Rockwell Automation Allen-Bradley ASEM 6300B-A Series User manual

Installation Instructions
Original Instructions
ASEM 6300B Box PCs and 6300T Thin Clients
Catalog Numbers 6300B-xxA, 6300B-BMB, 6300B-xxF, 6300B-xxN, 6300T-BA, 6300T-BB
Summary of Changes
This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes.
Installation Precautions
Environment and Enclosure Information
European Union and UK Directive Compliance
This equipment meets the European Union and UK Directive requirements when installed within the European Union, UK, or EEA regions and have the CE or UK marking.
A copy of the declaration of the conformity is available at rok.auto/certifications.
Hazardous Locations
Only the ASEM 6300B-xxN and 6300T-BB Thin Client devices for hazardous locations are suitable for these location categories. All other products covered by this guide are
suitable for use in normal operating conditions.
The following catalog numbers are ASEM™ 6300B Edge Box PCs intended for use with FactoryTalk® Edge™ Manager:
• 6300B-BMBDNE-3DBAE01FNNBNN-NN1S
• 6300B-BMBDNE-7EDAE01FNNDNN-NN1S • 6300B-BMBDNE-3DBAE01NNNBNN-NN1S
• 6300B-BMBDNE-7EDAE01NNNDNN-NN1S
These catalog numbers have a unique Edge Virtualization Engine operating system (EVE-OS) orchestrated from FactoryTalk Edge Manager. If you have sent
the product to be returned or repaired, the device software and data has been erased and the EVE-OS has been reinstalled. For more information on
FactoryTalk Edge Manager, see publication 95055-UM007-EN-P and publication 95055-QS003-EN-P.
Topic Page
Update to European Union and UK Directive Compliance and addition of Hazardous Locations
content in Installation Precautions section 1
ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in
IEC 60664-1), at altitudes up to 2000 m (6561 ft) without derating.
This equipment is considered Group 1, Class A industrial equipment according to IEC/EN 61326-1. Without appropriate precautions, there can be potential
difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbance.
This equipment is considered open equipment, which means it must be mounted in an enclosure where the equipment can be operated from the front
panel.
The enclosure in which this equipment is installed must be accessed only with a key or tool, and only by trained and authorized personnel.
In addition to this publication, see the following:
• Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for more installation requirements.
• UL 50, CSA C22.2 No. 94.1, and IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures.
ATTENTION: This equipment is intended to operate in an industrial or control room environment, which uses some form of power isolation from the
public low-voltage mains. Some computer configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the
EMC Directive of the European Union or UK.
All I/O cables must be used only indoors.
Location Categories for Hazardous Locations
Region Rating Temperature Range
United States Class I Division 2, Groups A, B, C, D T4
Storage:
-20 °C ≤ Ta≤ +60 °C
(-4 °F ≤ Ta≤ +140 °F)
Operating:
0…+50 °C
(+32…+122 °F)
Class I Zone 2, IIC, T4
Canada Class I Division 2, Groups A, B, C, D T4
Class I Zone 2, IIC, T4
Europe (ATEX) II 3 G, Ex ec IIC T4 Gc
United Kingdom (UK)
=
=
=II 3 G, Ex ec IIC T4 Gc

2Rockwell Automation Publication 6300B-IN001G-EN-P - January 2024
6300B Box PCs and 6300T Box Thin Clients Installation Instructions
Restricted Access Location
UL/cUL MarkCompliance
UL/cUL Mark Compliance
Equipment with UL/cUL marks comply with the requirements of the following:
• UL 121201, UL 61010-1, and UL 61010-2-201
• CSA C22.2, No. 213, CSA C22.2, No 61010-1, and CSA C22.2, No. 61010-2-201
A copy of the certificate of compliance is available at rok.auto/certifications.
Battery Specifications
North American Hazardous Location Approval
The following information applies when operating this equipment in
hazardous locations.
Informations sur l’utilisation de cet équipement en environnements
dangereux.
Products marked "CL I, DIV 2, GP A, B, C, D" are suitable for use in Class I
Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous
locations only. Each product is supplied with markings on the rating
nameplate indicating the hazardous location temperature code. When
combining products within a system, the most adverse temperature code
(lowest "T" number) may be used to help determine the overall temperature
code of the system. Combinations of equipment in your system are subject
to investigation by the local Authority Having Jurisdiction at the time of
installation.
Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu'à une utilisation
en environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non
dangereux. Chaque produit est livré avec des marquages sur sa plaque
d'identification qui indiquent le code de température pour les environnements
dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de
température le plus défavorable (code de température le plus faible) peut être
utilisé pour déterminer le code de température global du système. Les
combinaisons d'équipements dans le système sont sujettes à inspection par les
autorités locales qualifiées au moment de l'installation.
