General Product Information
Product description
e VPRC/VPRH 09–36 single package vertical air conditioner
(SPVAC) and heat pump (SPVHP) creates new options in layout and
space utilization. e VPRC/VPRH 09–36 oers low cost operation
and quiet, comfortable air distribution, especially when used in multi-
room suites, apartments, health care facilities, and homes.
Each system utilizes environmentally-friendly R-410A refrigerant,
and is supplied with a custom wall sleeve and outdoor louver. e
cabinet is constructed with 20 gauge galvanized steel with a G-90U
corrosion-resistant rating. e insulated top-discharge indoor com-
partment provides quiet, ducted, conditioned air delivery to other
room location(s).
Framed into a concealed closet enclosure for low operating sound
levels, the VPRC/VPRH vertical discharge allows ducting to the top
of the room(s) for superior air circulation and distribution.
All VPRC/VPRH models can be applied in non-ducted return air
applications. e VPRC/VPRH 30-36 can also be applied in ducted
return air applications.
e VPRC/VPRH oers an economic benet when used in a multi-
room suite by supplying conditioned air to more than one room with-
out the need to install additional units. is is also a design advantage
since other rooms will not need an exterior wall to accommodate
additional units.
VPRH models are limited-range heat pumps heat pump operation
will cease at approximately 40°F (4.4°C) outdoor temperature. Utiliz-
ing the electric resistant heat option or the hydronic heat option is rec-
ommended if the heating load of the application will require the unit
to operate in outdoor ambient temperatures below 40°F (4.4°C).
Standard controls and components:
Cooling or heat pump chassis with high eciency rotary, scroll•
or reciprocating type compressors
Custom wall sleeve•
Anodized aluminum outdoor louver for indoor eld installation•
(optional colors available)
R-410A refrigerant•
Ability to utilize single or 2-stage thermostat for VPRH emer-•
gency heat
Front-mounted control box standard for 09–36 (right or le-side•
mounting available for 09–24 only)
Manual fresh air damper for models 09–24 motorized fresh air•
damper for models 30–36
Filter disposable return air lter for models 09–24 only, and a•
washable, reusable return air lter for models 30–36 only
ermostatic drain pan valve for heat pump operation condensate•
removal (VPRH 09, 12, 19–24 only)
Air systems
•
Motors are thermally protected PSC type. Air stream surfaces–
are insulated with 1/4inch (6.3 mm) berglass or 1/8inch
(3.2 mm) VolaraTM.
e indoor fan is a forward-curved type directly mounted to–
the motor sha.
Models VPRC/VPRH 09, 12, 19 & 24 blow air across the–
outdoor coil, while models VPRC/VPRH 18, 30 & 36 draw
air through the outdoor coil.
Condensate removal
•
VPRC/VPRH 09, 12, 19 & 24 e outdoor blower incor-–
porates a condensate slinger ring. Base pans are designed to
accommodate a eld-installed drain stub kit if necessary. See
eld installed accessories.
VPRC/VPRH 18, 30 & 36 require an internal drain system.–
Models VPRC/VPRH 18 are supplied standard with an over-
ow drain stub kit for eld installation.
VPRC/VPRH– 30-36 outdoor coil side drain stub is integral to
the base pan, and allows easy connection of the drain line.
Microprocessor control board
•
Universal control board is used in straight cool electric resis-–
tance heat, hydronic heat (models 09–24 only), or cooling/
heat pump applications
Random start timer prevents multiple units from simultane-–
ous start-ups
Fan purge fan remains on for 60 seconds aer heat/cool–
call is satised
Anti-short-cycle compressor protectionprevents the compres-–
sor from rapid cycling
Freeze protection prevents evaporator coil freeze up,–
improving compressor reliability
Low ambient lockout prevents compressor operation in out-–
door temperatures less than 40°F (4.4°C)
Test operation all timers are temporarily suppressed to–
allow ease of testing or troubleshooting
Control board LED provides self-diagnostic troubleshooting–
codes (see Sequence of Operation, page 26)
Factory-installed options:
Supplemental electric heat see heat options in Figure 1•
265/277V (contact factory for availability)•
Corrosion-resistant coil options (sea coast and harsh environ-•
ment usage):
Coated aluminum n/copper tube condenser coil–
Models 09–18 only 10-inch diameter (254 mm) factory-•
installed duct collar
Models 09–12 only Carrier Model 50QT/ET replacement•
conguration
Models 09–24 only Right or le control box mounting•
Models 09–24 only Hydronic heat option•
Models 09–24 only Power disconnect switch ONLY to a•
maximum of 5kW electric heat, or hydronic heat
Field-installed accessories:
Hydronic heat plenum (coil included on models 09–24 only)•
Remote wall thermostat (digital 1-stage or 2-stage available)•
Painted condenser louver (baked enamel/Kynar)•
Returnairaccesspanel(standardwhite,consultfactory forcustom•
colors w/disposable return air lters) optional solid panel
available for application with separate air intake
Models 09, 12, 19–24 only Drain stub kit can be installed•
on front, right side or le side.
Wall sleeve transition kit Model 30 only - Needed when installing•
a VPRC/VPRH 30 in place of a VPAC/VPHP 30. (See Pg. 15)