RAIS attika VISIO UNIQ User manual

VISIO UNIQ
DK INSTALLATIONSVEJLEDNING
DE INSTALLATIONSANLEITUNG
EN INSTALLATION GUIDE
FR NOTICE D’INSTALLATION
NO INSTALLASJONSVEILEDNING
SE INSTALLATIONSANVISNING
FIN ASENNUSOHJEET
NL INSTALLATIEHANDLEIDING

EN
1 - EN
SERIAL NUMBER MUST BE
PLACED HERE

30-11-2021
EN
EN - 2
INSTALLATION INSTRUCTIONS
CONTENTS
Installation instructions 3
General information 3
Chimney 3
Technical data 4
Specifications 4
Dimensional sketches 5
Rating plate 6
Installation 7
Packaging at delivery 7
UK-specific instructions 8
Norway-specific instructions 9
Transport safety fittings 10
Reflective insulation panel 11
Choice of material for installation 13
Installation dimensions 15
Placement distances 16
Heat distributor 19
External air connection 20
Removing the combustion chamber lining 21
Cleaning the flue 22
Cleaning the door glass 23
Cleaning the combustion chamber 24
Converting to self-closing door 25
Declaration of performance 27
Test certificate 28

EN
3 - EN
INSTALLATION INSTRUCTIONS
Thank you for choosing your new RAIS or
ATTIKA product! This installation instructions
manual will ensure that your fireplace insert
is installed correctly and that it will provide
you with comfort and pleasure for many
years to come.
GENERAL INFORMATION
It is important to correctly install the
fireplace insert out of consideration for both
the environment and personal safety.
The installation must comply with all local
rules and regulations, including those that
refer to national and European standards.
A certified chimney sweeper should be
contacted before set-up.
No unauthorised alterations may be made to
the fireplace insert.
GENERAL INSTALLATION REQUIREMENTS
Before the fireplace insert may be put to use,
the set-up must be reported to your local
chimney sweeper.
There must be a plentiful supply of fresh air
into the room where the insert is placed to
ensure good combustion, possibly through
an AirSystem connection. Be aware that
any mechanical air extraction, for example
a cooker hood, can reduce the supply of air.
Any air vent must be positioned in a way that
ensures the supply of air cannot be blocked.
The air consumption of the fireplace insert is
32 m3/h.
The floor structure must be able to support
the weight of the fireplace insert and a
chimney, if required. If the existing floor
structure does not meet this requirement,
suitable measures must be taken (e.g.
installation of a load distribution plate). If in
doubt, contact a building expert.
National and local regulations must be
complied with, including the size of the
non-flammable plate that must cover the
flammable floor in front of the fireplace insert
to protect the floor from falling embers.
The fireplace insert must be positioned at a
safe distance from flammable material. Due
to risk of fire, flammable items (e.g. furniture)
may not be positioned closer to the insert
than specified in the sections on placement.
When deciding where to install your RAIS/
ATTIKA fireplace insert, you should consider
being able to heat other rooms in your home
to get the most out of your new fireplace
insert.
After receiving your fireplace insert, please
check it for any defects.
CHIMNEY
The chimney must be tall enough to ensure
correct draught conditions, i.e. -12 pascal
to -18 pascal. If the recommended chimney
draught cannot be achieved, problems of
smoke puffing from the door may arise
when heating. We recommend adapting the
chimney to the flue pipe collar. The collar is
200 mm in diameter.
If the draught is too strong, it is advisable to
equip the chimney with a regulating damper.
If a regulating damper is fitted, you must
ensure that there is a free flow-through
area of at least 20 cm² when the regulating
damper is closed.
Remember: there must be unobstructed
access to the access door on the chimney.
The length of the chimney, calculated from
the top of the fireplace insert should not
be less than 3 metres and must be at least
80 cm above the roof ridge. If the chimney
is placed on the side of the house, the top of
the chimney must never be lower than the
roof ridge or the roof’s highest point.
Note that there are often national and local
regulations relating to houses with thatched
roofs.
The fireplace insert is suitable for being
connected to a shared flue, but we
recommend that the feed-ins are positioned
to maintain a clearance-level difference of at
least 250 mm between them.
INSTALLATION INSTRUCTIONS
Note!
RAIS/ATTIKA recommends having the in-
sert installed by an authorised technician.
Please ask your dealer for further informa-
tion.

