Risen SYP-85S User manual

NINGHAI RISENELECTRIC CO., LTD.
GeneralInstallationManualforRISENPhotovoltaicModules.
Pleasereadthismanualcompletelybeforeinstallingorusingthemodules.
Thismanualisappliedforthefollowing products:
SYP-85S, SYP-110S, SYP-160S, SYP-165S, SYP-170S, SYP-175S,SYP-180S, SYP-200S, SYP-210S
INTRODUCTION
Thankyou forchoosingRISENPVmodules.Withproperoperationand maintenance,RISENPVmoduleswill
provideyouwithclean, renewablesolarelectricityformanyyears.
Keepthismanualforreference. Thismanualcontainsimportantinformationaboutinstallation,maintenance and
safety.
DisclaimerofLiability
RISENdoesnot assumeresponsibilityandexpresslydisclaimsliabilityforloss,damage, orexpensearising out
oforinanywayconnectedwithsuchinstallation,operation useormaintenancebyusingthismanual.RISEN
ssumesnoresponsibilityforany infringementofpatentsorotherrightsofthirdpartiesthatmayresult fromuseofthe
module. Nolicenseisgrantedbyimplicationorunderanypatentorpatentrights. Theinformationinthismanualis
elievedtobereliable, butdoesnotconstituteanexpressed and impliedwarranty. RISENreservestherighttomake
changestotheproduct,specifications,ormanualwithoutpriornotice..
GeneralInformation
Theinstallationofsolarmodulesrequiresagreatdegree ofskill and shouldonlybeperformedbyaqualified
licensedprofessional,including,withoutlimitation, licensedcontractorsandlicensedelectricians.
WARNING
All instructionsshouldbereadandunderstoodbeforeattemptingtoinstall, wireoperateandmaintainthe
photovoltaic module. Contactwithelectricallyactivepartsofthemodulesuchasterminalscanresult inburns,
sparks, andlethalshockwhetherthemoduleisconnectedordisconnected.
Theinstallerassumestheriskofall injurythatmightoccurduringinstallation,including,withoutlimitation,therisk
ofelectricshock.
PVmodulesgenerateDCelectricalenergywhenexposedtosunlightorotherlightsources.Althoughsingle
modulesproduce onlyalowvoltageandcurrent, shocksand burnsarestill apotentialhazard.
Toavoidthehazardofelectricshockandinjury,coverall overthefrontsurface ofPVmoduleswithadense
opaquematerialsuchasthecardboardboxduringinstalling andhandlingmodules.

Theshockhazardincreasesasmodulesareconnectedinparallelproducinghighercurrent.Theshockhazardincreases
asmodulesareconnectedinseriesproducinghighervoltages.Toavoidthehazardofelectricshock,workonlyunder
dryconditions,withdrymoduleandtools.
Donotstandorsteponamoduletoavoidthehazardofinjuryandthedamagetoamodule.
Donotdamagethebacksheetofamodule, toavoidthehazardofelectricshocksandfire.
Toavoidthehazardofelectricshockandinjury,childrenand unauthorizedpersonsshouldnotbeallowednearthe
installationofthesolarcell modules.
Toavoidthehazardofelectricshockandinjury, besuretogroundthemodulescompletely.
Toavoidthehazardoffireandinjury,do notdisassemblethemodule,orremoveany partinstalledbytheanufacturer.
Whencarryingamodule, twoormorepeopleshouldcarryit bytheframeandwearnon-slipglovestoavoidinjuryby
aslippingmoduletofeetorcutsbytheedgeofframe. Unauthorizedpersonsexceptthequalified licensedprofessional
shouldnotopenthecoverofthejunctionboxto avoidthehazardofelectricshock.
Donottouchterminalswhileamoduleisexposedtolight.Providesuitableguardstopreventyourselfcontacting
directlywith30 VDCorgreatertoavoidthehazardofelectricshockorinjury.afootorcutsbytheedgeofaframe,
and soon