WARNING:
Explosion Hazard –
• Do not disconnect equipment unless power has been
removed or the area is known to be nonhazardous.
• Do not disconnect connections to this equipment unless
power has been removed or the area is known to be
nonhazardous. Secure any external connections that mate to
this equipment by using screws, sliding latches, threaded
connectors, or other means provided with this product.
• Substitution of components may impair suitability for Class I,
Division 2.
• If this product contains batteries, they must only be changed
in an area known to be nonhazardous.
AVERTISSEMENT:
Risque d’Explosion –
• Couper le courant ou s'assurer que l'environnement est classé non
dangereux avant de débrancher l'équipement.
• Couper le courant ou s'assurer que l'environnement est classé non
dangereux avant de débrancher les connecteurs. Fixer tous les
connecteurs externes reliés à cet équipement à l'aide de vis,
loquets coulissants, connecteurs filetés ou autres moyens fournis
avec ce produit.
• La substitution de composants peut rendre cet équipement
inadapté à une utilisation en environnement de Classe I, Division 2.
• S'assurer que l'environnement est classé non dangereux avant de
changer les piles.
WARNING: ASEM 6300 devices for hazardous locations must be
installed in a restricted access location. Verify that restricted
access locations meet these conditions for the ASEM 6300 devices
for hazardous locations:
• Access is gained only by service personnel or by users who
have been instructed on the reasons for restrictions to a
location and about any precautions to be taken.
• Access is by using a tool, a lock and key, or other means of
security controlled by the authority responsible for the
location.
AVERTISSEMENT: Les dispositifs ASEM6300 pour environnement
dangereux doivent être installés dans une zone d’accès restreint.
Vérifiez que les zones d’accès restreint répondent aux conditions
suivantes d’installation pour dispositifs ASEM6300 adaptés aux
environnements dangereux:
• L’accès est réservé au personnel de service ou aux utilisateurs qui
sont informés des motifs de restrictions d’accès à cette zone et des
précautions à prendre.
• L’accès se fait à l’aide d’un outil, un verrou et une clé, ou tout autre
moyen de sécurité contrôlé par l’autorité responsable de la zone.
EXPLOSION HAZARD: Do not connect or disconnect any
accessories to ASEM 6300 devices for hazardous locations
unless power has been switched off and the area is known to
be non-hazardous.
Before power is switched on, verify that any adapter, cable, or
power connection accessory is fully inserted in its port. For
adapter and cable accessories, verify that latches are
engaged, and any screws are fully engaged and tightened.
Failure to do so could result in an electric arc that can cause
an explosion in a hazardous location.
RISQUE D’EXPLOSION: Ne pas connecter ou déconnecter tout
accessoire destinés aux dispositifs ASEM6300 pour environnement
dangereux tant que l’alimentation n’a pas été coupée et que la zone
n’est pas réputée non dangereuse.
Avant la mise sous tension, vérifiez que tous les adaptateurs, câbles
ou accessoires de connexion d’alimentation sont correctement
insérés dans leur port. Pour les accessoires d’adaptateur et de câble,
vérifiez que les verrouillages sont engagés et que les vis sont
complètement insérées et serrées.
Le non respect de cette précaution pourrait entraîner un arc
électrique susceptible de provoquer une explosion dans un
environnement dangereux.
WARNING: Explosion hazard. Batteries must only be replaced
in an area free of ignitable gas concentrations.
AVERTISSEMENT: Risque d'explosion. Les piles ne doivent être
remplacées que dans une zone exempte de concentrations de gaz
inflammables.
Battery
Type Coin cell
Battery Pack
(accessory)
Rating NiMH
IEC Model No. CR2032 Voltage 12V
Voltage 3V Amperage 2500 mAh
Electrochemical System Lithium

Rockwell Automation Publication 6300B-IN001G-EN-P - January 2024 3
6300B Box PCs and 6300T Box Thin Clients Installation Instructions
Installation Requirements and Guidelines
Follow these guidelines to make sure that your 6300B box PC or 6300T thin client provides service with excellent reliability.
Installation Site Requirements
• Your installation site:
- must have sufficient power,
- must be indoors and non-hazardous,
- must not expose your box PC or thin client to direct sunlight, and
- must be placed in an industrial or control room environment, which uses some form of power isolation from the public, low voltage mains.
• The surrounding air temperature must not exceed the maximum temperature for your box PC or thin client, especially when mounted in an enclosure.
The surrounding air temperature ranges are:
- 0…+55 °C (+32…+131 °F) with the Intel Atom® x5 processor
- 0…+50 °C (+32…+122 °F) with the Intel Atom x7 processor and Intel® Core™ i3, Core i5, and Core i7 processors
• Your 6300B box PC or 6300T thin client can be stored in a surrounding air temperature range of -10…+60 °C (14…140 °F).