EN
EN - 4
The fireplace insert was tested and approved by:
DTI
Danish Technological Institute
Teknologiparken Kongsvang Allé 29
8000 Aarhus C
Denmark
www.dti.dk
Tel.: +45 7220 2000, Fax: +45 7220 1019
TECHNICAL DATA
SPECIFICATIONS
Danish Technological Institute ref.: 300-ELAB-2564-EN
VISIO UNIQ, 3-SIDED MODEL
Nominal output (kW) 9.3
Min./max. output (kW) 7–11*
Heating area (m2) 180
Fireplace insert W x D x H (mm) 891 X 632 X 1525
Combustion chamber W x D x H (mm) 482 X 279 X 250**
Min. flue draught (pascal) -12
Weight (kg) min., depending on the model 268
Efficiency (%) 78
CO emission attributed to 13% O2(%) 0.0714 (893 mg/Nm³)
NOx emission attributed to 13% O2(mg/Nm³) 113
OGC emission attributed to 13% O2(mg/Nm³) 57
Particle emission in accordance with
NS3058/3059 (g/kg)
2.12
Dust measurement in accordance with DIN + 13%
O2(mg/Nm³)
23
Flue gas flow (g/s) 10.6
Flue gas temperature (°C) 228
Intended flue gas temperature (°C) at flue collar 360
Recommended wood volume (kg) for stoking the
fire (Dispersed over three pieces of firewood)
2.1
Intermittent operation Stoking should be done within
46 minutes
*Not verified by test.
**Max. load

428
691
500
512
891
891
445
632
143
512
n
198
n
198
1465
632
0
139
414
926
1398
1525
R149
292
445 445
n149*
159*445*445*
364,5
428
691
500
512
891
891
445
632
143
512
n
198
n198
1465
632
0
139
414
926
1398
1525
R149
292
445 445
n149*159*
445*445*
364,5
428
691
500
512
891
891
445
632
143
512
n
198
n198
1465
632
0
139
414
926
1398
1525
R149
292
445 445
n149*159*445*445*
364,5
428
691
500
512
891
891
445
632
143
512
n
198
n198
1465
632
0
139
414
926
1398
1525
R149
292
445 445
n149*
159*
445*445*
364,5
428
691
500
512
891
891
445
632
143
512
n
198
n198
1465
632
0
139
414
926
1398
1525
R149
292
445 445
n149*159*445*445*
364,5
EN
5 - EN
All dimensions are in mm.
DIMENSIONAL SKETCHES
* AirSystem
The top section of the flue collar can be
moved around in a radius of 149 mm
around the centre of the flue outlet.

