Reka EKSVO BSL-MED-1 User manual

St. Petersburg 2012
WATER TREATMENT UNIT
TU 3697-001-27478758-008


WATER TREATMENT UNIT “BSL-MED-1”
© ZAO“REKA” (REKA, JSC), 2012 3
WATER TREATMENT UNIT
“BSL-MED-1”
TU 3697-001-27478758-008
WATER OF PREMIUM QUALITY
Is designed for high quality potable water production
by the method of electrochemical purication
St. Petersburg 2012
Company-developer ZAO “REKA” (REKA, JSC)
oers clear, life-giving, and accessible drink-
ing water of the premium quality in every
house and for every person.

USER MANUAL
4© ZAO“REKA” (REKA, JSC), 2012
“BSL-MED-1” unit (EKSVO)
This is a complex unit where water purication is carried out by an electrochemical
method at the molecular level, which allows to obtain biologically active water
with unique characteristics and balanced in mineral composition. It removes
harmful substances, as well as bacteria, viruses and protozoa while all
the necessary substances that are benecial to the human body (potassium,
magnesium, sodium, calcium, chloride, phosphate, carbonate, etc.) remain in
the puried water. The resulting water has antioxidant properties, stimulates the
removal of free radicals from the body. Unlike conventional lters using sorption,
- and ion exchange membrane technology, water treatment by electrochemical
method has several advantages:
• Robust disinfection. Emitted ozone and atomic oxygen kill all bacteria,
viruses and protozoa in the treated water under the inuence of the electric
eld.
• Improvement of consumer properties such as smell, transparency, color
and taste of drinking water and food prepared on its basis.
• Preservation of mineral composition. Substances which are necessary
and benecial to the human body (such as potassium, magnesium, sodium,
calcium, chlorides, phosphates, carbonates, etc. - specic for the location
you live in ) are not removed but remain in the puried drinking water
unchanged and are actively involved in the metabolism processes.
• Retention of a permanent quality of drinking water purication during
the entire period of the unit operation.
• Heavy metal salts, organic and mineral impurities are removed from
the treated drinking water; compared to conventional lters and sorption
technologies, they are not accumulated but are regularly removed.
• The quality of treated and puried drinking water stays constantly high.

WATER TREATMENT UNIT “BSL-MED-1”
© ZAO“REKA” (REKA, JSC), 2012 5
TABLE OF CONTENTS
1. Attention.................................................................................................................................. 4
2. Safety measures .................................................................................................................... 4
3. Principles of operations...................................................................................................... 5
4. Preparation and order of operations............................................................................. 12
4.1 Preaparation for operation ........................................................................................ 12
4.2 Sequence of actions ..................................................................................................... 13
5. Maintenance........................................................................................................................... 16
Regeneration.......................................................................................................................... 16
Cleaning and change of electrodes............................................................................... 16
6. Possible errors of operation and faults ......................................................................... 17
7. Reminder ................................................................................................................................. 18
8. Technical passport................................................................................................................ 19
Technical specications...................................................................................................... 19
9. Completeness of the set..................................................................................................... 19
10. Transportation and storage............................................................................................ 20
Warranty obligations ............................................................................................................... 21
Certicate of acceptance........................................................................................................ 21
Warranty card ............................................................................................................................. 22
Certication................................................................................................................................. 23
Sanitary-Epidemiological Report ........................................................................................ 24

USER MANUAL
6© ZAO“REKA” (REKA, JSC), 2012
1. ATTENTION :
• Water treatment unit “BSL-MED-1” (EKSVO) is designed for electrochemical
and ltrational water purication for nutritional purposes.
• All parts of the unit are made of materials approved for use in the food industry;
• When you purchase the unit, please check presence of the issued warranty
card;
• Make sure that the unit has complete set and is in salable condition;
Please, read the manual CAREFULLY.
2. SAFETY MEASURES:
IT IS PROHIBITED:
• To use the unit for purposes other than intended, namely, to ll and clean other
liquids dierent from water;
• To operate the unit with mechanical damage of the reactor case, defective control
and power unit or power cord;
• To pull on the power cord when you turn o the unit from the network or turn o
the control and power unit from the reactor;
• To clean the surface of the reactor case, funnel, sludge collection cone, and other
parts using solvents and abrasive agents.
• To open and repair the control and power unit by yourself.
RECOMMENDED:
Remove moisture from the surface of the reactor case, control unit and table with a
napkin before turning the unit on.
!

