Reborn Endo Expert User manual

1
Multifunctional Endo Motor
Instruction Manual
Guangzhou RebornEndo Medical Instrument Co., Ltd.
https://stomshop.pro/

2
Thank you for purchasing Multifunctional Endo Motor.
If you encounter any questions or problems while reading this manual,
please contact the device manufacturer immediately.
Please read this manual before operating, and keep this manual for
future reference. As the manufacturer of this device,Guangzhou RebornEndo
Medical Instrument Co., Ltd. reserves the rights to modify the informations
and datas contained in this instruction manual at any time without advance
notice.
We try our best to compile this instruction manual, if it still involves
any incorrections, please feel free to contact us directly.
Guangzhou RebornEndo Medical Instrument Co., Ltd.
Registrant/Manufacturer/After-sales Service Unit:
Guangzhou RebornEndo Medical Instrument Co., Ltd.
Residence/Production Address :Room 309, Building No.5, No.2, Xingye
Road, Nansha District, Guangzhou City, Guangdong Province, China.
Tel/Fax:020-31062832
https://stomshop.pro/

3
Contents
1 Product Description ............................................................................................ 5
1.1 Preface ......................................................................................................5
1.2 Product Introduction ................................................................................ 5
1.3 Model and Specification .......................................................................... 6
1.4 Performance and composition ................................................................. 6
1.5 Scope Of Application ...............................................................................6
1.6 Contraindications ..................................................................................... 6
1.7 Warning .................................................................................................... 6
1.8 Instrument Safety Classification ..............................................................7
1.9 The Main Technical Parameters .............................................................. 7
2 Functional Overview ...........................................................................................8
2.1 Operation Mode And Memory Mode ...................................................... 8
2.1.1 Optimum Glide Path Function(OGP)..................................... 8
2.1.2 Optimum Torque Reverse Function(OTR)............................. 9
2.2 Memory Mode ....................................................................................... 10
2.2.1 Self-defined Mode & Preset File-parameter Mode .................... 10
2.2.2 SGP(T-Mode)........................................................................ 13
2.2.3 AIC Full Automatic function ...................................................... 13
2.2.4 The way to call preset parameters of file ................................... 13
2.2.5 The way to call parameters of removing broken file ................. 14
3 Symbol instruction ............................................................................................ 16
4 Parts Identification and Display Screens .......................................................... 17
4.1 Parts Identification .................................................................................17
4.2 Components and Accessories ................................................................ 17
5 Operation ...........................................................................................................17
5.1 Before Use ............................................................................................. 17
5.1.1 Product Installation .....................................................................17
5.1.2 Calibration .................................................................................. 19
5.2 In use ......................................................................................................19
5.2.1 Operation of self-defined Mode ................................................. 19
https://stomshop.pro/

4
5.2.2 Preset file-parameter mode ......................................................27
5.2.3 Advanced mode setting ............................................................27
5.3 After Use ................................................................................................ 29
5.3.1 Regular Inspection ...................................................................... 29
5.3.2 Maintenance ................................................................................30
6 Troubleshooting ................................................................................................ 33
7 Safety precautions .............................................................................................35
https://stomshop.pro/