EN 13229:2001+A1:2003+A2:2004 Raumheizer für feste Brennstoffe
Appliance fired by wood
Poêle pour combustibles solides
Produced at:
RAIS A/S, Industrivej 20, 9900 Frederikshavn, Danmark
EC.NO: 127
AFSTAND TIL BRÆNDBART, BAGVÆG
ABSTAND ZU BRENNBAREN BAUTEILEN, HINTEN
DISTANCE TO COMBUSTIBLE BACK WALL
DIST. ENTRE COMPOSANTS COMBUSTIBLES, ARRIÈRE
AFSTAND TIL BRÆNDBART, SIDEVÆG
ABSTAND ZU BRENNBAREN BAUTEILEN, SEITE
DISTANCE TO COMBUSTIBLE SIDE WALL
DISTANCE ENTRE COMPOSANTS COMBUSTIBLES, COTÉ
AFSTAND TIL BRÆNDBART, MØBLERING
ABSTAND VORNE ZU BRENNBAREN MÖBELN
DISTANCE TO FURNITURE AT THE FRONT
DISTANCE ENTRE COMPOSANTS COMBUSTIBLES, DEVANT
CO EMISSION (REL. 13% O2)
CO EMISSION IN DEN VERBRENNUNGSPRODUKTEN (BEI 13%O2)
EMISSION OF CO IN COMBUSTION PRODUCTS (AT 13%O2)
EMISSION CO DANS LES PRODUITS COMBUSTIBLES (À 13%O2)
NOMINEL EFFEKT / HEIZLEISTUNG /
THERMAL OUTPUT / PUISSANCE CALORIFIQUE:
RØGGASTEMPERATUR / ABGASTEMPERATUR /
FLUE GAS TEMPERATURE / TEMPÉRATURE DES GAZ DE FUMÉE:
VIRKNINGSGRAD / ENERGIEEFFIZIENZ /
ENERGY EFFIENCY /EFFICACITÉ ÉNERGÉTIQUE:
DK: Brug kun anbefalede brændsler. Følg instrukserne i
brugermanualen. Anordningen er egnet til røggassamleledning og intervalfyring.
DE: Lesen und befolgen Sie die Bedienungsanleitung.
Zeitbrandfeuerstätte. Nur empfohlene Brennstoffe einsetzen.
UK: Fuel types (only recommended). Follow the installation and
operating instruction manual. Intermittent operation.
F: Veuillez lire et observer les instructions du mode d'emploi.
Foyer à durèe de combustion limitèe, homologué pour cheminée à
connexions multiples. Utiliser seulement les combustibles recommandés.
Hergestellt für /Produced for:
ATTIKA FEUER AG, Brunnmatt 16, CH-6330 Cham / RAIS A/S, Industrivej 20, DK-9900 Frederikshavn
STØV / STAUB /
DUST / POUSSIÈRES: DK: 23 mg/Nm3 / DE: 23 mg/Nm3
UK: 23 mg/Nm3 / FR: 23 mg/Nm3
DK: 228 °C / DE: 228 °C
UK: 228 °C / FR: 228 °C
DK: 9,3 kW / DE: 9,3 kW
UK: 9,3 kW / FR: 9,3 kW
DK: 78 % / DE: 78 %
UK: 78 % / FR: 78 %
DK: BRÆNDE
DE: HOLZ
UK: WOOD
FR: BOIS
DK: SE BRUGERVEJLEDNING
DE: SIEHE BEDIENUNGSANLEITUNG
UK: SEE USER MANUAL
FR: CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK: SE BRUGERVEJLEDNING
DE: SIEHE BEDIENUNGSANLEITUNG
UK: SEE USER MANUAL
FR: CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK: 1000 mm/SE BRUGERVEJLEDNING
DE: 1000 mm/SIEHE BEDIENUNGSANLEITUNG
UK: 1000 mm/SEE USER MANUAL
FR: 1000 mm/CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK: 0,0714%
DE: 0,0714% / 893 mg/Nm3
UK: 0,0714%
FR: 0,0714%
CE Label: 20-09-2021
Visio Uniq
21
Visio Uniq
Notified Body: 1235
A
A
1
2
7
6
5
0
1
Production number placement
A
A
1
2
7
6
5
0
1
Production number placement
EN
EN - 6
INFORMATION PLATE
INFORMATION PLATE
All RAIS/ATTIKA fireplace inserts have a rating
plate specifying the distance from the fireplace
insert to flammable materials, efficiency, etc. The
rating plate is lying unattached in the fireplace in-
sert upon delivery.
The serial number is found in the bottom left cor-
ner of the fireplace insert. See drawing.
It is also found at the front of this installation
manual.

A
A
1
2
7
6
5
0
2
Removing stove from pallet.
A
A
1
2
7
6
5
0
2
Removing stove from pallet.
EN
7 - EN
INSTALLATION
INSTALLATION
The following section explains how to install the fireplace insert and includes informa-
tion about packaging, placement distances, etc.
PACKAGING AT DELIVERY
Upon delivery, the fireplace insert is secured to a transport pallet using four transport
safety fittings. The safety fittings are attached with screws which
must be unscrewed. The safety fittings can then be removed.
DISPOSAL
RECYCLING OF PACKAGING
The fireplace insert is delivered in recyclable pack-
aging. This packaging must be disposed of in ac-
cordance with national regulations relating to the
disposal of waste.
NB: DISPOSE OF THE FIREPLACE INSERT WHEN IT
IS WORN OUT.
The glass is not recyclable.
The glass must be disposed of along with any re-
sidual ceramic or porcelain waste. Heat-resistant
glass has a higher melting point, which is why it is
not recyclable.
By ensuring heat-resistant glass does not end up
alongside recyclable products you are making an
important contribution to the environment.

A-A
A
A
B
1276508
Engelsk DEFRA
0
43
52
EN
EN - 8
UK-SPECIFIC INSTRUCTIONS
Important!
According to DEFRA rules, the installation of Visio Uniq in the UK requires the insertion
of a mechanical stopper in the flue.
Before Visio Uniq may be installed in a ‘smoke-controlled area’ of the UK, a stopper
must be installed. This will prevent the flue from closing entirely. This is done by setting
the flue handle in the middle position, after which the enclosed 5.5 x 16 self-tapping
screw is mounted in the hole 43 mm below the flue collar. See the drawing below!
DEFRA Stop

A-A
A
A
B
1276509
Norsk storrums Stop
0
43
52
EN
9 - EN
NORWAY-SPECIFIC INSTRUCTIONS
Important!
The installation of Visio Uniq in Norway pursuant to Norway’s open-plan office rules
requires the insertion of a mechanical stopper in the flue.
Before Visio Uniq may be installed in Norway, a stopper must be installed. This will pre-
vent the flue from closing entirely. This is done by setting the flue handle in the middle
position, after which the enclosed 5.5 x 16 self-tapping screw is mounted in the hole
52 mm below the flue collar. See the drawing below!
Norwegian stopper

EN
EN - 10
Important!
For delivery, the door is locked in transit and it must be released
before installation. This is done by removing the two transport
screws in the counterweights on the back of the stove!
TRANSPORT SAFETY FITTINGS

EN
11 - EN
REFLECTIVE INSULATION PANEL
For installation with a top outlet, a reflective insulation panel must be installed to cover
the flue collar up to the insulated chimney pipe.
The reflective insulation panel is included and is found screwed onto the back of fire-
place insert. Loosen the two labelled screws and remove the panel. Do not re-tighten
them.

