Models 9901i, 9915iand 9920i
Quick Start Installation Manual
111-326C
Installation DOs and DON’Ts
DO
• Shut off all power to system before installing.
• Read entire manual before installing.
• Make sure that all wiring conforms to national and
local codes.
DO NOT
• Install on voltages greater than 30 VAC.
• Short jumper across terminals on the gas valve or at the
system control.
• Connect ground to any terminal in this unit.
• Install on outside walls or in direct sunlight.
Recycling Thermostat
If this thermostat REPLACES a thermostat that contains mercury,
DO NOT discard the old thermostat in the regular trash. Mercury is harmful
to humans and the environment. For this reason, do not open, break, or
crush the mercury cell. If mercury leaks from a damaged cell, DO NOT
touch or handle mercury with bare hands. Use protective, non-absorbent
gloves to place mercury into a sealable container. Fill the container with
sand or another absorbent material and seal the container completely.
Return the mercury or mercury products, in a sealed container, to Invensys
Climate Controls or a local recycling center for proper disposal. If you have
any questions, call Robertshaw technical support at 1-800-445-8299.
Invensys Climate Controls
28C Leigh Fisher Blvd.
El Paso, TX 79906
Attn: Mercury Recycling Center
Select location for installation.
1
Open the case with a screwdriver. Place
in slot and gently pry forward at all four
locations.
Lift cover straight off. Do not pivot on
upper or lower retaining clips.
2
Mark mounting hole locations on wall.
3
Drill 3/16” holes at marked locations on
wall. Insert plastic anchors into holes.
4
Align unit base over plastic anchors
embedded in wall and secure with the
screws provided.
5
Connect wiring between unit and
furnace. For Model 9901i (1H/1C
furnace applications).
6
Cut
out
opening
a
b
1/4"
1-1/2"
1"
1
2
3
4
Mark mounting hole
locations on wall using
unit base as template.
Drill 3/16 holes
a
b
Press anchors into holes until flush.
Y1
R
C
E/W1
A1 O B G
Thermostat C - 24VAC Common
R - 24VAC
Y1 - 1st stage cooling
E/W1 - 1st stage heating
O - Not used
B - Not used
G - Fan
A1 - Aux contact
A2 - Aux contact
W2 - Not used
Y2 - Not used
L - Not used
TERMINAL DESIGNATIONS
C
R
Y
W
G
B
O
9901i
W2
A2
Y2
L
Equipment Wiring
Terminals
Please refer to
furnace installation
manual for proper
terminations
Remove 1/4” of insulation
from end of each wire
DELUXE
PROGRAMMABLE
THERMOSTATS
NOTE: For 9901i single stage heat
pump applications, place a jumper
between the E/W1 and Y1 terminals.
7
Connect wiring between unit and
furnace. For Model 9915i
(2H/2C furnace applications).
8
Replace cover on thermostat.
To replace cover, line up top and
bottom edges and push straight in.
DO NOT pivot on upper case clips.
Turn on power to unit and proceed
with programming per instructions on
the display or in the user’s manual.
1
2
Connect wiring between unit and
heat pump. For Model 9920i (2H/2C
heat pump applications).
9
To set your name and phone
number into the thermostat press
MENU, select INSTALLER
SETTINGS, and CONTACT
INFORMATION. The screen at the
bottom left should appear.
To enter your name press EDIT.
Use the UP or DOWN button to
scroll through the characters.
(DOWN gets you to the letters
faster.) After each letter press NEXT.
When you are done entering your
name, press ACCEPT.
Connect wiring between the
thermostat and the indoor sensor
(9020i) and the outdoor sensor
(9025i), if used. Use twisted pair
wiring (22AWG minimum) with a
maximum length of 300 feet
(or 100m).
Now enter your phone number.
Use the UP and DOWN arrow to
select the first number. Press NEXT.
When you have completed entering
your phone number, press ACCEPT.
The screen will return to the
INSTALLER SETTINGS. Finish
setting the thermostat for the
application.
Y1
R
C
E/W1
A1 O B G
Thermostat
C - 24VAC Common
R - 24VAC
Y1 - 1st stage cooling
E/W1 - 1st stage heating
W2 - 2nd stage heating
Y2 - 2nd stage cooling
L - Not used
O - Not used
B - Not used
G - Fan
A1 - Aux contact
A2 - Aux contact
TERMINAL DESIGNATIONS
W2
A2
Y2
C
R
Y1
W1
W2
Y2
G
B
L
O
9915i
Equipment Wiring
Terminals
Please refer to
furnace installation
manual for proper
terminations
Y1
R
C
E/W1
A1 O B G
Thermostat C - 24VAC Common
R - 24VAC
Y1 - 1st stage heating/cooling
E/W1- Emergency heat strip
W2 - 2nd stage heating
Y2 - 2nd stage cooling
L - System fault indicator
O - Cool active reversing valve
B - Heat active reversing valve
G - Fan
A1 - Aux contact
A2 - Aux contact
TERMINAL DESIGNATIONS
W2
A2
Y2
C
R
Y1
E
W2
Y2
G
L
B
L
O
9920i
Equipment Wiring
Terminals
Please refer to heat
pump installation
manual for proper
terminations
If terminal E is not supplied,
add jumper across E/W1 and
W2 on the thermostat.
Set Your Name Set Your Phone Number
Y1
R
C
E/W1
A1 O B G
Thermostat C - 24VAC Common
R - 24VAC
Y1 - 1st stage cooling
E/W1 - 1st stage heating
O - Cool active reversing valve
B - Heat active reversing valve
G - Fan
A1 - Aux contact
A2 - Aux contact
W2 - Not used
Y2 - Not used
L - Not used
TERMINAL DESIGNATIONS
C
R
Y1
G
B
O
9901i
W2
A2
Y2
L
Jumper
Equipment Wiring
Terminals
Please refer to heat
pump installation
manual for proper
terminations
CONTACT INFORMATION
BACK EDIT ACCEPT NEXT
CONTACT INFORMATION
AIR EXPERTS
CONTACT INFORMATION
AIR EXPERTS
ACCEPT NEXT
1
ACCEPT NEXT
CONTACT INFORMATION
AIR EXPERTS
1-800-445-8299
13 14
111-326C
Controls Americas
515 South Promenade Avenue
Corona CA 92879-1736
United States of America
Made in Mexico
The auxiliary contact relay can be used
in two ways.
a) Dry Contacts
The A1 and A2 contacts
are factory set as dry con-
tact points. Connect them
to the damper or economizer
as with any set of dry con-
tact terminals.
b) 24V Contacts
Place a jumper between R
and A2. When the relay is
energized, there will be 24V
at A1. To provide 24V power
to the economizer or damper,
wire the unit to the A1 and C
terminals on the thermostat.
Note: 1 amp max load on relay.
10
11
Patents Pending
www.about-i-series.com
Y1
R
C
E/W1
A1OBG
Thermostat
9901i
W2
A2
Y2
L
To Economizer / Damper
Y1
R
C
E/W1
A1 O B G
Thermostat
9901i
W2
A2
Y2
L
To Economizer / Damper
Jumper

