Reece KADO 250 User manual

KADO
SPECIFICATIONS
Recommended use Domestic, Hotel and Commercial
Material ABS Plastic/Stainless Steel
Colour availability White, Titanium
Fascia Size 326 x 326mm
Weight 3.8kg
Exhaust 50w side ducted
Air Movement 90 L/sec (324m3/H)*
Air Outlet Size 150mm
LED Light 14 watt LED Panel
Cutout Size 296mm diameter round
Min Install Depth 220mm
Install Type AC Plug and lead included
IP Rating IPX4
CLEANING RECOMMENDATIONS
To see the complete KADO range go to
www.reece.com.au/bathrooms
LUX LED EXHAUST FAN 250
We recommend the use of soapy water or approved cleaners.
This product should not be cleaned with abrasive materials.
Damage caused by any improper treatment is not covered by the
product warranty. Refer to Warranty Conditions.
Dimensions are nominal measurements only.
Disclaimer: Products in this specication manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor
reserves the right to vary specications or delete models from their range without prior notication. Dimensions are nominal measurements only.
Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.
Tech Page Version 1
*All Airow data has been gathered in accordance
with International Industry Standards.
PART NO. REECE CODE
REX250WHL White 2053297
REX250SSL Titanium 2053299
Also see:
• REX200WHL/SSL for smaller unit
• REX250WH/SS for no light version
326mm
326mm
274mm
296mm 197mm
145mm
page 1 of 5

KADO
LUX LED EXHAUST FAN 250
AVAILABLE SPARE PARTS AND ACCESSORIES
Part Number Supplier Description
V150DKIT Ventair Ducting Kit with 1 x Ø150mm Grille and 6m Aluminium ducting.
VAD150 Ventair Ø150mm x 6m Aluminium Ducting.
V150PALG Ventair Premium Aluminium External Vent
VTROTIMER Ventair Fully adjustable 1-25min exhaust fan run-on timer.
VTMSENSOR Ventair Infrared motion sensor with 1-5m detection range and 1-20min run-
on timer.
TECHNICAL SPECIFICATIONS
EXHAUST
Air Delivery 90 L/sec (324m3/H)*
Motor Power 50 watts
Noise Level 42dB(A)
Ball Bearing Yes
Duct Outlet Size 150mm
Draft Stopper Yes
LIGHT
Light Type LED Panel Light
Light Wattage 14 watts
Lumens 891Lm
Light Colour (CCT) 4200K Natural White
LED Driver LVS12C40
INSTALLATION
Cut Out Size 296mm Diameter Round
Fascia Size 326 x 326mm
Rec Min Install Depth 220mm
IP Rating IPX4 Splash Resistant
Installation Type AC Plug and Lead Included
Power Supply 220-240V ~50Hz
PACKAGING
Packaging Size 340 x 340 x 340mm
Gross Weight 4.4kg
0
30
50
70
90
110
130
150
170
190
210
Static Pressure (pa)
m3/H 30 60 90 120 150 180 210 240 270 300 330
4m
2m
REX250L
L/sec 8 17 25 33 42 50 58 67 75 83 92
Airflow
Duct Length in
relation to airflow
(approx only)
360
100
10m 8m
6m
REX200L
2m
4m
6m
*All Airow data has been gathered in accordance with International
Industry Standards.
INCLUDES
1 x Exhaust Unit
1 x Cutout Template
page 2 of 5