WATER TREATMENT UNIT “BSL-MED-1”
© ZAO“REKA” (REKA, JSC), 2012 7
3. PRINCIPLES OF OPERATION.
Several dierent ways of active inuence on the treated water are used in the
unit:
• static magnetic eld of weak intensity exposure;
• method of electrochemical coagulation;
• electrootation method;
• ltration method.
METHOD OF MAGNETIC WATER TREATMENT is performed by pouring treated
water through a ring-type permanent magnet embedded into a cap-funnel.
METHOD OF ELECTROCHEMICAL COAGULATION - all harmful substances,
including organic compounds, are actively bound and transformed by aluminum
hydroxide ions into a light foam. The ions are formed during the treatment
process in the reactor.
ELECTROFLOTATION METHOD - atomic oxygen and hydrogen are produced
during the process of turbulent water electrolysis in the reactor, then they gather
in bubbles, and actively bind the already formed foam. This foam (sludge) oats
to the surface of the treated water. It is collected in the end of the process of
electrootocoagulation with a special sludge collection cone. The sludge is
poured out and the sludge collection cone is rinsed out with tap water.
FILTRATION METHOD - treated water is poured from the reactor via the ltering
tank to the collecting tank. The ltering tank contains a ne ltering element for
residual sludge removal.
Water in the collecting tank is ready for consumption. The collecting capacity can
be of any kind (bucket, jar, can, etc.), but it is better to be a glassy one.

USER MANUAL
8© ZAO“REKA” (REKA, JSC), 2012
Figure 1. Reactor.
Cap of the reactor
Case of the reactor
Stand

WATER TREATMENT UNIT “BSL-MED-1”
© ZAO“REKA” (REKA, JSC), 2012 9
2
1
3
4
5
Figure 2. Filtering tank.
1 - ltering tank
2 - ltering element
3 - nut-lock for the ltering element
4 - rubber sealing gasket
5 - polystyrene sealing washer

USER MANUAL
10 © ZAO“REKA” (REKA, JSC), 2012
1
1
3
4
2
2
3
5
6
4
7
Figure 3. Filtering element.
Figure 4. Electrode
Figure 5. Sludge collection cone.
Handle
1 - ltering element cap
2 - big lter-collector
3 - small lter-collector
4 - basis of the ltering element
5 - rubber sealing gasket
6 - polystyrene sealing washer
7 - nut-lock of the ltering element
1 - O-ring
2 - contact lug
3 - wing-nut
4 - screw lock for the reactor stand

WATER TREATMENT UNIT “BSL-MED-1”
© ZAO“REKA” (REKA, JSC), 2012 11
1 - O-ring
2 - contact lug
3 - wing-nut
4 - screw lock for the reactor stand
Fig. 6 Water treatment in the reactor 1 - cap-funnel
2 - reactor
3 - set of electrodes
4 - power supply connector
5 - stand
6 - basis
7 - screw-lock for the reactor basis
Tap water
Water passed through magnetic treatment
Water level mark
Embedded
circular magnet
1
2
4
5
3
6 7

USER MANUAL
12 © ZAO“REKA” (REKA, JSC), 2012
Figure 7. Sludge removal.
1 - sludge collection cone
2 - reactor
Treated water
Sludge
1
2

WATER TREATMENT UNIT “BSL-MED-1”
© ZAO“REKA” (REKA, JSC), 2012 13
1 - ltering tank
2 - ltering element
3 - cap
4 - tank for puried water
2
1
3
4
Water from the reactor
Filtered water
Water treated in the reactor
Puried water
Figure 8. Water ltration.