Other manuals for 9915i

2

This manual suits for next models

2

Other Robertshaw Thermostat manuals

Robertshaw RS9320T User manual

Robertshaw

Robertshaw RS9320T User manual

Robertshaw 300-202 User manual

Robertshaw

Robertshaw 300-202 User manual

Robertshaw RS4110 User manual

Robertshaw

Robertshaw RS4110 User manual

Robertshaw RS8110 User manual

Robertshaw

Robertshaw RS8110 User manual

Robertshaw 9851i User manual

Robertshaw

Robertshaw 9851i User manual

Robertshaw 300-204 User manual

Robertshaw

Robertshaw 300-204 User manual

Robertshaw 9725i2 Installation and operating instructions

Robertshaw

Robertshaw 9725i2 Installation and operating instructions

Robertshaw 8401 User manual

Robertshaw

Robertshaw 8401 User manual

Robertshaw 9851i User manual

Robertshaw

Robertshaw 9851i User manual

Robertshaw 9415 User manual

Robertshaw

Robertshaw 9415 User manual

Robertshaw 9400 User manual

Robertshaw

Robertshaw 9400 User manual

Robertshaw RS2110C Series User manual

Robertshaw

Robertshaw RS2110C Series User manual

Robertshaw RS8110 User manual

Robertshaw

Robertshaw RS8110 User manual

Robertshaw RS3210 Series User manual

Robertshaw

Robertshaw RS3210 Series User manual

Robertshaw RS5220C User manual

Robertshaw

Robertshaw RS5220C User manual

Robertshaw RS9210 User manual

Robertshaw

Robertshaw RS9210 User manual

Robertshaw DSL-520P Manual

Robertshaw

Robertshaw DSL-520P Manual

Robertshaw 9200 User manual

Robertshaw

Robertshaw 9200 User manual

Robertshaw 300-202 User manual

Robertshaw

Robertshaw 300-202 User manual

Robertshaw 9555 User manual

Robertshaw

Robertshaw 9555 User manual

Robertshaw RS6110 User manual

Robertshaw

Robertshaw RS6110 User manual

Robertshaw 9915i User manual

Robertshaw

Robertshaw 9915i User manual

Robertshaw 9701i User manual

Robertshaw

Robertshaw 9701i User manual

Robertshaw 9915i User manual

Robertshaw

Robertshaw 9915i User manual

Popular Thermostat manuals by other brands

Swegon CASA W3 Smart user manual

Swegon

Swegon CASA W3 Smart user manual

Jackson Systems WZ1 Installation and operation manual

Jackson Systems

Jackson Systems WZ1 Installation and operation manual

Braeburn Premier 5000 user manual

Braeburn

Braeburn Premier 5000 user manual

Danfoss CF-RS instructions

Danfoss

Danfoss CF-RS instructions

momit Home installation guide

momit

momit Home installation guide

Warmup Tempo installation guide

Warmup

Warmup Tempo installation guide

Allied Control System Cloudwarm manual

Allied Control System

Allied Control System Cloudwarm manual

Baxi Luna 3 Comfort Operation instructions

Baxi

Baxi Luna 3 Comfort Operation instructions

Honeywell Lyric T5 Wi-Fi user guide

Honeywell

Honeywell Lyric T5 Wi-Fi user guide

Tesla TSL-TRV-GS361A user manual

Tesla

Tesla TSL-TRV-GS361A user manual

Hitachi ATW-RTU-02 Installation and operation manual

Hitachi

Hitachi ATW-RTU-02 Installation and operation manual

Tekmar 545 tekmarNet 4 brochure

Tekmar

Tekmar 545 tekmarNet 4 brochure

ClimateMaster ATC32U01 iGate user manual

ClimateMaster

ClimateMaster ATC32U01 iGate user manual

ESI ESRTD3 installation instructions

ESI

ESI ESRTD3 installation instructions

Johnson Controls A19BAC installation instructions

Johnson Controls

Johnson Controls A19BAC installation instructions

Honeywell INNCOM E529 Wiring guide

Honeywell

Honeywell INNCOM E529 Wiring guide

ICP TSTAT0711 owner's manual

ICP

ICP TSTAT0711 owner's manual

Hagen EXO TERRA PT2463 operating instructions

Hagen

Hagen EXO TERRA PT2463 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.