 3 Flex Relay (87) Input
2 Pink Ignion 3 Flex Relay (30) Output
3 Yellow Starter Output (+)
4 Green Ignion 2 Output (+)
5 Red Baery 12V (+)
6 Red/White Baery 12V (+)
7 Purpl e Accessory Output (+)
8 Blue Ignion 1 Input / Output (+)
8 Pin Start
P
P
P
1White Data RX
2Black Ground (-)
3 Blue Data TX
4 Red BaƩery 12V (+)
DBI
1White Data RX
2Blue Data TX
3 Black Ground (-)
4 Red BaƩery 12V (+)
RF
1Blue Data TX
2White Data RX
3 Black Ground
4 Red BaƩery 12V (+)
Carlink
4 Red BaƩery 12V (+)
3 Black Ground (-)
2Blue Data TX
1White Data RX
Weblink
22 Green
Unlock Output (-) (NOC 11)
21 Dk. Blue
Trunk Output (-) (NOC 9)
20 Red Lock Output (-) (NOC 10)
19 Green/Lt. Blue Ch. 4 AUX Output (-) (NOC 8)
18 Black/White Horn Output (-)
17 Lt. Blue/Green Ch. 5 AUX Output (-) (NOC 7)
16 Red/Black 2nd Unlock Output (-) (NOC 12)
15 Black/Lt. Green
Factory Arm Output (-) NOC 6)
14 Brown/Black Brake Input (+) (PIC 6)
13 Black/Blue Factory Disarm Output (-) (NOC 5)
12 Dk. Blue/Black External Acvaon Input (-) (PIC 5)
11 Black/Red Pul se Aer Shutdown Output (-) (NOC 4)
10 Orange/Black Parking Brake Input (-) (PIC 4)
9 Black/Yellow Pul se During Crank Output (-) (NOC 3)
8 Green/Yellow Diesel Glow Plug Input (+) (PIC 3)
7 Green/Whi te DomeLight Output (-) (NOC 2)
6 Purpl e/Brown Door Trigger Input (- / +)
5 Lt. Blue Remote Start Status Output (-) (NOC 1)
4 Green/Orange Tach Input (-)
3 Gray/Black Hood Input (-) (PIC 2)
2 Lt. Green Trunk Trigger Input (-) (PIC 1)
1 Orange Starter Kill Relay / An-Grind Output (-)
22 Pin Input/Output
1 2 3 4
VOXX
FLCART Dock
Replacement Part #4120457
Replacement Part #4120463
Replacement Part #4120458
Not Included
Not Included
Not Included
Not Included
1 White Parking Light (30) Output
2 White/Red Parking Light (87) Input
3 Yellow/Black Ignion Output (+) (Not For Remote Start)
4 Black Ground Input (-)
4 Pin Light
P
Replacement Part #4360832
This Harness is included with the FLCART.