USER MANUAL
14 © ZAO“REKA” (REKA, JSC), 2012
4. ORDER OF OPERATIONS.
4.1. PREPARATION FOR OPERATION.
• Remove the ltering element (2) from the ltering tank (1) (Fig. 2). To do so,
loosen the nut-lock (3) in the bottom of the ltering tank;
• Take o ltering element cap(1) (Fig. 3), remove lter-collectors (big 2 and
small 3) and place them in a hot solution of 3% acetic acid or citric acid for
10-15 minutes.
• Wipe the inside of the ltering tank (1) (Fig. 2), cap-funnel (1) (Fig. 6), the
reactor tank and the sludge collection cone (Fig. 5), tank for puried water (4)
(Fig. 8) with the same solution.
• Squeeze lter-collectors (2, 3) 8-10 times under running water, then straighten
them and put into the cap of the ltering element consistently, big and small
(Fig. 3).
NOTE: If the ltering element is not used for 2 weeks or more, it is necessary to
perform that procedure again.
• Install the ltering element cap (1) with lter-collectors (2, 3) in place (Fig. 3)
by snapping it into the basis of the ltering element (4).
• Install the ltering element into the ltering tank (Fig. 2).

WATER TREATMENT UNIT “BSL-MED-1”
© ZAO“REKA” (REKA, JSC), 2012 15
!
!
4.2. SEQUENCE OF ACTIONS.
• Take o the cap-funnel (1) (Fig. 6) and remove the sludge collection cone (1)
from the reactor (2) (Fig. 7).
• Flip the cap-funnel and install it onto the reactor (Fig. 6)
• Fill the reactor with tap water through the cap-funnel up to the water level
mark in the form of stripes on the inner wall of the reactor (Fig. 6)
Attention: do not allow water to the control and power unit!
• Remove the cap-funnel from the reactor. Make sure that the water level
reaches the mark on the inner wall of the reactor. If necessary, add some water
or remove.
• Connect the control and power unit cord to the connector on the case of the
reactor, making sure the contact is strong and then insert the plug into the
network ~ 110-220V
Attention: it is necessary to follow the recommended sequence of actions!
• The light indicator (LED) on the control and power unit turns on with red
light and after ~ 2 seconds is ashing green with slow blinking. Bubbling and
intensive formation of foam (sludge) on the top of water (Fig. 6) starts inside
the reactor.

USER MANUAL
16 © ZAO“REKA” (REKA, JSC), 2012
• When the frequency of LED blinking changes from low to high, the water
treatment regime switches from the active process (electrolysis) lasting about
8 minutes to the passive (otation mode) lasting approximately 10 minutes.
When the ashing green LED turns o, the treatment process is completed.
Disconnect the control and power unit from the network and then from the
reactor.
• Take sludge collection cone 1 (Fig. 7) by the handle and put it into the
reactor by matching its slots with guide lugs. Load the sludge collection cone
vertically into the reactor by pressing on the handle gently, so that the cone is
lled with uid (sludge) for about 3/4 of volume.
• Remove the sludge collection cone with the liquid (sludge) strictly vertically from
the reactor (do not spill the sludge).
• Pour the liquid from the sludge collection cone and rinse it on both sides.

WATER TREATMENT UNIT “BSL-MED-1”
© ZAO“REKA” (REKA, JSC), 2012 17
• Pour the treated water from the reactor to the ltering tank. The tank should be pre-
installed on cap 3 (Fig. 8), which closes the tank for puried water 4 (Fig. 8).
• The ltered water is ready for consumption.
• Merge the water remaining after ltering from the ltering tank.
• Rinse the reactor. The unit is ready for the next use.

USER MANUAL
18 © ZAO“REKA” (REKA, JSC), 2012
5. MAINTENANCE
5.1. REGENERATION.
• Depending on the contamination level of the treated water, the lter-collector
elements need to be washed from 2 to 5 times a month in a hot 3% solution of
acetic or citric acid.
• If the unit is used regularly, rinsing should be done under running water, after wich
lter-collectors should be squeezed 8-10 times.
ATTENTION: in case of preservation (non-use) of the unit for over 2 weeks, lter-
collector elements must be stored in a weak solution of vinegar or lemon water.
5.2. CLEANING AND CHANGE OF ELECTRODES.
Regular cleaning of the aluminum plate of the central electrode (anode) (Fig. 4) should
be performed at least once a month. That necessity is caused by the deterioration of the
intensity of the electrolysis process because of the central electrode fouling by a layer of
sludge. For cleaning of the central electrode it is necessary to:
• Turn the reactor tank, remove the stand (6) from the reactor stand (5) by removing
the screw-lock (7) (Fig. 6).
• Unscrew the wing-nut (3) from the central electrode leg and remove the contact
lug (2) (Fig. 4).
• Carefully remove the central electrode out of the electrode set (leave the rubber
sealing gasket on the leg of electrode contact).
• Sand the plate of the central electrode (using abrasive paper, knife, etc.).
ATTENTION: It is strictly forbidden to take out the whole set of electrodes for
cleaning and replacement of the central electrode.
NOTE: if the central electrode got thin and has lost mechanical strength, it should be
replaced by a new one.
• Put the central electrode following guide lugs into the set of electrodes in initial
position.
• Turn the reactor, mount the contact lug to central electrode and apply the wing-
nut to lock.
• Check leak tightness of the reactor by lling it with water.
• Leaks are not allowed.
NOTE: The coagulant, which may occasionally appear in the treated water (depending
on the region where the unit is used), is harmless to human health
!
!

