Check Components and Details
Additional Components Required
Make sure your VoltPAQ-X2/X4 Amplier includes the following components:
To complete the VoltPAQ-X2/X4 set up, you will need the following:
Quick Start Guide: VoltPAQ-X2/X4 Linear Power Amplifier
STEP 1
STEP 2
• If you are using the VoltPAQ-X2/X4 to drive a Quanser
experiment, please refer to the particular experiment’s
Quick Start Guide for connection instructions.
• If you intend to use the VoltPAQ-X2/X4 to drive a third
party experiment, please refer to the VoltPAQ-X2/X4
User Manual for connector pinouts and specications.
1. VoltPAQ-X2 or VoltPAQ-X4 Linear Power
Amplier (VoltPAQ-X2 pictured)
2. Main power cord
3. Set of three slow blow fuses - 3A, 250 V, 3AG
(5 fuses supplied with VoltPAQ-X4)
4. Set of two 4-pin DIN to 6-pin DIN motor cables
(4 cables supplied with VoltPAQ-X4)
5. Set of four 2xRCA to 2xRCA cables
(6 cables supplied with VoltPAQ-X4)
6. Quanser Workstation Resources*
(includes User Manual and Quick Start Guide)
Set Up the Hardware
STEP 3
6
2
Solutions for teaching and research. Made in Canada.
INFO@QUANSER.COM +1-905-940-3575 QUANSER.COM
USER MANUAL
VoltPAQ-X2/X4 Amplifier
Set Up and Configuration
Mix and match components and peripherals to suit your education or research needs
VoltPAQ-X1
AMPAQ-L2
VoltPAQ-X2 VoltPAQ-X4
AMPAQ-L4 AMPAQ-PWM
Quanser’s range of control peripherals includes ampliers and data acquisition boards. They can be purchased
separately to control educational or research-grade plants. Mix and match these peripherals with Quanser plants
and control design software to accelerate control system design and implementation.
To nd the right peripherals for your teaching or research needs, please email info@quanser.com.
©2013 Quanser Inc. All rights reserved.
CAPTIVATE. MOTIVATE. GRADUATE .
AB
CD
Plug the supplied power cord into the back of the amplier.
1
Set the GAIN switch on the VoltPAQ-X2/X4 to 1X.
This is the default setting used for most devices.
Make sure you turn ON the VoltPAQ-X2/X4 before running
the experiment.
3
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
This Class A digital apparatus complies with
Canadian ICES-003.
Cet appareil numérique de la classe A est
conforme à la norme NMB-003 du Canada.
100 - 120 V~ or
200 - 240 V~
4.6 A
50Hz - 60Hz, Class 1
Fuse: 3.0A, 3AG,
Slow-Blow
F
U
S
E
F
U
S
E
F
U
S
E
F
U
S
E
F
U
S
E
F
U
S
E
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
This Class A digital apparatus complies with
Canadian ICES-003.
Cet appareil numérique de la classe A est
conforme à la norme NMB-003 du Canada.
100 - 120 V~ or
200 - 240 V~
4.6 A
50Hz - 60Hz, Class 1
Fuse: 3.0A, 3AG,
Slow-Blow
F
U
S
E
F
U
S
E
F
U
S
E
F
U
S
E
F
U
S
E
F
U
S
E
Enabled
Gain 1X 3X
Amplifier Command
Current Sense (1V=1A)
Analog Sensors
±1.5A Max
S1
S2
S3
S4
±12V Power
E-Stop
To Load
Amplifier 0 Amplifier 1
VoltPAQ-X2
2 CHANNEL LINEAR VOLTAGE AMPLIFIER
WWW.QUANSER.COM
MADE IN CANADA
Amplier
AmplierAmplier
4 5
Quanser Rapid Control Prototyping Toolkit for NI LabVIEW™
Visit www.ni.com/labviewtools/rcp
Note: must be purchased separately.
*Download from the RCP Toolkit Resources
at www.ni.com/labviewtools/rcp.
ni.com/labviewtools/rcp
RCP Toolkit