How to access the unit’s web interface
The unit does not have a DHCP server and will not provide any IP address to your PC when you
connect the Ethernet cable. To be able to access the unit, your PC needs to be configured with a
static IP address that is within the same subnet as the IP address of the unit.
To change the IP address of your network card you need to open the configuration utility for your
network card. For information on how to do that please consult you operating system manual.
The default IP settings of the units are:
IP
Netmask
Master unit
10.0.0.1
255.0.0.0
Client unit
10.0.0.2
255.0.0.0
Recommended configuration of your network card is:
IP
Netmask
10.0.0.3
255.0.0.0
You do not need to have a gateway address to configure the unit when you are connected directly
to it.
If you want the units to be accessible within your normal subnet you will have to reconfigure the
IP addresses of the units. Remember that after changing the IP address of the unit you will not be
able to access it again until you have reconfigured your network card to be in the same subnet as
you configured in the unit.
Note Your Trinity link will work as a cable replacement (transparent bridge), therefore you should
never connect both units to the same switch or Ethernet segment. Doing so will cause an infinite
forwarding loop which severely will disrupt normal traffic on your network.
Warning: At all times, it is the customer’s responsibility to ensure that an outdoor antenna
installation complies with local radio, electric and safety regulations.
If you are not certain about the regulations that apply in your country, consult your regulatory
agency or a local Sub10Systems-Repeatit sales partner.
The customer must verify that:
The installation is performed by a qualified technician.
The antenna installer is aware of local regulations and limits, including, but not limited to,
allowed frequency spectrum and maximum EIRP limits.
The final installation complies with local radio, electric and safety regulations, including, but
not limited to allowed frequency and maximum EIRP limit.
Repeatit AB and its resellers or distributors are not liable for any damage or violation of
government regulations that may arise from failing to comply with these guidelines.
Repeatit AB
Tel: +46 8 570 106 66
Hamngatan 33
Fax: +46 8 570 106 67
172 66 Sundbyberg