• Operating and storage: 20%…90% relative humidity (RH) noncondensing
Mounting Requirements
Follow these requirements to mount your 6300B box PC or 6300T thin client.
• For use in a hazardous location, the 6300B must be installed in an enclosed panel.
• Choose a suitable, ergonomic mounting height.
• Only mount your 6300B box PC or 6300T thin client in a vertical, 0° upright) position where the ground screw is at the bottom.
• Mount your 6300B box PC or 6300T thin client so there is at least 20 mm (0.79 in.) of clearance on each side for the circulation necessary for cooling.
DC Power Supply Guidelines
Follow these guidelines to select the DC power supply for your box PC or thin client.
• Your 6300B box PC or 6300T thin client must be powered with a voltage of 24V DC (18…32V DC).
• The DC supply should be able to provide momentary current of at least 10 A for up to 400 µs for 6300B box PC or 6300T thin client inrush current.
• The nominal output power must be 25% larger than the drained power.
• The output voltage rise time has to be less than 100 ms.
• Consider the working temperature and thermal derating of the power supply.
Installation
Follow these steps to mount your 6300B box PC or 6300T thin client, connect DC power wiring, then attach I/O cables and DC power.
Mount
Use Supplied Brackets
To mount your 6300B box PC or 6300T thin client with supplied brackets:
1. Locate and drill holes for four M4x20 stainless steel screws against your mounting surface. See Approximate Dimensions on page 6.
2. Partially tighten the four M4x20 stainless steel screws (not supplied) into your mounting surface. Leave enough space to hang the brackets.
3. Align the keyhole slots on the top bracket with the top two screws.
4. Align the slots on the bottom bracket with the bottom two screws.
5. Slide your box PC or thin client downward until all four screws are at the top of each bracket slot.
6. Tighten the four screws flush against your mounting surface.
ATTENTION: For applications with an AC power source, the shipped AC-to-DC power adapter must be plugged into a grounded outlet to maintain an
electrically safe installation. An AC power supply cannot be used in a hazardous location.
To mount and connect your 6300B box PC or 6300T thin client, these tools are required:
Mounting Tools:
• Safety glasses
• Drill and 4 mm drill bit
• #2 Phillips screwdriver
• Adjustable torque screwdriver with bits
• DIN Rail (for DIN Rail installation only)
Connection Tools:
• Wire stripper/crimper/cutter tool
•VariousI/Oshieldedcables
• DC power supply
Select models feature optional PCIe slots, removable drive slots, an internal USB port, and/or CFAST slot. Before mounting, install these peripherals. See
Figure 6 for peripheral locations and the User Manual for your respective model (see Additional Resources on page 9) to properly install these peripherals.

4Rockwell Automation Publication 6300B-IN001G-EN-P - January 2024
6300B Box PCs and 6300T Box Thin Clients Installation Instructions
Use a DIN Rail Bracket — 6300B-DRF, 6300B-DRN, and 6300T-BBD
1. Plan your DIN Rail installation according to the approximate dimensions shown in Figure 5 on page 7.
2. Install your box PC onto the installed DIN Rail according to the DIN Rail installation instructions, publication 6300V-IN002.
Connect DC Power Wiring
Follow these steps to connect your 6300B box PC or 6300T thin client to a DC power source.
Step A: Install the Ground Wire
1. Turn off the main power switch or breaker.
2. Remove the supplied nut, eyelet terminal, and washers from the ground screw.
3. For earth ground, fasten a 2.5 mm2(14 AWG) or larger external wire to the eyelet terminal.
4. Use a ground wire with an insulation color approved by local inspection authority.
5. Install the ground wire to the ground screw in the sequence shown at the right.
6. Tighten the nut to the ground screw.
7. Proceed to Step B: Attach the Power Connector Assembly.
Step B: Attach the Power Connector Assembly
The factory-supplied connector assembly provides strain relief for the DC power wires by reducing their movement.
For 6300B-BMA, 6300B-BMB, 6300B-DRA, and 6300T-BA
See Figure 1 and Table 1 when performing the following steps to successfully install the DC power connector assembly steps.
Figure 1 - DC Power Connector Assembly Steps
IMPORTANT A DIN Rail is not supplied with the book mount bracket. An installed DIN Rail is the responsibility of the customer.
ATTENTION: Your 6300B box PC or 6300T thin client must have its own supply disconnect. On models with an available UPS connection, use a UPS to
help protect against unexpected power failure or power surges.
IMPORTANT The DC terminal block that is shown is for illustrative purposes only. Your DC terminal block may differ in size, shape, and color.
