RIGTEC CWC01 User manual

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
SWIVEL COUPLERS
(CWC01)
USER GUIDE
Version 1.0

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
Thank you for purchasing a Rigtec Swivel Couplers.
We hope you enjoy using the Swivel Couplers as much as
we’ve enjoyed designing and manufacturing them.
If you have any questions, suggestions or just want to say hello;
please contact the team at [email protected]

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
CONTENTS
SAFETY INFORMATION 3
SWIVEL COUPLER PARTS 5
SWIVEL COUPLER SAFETY INFORMATION 6
AIR FRAME X10 APPROVED RIGGING LOCATIONS 7
AIR FRAME X20 APPROVED RIGGING LOCATIONS 8
AIR FRAME X25 APPROVED RIGGING LOCATIONS 9
AIR FRAME X30 APPROVED RIGGING LOCATIONS 10
AIR FRAME X40 APPROVED RIGGING LOCATIONS 11
AIR FRAME X50 APPROVED RIGGING LOCATIONS 12
ATTACHING TO AIR FRAME:
LANDSCAPE 13
PORTRAIT 14
FLOOR PROJECTION 15
SAFETY STEEL CABLES 16
SPECIFICATION 17
CE DECLARATION OF CONFORMITY 18
UKCA DECLARATION OF CONFORMITY 19

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
3
SAFETY INFORMATION
These instructions should be handed over to the
person carrying out the installation.
• Only a qualied, trained and competent technician should carry out
installation work.
• The device should only be used with approved accessories and spares.
• Do not exceed the Working Load Limit (WWL) – when used with other
accessories make sure that the Working Load Limit of any component is
not exceeded.
• Care should be taken when lifting and moving – the combined weight of
the device and any accessory should be within safe manual handling limits.
• Care should be taken when transporting that injury is not caused - make
sure the device and any attached accessory is correctly secured.
• All equipment should be visually inspected before use and in the event of
any damage, it must be immediately taken out of service and assessed by a
competent person.
• Any suspended accessory must be independently secured with an
approved safety wire/s. Local laws or regulations should be consulted
regarding the additional safety of hanging equipment
• When working at elevated heights or under a suspended load, make sure
that all necessary precautions have been taken.
• Only install the approved projectors into the Air Frame, as listed in the User
Guide. Attempting to install projectors other than those listed in the User
Guide may result in serious injury.
• Do not use the Air Frame outdoors. The Air Frame should not be installed
where it can be exposed to wind or rain.
• Do not expose the Air Frame to moisture or excessive heat.
• Do not install the Air Frame on unstable surfaces.
• Do not hang the Air Frame from unstable, unsafe or inappropriate objects/
structures. Ensure the structure can support the overall weight.
• When stacking Air Frames, ENSURE all four locking pins are securely
positioned through the adjoining male and female Air Frame stacking
connectors.

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
4
SAFETY INFORMATION
These instructions should be handed over to the
person carrying out the installation.
• Do not install an Air Frame whilst people are under the hanging area.
• Do not make adjustments to a hanging Air Frame or Atom Grip whilst
people are under the hanging area.
• A Minimum of TWO people should be used to lift, carry and install the Air
Frame with a projector installed.
• Thorough examination of lifting equipment must take place at least every
12 months by a qualied technician.
In addition to these scheduled examinations, equipment will require a thorough
examination following:
• Any accident or dangerous occurrence.
• Any signicant change in conditions of use.
• Any long periods of inaction.
• Each time the equipment is used.

