QUBINO FLUSH SHUTTER ZMNHOD1 User manual

EN.
USER MANUAL EN.
QUBINO FLUSH SHUTTER DC
The Qubino Flush Shutter DC module is ideal for remotely controlling 12–24V DC motors of
blinds, rollers, shades, venetian blinds and similar sunscreens.

EN.
Table of contents
About Qubino .............................................................................................................................3
Safety Information .................................................................................................................... 4
Flush Shutter DC - Available Frequencies .................................................................................. 4
1. Introduction.............................................................................................................................5
2. Qubino Flush Shutter DC Advantages and Highlights ............................................................ 6
3. Package Contents .................................................................................................................. 8
4. Technical Terms Used In the Manual ..................................................................................... 9
5. Installation............................................................................................................................10
6. Product Information And Support......................................................................................... 14
7. Electrical Diagram (12-24 VDC) .............................................................................................. 15
8. Z-Wave Inclusion.................................................................................................................. 16
9. Z-Wave Exclusion ................................................................................................................. 18
10. Associations........................................................................................................................ 19
11. Flush Shutter DC Calibration ................................................................................................ 21
12. Configuration Parameters....................................................................................................24
13. Technical Specifications ......................................................................................................35
14. Z-Wave Command Classes..................................................................................................36
15. Important Disclaimer.......................................................................................................... 40
16. Warning.............................................................................................................................. 40
17. Regulations ........................................................................................................................ 40

EN.
About Qubino
Qubino is a family of innovative Z-Wave modules, many of them the smallest of their kind in
the world. Numerous breakthrough innovations, 100% quality control and responsive customer
service make Qubino the number one choice for ambitious DIYers.
Qubino enables you to transform – inexpensively and invisibly – any traditional electric device
into a smart, connected one which you can control with your smart phone. Qubino modules are
simple to install and use, but also extremely versatile - if you are a demanding and ambitious
DIYer, there is also a wealth of additional features and parameters for you to play with.
What we really love to do is help dedicated DIYers – people who enjoy creating new ideas for
their home and then using their hard work and skill to turn ideas into reality. We admire your
passion and resourcefulness. We do our best to supply you with products that will enable you
to create a unique and special home for yourself. We innovate so that you can be free to make
the smartest home possible. With just a touch of magic.
"Simple is smart". We believe it is smart to make complex things simple. But only when this
means simple for our customers, not for ourselves. We think a lot so that DIYers won't have to
when it comes to installing or using our modules.
For more information visit: www.qubino.com
About Z-Wave:
The Z-Wave protocol is an interoperable, wireless, RF-based communications technology
designed specifically for control, monitoring and status reading applications in residential and
light commercial environments. Mature, proven and broadly deployed (with over 50 million
products sold worldwide), Z-Wave is by far the world market leader in wireless control, bringing
affordable, reliable and easy-to-use 'smart' products to many millions of people in every
aspect of daily life.
Source: www z-wavealliance.org

EN.
Safety Information
To ensure your safety, please read this manual carefully before device installation and follow
the instructions herein. The manufacturer (GOAP d.o.o. Nova Gorica) shall not be legally
responsible for any equipment damage or personnel injury caused by incorrect installation or
operation other than that covered in this manual.
Flush Shutter DC - Available Frequencies
ORDERING CODE
Z-WAVE FREQUENCY
ZMNHOD1
868,4 MHz
ZMNHOD2
921,4 MHz
ZMNHOD3
908,4 MHz
ZMNHOD4
869,0 MHz
ZMNHOD5
916,0 MHz
ZMNHOD8
865,2 MHz

EN.
1. Introduction
The Flush Shutter DC is a module that controls 12–24V DC motors of blinds, rollers, shades,
venetian blinds and similar sunscreens. It can be paired with a digital temperature sensor (sold
separately). It supports push-button/momentary switches and toggle switches (default).
The Qubino Flush Shutter DC module can measure the power consumption of both connected
electrical devices separately and itself has an extremely low power consumption of less than
0.4 W.
The Qubino Flush Shutter DC module can operate across a wide temperature range, from a
chilly -10˚C to a scorching 40˚C (14˚–104˚F). It supports the connection of a digital temperature
sensor, which means you can create complex scenarios and switch any device relative to a set
temperature range. Every module also acts as a repeater in order to improve the range and
stability of the Z-Wave network.