Not Included
19
17
15
13
11
9
7
5
3
1 2
4
6
8
10
12
14
16
18
20
21 22
19 20
17 18
15 16
13 14
11 12
910
7 8
5 6
3 4
1 2
1 3 5 7
2 4 6 8
1 3
2 4
Compable RF Kits
PR1BZ
PR1BZLR
PR1BTWZ
PR5BZ
PE2LEDZ
PE2LCDZ
PE1M2LEDZ
PE1M2LCDZ
Important Update
The default Data Port Protocol of this system is ADS. If using an FLCAN or
other external integraon module be sure to choose iDatalink 2-Way when
ashing.
This system will also support DBI. This will require programming Feature
Bank 2, Feature 15 to DBI.
PRORS
Keyless / Remote Start
Quick Installaon Guide
For Complete Installaon Guide and Technical Support
Visit
www.voxxuniversity.com
Or Call
1-800-225-6074
1 Chirp 2 Chirp
3 Chirp 4 Chirp 5 Chirp 6 Chirp
1 Lock / Unlock Funcon 500ms 3.5sec 500ms L, DBL UL DBL L, 500ms UL DBL L, DBL UL 500ms L, 350ms UL
2 Ignion Lock OFF ON
3 Ignion Unlock OFF Unlock All
Unlock Driver
4 Exterior Illuminaon OFF With Arm
With Disarm With Arm & Disarm
5 Auto Relock OFF ON
6 Auto Arming / Locking N/A
7 Nocaon Sound N/A
8 Horn Timing 16ms 30ms
40ms 50ms 10ms
9 Valet Override Method N/A
10 Driver Priority Unlock OFF ON
11 Silent Choice OFF From Transmier
OEM Style
12 Security Prole OFF OEM Security
Security w/ OEM RS
13 Door Trigger Input Negave Posive
14 Park Light / Trunk Swap OFF ON
15 Data Port Protocol ADS DBI
16 Dome Light Delay Timer OFF / Program 15sec
30sec 45sec 60sec 120sec
17 Alarm Trigger Legnth 30sec 45sec 60sec
90sec 120sec
1 Chirp 2 Chirp
3 Chirp 4 chirp 5 Chirp 6 Chirp
1 Defrost Output Pulsed 10min
RS Runme
2 RS Start Nocaon ON OFF
3 RS Runme
15min 20min 45min 60min 5min 10min
4 RS Parking Lights Steady Flashing
5 Engine Conrmaon Tach Voltage
Data Hybrid
6 Voltage Level >0.5v B4 Start <0.5v B4 Start
7 Ignion 2 Output Ignion Accessory
Start
8 Ignion 3 Output Ignion Accessory Start
9 Accessory Output Accessory Ignion
Start
10
Transmission Auto Manual
11 Max Crank Time 0.8sec 1.0sec
1.5sec 2.0sec 3.0sec 4.0sec
12 Diesel Delay OFF Diesel 5 Diesel 10
Diesel 15 Diesel 20 Diesel 30
13 Temperature Start OFF
14°F 5°F 0°F -4F -14F
14 Crank Duraon Averaging Preset
15 RS Shock Override Shunt unl Clear Shunt RS Cycle
Shunt From TX
16 Turbo Timer OFF 3min
5min 10min
17 Start Acvaon Two Press One Press
Three Press
18 RS Lock Funcon No Change UL Before L Aer
UL Before Start Lock Aer Start
19 Factory Disarm Output Single Pulse Double Pulse
350ms 500ms 800ms Same As Bank 2, F1
20 Addional Unlock Pulse No Pulse IGN, ACC, GWR
IGN,ACC,GWR,PASD
Features
Feature Bank 2
Opons
Features
Feature Bank 3
Opons
Negave Output Control (NOC)
AUX Output Control
Negave output control allows any NOC to be programmed for any one of nineteen (19)
opons. This feature is accessible via FlashLogic Weblink or Weblink Mobile.
Any AUX output can congured using the AUX Control Menu. This feature is only
accessible via FlashLogic Weblink or Weblink Mobile.
The Feature Banks below can also be programmed using the FlashLogic Weblink or Weblink Mobile.
10 Second Pulse
15 Second Pulse
20 Second Pulse
30 Second Pulse
Push & Hold
Latch ON/OFF
Latch 10min w/ RS
Latch Run�me
5 Second Pulse
1 Second Pulse
Headlight
Defrost
LED
Ch. 4 AUX
Ch. 5 AUX
Ch. 6 AUX
Ch. 7 AUX
Factory Disarm
Factory Arm
Accessory
Pulse During Crank
Pulse Aer Shutdown
Lock
Unlock
2nd Unlock
Trunk
Remote Start Status
Ignion
Ground While Armed
Ground While Disarmed
Domelight
REV. B 2020 Voxx Electronics. All Rights Reserved.
Remote Programming
The PRORS does not include an RF remote kit. The RF remote kit Includes two (2) remotes,
one (1) antenna, and one (1) cable. When added, remotes must be programmed to
the system. Remote Programming is located in Feature Bank 1. To enter Remote Auto
Programming:
1. Turn the ignion key to ON.
2. Press and release the valet buon three (3) mes. System will beep and ash the
parking lights one (1) me.
Press the lock buon on each remote. The system will beep one (1) me to indicate the
remote has been programmed. If programming one (1) buon remotes, press the Start
buon. Only primary remote funcons are auto programmed. This Includes Lock, Unlock,
and Trunk/Start.
If using AUX output control, you must manually program the AUX output channels to
the remote. Please see the complete installaon guide for manual remote programming
instrucon.
Note: If programming 2-Way remotes, wait for the remote to beep before programming
addional remotes. This beep is conrmaon that a 2-Way response has been received
from the main module.
Feature Programming
The PRORS Feature Banks can be programmed by using the valet buon and remote. To
enter Feature Bank programming:
1. Turn the ignion key to ON.