5
1 Product Description
1.1 Preface
Guangzhou RebornEndo Medical Instrument Co., Ltd was founded in 2016.
It is a high-tech enterprise which has a professional R& D and sales team in
dental root canal treatment fields.
The company is located in China Pilot Free Trade Zone: Nansha New
District, Guangzhou, which is adjacent to the core regional resources of the
Guangdong-Hong Kong-Macao Greater Bay Area.The ideal place provides an
excellent convenience for business trades. Since its establishment, the company
insists on the development concep of customer obsess and perfect quality
products. It provides a perfect root canal solutions for global dentists.
RebornEndo has built a young and energetic team which focus on high-standard
design, R&D, developing, and producing dental products. RebornEndo products
have obtained the international quality certification: ISO、CE and CFDA.
1.2 Product Introduction
Multifunctional Endo Motor is a medical device for dentists to perform
endodontic treatment. It can be used as a Endo Motor for preparation and
enlargement of root canals, or device for measuring canal length. It can be used
to enlarge the canals while monitoring the position of the file tip inside the
canal.
The main features of the devices are:
No.
Features
Models
1
Cordless portable endo motor
with combined length
determination.
R-Smart Pro、R-Smart Expert、R-Smart Classic、
R-Smart W-Pro、R-Smart W-Expert、R-Smart W-Classic
2
Intelligent matrix
anti-interference apex
locating algorithm.
R-Smart Pro、R-Smart Expert、R-Smart Classic、
R-Smart W-Pro、R-Smart W-Expert、R-Smart W-Classic
3
360 degrees rotation of contra
angle.
R-Smart Pro、R-Smart Expert、R-Smart Classic、
R-Smart W-Pro、
R-Smart W-Expert、
R-Smart W-Classic
4
AIC automatic intelligent
adaptive system algorithm.
R-Smart Pro、R-Smart Expert、
R-Smart W-Pro、R-Smart W-Expert
5
RBF mode to remove the
broken file in the cannal root.
R-Smart Pro、R-Smart Expert、
R-Smart W-Pro、R-Smart W-Expert
6
Bluetooth data transmission.
R-Smart Pro、R-Smart W-Pro
7
Optimum apical action.
R-Smart Pro、R-Smart W-Pro
8
Optimum Glide Path
Function.
R-Smart Pro、R-Smart W-Pro
9
Optimal self-adaption and
trigger torque mode.
R-Smart Pro、R-Smart W-Pro
https://stomshop.pro/

6
1.3 Model and Specification
R-Smart Pro、R-Smart Expert、R-Smart Classic:Wired charging, the
device can be charged through electric contact.
R-Smart W-Pro、R-Smart W-Expert、R-Smart W-Classic:Wireless
charging, the device can be charged through an induction coil.
Product Size:27.5mm*29.1mm*202.1mm.
Product Weight:158.3g.
1.4 Performance and composition
The device is composed of charging base, motor handpiece, contra angle,
measuring wire, lip hook, file clip, power adapter, etc.
1.5 Scope Of Application
The device can be used for preparation and enlargement of root canals, or
device for measuring canal length.
It can only be used by professional dentists in hospital environment, clinic
in accordance with national regulations.
1.6 Contraindications
It is forbidden to use this instrument in the following situations:
1.6.1 The doctor with a pacemaker is disabled.
1.6.2 Patients with cardiac pacemakers (or other electrical equipment) are
warned not to use small appliances (such as Electric razors, hair dryers, etc.)
patients are disabled.
1.6.3 Hemophilia patients are banned.
1.6.4 Use with caution in patients with heart disease, pregnant women and
young children.
1.7 Warning
This section contains descriptions of serious side effects and potential
safety risks for the product itself and users/patients. The following warning
clauses must be read before use:
1.7.1 The instrument can only be used by professional dentists in
accordance with national regulations.
1.7.2 The instrument can only be used in designated places and cannot be
used outdoors.
1.7.3 The instrument requires special precautions regarding
electromagnetic compatibility (EMC) and must be in strict accordance with the
EMC information for installation and use. Do not use this equipment especially
in the vicinity of fluorescent lamps, radio transmitting devices, remote control
devices, handheld and mobile high frequency communication devices.
1.7.4 It is forbidden to expose the instrument directly or indirectly to a heat
source. The instrument must be operated and stored in a safe environment.
1.7.5 It is forbidden to use it under conditions with flammable anesthetic
https://stomshop.pro/

7
mixtures.
1.7.6 Do not immerse it in liquid.
1.7.7 Only suitable for original accessories.
1.7.8 Please use original power adapter. Other power adapter will result in
damage to lithium battery and control circuit.
1.7.9 Do not use damaged or defective instruments.
1.7.10 Do not carry out any repairs or modifications without authorization.
In case of failure, please contact your local dealer and do not allow unauthorized
personnel to repair.
1.7.11 Please do not make any changes to the device. Any changes may
violate safety regulations, causing harm to the patient. There will be no promises
of any modification.
1.7.12 Please confirm whether the file is well installed and locked before
starting the motor handpiece.
1.7.13 The instrument complies with electromagnetic compatibility
standards, but it is still necessary to prevent possible risks caused by
electromagnetic interference.
1.7.14 Please remove the battery if the motor handpiece is not likely to be
used for some time.
1.8 Instrument Safety Classification
1.8.1 Type of operation mode: Continuous operating device.
1.8.2 Type of protection against electric shock: Class II equipment with
internal power supply.
1.8.3 Degree of protection against electric shock: B type applied part.
1.8.4 Degree of protection against harmful ingress of water: Ordinary
equipment (IPX0).
1.8.5 Degree of safety application in the presence of a flammable anesthetic
mixture with air, oxygen, or nitrous oxide: Equipment cannot be used in the
presence of a flammable anesthetic mixture with air, oxygen, or nitrous oxide.
1.9 The Main Technical Parameters
1.9.1 Lithium battery:3.7V/ 1500mAh
1.9.2 Power Adapter:
Input:~100V-240V 50Hz/60Hz 0.5A
Output:DC 5V/ 2A
1.9.3 Speed rang:100-1000rpm
1.9.4 Torque rang:0.4~5.0 N.cm
1.9.5 Adapter fuse: T2AL250V
1.9.6 The shaft of the instrument used with the contra-angle handpiece
conforms to YY/T 0967, type 1 rod, with a diameter of 2.35mm, a minimum
https://stomshop.pro/