EN.
2. Qubino Flush Shutter DC Advantages and Highlights
•With the Qubino Flush Shutter DC Module which allows you to remotely and
automatically control your 12–24V DC motors of blinds, rollers, shades, venetian blinds
and other motorized sunscreens. It’s the only Z-Wave module in the world which is able
to control 12-24V DC motors.
•Qubino Flush Shutter DC allows the easiest and quickest installation. It fits smoothly
even in the smallest, most shallow and most crowded flush mounting boxes which are
stuffed with lots of electrical cables. All this is possible because Qubino Flush Shutter
DC is the smallest Z-Wave shutter in the world.
•Qubino Flush Shutter DC has the option to connect a (separately bought) temperature
sensor, through which users can monitor the temperature of the air or water. It’s the
only Z-Wave switch in the world, which offers that possibility. With sensor connected,
the user can carry out accurate measurements of the room temperature, pool water
temperature etc. and adapt the relevant scenarios accordingly. Qubino Flush Shutter DC
with temperature sensor is connected directly to the power supply. It is an install and
forget product, so users don't need to worry about the changing the batteries at least
once a year, like with battery powered temperature sensors.
•Every Qubino module has guaranteed 100% quality control throughout the production
process. Every product has a unique a serial number and a part number, which are
assigned to the module only after it goes through strict testing procedure.
•By scanning the QR code on the back of your Qubino, the serial and part number of the
module are automatically copied on user’s mobile device and they can have direct
access to Qubino’s technical support team. With the help of serial and part number, the
support team can check the production log file, which contains the date of production
as well as all the relevant product parameters and information, so they are able to give
the best support possible.
•Qubino Flush Shutter DC is engineered and manufactured entirely in the EU and
contains only the highest quality components such as OMRON relay.
•Qubino Flush Shutter DC is safety certified by an independent European Institute and
has LVC and EMC certificates.

EN.
ADDITIONAL PRODUCT HIGHLIGHTS:
•Precise Z-Wave and manual control of motorized blinds, shades, shutters, and
sunscreens
•Allows control of venetian blinds and changing vertical position and angle of the shades
•Calibrates positioning automatically from your smart home UI and locally
•Works with push-button (momentary) and toggle switches
•Works with motors controlled by mechanical and electronic wall switches
•Straightforward installation
•Remembers and restores its state after power outage
•Comes with auto-inclusion mode for the quickest set-up possible (add it to your Z-
Wave network with one click)
•Equipped with over a dozen advanced parameters for further customization*
•Features energy monitoring for your motorized blinds which allows automatically
calibrations and an overview of energy consumption
•Equipped with strong signal repeater powered by Z-Wave Plus technology
*Your controller needs to support advanced configuration and parameter input to display these
features.

EN.
3. Package Contents
•Flush Shutter DC Module
•Installation Manual

EN.
4. Technical Terms Used In the Manual
Symbol
Switch example images
Definition
EU
USA
Qubino
Other
names
Single pole,
single throw
(SPST)
One-way
switch
Two-way
switch
(regular
switch)
Toggle
switch
Switch;
Bi-stable
switch
Single pole,
double throw
(SPDT)
Two-way
switch
Three-
way
switch
Two-way
switch
Used when you
have three or
more switches
controlling the
same light
Intermedi-
ate switch
Four-way
switch
Intermedi-
ate switch
Crossover
switch;
Cross
connection
After relasing it
goes back to
original state
Momentary switch Momentary
switch
Monostable
switch;
Push button

EN.
5. Installation
After Qubino installation:

EN.
Temperature sensor installation:

EN.
The installation process, tested and approved by professional electricians, consists of the
following simple steps:
1. To prevent electrical shock and/or equipment damage, disconnect electrical power at
the main fuse or circuit breaker before installation and maintenance.
2. Be aware that even if the circuit breaker is off, some voltage may remain in the wires —
before proceeding with the installation, be sure no voltage is present in the wiring.
3. Take extra precautions to avoid accidentally turning on the device during installation.
4. Connect the module exactly according to the diagram.
5. Place the antenna as far as possible from metal elements as they may cause signal
interference.
6. Do not shorten the antenna.
The module’s antenna should be as upright as possible. This way the Z-wave operational range
can be wider (up to 30m indoors (98ft)).

EN.
ⓘ Danger of electrocution!
Installation of this module requires a great degree of skill and may be performed only by a
licensed and qualified electrician. Please keep in mind that even when the module is turned off,
voltage may still be present in the module’s terminals.
ⓘ Note!
Do not connect the module to loads exceeding the recommended values. Connect the module
exactly as shown in the provided diagrams. Improper wiring may be dangerous and result in
equipment damage.
For overload protection use fuse F (ESKA 522.724 5A 250V) connected according to the
electrical diagram. The fuse installation is according to the standard IEC 60950-1. This
standard is used in Europe only.

EN.
6. Product Information And Support
Did you know that Qubino offers Z-Wave modules with guaranteed 100% quality control
throughout the production process? Every single unit is tested and examined before being
approved for sale – a truly unique pledge in the industry.
Why is this important?
Every product has a dedicated a serial number and a part number, which is assigned to the
module only after it goes through a strict testing procedure.
By scanning the QR code on the back of your Qubino module, its product title, serial number,
and part number are automatically copied to your mobile device. You can also use the code for
direct access to the module’s product page for more information. If you still don’t find what
you’re looking for, click on the link to Qubino technical support team. They will be able to
automatically read the serial and part number from your module and quickly review the
production log file containing production date as well as any relevant device parameters and
information. This process allows our team to immediately identify and address issues, giving
you the best support possible.
Based on customer and business partner feedback, we’re proud to boast Qubino’s support
team as the best and fastest on the market If you don't find the answers to your questions in
this document, please contact our support team by scanning the QR code or through our
website: http://qubino.com/support/#email. We will try to help you as soon as possible.