2. Press and release the valet buon three (3) mes. System will beep and ash lights
one (1) me for Feature Bank 1, Remote Programming.
3. Cycle ignion key OFF/ON. System will beep and ash lights two (2) mes for
Feature Bank 2.
4. Press valet buon to cycle features. LED will ash to display feature number.
5. Press lock buon to cycle opons. System will beep to indicate opon number.
6. Cycle ignion key OFF/ON. System will beep and ash lights three (3) mes for
Feature Bank 3.
7. Press valet buon to cycle features. LED will ash to display feature number.
8. Press lock to cycle opons. System will beep to indicate opon Number.
Tach Programming
The installer must manually congure the Engine Conrmaon method in Feature Bank
3, Feature 5. The default method is “Tach”. When using the default “Tach” method, the
vehicle tach rate must be programmed. To enter tach rate programming:
1. Turn the ignion key ON.
2. Press and release the valet buon three (3) mes.
3. Turn the ignion key OFF.
4. Press and hold valet buon.
5. While holding valet buon, start the engine using the key.
6. Hold the valet buon for approximately ten (10) seconds. If connected to the vehicle
Tach source, the system will ash the parking lights one (1) me every second.
7. Release the valet buon. The system will turn on the parking lights for two (2)
seconds to indicate the tach rate is programmed.
The tach rate can also be programmed without the use of a valet buon. This is helpful
when using the OEM remote of CarLink system to control this module. To program the tach
rate without a valet buon:
1. Turn the ignion key to the ON posion and start the vehicle’s engine.
2. Wait for Engine RPM to lower to a normal idle.
3. Press and hold the vehicle’s brake pedal.
4. Press the LOCK buon on the OEM remote or the Carlink App.
Note: Programming tach signal via OEM or Telemacs control is only available on Firmware
v1.47 or Higher.
Data Protocol Selecon
The default data port protocol of this model is ADS (iDatalink 2-Way). This model is capable
of detecng the correct data port protocol (ADS or DBI) and automacally conguring
Feature Bank 2; Feature 18. To inialize the detecon procedure:
1. Press and hold the valet buon.
2. Cycle the vehicle’s Ignion ON/OFF two (2) mes.
3. Release the valet buon.
The system will automacally detect and set the correct data port protocol, ADS or DBI.
Note: This feature is only available on module rmware v2.0 or higher.
Nocaons
1 Run�me Expired
2 Remote Shutdown
3 Brake On
4 Manual Mode
5 Hood Open
6 Low / No Tach
7 Tach Programming
8 High Tach
OEM Security
The PRORS can provide OEM level security. The system will monitor all entry zones
(Door, Hood, And Trunk). When an entry zone is detected the system will beep the
vehicle horn and ash the parking lights. This feature must be acvated in Feature Bank
2, Feature 12.
Chirp Delete
System ARM/DISARM chirps can be toggled ON or OFF without entering the Feature
Bank programming.
1. Turn the ignion key ON/OFF.
2. Press and release the valet buon three (3) mes.
The system will respond with one (1) chirp for ON and two (2) Chirps for OFF. This
feature will not aect alarm trigger or programming.
User Programmable LED
System LED nocaons can be turned ON or OFF without entering Feature Bank
programming.
1. Turn the ignion key ON/OFF, ON/OFF.
2. Press and hold valet buon for ve (5) seconds.
The LED will ash one (1) me for ON, two (2) mes for OFF. This feature will not aect
LED ash during programming.
Remote Start
If the remote start fails to start the vehicle, the system will ash the vehicle parking
lights to indicate the cause.
Dome Delay Programming
This system can be programmed to ignore the vehicle’s theater dimming dome light. This
feature will be used when connecng the door trigger input to the dome light circuit for
alarm trigger.
Start with all doors closed and the vehicle dome light o.
1. Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light solid.
2. Open and close the driver door.
The system will monitor the dome light circuit. When the dome light turns o the system
will set the delay me and add an addional two (2) seconds.
Dome Delay Reset
1. Key ON/OFF, ON/OFF, ON/OFF.
2. Press and hold valet buon for ve (5) seconds.
The system will beep one (1) me to indicate reset is complete.
Programmable Input Control
Programmable Input Control allows any PIC be congured to one of the opons listed
below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.
N.C. Door Trigger
External Start Ac�va�on
Pre-Warn Shock Trigger
Diesel Glow Plug
Door Trigger
Full Shock Trigger
Trunk Trigger
Parking Brake
Hood Trigger
Brake

