RXIH-AB12A AND RXIH-AB17A BY-PASS FLOW-THROUGH HUMIDIFIERS
69-2297—01 2
IMPORTANT
Please read these instructions and keep them in your records.
OPERATING YOUR HUMIDIFIER
Humidifiers are controlled by the Convertible
Humidity Control. The convertible humidity control is
installed either on an interior wall in the living area,
or on the return air duct. Choose the humidity
control setting using the combination relative
humidity/outdoor temperature setting scale on your
humidity control dial. Match the dial setting to the
outdoor temperature for optimizing the humidity
level while reducing moisture condensation on your
windows. The table below can also be used to
adjust humidity control to the recommended setting.
NOTE: As outside temperature drops, the recommended humidity control setting is
lowered to adjust for effects of dewpoint. These settings should reduce accu-
mulation of moisture and ice on your windows and other areas of your home.
Some indoor activities such as cooking, showering and clothes drying can cause
excessive levels of humidity and start the accumulation of moisture on your windows.
NOTE: If this condition persists for more than a few hours, set the humidity control to
the lowest setting to turn off the humidifier. If the condition does not improve,
ventilate your home to remove the moisture.
HOW YOUR HUMIDIFIER WORKS
Your humidifier uses the principle that vapor (evaporated water) is created when warm
air blows over a water soaked area. As the vapor circulates, the relative humidity rises.
Your humidity control monitors the relative humidity and activates the humidifier
accordingly. The humidifier has a water supply that dispenses water evenly over the
antimicrobial humidifier pad. The warm dry air, from the furnace, passes over the
humidifier pad and picks up the moist air to circulate it throughout your home.
At Outside
Temperature
Recommended
Control Setting
At Outside
Temperature
Recommended
Control Setting
-20°F (-29°C) 15 +10°F (-12°C) 30
-10°F (-23°C) 20 +20°F (-7°C) 35
0°F (-18°C) 25 Above 20°F (-7°C) 40
M29011
69-2297_A.fm Page 2 Thursday, December 11, 2008 11:54 AM

RXIH-AB12A AND RXIH-AB17A BY-PASS FLOW-THROUGH HUMIDIFIERS
3 69-2297—01
Humidified air feels warmer and more comfortable so you may be able to lower your
thermostat heating setpoint, which saves money on your heating fuel bills. The end
result is that your humidifier gives you a cleaner, more comfortable environment that is
also energy efficient.
MAINTAINING YOUR HUMIDIFIER
A regular maintenance program prolongs the life of your humidifier and provides a
more comfortable home. Frequency of cleaning depends on the condition of your
water. You can use either hard or soft water in your humidifier, but hard water mineral
deposits are more difficult to clean than soft water deposits. For optimum performance,
replace the antimicrobial pad once a year. Use the following procedure to clean your
humidifier.
WARNING
Serious Personal Injury Hazard.
Can cause electrical shock and injury from moving parts.
Disconnect power and shut off water supply before removing cover.
IMPORTANT:
Never oil any part of
the humidifier.
Every 1 to 3 Months
(Depending on Water
Quality)
1. Disconnect power and
turn off humidifier water
supply.
2. Remove the humidifier
cover by unplugging the
connector and loosening
the thumb screw. Grasp
the cover near the bottom
and pull toward you.
3. Remove humidifier pad
assembly from humidifier
by grasping top of tray
and pulling it toward you.
4. Lift the tray off the pad.
5. Gently pinch water nozzle
catches inward until you
can lift water nozzle off
tray.
M29012
WATER
DISTRIBUTION TRAY
WATER FEED NOZZLE
HUMIDIFIER HOUSING
SIDEWALL
BYPASS SIDEWALL
COVER
WATER FEED TUBE
A
NTIMICROBIAL
HUMIDIFIER PAD ASSEMBLY
69-2297_A.fm Page 3 Thursday, December 11, 2008 11:54 AM