WATER TREATMENT UNIT “BSL-MED-1”
© ZAO“REKA” (REKA, JSC), 2012 19
FOR INFORMATION
1. The most favorable temperature for the cleaning of treated water is +18°C -
+25°C. Water at temperatures below +15°C should be warmed up the above
temperatures.
2. DO NOT FORGET TO DISCONNECT the power cord of power unit from the
220V network upon completion of use of the unit for its intended purpose.
6. POSSIBLE ERRORS OF OPERATION AND FAULTS.
FAULT REASON ACTIONS
The indicator of constant
light is o.
No voltage in the net-
work.
Check the power cord
and socket.
Sludge is not forming on
the top of water while
indicators are on.
No connection in the
slot in the basis of the
reactor.
Check the cord coming
to the reactor and cen-
tral electrode. Check the
connection in the power
and control unit slot.
Slow bubbling, lack of
sludge formation.
Big stratication on the
central electrode.
If necessary, change
or clean the central
electrode.
The unit is not working,
indicators are not ash-
ing.
The power and control
unit is faulty.
Call the service engineer
from the support. Send
the control and power
unit to the manufacturer
repair service.

USER MANUAL
20 © ZAO“REKA” (REKA, JSC), 2012
7. REMINDER.
1. If you wish for any reason to repeat the cycle of water purication, it is necessary to:
• turn o the control and power unit after green light “ashes” with greater
frequency and in 10-15 seconds reconnect the unit to the network;
• perform 2 full consecutive cycles of water purication.
It is undesirable to clean water for more than two times, as this will remove useful
mineral salts from the water.
2. When using a water treatment unit for the rst time, the rst portion of the
treated water from the reactor should be poured into the sink.
3. Water processed in the reactor is extremely rich in atomic oxygen and is very
active. Storing it in a glass container stimulates additional water saturation with
silicon ions, which are so necessary to the human body. When boiling the treated
water, white foam may form on its surface - that is the oxygen component. You
should not be confused by that.
4. To prevent damage of the bottom of the ltering tank (Fig. 2) when xing the
ltering element (collector) in it, screw the wing-nut with no eort, until the full
t of the ltering element (collector) to the tank bottom.
5. If the treated water contains very little natural salt (is soft), it is necessary to add
to the reactor a pinch of kitchen salt before processing.
6. Snow and distilled water cannot be cleaned in the unit, due to their zero
conductivity.
7. Sludge formed in the process of water purication is an excellent fertilizer
stimulant for any plant.
!
Table of contents
Popular Water Filtration System manuals by other brands

POOL LAB
POOL LAB PL Series owner's manual

Plasma Made
Plasma Made GUC 1214 Installation and user manual

BIOLUX
BIOLUX EOS-7130 owner's manual

Vacman
Vacman Hydrofilter Robot Platinum user manual

HARMSCO
HARMSCO BC6-1 Installation and operation

FreshWater
FreshWater MP1K Installation Guide and Technical Information

Micromax
Micromax 6500 TFC owner's manual

HYDAC FILTER SYSTEMS
HYDAC FILTER SYSTEMS FCC Operating and maintenance instructions

Franklin Electric
Franklin Electric SUBDRIVE UTILITY installation guide

Savio
Savio Water Master Pump Series Operating Manual & Specifications

HQUA
HQUA PAS20 instruction manual

Franke
Franke F1 user guide