DonotcarryamodulebywireorJunction boxtoavoidthehazardofelectricshockandinjuryoranytroublesina
module, whichit maycause.
Donotdropanythingonthesurfacesofmodule, toavoidthehazardofelectricshock, injury.
Toavoidthehazardofelectricshockandfire, besurethatothersystemcomponentsdonotcauseanyhazardofany
mechanicalorelectricalnaturetothemodule.Since sparksmaybegenerated, donotinstall modulewhereflammable
gasesorvaporsarepresent.
Neverleaveamoduleunsupportedorunsecured.
Donotdropmoduleanddonotallowobjectstofall onmoduletoavoidthehazardofinjuryoranytroublesin
modulesthatit maycause.
Donotuseorinstall brokenmodulestoavoidthehazardofelectricshockandinjury.
Donotartificiallyconcentrateonmoduletoavoidthehazardoffireoranytrouble.
DonottouchtheJunctionboxterminalstoavoidthehazardofelectricshockand injury.
Donotchangewiring ofbypass diodestoavoidthehazardofelectricshockandinjury.
CAUTIONS
Usemoduleforitsintendedfunction only.
Donottreatthebacksheetandfrontsurface withpaintoradhesivestoavoidanytroubles.
GENERALSAFETY

Followall permission, installation and inspection requirements. Beforeinstallingmodule, contactappropriate
authoritiestodeterminepermission,installation andinspectionrequirementsthatshouldbefollowed.Thisshouldbe
donenotonlyforinstallationsinconjunctionwithbuildings,butalsoformarineandmotorvehicleapplicationsfor
whichadditionalrequirementsmayapply.
Besurethattheconstructionintendedtoinstall modulesonitsrooftophasenoughstrength.Formodulesmountedon
roof, specialconstructionmayberequiredtohelpprovideproperinstallation.Bothroofconstructionand module
installationdesign haveaneffectonthefireresistance ofthebuilding.Improperinstallation maycontributeto
hazardsintheeventoffire.Additionaldevicessuchasgroundfault,fusesand disconnectsmayberequired.
Donotusemodulesofdifferentconfigurationsinthesamesystem.
Followall safetyprecautionsofotherusedcomponents.
INSTALLATION
Pleasereadthisguidecompletelybeforeinstallingorusingthemodules.Thissection containselectricaland
mechanicalspecificationsbeforeusingyourRISENphotovoltaicmodules.
Modulesshouldbefirmlyfixedinplace Inamannersuitabletowithstandall expectedloads,includingwindand
snowloads.
Donotdrill additionalmounting holesinthemoduleframes, asit will voidthewarranty.
Theappropriatematerialshouldbeemployedformountinghardwaretopreventthemoduleframe,mounting
structureandhardwareitselffromcorrosion. Pleaseinstall modulesattheplacewheretheyarenotshadedbythe
obstacleslikebuildingandtrees.Especially,pleasepayattentiontoavoidpartiallyshadingmodulesbysomething in
daytime.

PleasecontactyourlocaldealerwithQuestionsregardingmountingprofilesformodules.
Pleasecheckappearanceofthemodulesbeforeinstalling orusing.
NotesonInstallation
Clearance betweenthemoduleframeandthemountingsurfaceisrequiredtoallowcoolingairtocirculatearound
thebackofthemodule.Thisalsoallowsanycondensationormoisturetodissipate.
Themoduleshouldneverbesealedtothemountingsurfacewithsealantthatpreventsairfromcirculatingunderthe
module.Forroof-mountedmodules,theminimumDistancebetweentheroofandthemodulesshouldbe5cm(2
inch).Thismodulehas8 ellipticalholeforinstallation,withdimension9*14mm,4 oneachlongerside. Forinstallation
safety,werecommendthattheminimumtorqueofscrewbetween5~8N.m.
Werecommendinstallationmethodsshowninbelow.Insomeareas,localelectricalandbuildingcodesmaygovern
theinstallationanduseofPVmodules.
Pleasenotedall washers,nutandbolt arestainless steel.

