深圳市远景达物联网技术有限公司
Shenzhen RakindaTechnology Co., Ltd.
(2) If the customer's products are plastic parts, in addition to meeting the above requirements, the screw
column should also have enough strength to prevent the fracture in the process of assembly. It is not
recommended to use self-tapping screws for screw selection. It is recommended to add copper column
of screws in the screw column and fix it with mechanical screws.
(3) During the module installation, do not touch the lens by hand. Wear anti-static gloves and anti-static
bracelet to prevent the damage of the module's main board components caused by static electricity.
2. Operating Instructions for Front Panel Glass
(1) Glass size set according to the customer product structure and light transmittance of glass all band ≧
98%, glass installation needs to have enough of the bearing surface, cannot affect the safe use, in the
case of address security thinned as far as possible, suggest 1 mm thickness, in order to prevent the
VCSEL infrared light reflection to the CCD camera, Suggestions on the glass CCD and VCSEL window
around the area to increase absorption of infrared coating.
(2) The windowing area of CCD,VCSEL and RGB on the glass is designed according to the market
Angle (refer to the 3D picture for details), and a margin should be left to prevent the assembly deviation
from causing the blocking of glass screen printing.
Figure 3. Field View of M5 Module
(3) Between the module and the glass, light-blocking cotton shall be added around the CCD and VCSEL
to prevent the infrared light of VCSEL from reflecting into the CCD lens. The compressed light-
blocking cotton shall not exceed the windowing area of the glass.
(4) Glass, light-blocking cotton and modules shall be fitted closely.
2.4 Interface Definition