Supplied By www.heating spares.co Tel. 0161 620 6677
ESCAPE OF GAS
Should a gas leak be suspected, contact your gas
supplier without delay.
Do NOT search for gas leaks with a naked flame.
WARNING: This appliance must be earthed. Do not touch
or tamper with this sealed unit or its components.
1. INTRODUCTION
1.1 Please carefully read information given in the booklet to
help you again maximum control from your appliance
with minimum trouble and cost.
1.1.1 Your Ravenheat Condensing Low Nox Combination
Boiler has been designed to supply your Central
Heating and Domestic Hot Water directly from one
unit. When Central Heating is operating, the circulation
will be interrupted when Domestic Hot Water is being
drawn off.
This will normally not affect the level of Heating.
PLEASE NOTE
Due to the high efficiency and resulting low flue gas
exhaust temperature a white plume of condensation
vapour (cool steam) will be emitted from the flue outlet
terminal, this is quite normal. It will be particularly evident
during periods of low outdoor temparatureor when the
boiler is working at its optimum performance
(Plume Management kit is available on request)
1.2 CLEARANCES AROUND THE BOILER
Above 125 mm ( 5 inches)
Below 150 mm ( 6 inches)
Front 450 mm (18 inches)
Sides 5 mm (0.2 inches)
25mm (1inch) in front when installed in a cupboard
1.2.1 Minimum clearences are required for safety and
maintenance. Do NOT obstruct any purpose made
ventilation opening if boiler has been fitted in a
compartment.
Never hang clothes,ect, over the appliance
1.3 USER CONTROLS (Fig.1)
1.3.1 This appliance is designed to operate with the
minimum of attention by the User. All the controls
are to be found on the control pannel.
1.4 OPERATING SAFETY CHECKS TO PROTECT
YOUR APPLIANCE
1.4.1 Before lighting theAppliance check Central Heating
system pressure (Fig.1 item 7) is not less than 1
bar. If it is below this do not light but consult your
installer about refilling your system as you may
have a leak in the system.
1.4.2 In the event of malfunction of the appliance will be
indicate by the relevant error code (Table1) on
Digital Display of the control panel (Fig.50).
These can be Reset by press a RESET button .
If lockout code persist leave the appliance shut
down and consult your installer/service
engineer immediately.
Table 1
USER’S GUIDE
CSI 120(T) Low Nox (with or without built in timer)
CONDENSING LOW NOX SYSTEM INNOVATION SUPER HIGH EFFICIENTY AUTOMATIC
MODULATING COMBINATION BOILER FOR CENTRAL HEATING AND DOMESTIC HOT WATER
It is the law that all gas appliances are installed by
a competent person, in accordance with the gas
safety installation and use current regulations.To
the current Gas Safety (Installation and Use)
Regulations B.S.5440:2-(2000).
All CORGI registered installers carry a CORGI ID card and
have a registration number. Both should be recorded in your
boiler Log book. You can check your installer by calling
CORGI direct on 01256 732300.
01: Lock out from the Flame Control Unit
02: Flue System obstruction
04: Overheat Lockout
06: Open or short circuit on Sanitary probe
12: Open or short circuit on Heating probe
14: Flame simulation on Flame Control Unit
17: Fault on Fan Control
28: Water Flow Switch Fault or low pressure
in the heating system
1
Supplied By www.heating spares.co Tel. 0161 620 6677
3.3 TO SHUT DOWN THEAPPLIANCE
