RAKINDA F2-H User manual

Shenzhen Rakinda
Technologies Co.,Ltd.
File No.:
Version:
V1.0
Confidential
File Name
Face Recognition Thermal
Imaging Temperature
Measuring Device
F2-H Manual
Date
Apr., 23, 2020
Face Recognition Thermal Imaging Temperature Measuring Device
F2-H Manual
Shenzhen Rakinda Technologies Co.,Ltd. Copyright

Face Recognition Thermal Imaging Temperature Measuring Device
F2-H Manual
Application Field
F2-H is suitable for office areas, hotel, office buildings, schools, shops, communities, public services and
management projects.
Features
Dynamic detection, solve the deception of photos on various carriers
Infrared mode at night, RGB dual fill light
Support external access control card reader, QR code scanner, ID card reader
Support RS232 serial port, Wiegand 26/34 output, support relay, exit switch, door magnetic output
content
Support local storage of 500,000 historical records
Support 20,000 face library
Support public network and local area network deployment

Support HTTP interface connection;
Support display configuration;
Support identification distance configuration
Product Specification
Face Recognition Temperature Measure all-in-one
Machine
Product model
F2-H
Characteristics
Main function
Face recognition temperature measurement
Use
environmen
Indoor , semi-outdoor
Color
Silver
Camera
Type
RGB
Infrared
Resolution
2 million
pixels
2 million
pixels
Aperture
F2.8
F2.8
Focal length
3.18mm
3.18mm
Software
Dynamic
automatic
automatic
Vertical wide
angle
84°
84°
Horizontal wide
angle
54°
54°
Infrared
supplement
light
Support
White
supplement
light
Support
Core
parameters
Android
Android7.1
CPU
Quad-core, 1.8GHz
storage
capacity
RAM 2G ROM 8G
Human-
comput er
interaction
Monitor
8 inches, full viewing angle, 170 ° IPS LCD screen,
resolution
800 * 1280
Touch screen
support
Face sensing
module
support
Face
temperature
measurement
module
support,Serial / I2C interface
Card reader
Support, Optional
Communication
Ethernet
10/100 Ethernet

method
WIFI
Comply with IEEE802.11b / g / n standard (2.4G)
Identification
Method
Face
Support
IC card
Support, optional
Input \ output
interface
RJ45 interface
Support 10/100 Mbps
Power supply
interface
DC12V-2A
Power
Adapter
DC12V-2A
Environmental
requirements
Operating
temperature
-20℃~60℃
Working
humidity
20%~90% (non-condensing)
Static
protection
level
IEC61000-4-2, LEVEL3
External Interface Definition
Type
Interface
Explanatio
n
USB
USB 2.0
Support
Ethernet port
RJ45
10/100 Ethernet
Rela
y
NC
COM
NO
Relay normal off/Common/normal on.Usually,door lock
supply is positively connected to the COM port,and then
according to the door lock type,relay power negatively
connected NO port or NC
port. Note: Maximum load of relay contact is 2A
Gate sensor
IN
GND
Check door open/close status, input
Exit
button
PUSH1
GND
Press the button,door opening control signal,input
Serial
RX
TX
RS232
Output power
5V
GND
Support device external output 5V
Wiegand
WG_D1
WG_D0
GND
Wiegand output interface, support 26bit / 34bit protocol
Input power
GND
12V+
Power input:12V DC
Temperature
measureme
nt module
Operating
temperatur
e
0℃~ +55℃
Storage
temperatur
e
-20℃~ +65℃

Attention:
The following only describes the serial temperature measurement module
No description about I²C interface temperature measurement module, the shape is rectangular
forbidden to use under strong light and direct sunlight;
Suggest indoor use, or semi-outdoor environment, outdoor temperature measurement is affected by the external
environment;
Power
consumption
< 0.3w
Basic
Parameters
Pixel
32*32 Real-time temperature output
Measurement
accuracy
I + 0.5℃
Measuring
distance
0.3 ~ 1.0m
WIFI
2.4G 802.11b/g/n
Bluetooth
BluetooH4.0

Wall Mounting Type Product Picture

Wall-mounted version shape and size(275.8mm*123.8mm*30.2mm)

Indication of Appearance and Wiring Instructions
The front part of the access control machine

Access control wall-mounted version-wiring instructions

Installation Steps
Installation of access control wall-mounted version
Description of the size of the wall bracket;
Note: The product packaging comes with 86 boxes of machine screws and plastic expansion
screws;

Description of the installation location of the wall bracket;

Fixing method of hanging bracket and product terminal
Note: Use three set screws M3 * 5 to fix the terminal. There are matching screws in the
package.

Wiring operation instructions (take the turnstile wiring as an example, other wiring can take this as
reference)
(1) Strip the signal wire (use a wire stripper and other tools) to expose the metal wire, about 5mm, if
possible, add solder, as shown in the figure;
(2) Loosen the screws at each corresponding interface, insert the metal wire end into the hole, tighten the
screws to fix, and do a tensile test after locking to ensure stability, as shown in the figure;
Packing and usage instruction
Materials and tools list
Serial
number
Material / tool name
Quantity
Explanation
1
Host and its
accessories
own
1
Comes with accessories including:
adapter, wall bracket, expansion
self-tapping screws, allen wrench,
screws, etc.
12V
tube,
allen
2
Exit switch (optional)
1
Use when exit (no need for more if it
already exists)
3
Electromagnetic
(optional)
lock
1
Open the door after power off, and lock
when power on (no need for more if it
already exists)

4
Magnetic lock power
supply (optional)
1
Supply power to electromagnetic lock, and
also can supply power to Uface host at the
same time
(If you already have it, you don't need more)
5
Network cable (optional)
Several
Used to arrange Ethernet and other wiring
6
Network cable pliers,
network tester, diagonal
pliers, electrical tape,
wire buckle
Several
Used to arrange Ethernet and other wiring
7
Drilling tools
Several
Used for equipment installation and wiring
Magnetic Door Wiring
1. Schematic diagram of magnetic door system installation;

2. Schematic diagram of magnetic door system wiring:
Installation Notice:
1. During wiring, if the 12V power supply line of the host does not use the "special power supply extension
line" and the distance is long, the cable equivalent resistance will be too high, then it is possible to occur:
terminal insufficient voltage (≤11V), repeated restart of the host, and crash phenomenon。
2. The device has a built-in relay device. The maximum load voltage of the magnetic lock (or other access
control unit) cannot exceed DC12V, and the maximum current cannot exceed 3A. If it exceeds, it will break
the relay and cause the door to fail to open.
3.The device comes with a power adapter as shown in the figure, with a total length of 1 meter. Its weak
current part is 40cm and the high voltage part is 40cm.

The extension of the power cord (weak current part) should not exceed 3 meters, otherwise it will cause
insufficient power supply to the host, and abnormal phenomena such as repeated restarts and crashes. If
the power supply is far away from the device, the power cord (strong electric part) can be extended.。
If you use other adapters, such as 9V and 1A, insufficient voltage and low current will cause the device to restart repeatedly.
The cable used should not be too thin (such as a thin network cable), it is recommended to connect multiple strands of the same cable in
parallel or use thick copper cables to ensure that the voltage > 11V
Note: If using a network cable, please use 4 strands of network cable as the positive pole and 4 strands as the negativepole.
If it is not clear how to extend, please contact the supplier to replace the "dedicated power extension cable".
Table of contents