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
5
PART NAMES
Use this page as a reference of the various part names throughout
this User Guide.
1. Quick Trigger Clamps
2. Quick Trigger Clamp Handle
3. 32mm Clamp
4. 32mm Clamp Thumb Screw

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
6
SWIVEL COUPLER
SAFETY INFORMATION
Before attaching the Swivel Couplers to the Air Frame please read the
following safety information:
1. Swivel Couplers MUST ONLY be attached to the Air Frame in
the APPROVED LOCATIONS (See pages 7-12 for details on the
approved locations)
2. DO NOT attach Swivel Couplers to any other part of the frame
other than those highlighted in Images 1, 2 and 3.
3. The approved locations should only be used for the correct
orientation. Please be aware, not all approved locations can be
used in all orientations – DO NOT use the oor projection
approved locations for landscape projection.
4. Please note, Swivel Couplers MUST NOT be attached to the
front removable bar.
5. Always use FOUR Swivel Couplers to suspend the Air Frame.
6. Any suspended accessory must be independently secured with
an approved SAFETY WIRE/S. Local laws or regulations should
be consulted regarding the additional safety of hanging
equipment.
7. Only stack a MAXIMUM of THREE Air Frames (AF02-X10), when
suspending with Swivel Couplers.
8. If you wish to use Rigtec Swivel Couplers with a third party
frame, please consult the third party frame user guide or
contact the manufacturer for important safety information
such as the approved hanging locations.

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
7
AIR FRAME X10
APPROVED RIGGING
LOCATIONS
These diagrams show the approved locations where the Swivel
Couplers can be mounted to the Air Frame X10.
Swivel Couplers MUST ONLY be attached to the Air Frame in the
APPROVED LOCATIONS
DO NOT attach Swivel Couplers to any other part of the frame other
than those highlighted in Images 1, 2 and 3.
The approved locations should only be used for the correct
orientation. Please be aware, not all approved locations can be used
in all orientations – DO NOT use the oor projection approved
locations for landscape projection.
Please note, Swivel Couplers MUST NOT be attached to the front
removable bar.
1. Landscape Projection
2. Portrait Projection 3. Floor Projection
Back
Top Bottom
Right
Left

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
8
AIR FRAME X20
APPROVED RIGGING
LOCATIONS
These diagrams show the approved locations where the Swivel
Couplers can be mounted to the Air Frame X20.
Swivel Couplers MUST ONLY be attached to the Air Frame in the
APPROVED LOCATIONS
DO NOT attach Swivel Couplers to any other part of the frame other
than those highlighted in Images 1, 2 and 3.
The approved locations should only be used for the correct
orientation. Please be aware, not all approved locations can be used
in all orientations – DO NOT use the oor projection approved
locations for landscape projection.
Please note, Swivel Couplers MUST NOT be attached to the front
removable bar.
1. Landscape Projection
2. Portrait Projection 3. Floor Projection
Back
Top Bottom
Right
Left

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
9
AIR FRAME X25
APPROVED RIGGING
LOCATIONS
These diagrams show the approved locations where the Swivel
Couplers can be mounted to the Air Frame X25.
Swivel Couplers MUST ONLY be attached to the Air Frame in the
APPROVED LOCATIONS
DO NOT attach Swivel Couplers to any other part of the frame other
than those highlighted in Images 1, 2 and 3.
The approved locations should only be used for the correct
orientation. Please be aware, not all approved locations can be used
in all orientations – DO NOT use the oor projection approved
locations for landscape projection.
Please note, Swivel Couplers MUST NOT be attached to the front
removable bar.
1. Landscape Projection
2. Portrait Projection 3. Floor Projection
Back
Top Bottom
Right
Left

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
10
AIR FRAME X30
APPROVED RIGGING
LOCATIONS
These diagrams show the approved locations where the Swivel
Couplers can be mounted to the Air Frame X30.
Swivel Couplers MUST ONLY be attached to the Air Frame in the
APPROVED LOCATIONS
DO NOT attach Swivel Couplers to any other part of the frame other
than those highlighted in Images 1, 2 and 3.
The approved locations should only be used for the correct
orientation. Please be aware, not all approved locations can be used
in all orientations – DO NOT use the oor projection approved
locations for landscape projection.
Please note, Swivel Couplers MUST NOT be attached to the front
removable bar.
1. Landscape Projection
2. Portrait Projection 3. Floor Projection
Back
Top Bottom
Right
Left