8
matching length of 9mm, and a maximum total length of the bur 33mm. The
gear ratio is 16:1.
1.9.7 Environment parameters:
1)Environment temperature: 0~40℃
2)Relative Humidity:10~85%RH
3)Atmospheric pressure:70kPa~106kPa
2 Functional Overview
This device provides root canal enlargement and root canal length
measurement functions for root canal treatment. The treatment objects are
divided into ordinary root canals and complex root canals.
2.1 Operation Mode And Memory Mode
The device provides 5 operation modes, which can be operated and used
according to the user’s expected needs. The 5 operation modes and application
scenarios are:
2.1.1 Optimum Glide Path Function(OGP)
https://stomshop.pro/

9
Optimum Glide Path Function(OGP)(only available for R-Smart Pro、
R-Smart W-Pro):
A Motion:
180°clockwise, and then 180°anti-clockwise reverse rotation.
B Motion:
180°clockwise, and then 270°anti-clockwise reverse rotation.
Repeat the watch-winding (A) motion and balanced force (B) motion.
OGP can be setted the status (ON/OFF) in REC mode.
If the OGP function is the ‘ON’ status,the instrument operates according to
the motion mode of OGP mentioned above. In this case, the instrument can not
set the forward and reverse rotation angles.
If the OGP function is the ‘OFF ’status,the instrument can set the forward
and reverse rotation angles. Adjustment range of forward / reverse
rotation angle:30 °- 370 °. It can increase or decrease the angle
by pressing ‘ <’ / ‘> ’.
The angle adjustment step value is 10 °. It is recommended that the sum of
forward rotation angle and reverse rotation angle should be greater than or equal
to 120 °.
OGP is applicable to W-One/ R-One ( R3 Endo File ) produced by the
equipment manufacturer or other similar Endo File.
2.1.2 Optimum Torque Reverse Function(OTR)
Optimum Torque Reverse Function (OTR )(only available for
R-Smart Pro、R-Smart W-Pro):
Continuous forward rotation normally ( 360°Clockwise rotation) , but when
the load on the file exceeds the set limit, the file automatically starts alternating
between reverse(Motion 1)and forward (Motion 2) rotation (default setting).
When the load on the file belows the set limit again, the file recovery
360°Clockwise rotation.
Motion 1:
90°anti-clockwise reverse rotation.
Motion 2:
180°clockwise rotation.
https://stomshop.pro/