StandardOperating Condition
Standardoperatingconditions(SOC)ofoursolarcell modulesareasfollows.Itisrecommendedthatthemodules
shouldbeoperatedintheSOC.Theinstallationplace withconditionsbeyondSOCorwithspecialconditions
shouldbeavoided.
1. Standardoperating condition
(1)Themodulesshouldbeoperatedonlyinterrestrialuseexceptspace useorotheruseinthespecialconditions.
(2)Theambienttemperatureshouldbewithinfrom-40 ~+80
(3)Therelativehumidityshouldwithinfrom45%to 95%.
(4)Theinstallationplace shouldbeless than1000mabovesealevel.But, installationatthealtitudeofmorethan
1000misallowedonlyifthewindpressureloadforamoduleislessthanBe30 lb/ft^2 146.5kg/m^2).
2. Specialconditions
(1) The ambient temperature and installationplace aredifferentfromtheSOC
(2)Thesalt damageisheavyatinstallation place.
3)Thehail andsnowdamagesareheavyatinstallation place
(4)Thesandanddustdamagesareheavyatinstallationplace
(5)Otherspecialconditions(withairpollution,orwithchemicallyactivevapor, etc)
SPECIFICATIONS
Notesonspecification
(1)PoweredspecificationsaremeasuredatStandardTestConditionIrradiance of: 1000W/m2, 25 cell
temperatureand solarspectralirradiance perIEC61215.
(2)Thecurrentoutputforthesemodulesasshown in theSpecificationsis measured at Standard test
conditions. Theseconditionsmaynotbefrequentlyobservedinactualpractice.
For questions regarding mountingprofilesformodules,pleasecontactyourlocaldealer.
WIRING
General
All wiringshouldbedoneinaccordance withapplicableelectricalcodes.
All wiringshouldbedonebythequalifiedlicensedprofessional.
Wiring shouldbeprotectedtohelpensurepersonalsafetyand topreventitsdamage.
All modulesconnectedinseriesshouldbeofthesamemodelnumber/type. Donotconnectmodulesinparallel
withoutusingaconnectionbox.
ElectricalSpecifications
SYP-180S, SYP-175S, SYP-170S, SYP-165S, SYP-160S,SYP-200S, SYP-210S, SYP-110S, SYP-85S

TEM
NO SYP-85S SYP-110S SYP-160
SSYP-165
SSYP-17
0S SYP-17
5S SYP-18
0S SYP-20
0S SYP-21
0S
MONO
orPOLY
MONO
Maximu
m
power(W
P)
85W 110W 160W
165W 170
W 175
W 180W 200
W 210
W
Maxim
um
power
Voltage
(V)
17.6 23.3 34.4 35 35.2
36.1
5 36.8
43 43.4
8
Maxim
um
power
current(
A)
4.83 4.71 4.66 4.71 4.83
4.84
4.89
4.65 4.83
Oren
circuit
voltage(
V)
21.9 29.2 43.2 43.3 43.5
43.7
44.2
52.
8 53.0
6
Short
circuit
current(
A)
5.14 4.99 5.01 5.06 5.1 5.12
5.18
5.0
1 5.14
Number
of
cells(pc
s)
36PCS 48PCS 72PCS 88PCS
Dimens
ion
(mm)
1200*550*3
5mm
1080*80
8*35mm 1580*808*35mm 1456*1070*50
mm
Note:
ModulecomplieswiththerequirementsofElectricalprotectionClass II.
Ratedelectricalcharacteristicsarewithin+/-5 percentofmeasuredvaluesatStandardTestConditionsof:1000 W/m2,
25 Ccell temperatureandirradiationofAM1.5 spectrum.
Undernormalconditions, aphotovoltaicmodulemayexperience conditionsthatproducemorecurrentand/orvoltage
thanreportedatStandardTestConditions.Accordingly, thevaluesofISCandVOCmarkedon ULListedmodules
shouldbemultipliedbyafactorof1.25 whendeterminingcomponentvoltageratings, conductorcapacities, fusesizes