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
11
AIR FRAME X40
APPROVED RIGGING
LOCATIONS
These diagrams show the approved locations where the Swivel
Couplers can be mounted to the Air Frame X40.
Swivel Couplers MUST ONLY be attached to the Air Frame in the
APPROVED LOCATIONS
DO NOT attach Swivel Couplers to any other part of the frame other
than those highlighted in Images 1, 2 and 3.
The approved locations should only be used for the correct
orientation. Please be aware, not all approved locations can be used
in all orientations – DO NOT use the oor projection approved
locations for landscape projection.
Please note, Swivel Couplers MUST NOT be attached to the front
removable bar.
1. Landscape Projection
2. Portrait Projection 3. Floor Projection
Back
Top Bottom
Right
Left

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
12
AIR FRAME X50
APPROVED RIGGING
LOCATIONS
These diagrams show the approved locations where the Swivel
Couplers can be mounted to the Air Frame X50.
Swivel Couplers MUST ONLY be attached to the Air Frame in the
APPROVED LOCATIONS
DO NOT attach Swivel Couplers to any other part of the frame other
than those highlighted in Images 1, 2 and 3.
The approved locations should only be used for the correct
orientation. Please be aware, not all approved locations can be used
in all orientations – DO NOT use the oor projection approved
locations for landscape projection.
Please note, Swivel Couplers MUST NOT be attached to the front
removable bar.
1. Landscape Projection
2. Portrait Projection 3. Floor Projection
Back
Top Bottom
Right
Left

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
13
ATTACHING RIGTEC
SWIVEL COUPLERS
To hang an Air Frame in Landscape Orientation with the Rigtec
Swivel Couplers, follow these instructions:
1. Measure the distance between the two truss chords that will be
used to hang the Air Frame.
2. Using the 32mm clamps, attach two Swivel Couplers at the
measured distance apart on the upper side bar. Repeat this on
the other upper side bar so all FOUR Swivel Couplers are attached.
3. Ensure the 32mm clamps are tight by tightening the 32mm
Clamp Thumb Screws and hang the Quick Trigger Clamps from
the Truss.
4. Ensure all four Quick Trigger Clamps are tightened to grip the
Truss chords by tightening the Quick Trigger Clamp Handles.
Always use FOUR Swivel Couplers to suspend the Air Frame
Any suspended accessory must be independently secured with an
approved safety wire/s. Local laws or regulations should be consulted
regarding the additional safety of hanging equipment
1
3
2
4

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
14
ATTACHING RIGTEC
SWIVEL COUPLERS
To hang an Air Frame in Portrait Orientation with the Rigtec Swivel
Couplers, follow these instructions:
1. Measure the distance between the two truss chords that will be
used to hang the Air Frame.
2. Using the 32mm clamps, attach two Swivel Couplers at the
measured distance apart on the upper side bar. Repeat this on
the lower side bar so all FOUR Swivel Couplers are attached on
the same side of the Air Frame.
3. Ensure the 32mm clamps are tight by tightening the 32mm
Clamp Thumb Screws and hang the Quick Trigger Clamps from
the Truss.
4. Ensure all four Quick Trigger Clamps are tightened to grip the
Truss chords by tightening the Quick Trigger Clamp Handles.
Always use FOUR Swivel Couplers to suspend the Air Frame
The Removable Front Bar MUST be in place and secured when
the Air Frame is hanging in a portrait orientation.
Any suspended accessory must be independently secured with an
approved safety wire/s. Local laws or regulations should be consulted
regarding the additional safety of hanging equipment
1
3
2
4

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
15
ATTACHING RIGTEC
SWIVEL COUPLERS
To hang an Air Frame in Floor Projection Orientation with the Rigtec
Swivel Couplers, follow these instructions:
1. Measure the distance between the two truss chords that will be
used to hang the Air Frame.
2. Using the 32mm clamps, attach two Swivel Couplers at the
measured distance apart to the upper back bar. Repeat this on
the lower back bar so all FOUR Swivel Couplers are attached.
3. Ensure the 32mm clamps are tight by tightening the 32mm
Clamp Thumb Screws and hang the Quick Trigger Clamps from
the Truss.
4. Ensure all four Quick Trigger Clamps are tightened to grip the
Truss chords by tightening the Quick Trigger Clamp Handles.
Always use FOUR Swivel Couplers to suspend the Air Frame
Any suspended accessory must be independently secured with an
approved safety wire/s. Local laws or regulations should be consulted
regarding the additional safety of hanging equipment
1
3
2
4