10
OTR can be setted the status (ON/OFF) in ATC mode.
If the OTR function is the ‘ON’ status,the instrument operates according to
the motion mode of OTR mentioned above.In this case, the instrument can not
set the forward and reverse rotation angles.
If the OTR function is the ‘OFF’status,the instrument can set the forward
and reverse rotation angles. Adjustment range of forward / reverse rotation
angle:30°- 370°. It can increase or decrease the angle by pressing ‘<’ / ‘>’.
The angle adjustment step value is 10 °. It is recommended that the sum of
forward rotation angle and reverse rotation angle should be greater than or equal
to 120 °.
OTR is applicable to W-One/ R-One ( R3 Endo File ) produced by the
equipment manufacturer or other similar Endo File.
2.2 Memory Mode
2.2.1 Self-defined Mode & Preset File-parameter Mode
The mode of R-Smart Pro、R-Smart W-Pro
This equipment is designed with 18 memory modes (11 self-defined modes
and 7 preset file-parameter modes) .
M0 to M10 memory mode are self-defined modes.
The 11 self-defined modes can complete a whole endo treatment.
Especially, almost all canals can be treated with the default settings of the
memories from M0 to M3. However, settings can be changed to suit various
stages of treatment.We recommend using the default settings until the user has
gotten used to how the instrument works.
Memory
mode
Main uses with default
setting
Operation
mode
Applicable scene
Default
speed (rpm)
Default
torque
(Ncm)
M0
Canal measurement
EAL
Apex locating
—
—
M1
Shape the upper part of the
canal
CW
Treatment of normal canal
300
3.0
M2
Negotiation and making a
glide path for
a normal canal
REC
Treatment of normal canal
300
2.0
M3
Canal shaping for a normal
canal
ATC
Treatment of normal canal
300
1.0
M4
Negotiation and making a
glide path for
a complex canal
REC
Treatment of complex canal
100
2.0
M5
Making a glide path for a
complex canal
REC
Treatment of complex canal
300
2.5
M6
Canal shaping for a
complex canal
ATC
Treatment of complex canal
300
1.0
https://stomshop.pro/

11
M7
Injection solutions such as
calcium hydroxide, etc
CCW
Injection solutions
200
2.5
M8
SGP
T-Mode
Elimination of root canal
steps
300
(SGP
spped)
/
M9
Full Automatic mode
AIC
AIC automatic intelligent
adaptive system algorithm
—
—
M10
Remove Broken File mode
RBF
Remove the broken file in
the root canal
500
3.0
M11
Preset File-parameter Mode
CW
Store file parameters of
RebornEndo
300
3.0
M12
Preset File-parameter Mode
REC
Store file parameters of main
brands and RebornEndo
300
2.5
M13
Preset File-parameter Mode
REC
Store file parameters of main
brands and RebornEndo
300
2.5
M14
Preset File-parameter Mode
REC
Store file parameters of main
brands and RebornEndo
300
2.5
M15
Preset File-parameter Mode
REC
Store file parameters of main
brands and RebornEndo
350
2.0
M16
Preset File-parameter Mode
REC
Store file parameters of main
brands and RebornEndo
350
2.0
M17
Preset File-parameter Mode
REC
Store file parameters of main
brands and RebornEndo
350
2.0
M9: Full Automatic mode. Operator can refer to this manual (chapter:2.2.2)
for details.
M10: Remove Broken File mode. Operator can refer to this manual
(chapter:2.2.4) for details.
M11 to M17 memory mode are preset file-parameter modes.
The 7 preset file-parameter modes are used to store file parameters of main
brands by a cloud storage system, which is convenient for users to call
parameters store according to their needs.
The mode of R-Smart Expert、R-Smart W-Expert
Memory
mode
Main uses with default
setting
Operation
mode
Applicable scene
Default
speed (rpm)
Default
torque
(Ncm)
M0
Canal measurement
EAL
Apex locating
—
—
M1
Shape the upper part of the
canal
CW
Treatment of normal canal
300
3.0
M2
Negotiation and making a
glide path for
a normal canal
REC
Treatment of normal canal
300
2.0
M3
Canal shaping for a normal
canal
ATC
Treatment of normal canal
300
1.0
M4
Negotiation and making a
glide path for
a complex canal
REC
Treatment of complex canal
100
2.0
https://stomshop.pro/