and sizeofcontrolsconnectedtothemoduleoutput.
RefertoSection690-8 oftheNationalElectricCodeforanadditionalmultiplyingfactorof1.25 whichmaybe
applicable.
CNLmodelinstructionmanualsshall alsoincludeastatementthatinstallationshall beinaccordancewithCSAC22.1,
SafetyStandardforElectricalInstallations, CanadianElectricalCode, Part1.
DetailsforwiringinaccordancewiththeNEC, and thatthegroundingmethodoftheframeofarraysshall complywith
theNEC, article250.
Grounding
Thereisagroundinglabelandtwoholesonthemodule. Pleasereferthefigure1 forsizeand earth. Earthgrounding
conductorshouldbeinaccordance withlocalrequirementsortheIEC. Notestainless steelwashersareusedbetweenthe
groundwireandthemoduleframe(see picture2). Thesizeofgroundingholeis4mm. Thescrewis5.0mm.All washers
arewithinterdiameterof5.3mm.Thiswashersareusedtoavoidcorrosionduetodissimilarmetals. Tightenthescrew
with theminimumtorqueofscrewbetween 0.5~1N.m. Werecommendyou connectall moduleframestoanearthground.
Connectaseparategroundwiretooneoftheextramountingholeswithaself-tappingscrew. Theracksmustalsobe
groundedunlesstheyaremechanicallyconnectedbynutsand boltstothegrounded. Groundingisachievedbysecuring
thearrayframeforbothroofandfieldmountedapplications. Pleasenotedall washersand nutarestainless steel.
Figure1Figure2
Modulewiring
WhenyourPVsystemincludesothercomponents(batteries,chargecontrollers,inverters,etc.),be

suretofollowthesafetyrecommendationsoftheirmanufactures.
Thesemodulescontainfactoryinstalledbypass diodes.Ifthesemodulesareincorrectlyconnectedtoeachother,the
bypass diodesorcableorjunctionboxmaybedamaged.
Array Wiring
Theterm “array”isusedtodescribetheassemblyofseveralmodulesonasupportstructurewithassociated wiring.
Usecopperwirethatissunlightresistantand isinsulatedtowithstandthemaximumpossiblesystemopencircuit
voltage.Checkyourlocalcodesforrequirements.
ModuleTerminations
AjunctionboxasterminalenclosureisequippedforelectricalconnectionsonRISENmodules.Themodulesare
equipped
withMCplugsasterminalenclosure.UsetheseMCplugsforelectricalconnections.Pleasecontactyourlocaldealer
withquestionsregardingotherelectricalconnectionsformodules.
DIODES
Bypass Diodes
Byhavingabypass diode,theforcedcurrentwill bypass theshadedmoduleinaseriescircuit,therebyminimizing
moduleheating
and arraycurrentlosses.Typicallymodulesaresuppliedwitha12Ampdiodewhichhasrepetitivepeakforward
current50A
and peakreverse voltage40V diode. For12-volt systemsandhigher:Eachsolarmodulejunctionboxhasadiagram
illustrating
theproperdirectionfortheby-pass diodetobeinstalledbetweentwooftheterminalscrews.Whenthesolar
modulesareconnected
asindividualseriesstringsfirst, andthenthesestringsareconnectedinparallel,bypass diodesshouldbeusedineach
junctionbox.
Thisisthesimplestwiringarrangementformostinstallations.Ataminimumthebypass diodesmusthavethe
followingelectricalcharacteristics:
RatedAverageForwardCurrentAbovemaximumsystemcurrentathighestoperatingtemperature.
MAINTENANCE
Somemaintenance isrecommendedtomaintainoptimaloutputperformanceofsolarcell modules. Ifthemodule
surface becomesdirty, itmaycausereduction ofoutputpower.Itisrecommendedtocleanthesurfacewith
waterand softclothorsponge.Amildnon-abrasivedetergentmaybeappliedforthepersistentdirt.Andit isalso
recommendedto
inspecttheelectricalandmechanicalconnectionsannually.
If youneedelectricaland mechanicalinspectionormaintenance,it isrecommendedtohavetheauthorizedprofessional
carryout
theinspectionormaintenancetoavoidthehazardsofelectricshockorinjury.
Thereturnofanymoduleswill notbeacceptedbyRISENunless priorwrittenauthorization hasbeengivenbyRISEN.
Aspartofourpolicyofcontinuousimprovement, RISENreservestherighttochangeproductspecifications
atany timewithoutpriornotice.
This manual suits for next models
8
Table of contents
Other Risen Solar Panel manuals
Popular Solar Panel manuals by other brands

Hewalex
Hewalex KS2100F installation guide

TopSolar
TopSolar SOLAR5005022 user manual

Buderus
Buderus SKS 4.0 Series installation instructions

Yingli Solar
Yingli Solar YGE 60 Cell Series Installation and user manual

Schweizer
Schweizer Solrif Quick instruction manual

wurth
wurth Framed PV Assembly instructions