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
16
SAFETY
STEEL CABLES
The installer bears the responsibility to ensure the Air Frame is
suspended in a safe and secure fashion. Safety Steel Cables must
be applied to suspended Air Frames according to local regulations
and standards. For more information on safely suspending
equipment please consult local laws and regulations.
The installer must ensure safety cables are the correct length,
format and strength - No drop distance is allowed or must be
limited as much as possible.
Please follow these instructions and diagrams when choosing
where to position Safety Steel Cables on Rigtec Air Frames:
1. Landscape Orientation; Please loop safety steel cables around
the suspending truss and through the Air Frame, around the
Side Bars.
2. Portrait Orientation; Please loop safety steel cables around the
suspending truss and through the Air Frame, around the Side
Bars.
3. Floor Projection Orientation; Please loop safety steel cables
around the suspending truss and through the Air Frame,
around the Back Bars.
DO NOT USE THE REMOVABLE FRONT BAR FOR ATTACHING A
SAFETY STEEL CABLE

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
17
SPECIFICATION
Part Number: CWC01
Description: Swivel Coupler
Weight: 0.6kg / 1.32 lbs
WLL: 100kg / 220.46 lbs (Per Swivel Coupler)

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
18
CE DECLARATION
OF CONFORMITY
Manufacturer:
Rigtec Ltd
Unit B1 Holly Farm Business Park
Kenilworth
CV8 1NP
+44 (0) 1926 290 418
www.rigtec.com
Description of lifting accessory: Swivel Couplers
Part Number: CWC01
Is in accordance with the following Directive:
Machinery Directive 2006/42/EC
Harmonised Standards:
EN ISO 12100:2010
Safety of machinery. General principles for design. Risk assessment and risk
reduction
I hereby declare that the equipment named above has been designed to comply
with the relevant sections of the above referenced specications. The unit
complies with all applicable essential requirements of the EC directives.
Signed:
Matthew Boyse - Authorised Representative
Rigtec Ltd
18/05/2021
Registered Address: Unit B1 Holly Farm Business Park, Honiley, Kenilworth,
Warwickshire, CV8 1NP
Registration Number: 08702138

T I +44 (0)1926 290 418 E I hello@rigtec.com W I www.rigtec.com
19
UKCA DECLARATION
OF CONFORMITY
Manufacturer:
Rigtec Ltd
Unit B1 Holly Farm Business Park
Kenilworth
CV8 1NP
+44 (0) 1926 290 418
www.rigtec.com
Description of lifting accessory: Swivel Couplers
Part Number: CWC01
Is in accordance with the following Directive:
Supply of Machinery [Safety] Regulations 2008 and Supply of Machinery [Safety]
Regulations [A] 2011
Harmonised Standards:
EN ISO 12100:2010
Safety of machinery. General principles for design. Risk assessment and risk
reduction
I hereby declare that the equipment named above has been designed to comply
with the relevant sections of the above referenced specications. The unit
complies with all applicable essential requirements of the UKCA directives.
Signed:
Matthew Boyse - Authorised Representative
Rigtec Ltd
18/05/2021
Registered Address: Unit B1 Holly Farm Business Park, Honiley, Kenilworth,
Warwickshire, CV8 1NP
Registration Number: 08702138
Table of contents
Other RIGTEC Rack & Stand manuals
Popular Rack & Stand manuals by other brands

Konig & Meyer
Konig & Meyer 15045 manual

Wheelock
Wheelock E50-241575W installation instructions

QSC
QSC TSC-50t-G3 quick start guide

Penn Elcom
Penn Elcom Rackz Limited Credenza Wood Rack Series Assembly instructions

iOttie
iOttie Easy One Touch 5 manual

PEERLESS
PEERLESS Paramount PSP2 Installation and assembly