RXIH-AB12A AND RXIH-AB17A BY-PASS FLOW-THROUGH HUMIDIFIERS
69-2297—01 4
6. Carefully remove any mineral deposits from tray and frame. Be sure frame drain
hole is not blocked.
7. Disconnect drain hose from drain fitting on the bottom of the humidifier housing.
8. Clean the drain fitting, if necessary.
9. Bend the drain hose to loosen any mineral deposits.
10. Flush the drain hose with pressurized water (a running tap) to clean the hose.
11. Reattach the drain hose to the drain fitting.
12. Snap the water nozzle back on the tray.763-954-4569
13. Be sure the marked end of the pad is facing up. Place the tray on the new pad.
14. Place humidifier pad assembly in humidifier housing. Be sure water feed tube is
placed in guide slots.
15. Replace the humidifier cover.
16. See “checking your humidifier operation” on page 4. to verify operation.
End of Humidification Season
Clean the humidifier and shut it off at the end of the heating season. See “Every 1 to
3 Months” section, steps 1 through 15, to shut down for the season.
IMPORTANT:
Be sure humidifier power is off.
VACATION
The humidifier water supply and your humidity control can be turned off. Turn on
humidifier water supply and reset your humidity control when you return.
CHECKING YOUR HUMIDIFIER OPERATION
After winter startup or servicing, check the humidifier operation:
1. Turn on the humidifier power and water supply.
2. Turn the Convertible Humidity Control to highest setting; set thermostat to 10°F
(6°C) above room temperature.
3. Observe that water is flowing out of the drain hose.
NOTE: The furnace blower must be on to activate the humidifier.
4. Reset thermostat and Control to comfortable setting.
69-2297_A.fm Page 4 Thursday, December 11, 2008 11:54 AM

RXIH-AB12A AND RXIH-AB17A BY-PASS FLOW-THROUGH HUMIDIFIERS
5 69-2297—01
TROUBLESHOOTING YOUR HUMIDIFIER
Problem What to Look for What to Do
Low
humidity
Furnace blower not
operating.
•Reset circuit breaker or replace fuse.
•Check that the furnace power is on.
•Check all external wiring connections.
•Check humidity control setting.
•Call a heating contractor.
Rapid air changes.
Drafts (cold air is dry
and is an added load
to humidifier).
•Keep doors and windows closed.
•Close fireplace damper if not using.
•Minimize exhaust fan running time.
•Seal around doors and windows.
High
humidity
Condensation on
walls.
•Turn off humidity control and water until
condensation is completely evaporated.
Heavy condensation
on windows.
•Turn humidity control low enough to eliminate
bath and cooking condensation moisture. If
moisture persists, more ventilation is needed.
69-2297_A.fm Page 5 Thursday, December 11, 2008 11:54 AM

RXIH-AB12A AND RXIH-AB17A BY-PASS FLOW-THROUGH HUMIDIFIERS
69-2297—01 6
LIMITED FIVE-YEAR WARRANTY
5 years from date of purchase (contact the Rheem Parts Distribution
Center for more information).
69-2297_A.fm Page 6 Thursday, December 11, 2008 11:54 AM

RXIH-AB12A AND RXIH-AB17A BY-PASS FLOW-THROUGH HUMIDIFIERS
7 69-2297—01
69-2297_A.fm Page 7 Thursday, December 11, 2008 11:54 AM

RXIH-AB12A AND RXIH-AB17A BY-PASS FLOW-THROUGH HUMIDIFIERS
® U.S. Registered Trademark
© 2008
69-2297—01 M.S. 12-08
Before proceeding with installation, refer
to installation instructions packaged with
each model, as well as complying with
all Federal, State, Provincial, and Local
codes, regulations, and practices.
RHEEM
AIR CONDITIONING
DIVISION
5600 Old Greenwood Road, Fort Smith, Arkansas 72908
“In keeping with its policy of continuous progress and product improvements, Rheem reserves the right to make changes without notice.”
69-2297_A.fm Page 8 Thursday, December 11, 2008 11:54 AM