3.3.1 For short periods, switch Summer/Winter switch to
Summer and turn off all hot taps.
For long periods switch of the on/off switch (Fig.1).
If the appliance is to be shut down for long periods
when there is a risk of freezing, then appliance
should be drained . Similar refilling must be done
by a competent person following approved
procedure.
4. CLEANING OF APPLIANCE OUTER CASING
4.1 Use a clean damp cloth. Do not use any abrasive
cleaners and with a dry cloth lightly polish to protect
painted surfaces.
Control Panel and fixiture can be wiped with damp
cloth and dried . Spray polishes must not be used on
control panel surfaces or switches.
Care must be taken in preventing any liquids
entering the appliance.
5. CARE OF YOUR APPLIANCEAND SYSTEM
5.1 Annual servicing of your appliance is required to
maintain safety and efficiency of its operation.
therefore it is reccommended that the appliance
is serviced at least once a year and that the whole
of the Heating System be checked at the same time
by a qualified installer. If it is know or suspected that
a fault exists on the boiler then it MUST NOTbe
used untill the fault has been corrected by a
COMPETENT PERSON. It is essential that the
Instructions in this booklet are strictly followed for safe
and economic operation of the boiler.
SERVICING SHOULD BE CARRIED OUT BY
A QUALIFIED INSTALLER
Ravenheat Manufacturing Ltd
Chartists Way , Morley , Leeds
LS 27 9ET
2
2. OPERATING DOMESTIC HOT WATER
2.1 Select summer / Winter switch on Summer position
2.2 Open hot water tap.After about 3 secondsburner will
always operate.
2.3 Temperature of Domestic Hot Water can be varied by
adjusting the water flow rate at the Domestic Hot water
The temperature can be set between minimum ( 40°C)
and Maximum (60°C).
For maximum temerature of Domestic Hot Water leave
the control Knob on Maximum position.
3. OPERATING HEATING AND HOT WATER
3.1 TO SETANDADJUST BUILT-IN TIMER MODEL SEE
OPPOSITE PAGE 3
3.2 Select Summer/Winter Switch on Winter position
3.3 Switch on timeclock, adjust room stat and/or thermostatic
radiator valves to hogh settings
3.4 Burner will operate, temparature output of Central
Heating can be adjusted by Central Heating Control
Knob(Fig.1). The Knob can be set between
minimum(40°C) and Maximum(85°C).While the
appliance is being used to provide Domestic Hot water,
the Central Heating will not operate.When Domestic
Hot Water is not longer required the appliance will
automatically revert to Central Heating and should not
noticeably affect the level of central heating.
Adjust external controls required settings.
NOTE :AnAnti-cycling device is fitted to the Heating Function.
When the boiler reaches its set Maximum temperature it
will not operate on heating for about 10 minutes , but if
the heating temperature return goes 20°C below the set
point, the burner will restarts immediately.
The domestic Hot Water Function will always operate on
demand.
Fig.1
min Max
min
Max
Supplied By www.heating spares.co Tel. 0161 620 6677
3
Supplied By www.heating spares.co Tel. 0161 620 6677
COD 0017FOG11005/0 - 10/2005
Chartists Way, Morley, Leeds, LS27 9ET
Telephone : 0044(0)113 252 7007
Tfax : 0044(0)113 238 0229
Website : www.ravenheat.co.uk E-mail : [email protected]
Ravenheat reserves the right to make changes and
improvements in our products which may affect the accuracy
of the information contained in this leaflet.
4