INSTALLATION INSTRUCTIONS
KADO
LUX LED EXHAUST FAN 250
Please read these instructions carefully before installing and using the product. Keep the instructions handy for future
reference. Electrical wiring must only be done by a licensed electrician and a “Certicate of Compliance” must be issued on
completion of the installation.
LOCATION
The unit must be located and installed in accordance with AS/NZS 3000 and local building codes relating to damp situations.
The unit can be installed in at ceilings with a minimum height of 2 metres. At least 200mm height clearance in the ceiling
cavity is required to ensure sufcient ventilation for moisture to disperse.
Ensure adequate inlets exist through windows, vents or under the door for airow.
Regulations concerning the discharge of air must be fullled.
POWER
AC220~240V, 50Hz electrical supply is required. The unit can be connected to a lighting or power circuit if loading permits.
All electrical work must be carried out in accordance with AS/NZS 3000 or latest edition thereof, and local building codes and
regulations. Ensure that supply power is isolated before commencing installation.
IMPORTANT CONSIDERATIONS
1. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities.
Or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
2. Children should be supervised to ensure that they do not play with the appliance.
3. Fan must be installed at least 1200mm above any hotplate and must have at least 500cm clearance at the exhaust outlet.
4. Do not install fan in locations that may get extremely hot.
5. Ensure the fan has at least 20mm clearance in the ceiling space before installing.
6. Minimum installation height is 2100mm from the oor to the bottom of the exhaust fan.
7. If the room where the fan is to be installed already contains a stove, water heater or a gas re, it is essential to ensure that
air supply to the room is enough for both the fan and the combustion appliance.
8. Please check the appliance has not been damaged during transportation.
9. Check the electrical specications label corresponds to your electrical supply.
10. When using double pole switch connection, the switch must have a minimum 3mm separation on all poles.
11. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similar qualied person in
order to avoid a hazard.
12. When adding duct, avoid bending the duct in the following shapes:
13. Adhere to the latest national wiring rules AS/NZS3000, for wiring and when installing in bathrooms, nearby sinks and water
taps.
14. For the exhaust fan to work effectively, replacement air of volume equivalent to what is being extracted must be able to
enter the room. In general, this air would be drawn under the door or through a slightly open window. If the room is air tight, the
fan will function poorly.
15. Before commencing any cutting, check in the mounting location so that there is no obstruction such as ceiling frames or
joints, and that there is sufcient height clearance for the housing. Check the electrical wiring can be routed from the wall
switch to the mounting location.
16. This fan is not intended for mounting in outside windows or walls.
page 3 of 5

Warning: Ensure the power supply to the exhaust fan is switch OFF before carrying out any
installation and maintenance.
Note: A double pole disconnection switch must be included in the electrical wiring of the
exhaust fan.
1. Check the fan is free to rotate.
2. Cut the hole for the fan according to the template provided.
3. Attach the LED Light:
a. Remove the double sided tape and attach the LED Driver onto the fan body. (See Figure 3a)
b. Plug the fan and LED driver into a socket outlet and pull through the LED output connector with the hole provided. (See Figure 3b)
Note: The two socket outlets and electrical wiring to an ON/OFF wall switch must be pre-installed.
Please arrange a licensed electrician to prepare the socket outlet and an ON/OFF wall switch before carrying out the installation of this fan.
c. Secure the fan body using the three clips, tightening the screws to secure the fan body to the ceiling. Now securely connect the LED
lamp male connector and LED driver connector. (See gure 3c)
d. Push the LED cable connector through the hole so that the connectors are in the ceiling cavity. See Diagram.
4. Secure the panel/fascia by squeezing the spring fasteners and insert into the slot in the fan body. Check that the panel is secured rmly and
closely to the fan body.
LED Lamp and LED driver are replaceable. To replace,
disconnect female and male connectors and replace with
new LED lmap or LED driver.
To avoid overheating, DO NOT cover the
LED driver with roof insulation.
Note: Switch ON the fan and check for
excessive vibration in the fan. If the fan
runs in a sound way without abnormal
noise, then install the panel.
The vent duct should be declined downwards by about 10 degrees.
INSTALLATION INSTRUCTIONS
KADO
LUX LED EXHAUST FAN 250
WARNING: AN ALL-POLE DISCONNECTION MUST BE INCORPORATED INTO THE FIXED WIRING IN ACCORDANCE
WITH THE WIRING RULES AS OUTLINE IN CLAUSE 7.12.2 OF AS/NZS 60335-1 FOR
MEETING THE MINIMUM ELECTRICAL SAFETY OF THIS STANDARD.
ELECTRICAL WIRING
Power ~
Grounding
Brown
Blue
Yellow/Green Terminal
Fuse
Blue
Yellow/Green
Motor
Black or Purple
Brown
Supply N
240VAC L
Earth
Supply N
240VAC L
Earth
LED Light
& Fascia
page 4 of 5
Electricians, please ensure a copy of the installation instructions
is left with the end user for future reference
Figure 3a. Attach the LED Driver
Figure 3b. Pull through connector
Figure 3c. Connect LED connections