12
M5
Making a glide path for a
complex canal
REC
Treatment of complex canal
300
2.5
M6
Canal shaping for a
complex canal
ATC
Treatment of complex canal
300
1.0
M7
Injection solutions such as
calcium hydroxide, etc
CCW
Injection solutions
200
2.5
M8
Preparation with one file
REC
Preparation with one file
300
3.0
M9
Full Automatic mode
AIC
AIC automatic intelligent
adaptive system algorithm
—
—
M10
Remove Broken File mode
RBF
Remove the broken file in
the root canal
500
3.0
M11
Preset File-parameter Mode
CW
Store file parameters of
RebornEndo
300
3.0
M12
Preset File-parameter Mode
REC
Store file parameters of main
brands and RebornEndo
300
2.5
The mode of R-Smart Classic、R-Smart W-Classic
Memory
mode
Main uses with default
setting
Operation
mode
Applicable scene
Default
speed (rpm)
Default
torque
(Ncm)
M0
Canal measurement
EAL
Apex locating
—
—
M1
Shape the upper part of the
canal
CW
Treatment of normal canal
300
3.0
M2
Negotiation and making a
glide path for
a normal canal
REC
Treatment of normal canal
300
2.0
M3
Canal shaping for a normal
canal
ATC
Treatment of normal canal
300
1.0
M4
Negotiation and making a
glide path for
a complex canal
REC
Treatment of complex canal
100
2.0
M5
Making a glide path for a
complex canal
REC
Treatment of complex canal
300
2.5
M6
Canal shaping for a
complex canal
ATC
Treatment of complex canal
300
1.0
M7
Injection solutions such as
calcium hydroxide, etc
CCW
Injection solutions
200
2.5
M8
Preset File-parameter Mode
CW
Store file parameters of
RebornEndo
300
3.0
M9
Preset File-parameter Mode
REC
Store file parameters of main
brands and RebornEndo
300
2.5
https://stomshop.pro/

13
2.2.2 SGP(T-Mode)
T-Mode is only available for R-Smart Pro、R-Smart W-Pro:
In T-mode, if the main button is triggered for the first time, the motor will
run in SGP mode. If the main button is pressed again, the motor will run in the
mode preset by the user.
2.2.3 AIC Full Automatic function
AIC is only available for R-Smart Pro、
R-Smart W-Pro、
R-Smart Expert、
R-Smart W-Expert:
The AIC function is a Full Automatic mode. It built in a set of AIC
automatic intelligent adaptive system algorithm. It does not need any parameter
settings. Operator can choose the AIC function and uses it immediately.The AIC
function is suitable for 360 ° continuous rotary file at low speed with CW/CCW.
This function is only effective when endo preparing accompanied by root
canal length measurement. When the file keeps 360 °continuous rotation, the
instrument can intelligently analyze and automatically adjust the rotation mode,
speed and torque according to the resistance of the root canal file in the root
canal, different root canal conditions and the position from the apical point
automatically measured. The AIC function meets the requirements of safe and
efficient root canal shaping. And the AIC function set at M8 mode.
2.2.4 The way to call preset parameters of file
The following explains just take R-Smart Pro/ W-Pro for example.
M0-M9:Press and hold the S key for 2 seconds,call the parameters of main
brands endo file (include RebornEndo R3 file and other main brands file) for
choose. After selecting the file parameters, the system will store the selected file
parameters in M12.
M11 :Press and hold the S key for 2 seconds, call the parameters of
RebornEndo R3 file for choose. After selecting the file parameters, the system
will store the selected file parameters in M11.
M12-M17:Press and hold the S key for 2 seconds,call the parameters of
main brands endo file (include RebornEndo R3 file and other main brands file)
for choose. After selecting the file parameters, the system will store the selected
file parameters in the current mdoe program.
https://stomshop.pro/

14
Note:
The parameters stored by default are for reference only.The specific
parameter setting must be based on the actual clinical operation process,
combined with the actual root canal environment, the recommended value of the
file manufacturer, etc.Users need to adjust appropriate parameters and operation
modes according to the actual situation.
The way to call preset parameters of endo file in R-Smart Expert/ W-Expert、
R-Smart Classic/ W-Classic is similar with the above explains.
2.2.5 The way to call parameters of removing broken file
RBF is only available for R-Smart Pro、
R-Smart W-Pro、
R-Smart Expert、
R-Smart W-Expert:
M10 (RBF):M10 stores the parameters of main brand instruments used for
removing broken file.It usually includes the storage of parameters and motion
modes of the instruments of main brands such as G-drill and Ring-drill.The
system will automatically match the corresponding motion mode and store it in
M10. Users do not need any setting parameters.
https://stomshop.pro/

15
https://stomshop.pro/

16
3 Symbol instruction
Switching button
Volume
Modulation
Registered trademark
Indoor Use Only
Direct Current
Cautions! Refer to
attached
documents
Class II Equipment
B type applied
part
Retrieve
Keep Dry
Fragile products
Humidity limit for
storage: 0% ~
85%
Atmospheric pressure for
storage: 70kPa—106kPa
Temperature limit
for storage: 10°C
~ +50°C
Refer To The Instruction
Manual Before Use
134℃
disinfection and
sterilization
Dispose of waste
products and accessories
in accordance with the
"Waste Electronic
Equipment (WEEE)
Directive (2002/96/EC)"
https://stomshop.pro/

