4. Reliability Test
Afterbeing worked inachamberat +80 for 1hour, then
soundershall be placed inachamberat -30 for 1hour(1cycle
is the belowdiagram).
After6abovecycles, soundershall be measured afterbeing
placed innaturalcondition for1hour.
Afterbeing placed inachamberwith 90 to95%R.H.at +40±2
for2hand then being placed innaturalcondition for2h,
soundershall be measured.
First being worked inachamberwith -30±2for 2hand
then being placed inachamberwith -30±2 ℃for16h, finally
being placed innaturalcondtion for2h, soundershall be
measured.
Afterbeing woked inachamberwith +80±2for 2h and then
being placed innaturalcondition for2h, soundershall be
measured.
4
3
ThermalShock
Test
HumidityTest
2
1
LowTemperature
Test
High Temperature
Test
Item Specification
Aftertest(1~7item), the transducrS.P.L. differenceshall be within ±10dB, and the
appearancenot exist anychange tobe harmfultonormaloperation(e.g.cracks,rusts,damages
and especially distortion).
ModelNo. :
Page
Revision No.
Drawing No.
4/10
SpecificationforMagneticTransducer
-30
+80
1hour
20 Sec.
1hour
高温试验 将产品置于+80±2 试验箱中,先工作 2小时,然后在正常大
气压条件下恢复2小时后,进行测量
低温试验 将产品置于-30±2 试验箱中,先工作 2小时,再放置16小时,
然后在正常大气压条件下恢复 2小时后,进行测量
将产品置于湿度为90~95%R.H,温度为 ±2℃试验箱中2
小时,然后在正常大气压条件下恢复 2小时后,进行测量
潮湿试验
热冲击试验 将产品置于+80±2 ℃试验箱中,先工作 1小时,然后将产品置
于-30±2 ℃试验箱中,再工作1小时,经过6个循环后,在正常大
气压条件下恢复1小时,进行测量
在1-7项试验后,声响器的声压变化值在±10dB之内,外观无变化(例如:开裂、生锈、
损伤、变形等现象).
DAPG1206A-K8115 OEM8115R
1.0