This manual suits for next models

1

Other Ravenheat Boiler manuals

Ravenheat RSF 84ET User manual

Ravenheat

Ravenheat RSF 84ET User manual

Ravenheat HE 85 A User guide

Ravenheat

Ravenheat HE 85 A User guide

Ravenheat CSI 85 B User manual

Ravenheat

Ravenheat CSI 85 B User manual

Ravenheat CSI SYSTEM AAA T 780 Series User manual

Ravenheat

Ravenheat CSI SYSTEM AAA T 780 Series User manual

Ravenheat CSI 120 User manual

Ravenheat

Ravenheat CSI 120 User manual

Ravenheat Little Star LS 80 User guide

Ravenheat

Ravenheat Little Star LS 80 User guide

Ravenheat HE 80 T Operating manual

Ravenheat

Ravenheat HE 80 T Operating manual

Ravenheat RSF 84E User guide

Ravenheat

Ravenheat RSF 84E User guide

Ravenheat CSI PRIMARY AAA User manual

Ravenheat

Ravenheat CSI PRIMARY AAA User manual

Ravenheat HE 120N Technical manual

Ravenheat

Ravenheat HE 120N Technical manual

Ravenheat CS 80 T Operating manual

Ravenheat

Ravenheat CS 80 T Operating manual

Ravenheat HE 80 S Operating manual

Ravenheat

Ravenheat HE 80 S Operating manual

Ravenheat Flue Boiler User guide

Ravenheat

Ravenheat Flue Boiler User guide

Ravenheat CSI 85 User guide

Ravenheat

Ravenheat CSI 85 User guide

Ravenheat HE 25 C COMPACT Operating manual

Ravenheat

Ravenheat HE 25 C COMPACT Operating manual

Ravenheat RSF 82E User guide

Ravenheat

Ravenheat RSF 82E User guide

Ravenheat RSF 82ET User manual

Ravenheat

Ravenheat RSF 82ET User manual

Ravenheat Little Star LS 80 User manual

Ravenheat

Ravenheat Little Star LS 80 User manual

Ravenheat HE 25 S COMPACT Operating manual

Ravenheat

Ravenheat HE 25 S COMPACT Operating manual

Ravenheat CS 80 Operating manual

Ravenheat

Ravenheat CS 80 Operating manual

Ravenheat HE Primary AAA Operating manual

Ravenheat

Ravenheat HE Primary AAA Operating manual

Ravenheat RSF 82ET User manual

Ravenheat

Ravenheat RSF 82ET User manual

Ravenheat 780 Series Operating manual

Ravenheat

Ravenheat 780 Series Operating manual

Ravenheat CSI85A(T) User guide

Ravenheat

Ravenheat CSI85A(T) User guide

Popular Boiler manuals by other brands

Bonnet OPTIMUM 700 manual

Bonnet

Bonnet OPTIMUM 700 manual

TriangleTube Prestige Solo Installation and maintenance manual

TriangleTube

TriangleTube Prestige Solo Installation and maintenance manual

Unical TRISECAL 3P Series INSTALLATION, USE AND SERVICING INSTRUCTION

Unical

Unical TRISECAL 3P Series INSTALLATION, USE AND SERVICING INSTRUCTION

VOKERA Rain24 Installation and servicing instructions

VOKERA

VOKERA Rain24 Installation and servicing instructions

Viessmann Vitotron 100 Installation and service instructions

Viessmann

Viessmann Vitotron 100 Installation and service instructions

Viessmann VITOROND 200 Service instructions

Viessmann

Viessmann VITOROND 200 Service instructions

Ideal Boilers Logic+ Combi 24 user guide

Ideal Boilers

Ideal Boilers Logic+ Combi 24 user guide

New Yorker M Installation, operating and service instructions

New Yorker

New Yorker M Installation, operating and service instructions

Biasi Activ A 250V User manual and installation instructions

Biasi

Biasi Activ A 250V User manual and installation instructions

UTICA BOILERS UH16 Series Installation, operation & maintenance manual

UTICA BOILERS

UTICA BOILERS UH16 Series Installation, operation & maintenance manual

HydroTherm KN-2 installation instructions

HydroTherm

HydroTherm KN-2 installation instructions

Navien NCB-20LHWE Installation & operation manual

Navien

Navien NCB-20LHWE Installation & operation manual

Immergas INTEC 30 System External Installation instructions manual

Immergas

Immergas INTEC 30 System External Installation instructions manual

Baxi Nuvola 3 Comfort Operating and installation instructions

Baxi

Baxi Nuvola 3 Comfort Operating and installation instructions

ECR Olsen OMGB II Series Installation, operation & maintenance manual

ECR

ECR Olsen OMGB II Series Installation, operation & maintenance manual

Knight WH-056 User's information manual

Knight

Knight WH-056 User's information manual

Windhager BioWIN series operating manual

Windhager

Windhager BioWIN series operating manual

Smith GVX User's information manual

Smith

Smith GVX User's information manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.