17
4 Parts Identification and Display Screens
4.1 Parts Identification
4.2 Components and Accessories
motor handpiece Contra Angle Silicone sleeve Battery
lip hook Probe File Clip Measuring wire Oil filling nozzle
5 Operation
5.1 Before Use
5.1.1 Product Installation
a)Installation of Contra Angle
Align any locating pin of the contra-angle with the positioning slot on the
motor handpiece and push the contra-angle horizontally. The locating pins on
the contra-angle are inserted into those positioning holes on the motor
handpiece. A “click” sound indicates that the installation is in place. The
contra-angle can be rotated 360° freely.
The contra-angle is free to rotate, adapting to the root canal of different
positions, and it is convenient to watch the screen when operating.
Gently pull the contra-angle to ensure that it is firmly installed.If the
connection is not firm, it may cause unpredictable rotation or the contra-angle
may separate.what's worse, it may hurt the patient.
https://stomshop.pro/

18
b)Installation of file
Before starting the device, plug the file into the hole of contra angle head.
Hold down the push button on the contra angle and insert the file. Turn the file
back and forth until it is lined up with interior latch groove and slips into place.
Release the button to lock the file into the contra angle.
Warning:
After plugging the file into contra angle, let
go the hand on push cover to assure that the file
cannot be taken out. Be careful when inserting
files to avoid injury to fingers.Inserting and
removing files without holding the push button
may damage the chuck of contra angle.Please use
files with shanks meet the ISO standard.
Removal of file: Pressing the push cover, and then directly pull out the
file.
Warning:
Before plugging and pulling out the file, the motor handpiece must be
stopped. Be careful when removing files to avoid injury to fingers.Removing
files without holding the push button will damage the chuck of contra angle.
c)Installation of measuring wire
Connect the measuring wire to the motor handpiece. Line up the measuring
wire plug with the notch on the back of the motor and push it all the way
in.Connect the file clip plug into the socket (black) on the measuring wire.
Connect the lip hook to the socket (white) on the measuring wire.
d)Battery Charging
The device can be charged in two ways:
①By host:Plug the DC end of the adapter cable into the charging port of
the host, and charge the device directly.
②By charger:Plug the DC end of the adapter cable into the the charger,
and plug the other end into a power outlet. The Ready LED (green) will light up.
Put the motor handpiece all the way into the battery charger. The Ready
LED (green) will go out and the Charge LED (orange) will light up and start
https://stomshop.pro/

19
charging the motor handpiece.
When the battery is fully charged, the Charge LED (orange) goes out and
the Ready LED (green) will light up.
5.1.2 Calibration
Calibration is automatically performed from 100 to 1,000 r/min.After
calibration, operator can press the main switch key or wait for several
second, and then the instrument will automatically return to the standby screen.
Note:
Calibrate the instrument at the following times:
•Right after purchase.
•Whenever the contra angle has been replaced.
•When using a contra angle other than the one that has been calibrated.
•Whenever, in OTR mode, the instrument always alternates between
forward and reverse rotation and never rotates forward continuously.
5.2 In use
5.2.1 Operation of self-defined Mode
Enter standby statement
Press the main switch key to turn on the instrument. The stand by
display will appear.
Choose language version
The language version can be divided into Chinese
and English.
The operator can press and hold the s key for more
than 4 seconds to switch the language version.
https://stomshop.pro/

20
Switching memory mode
When switching to the required memory mode, It can stay for several
seconds ( according to the habit of the operator) or press the main switch key
to confirm the memory mode of the current interface.
Set the parameters of memory mode
The parameters of the instrument can be set in the case of no load
condition.The parameters including speed, torque, forward rotation angle,
reverse rotation angle, apical action, etc.
The specific parameter setting must be based on the actual clinical
operation process, combined with the actual root canal environment, the
recommended value of the file manufacturer, etc.Users need to adjust
appropriate parameters and operation modes according to the actual situation.
If operator need to set the forward and reverse angles, OGP / OTR should
be turned off. It can refer to the manual for details according to the chapter
2.1.1& 2.1.2.
https://stomshop.pro/
This manual suits for next models
2
Table of contents
Other Reborn Endo Dental Equipment manuals