KADO
LUX LED EXHAUST FAN 250
REECE PRODUCT QUALITY GUARANTEE
You have purchased a quality product from Reece Pty Ltd
ABN 84 004 097 090 (“Reece”). This product is covered by
a 7 year replacement product warranty including a 24 month
replacement warranty on spare parts (LED light and fascia).
7 YEAR WARRANTY – DOMESTIC USE
This warranty covers faults in the product construction,
material and assembly. Products which are within 7
years from the date of purchase, found upon inspection
by an authorised Reece representative, to be defective
in construction, material or assembly, will be repaired or
exchanged with an equivalent product free of charge.
Replaced items become Reece’s property.
All replacement products will be available for collection
without charge to the customer at the nearest Reece branch
to the customer’s location, or elsewhere as agreed between
the customer and Reece.
24 MONTH WARRANTY - SPARE PARTS
All spare parts which are within 24 months from the date of
purchase, found upon inspection by an authorised Reece
representative, to be defective in construction, material or
assembly, will be replaced free of charge.
Warranty Conditions
This warranty will apply only under all of the following
conditions:
• The item has been installed for and subjected to domestic
residential use only
• Failure is due to a fault in the manufacture of the product
• Proof of purchase (including the date of purchase) is
provided
• The installation of the product is in accordance with the
instructions provided
This warranty does not include faults caused by:
• Unsuitable or improper use
• Incorrect installation or installation not in accordance with
the instructions provided
• Normal wear and tear
• Inadequate or complete lack of maintenance
• Chemical, electrochemical or electrical inuences
• Harsh detergents or abrasive cleaners used on product
nishes
1 YEAR WARRANTY – COMMERCIAL USE
‘Commercial’ use is all use other than for normal domestic
residential purposes, including use in non-business places
as in public buildings, schools, sports centres and in
establishments that contain private bathrooms with high
frequency of use by many individuals, such as hotels, motels,
retirement villages and hospitals.
The Commercial warranty covers this product against
manufacturing faults in the construction, material and
assembly of both the nished products and any spare parts
for a period of 1 year from the date of purchase. Products and
spare parts which are found upon inspection by an authorised
Reece representative to be defective in construction, material
or assembly will be repaired or exchanged free of charge.
Replaced items become Reece’s property. The Warranty
Conditions and exclusions which apply to the domestic use
warranty also apply to this commercial warranty.
EXCLUSIONS
To the fullest extent permitted by law, Reece excludes all
liability for damage or injury to any person, damage to any
property, and any indirect consequential or other loss or
damage.
CLAIM PROCEDURE
For all warranty queries customers are to contact Ventair Pty
Ltd on 1300 665 926 or visit http://ventair.com.au/warranty
Our goods come with guarantees that cannot be excluded
under the Australian Consumer Law. You are entitled
to a replacement or refund for a major failure and for
compensation for any other reasonably foreseeable loss or
damage. You are also entitled to have the goods repaired or
replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
• Make sure the fan is always switched off before cleaning.
• Make sure to use the fan with the specied voltage as
stated on the rating label.
• Use the fan in a dry place, avoid excess humidity and
water.
• Never immerse any part of the fan in water or other liquids.
• Never use petrol benzene or other such chemicals.
• Never allow water to contact the electrical parts such as
switch and motor.
• Never immerse blades or other resin parts in hot water over
60oC.
• Never install the fan in extremely hot environments.
CARE AND MAINTENANCE
page 5 of 5
This manual suits for next models
4
Table of contents
Other Reece Fan manuals
Popular Fan manuals by other brands

Zoo Fans
Zoo Fans H25-EC installation guide

Vortice
Vortice Nordik HVSL Super Blade E Series Instruction booklet

UFESA
UFESA FF0350 instruction manual

Rubine
Rubine RCF-LE800-5BL instruction manual

Monte Carlo Fan Company
Monte Carlo Fan Company 5OBR52 Series owner's manual

Harbor Breeze
Harbor Breeze 41161 manual