EN
EN - 12
REFLECTIVE INSULATION PANEL
Release the reflective insulation panel and turn it upside down (180°). Bend the two
cut-out easy-bend flanges 90° (see photo below). Loosen the two labelled screws, one
on each side. Place the two bottom holes on the reflective insulation panel over the
two screws on the back of the stove. Attach the two easy bend flanges on the two top
screws. Retighten all four screws.
Easy bend flange

EN
13 - EN
INSTALLATION
CHOICE OF MATERIAL FOR INSTALLATION
The material can be panels/brick with an insulation value greater than 0.03 m² x K/W.
The insulation is defined as wall thickness (in metres) divided by the wall’s Lambda val-
ue.
Consult your installation technician/chimney inspector.
During testing, the fireplace insert is installed in a cabinet made of non-flammable
50 mm calcium silicate panels (Skamotec 225).
The stove comes with a flue collar that is 200 mm in diameter.
The flue collar can be changed from a top outlet to a rear outlet.
Loosen the clamping strap on the outlet flange and adjust as preferred.
The fireplace insert must be placed on heat-resistant material.
See the following pages for installation dimensions and placement distances.

EN
EN - 14

A
A
1276505
Visio Uniq - Hulmål
600 cm²
400 cm²
250400
A
A
1276505
Visio Uniq - Hulmål
600 cm²
400 cm²
250400
EN
15 - EN
INSTALLATION DIMENSIONS
INSTALLATION DIMENSIONS:
Applies to installation into non-flammable panels.
Minimum cavity dimensions (H x W x D): . 512 x 791 x 462 mm
A fireplace insert must never be tightly inserted into a cavity, as steel expands when
heated.
There must be a minimum convection air intake of 400 cm² underneath the stove and
600 cm² above it. The minimum convection-air areas above and below the stove can
be distributed over several holes.
Convection air
Distance Dimensions,
mm
Distance from convection grate to flammable ceiling 250
Distance from lower door edge to flammable floor 400
Minimum
Minimum

A
A
1276505
Visio Uniq - Hulmål
600 cm²
400 cm²
250400
EN
EN - 16
SET-UP
The insulated chimney must extend
all the way down to the flue outlet
adapter.
To guide the hot air out of the convec-
tion grates, a non-flammable plate
must be installed just over the grates.

B B
1276503
Visio Uniq 3 Glass model
Normal opstilling
650
50
1000
600 cm²
400 cm²
100
B B
1276503
Visio Uniq 3 Glass model
Normal opstilling
650
50
1000
600 cm²
400 cm²
100
EN
17 - EN
MINIMUM DISTANCE MM
Distance from door to furniture 1000
Distance from side glass to furniture 650
Interior distance to cabinet 50
Distance from vertical frame to flammable wall 100
If the insulation value is complied with (greater than 0.03 m² x K/W), the cabinet may
be installed against a flammable wall provided that the interior distance from stove to
cabinet is at least 50 mm.
SET-UP
Combustible
Not Combustible

A A
1276504
Visio Uniq 3 Glass model
tilbage trukket fra væg
100
512
EN
EN - 18
If the fireplace insert is installed so that the vertical built-in frame is flush against the
wall, the first 100 mm of the wall must be made of non-combustible material such as
50 mm Skamotec 225 or brick.
INSTALLATION
Combustible
Not Combustible

EN
19 - EN
HEAT DISTRIBUTOR
HEAT DISTRIBUTOR
By installing a heat distributor unit above the fireplace insert, heat can be ‘transported’
to other rooms.
Table of contents
Popular Indoor Furnishing manuals by other brands

Regency
Regency LWMS3015 Assembly instructions

Furniture of America
Furniture of America CM7751C Assembly instructions

Safavieh Furniture
Safavieh Furniture Estella CNS5731 manual

PLACES OF STYLE
PLACES OF STYLE Ovalfuss Assembly instruction

Trasman
Trasman 1138 Bo1 Assembly manual

Costway
Costway JV10856 manual