4. Interface
Color
Red +12VDC
Black GND
Green R+
White R-
Description
Yellow External LED control(Internal 2K pulled-up)
Brown Reserved
Blue Reserved
Grey Reserved
5. Trouble Shooting
When powered up, the Rhombus105 take a self-test to ensure the best reading performance with the buzzer beeping continually.When the
self-test ends, the buzzer will give out a long beep and the Rhombus105 enter the normal working mode. If the buzzer continue beeping without
stop for a long time, please turn off the power and check out the enviroment and power supply to ensure locating the Rhombus105 in a good
working condition. In case of problems the following procedure should be followed:
Failure to finish self-test with the buzzer beeping continually or with a short reading distance
1) Turn off the power to the Rhombus105;
2) Check the power input connections making sure that they are not reversed;
3) Check the power supply complying with the specification;
4) If the supply has a current limit, set this to 350mA;
5) Make sure to install the Rhombus105 in a environment without large area conductors nearby or mounting on a conductive surface. In self-test
state, do not apply any tags in Rhombus105’s functional area;
6) Try to change the installment of the Rhombus105 to another place to check if the trouble still exists;
Note: Rhombus’products must work with linear regulated power supply, and other kinds of power supply are prohibited.