EN.
7. Electrical Diagram (12-24 VDC)
Notes for diagram:
+
+VDC (12-24 VDC)
-
-VDC (0V)
Q1⬆
Output for motor UP (open)
Q2⬆
Output for motor DOWN (close)
I2
Input for switch/push button DOWN (close)
I1
Input for switch/push button UP (open)
TS
Temperature sensor terminal
S
Service button (used to add or remove module from the Z-Wave network)

EN.
8. Z-Wave Inclusion
AUTO-INCLUSION
1. Enable inclusion mode on your Z-Wave controller
2. Connect the module to the power supply (with the temperature sensor already connected*).
If the sensor is not connected before the connection of the power supply it will not work.
3. Auto-inclusion will be initiated within 5 seconds of connection to the power supply and the
module will automatically enrol in your network
*the temperature sensor is sold separately

EN.
MANUAL INCLUSION
1. Connect the module to the power supply (with the temperature sensor already connected —
see the Note below)
2. Toggle the switch connected to the I1 terminal 3 times within 3 seconds
OR
Press and hold the S (Service) button for at least 2 seconds
3. A new multi-channel device will appear on your dashboard
ⓘ Make sure the module is excluded from your network before connecting the
temperature sensor. Switch off the power supply, connect the temperature sensor, and re-
include the module to your network.

EN.
9. Z-Wave Exclusion
Z-WAVE EXCLUSION
1. Connect the module to the power supply
2. Make sure the module is within direct range of your Z-Wave controller or use a hand-held Z-
Wave remote to perform exclusion
3. Enable exclusion mode on your Z-Wave controller
4. Toggle the switch connected to the I1 terminal 3 times within 3 seconds
OR
Press and hold the S (Service) button for 2 to 6 seconds
5. The module will be excluded from your network but any custom configuration parameters
will not be erased.
FACTORY RESET
1. Connect the module to the power supply
2. Within the first minute the module is connected to the power supply, toggle the switch
connected to the I1 terminal 5 times within 3 seconds
OR
Press and hold the S (Service) button for at least 6 seconds
By resetting the module, all custom parameters previously set on the module will return to
their default values, and the owner ID will be deleted. Use this reset procedure only when the
main controller is missing or otherwise inoperable.
ⓘ By resetting the module, all custom parameters previously set on the module will return
to their default values, and the owner ID will be deleted. Use this reset procedure only when
the main controller is missing or otherwise inoperable.

EN.
10. Associations
Use associations for direct communication between the Flush Shutter module and other
devices within your Z-Wave network without the need to use the primary controller.
Association Groups:
Root device:
•Group 1: Lifeline group (reserved for communication with the primary controller), 1 node
allowed.
•Group 2: Basic on/off (status change report for I1 input) up to 16 nodes.
•Group 3: Basic on/off (status change report for I2 input) up to 16 nodes.
•Group 4: Basic on/off (status change report for sensing roller moving: up=FF, down=0)
up to 16 nodes.
•Group 5: Basic on/off (status change report at reaching roller position: bottom=FF,
top=0) up to 16 nodes.
•Group 6: Basic on/off (status change report at reaching roller position: bottom=FF, not
bottom=0) up to 16 nodes
•Group 7: Multilevel set (status change report for Flush Shutter DC position), up to 16
nodes.
•Group 8: Multilevel set (triggered at changes of value of slats tilting position) up to 16
nodes.
•Group 9: Multilevel sensor report (triggered at change of temperature sensor) up to 16
nodes.
End point 1:
•Group 1: Lifeline group, 0 nodes allowed.
•Group 2: Basic on/off (status change report for I1 input), up to 16 nodes.
•Group 3: Basic on/off (status change report for I2 input), up to 16 nodes.
•Group 4: Basic on/off (triggered at sensing moving direction of roller: up=FF, down=0)
up to 16 nodes.
•Group 5: Basic on/off (triggered at reaching roller position: bottom=FF, top=0) up to 16
nodes.
•Group 6: Basic on/off (triggered at reaching roller position: bottom=FF, not bottom=0)
up to 16 nodes.
•Group 7: Multilevel set (triggered at changes of value of the Flush Shutter DC position)
up to 16 nodes.
End point 2:
•Group 1: Lifeline group, 0 nodes allowed.

EN.
•Group 2: Multilevel set (status change report slats tilting position), up to 16 nodes.
End point 3 (External Temperature Sensor):
•Group 1: Lifeline group, 0 nodes allowed.
•Group 2: Multilevel sensor report (external temperature sensor report – sensor sold
separately), up to 16 nodes.
This manual suits for next models
5
Table of contents
Popular Remote Control manuals by other brands

Tele Radio
Tele Radio T70 Series installation instructions

Acumen
Acumen RCK-K L Installation and operation instructions

Patriot Lighting
Patriot Lighting 20704 quick start guide

Cochlear
Cochlear Nucleus CR110 user guide

Logitech
Logitech Harmony 880 Guide user manual

Paul Neuhaus
Paul Neuhaus Q-Control 7202-21 manual