Processor
Intel® Atom™ E3805 dual core
Speed / Cache
1.33 GHz / 1 MB
I/O
1 x 10/100 Fast Ethernet (RJ-45) with PoE (15.4W)
Serial Interfaces: 2 x RS-232/422/485.
GPIO Multi-function I/O: 0-5V, 8 channel, independently programmable, DAC, ADC. Optional ZigBee module.
I/O (All models)
USB: 1x USB 2.0, 1x USB 3.0
Integrated MEMS: Accelerometer, Pressure, Temperature and Humidity
Integrated GPS
Wireless LAN: 2.4GHz, 802.11b/g/n/Bluetooth Low Energy 4.0
Optional zigbee on 3001
WWAN/Cellular: 3G or 4G LTE for select countries, US/Canada 4G LTE with AT&T or Verizon
(WWAN card is factory installed only)
Antenna ports for: Wi-Fi/BLE/GPS, 3G or 4G
Dimensions
125 mm wide x 125 mm high x 51 mm deep (4.9 x 4.9 x 2 inches)
Weight
1 kg +/- 0.02 kg (2.2lbs +/- 0.04lbs)
Form Factor
Fanless and headless. Mounting optimized for 75x75mm VESA, wall (standard) mounting and DINrail
mounting. Additional mounting options include perpendicular DIN-rail mount, quick- release DINrail mount,
and cable management control bars for standard mounting.
Environmentals
Ruggedized (shock and vibration resistant) for challenging environments. IP50 rating.
Operating Temperature2: -30C (-22F) to 70C (158F)* - true still air environment, no forced air or
airow required inside a sealed enclosure).
Storage Temperature: -40C (0% RH) to 70C (20% RH)
Relative Humidity: Operating: 10% to 95% (non-condensing)
Storage/Drives
Industrial-grade Micro-SD card: 8GB / 16GB / 32 GB / 64 GB. Embedded multi-media controller
(eMMC): 8GB standard / 32GB option with WWAN.
Memory
2 GB, DDR3L – 1066 MHz
Operating Framework
Ubuntu Core 16 with Riptide Hub software
Riptide Hub
On site gateway device for connecting to VRF Gateway and
other integrated devices
Compatible with the following Daikin VRV Models
FXAQ, FXDQ, FXEQ, FXFQ, FXHQ, FXLQ, FXMQ, FXMQ_MF, FXNQ, FXTQ, FXUQ, FXZQ, VAM, VRV4S1, VRV4S2, VRV-3S, VRV-3P,
VRV4S3, VRVX, VRV4-EU, VRV-3R, VRV3C, VRV-4R, VRV-M
System Hardware Components
Riptide Edge
Universal VRF Gateway
Translator of DIII-Net protocol connected to Daikin VRV via
F1F2 Out
Notes
1. Ambient temperature specication is based on free air environment and recommended mounting
2. 2.5inches (63.5mm) open space around the device is recommended for air circulation
3. Actual maximum operating temperature depends on variables including airow, mounting, and orientation
4. Temperature measured at the center of exposed heatsink base surface shall not exceed 83C

©2018 Riptide - Put Your Facilities on Autopilot. All rights reserved. riptideio.com
I/O
Interfaces via RS232 (ASCII), RS485 (MODBUS RTU), Ethernet (ASCII & MODBUS IP)
Dimensions
156 mm wide x 90 mm high x 34 mm deep (6.1 x 3.5 x 1.3 inches)
Weight
1 kg +/- 0.02 kg (2.2lbs +/- 0.04lbs)
Form Factor
Fanless. Mounting optimized for wall (standard) mounting and DIN-rail mounting
Power Input
AC Power supply adapter included. 12V DC out; 100V-240V AC 50/60hz in
Option for direct DC power supply. 12V-24V DC
Universal VRF Gateway
Wiring Diagram
Continuous Monitoring and Control
Indoor & Outdoor Units: Change set points, get diagnostic
data, monitor and control indoor and outdoor units.
Building Integration: Bring together other systems and
buildings in a single interface; supports BACnet, Modbus
and many proprietary protocols.
Features/Benets
Field Alerts & Notications
Get Alerts: We monitor more than 80 system data points
and alert when any alarm conditions are detected.
Get Notied: If an alert condition is detected, an authorized
service tech can be notied via text or email for quick
maintenance response to reduce any potential downtime.

Riptide and Daikin VRV – iTouchManager Addressing
The Riptide system communicates with the Daikin VRV and other manufacturers’ equipment to allow for remote management via
web and mobile. In order for the Riptide system to communicate with the Daikin VRV iTouchManager, the system requires the
following addressing:
iTM needs to be addressed as follows:
IP address: 192.168.1.102
Subnet: 255.255.255.0
Gateway: 192.168.1.1

PROJECT ADDRES
PROJECT CITY, STATE
SCALE
REVISIONS
NO. DATE DESCRIPTION
FILE NAMEDRAWN
TITLE
DATE CREATED
315 Meigs Road, #A110
Santa Barbara, CA 93109
Phone (805) 965-3659
Fax (775) 368-4273
0
Background-1
Riptide
08/04/16
N/A
Anywhere usa
Anywhere, usa
Riptide Base Kit
Riptide AirReps OED PanelShawn Leimbrock
16
of
Duplex
Outlet
5 Port Ethernet Switch
TL-SG105
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
Dell Edge Gateway 3001
2.5A DC
Power
Supply
MDR-60-24
16 x 16 Perf Panel
L1
+
-
F1F2
L2
IOIOI1
IOIOI2 +
-
F1F2
F1F2
F1F2
For cellular deployments mount Cradlepoint Modem external
of enclosure and connect to switch port
Daikin DIII F1F2
BACnet MS/TP
Modbus/Other
Daisy chain from iTM to Riptide terminal block
See iTM Installation Manual section 2.2.2 for cable requirements
iTM Connections and Conceptual Diagram
iTM Rear Face
DIII Communication Line

Cradlepoint COR IBR200 Quick Start
Purpose of Cradlepoint Cellular Router
Lbrands has approved installation of the Cradlepoint cellular router to provide
remote, internet-based access to the Trane SC Controller. The device will give
remote technicians secure access to the controller via a Netcloud Perimeter VPN
and authorized log on credentials.
What’s Included
Mounting and powering
1. The device has been shipped pre-configured, with SIM already installed. Do
not remove SIM. Reseat SIM only if it is no longer in its slot.
2. Connect modem antennas (finger tight only). Do not connect WiFi antennas
as this device will be used for wired connection only (see device image
below).
1

FOR TECHNICIAN - Download and install NetCloud
Client software
NetCloud Perimeter is a secure, invitation-only software download deployed that
will connect the user to the Cradlepoint router for remote, internet based access.
Technicians who will connect to equipment (e.g. Trane SC controller) remotely will
need to download and install the software as follows:
1. From a browser, navigate to here: https://cradlepoint.com/downloads
2. Choose your download based on your device type (Windows, Mac, iOS,
Android, etc.)
3. Follow instructions on screen to install the software.
4. Log on using credentials provided by Riptide. You're done!
www.riptideio.com
Phone: (805) 318-3215
Table of contents