Other PURSUIT Remote Starter manuals

PURSUIT PR1BZ User manual

PURSUIT

PURSUIT PR1BZ User manual

PURSUIT PRO9056Z User manual

PURSUIT

PURSUIT PRO9056Z User manual

PURSUIT PRO9233E User manual

PURSUIT

PURSUIT PRO9233E User manual

PURSUIT PRO9233Z Installation and operating manual

PURSUIT

PURSUIT PRO9233Z Installation and operating manual

PURSUIT PRO9556E User manual

PURSUIT

PURSUIT PRO9556E User manual

PURSUIT PRO9556Z Installation and operating manual

PURSUIT

PURSUIT PRO9556Z Installation and operating manual

PURSUIT PRO9051Z User manual

PURSUIT

PURSUIT PRO9051Z User manual

PURSUIT PR71TW User manual

PURSUIT

PURSUIT PR71TW User manual

PURSUIT PRO9776Z User manual

PURSUIT

PURSUIT PRO9776Z User manual

PURSUIT PRO9556Z User manual

PURSUIT

PURSUIT PRO9556Z User manual

PURSUIT PRO-9775T User manual

PURSUIT

PURSUIT PRO-9775T User manual

Popular Remote Starter manuals by other brands

Nobody Messes with... IT JT 100K Operation instructions

Nobody Messes with... IT

Nobody Messes with... IT JT 100K Operation instructions

Volkswagen 000.065.760 installation instructions

Volkswagen

Volkswagen 000.065.760 installation instructions

Astroflex RS-414 owner's guide

Astroflex

Astroflex RS-414 owner's guide

Westfalia Jumper instruction manual

Westfalia

Westfalia Jumper instruction manual

Sealey POWERSTART200 instructions

Sealey

Sealey POWERSTART200 instructions

Carbine 76CSR owner's manual

Carbine

Carbine 76CSR owner's manual

BUTURE BR400 user manual

BUTURE

BUTURE BR400 user manual

NOCO Genius Boost+ GB40 user guide

NOCO Genius

NOCO Genius Boost+ GB40 user guide

Prestige PE1BZLR owner's guide

Prestige

Prestige PE1BZLR owner's guide

SATA AE5721 user manual

SATA

SATA AE5721 user manual

Prestige Prestige 07S3BP Programming guide

Prestige

Prestige Prestige 07S3BP Programming guide

Directed Xpresskit DBALL2 installation guide

Directed

Directed Xpresskit DBALL2 installation guide

Audiovox Prestige APS-56 owner's manual

Audiovox

Audiovox Prestige APS-56 owner's manual

ProStart CT-4311TW user guide

ProStart

ProStart CT-4311TW user guide

Winplus JUMP STARTER PRO user manual

Winplus

Winplus JUMP STARTER PRO user manual

Directed Python 4218P owner's guide

Directed

Directed Python 4218P owner's guide

CrimeStopper CS-8050 Installation & operating instructions

CrimeStopper

CrimeStopper CS-8050 Installation & operating instructions

CrimeStopper CS-830RKE installation instructions

CrimeStopper

CrimeStopper CS-830RKE installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.