Table 1 - DC Power Connection Assembly: 6300B-BMA, 6300T-BA, 6300B-BMB
Note No. Description 6300B-BMA, 6300T-BA 6300B-BMB
1DC+ (24V DC nominal)
recommended power wire size 1.5 mm2
(16 AWG) 2.5 mm2
(14 AWG)
2DC- (0V DC)
recommended power wire size
3 Stripped wire length 7 mm (0.275 in) 7 mm (0.275 in)
4Torque range to secure
DC power wires 0.22...0.25 N•m
(0.16...0.18 lb•ft) 0.5...0.6 N•m
(0.37...0.4 lb•ft)
5Torque value to reinstall
DC terminal block to the chassis. 0.3 N•m
(0.22 lb•ft) 0.3 N•m
(0.22 lb•ft)
Sequence No. Description
1 Toothed washer
2 Eyelet terminal
3Washer
4Lockwasher
5Nut
12345
A
B C DE
F
1
2
4
4
3
3
5
5
1
2
4
4
3
3
5
5
6300B-BMB
6300B-xxA and 6300T-BA

Rockwell Automation Publication 6300B-IN001G-EN-P - January 2024 5
6300B Box PCs and 6300T Box Thin Clients Installation Instructions
To assemble and attach the DC power connector assembly:
1. Remove the DC terminal block from the chassis of your box PC.
2. Open the power connector assembly kit that ships with your box PC or thin client (A of Figure 1).
3. Insert the cable tie through the slots of the appropriate connector half (B of Figure 1).
4. Strip the end of each DC power wire to the length specified in Table 1.
5. Insert each stripped end into the DC terminal block as shown in the figure at right.
6. Tighten the screws on top of the terminal block to secure the DC power wires to the torque value in Table 1 on page 4.
7. Slide the connector half with the attached tie onto the end of the DC terminal block (C of Figure 1).
8. Tighten the cable tie so it is snug against the terminal wires.
9. Use cutting pliers to cut the excess part of the cable tie (D of Figure 1).
10. Install the white label supplied with the kit (E of Figure 1).
11. Align and install the other connector clamp half to complete the assembly (F of Figure 1).
When it is installed correctly, both tabs of the clamp half lock into place.
12. Reconnect the DC terminal block with the connector assembly to the chassis of your box PC or thin client.
13. Torque the DC terminal block flange screws to the values in Table 1 on page 4.
14. Proceed to Attach I/O Cables and DC Power.
For 6300B-xxF, 6300B-xxN, and 6300T-BB
To assemble and attach the DC power connector assembly, perform the following steps.
1. Remove the DC terminal block from the chassis of your box PC.
2. Strip 10 mm (0.4 in.) from the end of four different-colored wires.
3. Press the spring connection tabs on the DC terminal block, and insert each stripped end of wire according to Table 2.
4. Release the spring connection tabs after the stripped end of each wire has been fully inserted in the appropriate terminal connection.
5. Reconnect the DC terminal block to the chassis of your box PC or thin client.
6. Torque the DC terminal block flange screws to 0.3 N•m (0.22 lb•ft).
7. Proceed to Attach I/O Cables and DC Power.
Attach I/O Cables and DC Power
1. Connect shielded I/O cables to your 6300B box PC or 6300T thin client. See Figure 6 on page 7 for I/O port locations of your particular model.
2. Connect the DC power to your 6300B box PC or 6300T thin client.
Light-emitting diode (LED) status indicators illuminate on your 6300B box PC or 6300T thin client. For a description of these LED status indicators,
see Technical Data on page 6.
IMPORTANT DC power wires must be of stranded copper and certified for at least +85 °C (+185 °F) operation.
Use the white label for identification or other information.
Table 2 - DC Power Connection Assembly
Note No. Abbreviation Function
1 + + Input voltage (fused)
2 — - Input voltage
3SYSOFF SystemOFFinput
4 PS Power status output (0.5 A limited)
IMPORTANT Use stranded copper wire sized 1.5 mm2(16 AWG) and certified for at least 85 °C (185 °F) operation.
IMPORTANT To comply with EN 61326-1, the following cable types must be shielded: Digital I/O, DisplayPort, DVI-D, LAN, RS-232 DB9M, USB 2.0, and USB 3.0.
All I/O cables must be used only indoors, and USB cables must be less than 3 m (9.84 ft) in length.
Whenever two connected pieces of equipment are far apart, it is possible that their ground connections could be at another potential level.
To overcome these possible grounding problems, the following bonding methods are recommended:
Method 1: Connect the data cable shields to the equipotential bonding rail on both sides before connecting the cable to the interfaces.
Method 2: Use an equipotential bonding cable (16 mm2or #6 AWG) to connect the grounds between the 6300B Box PC/6300T Thin Client and a
connected monitor.
IMPORTANT • All DC powered models require a safety extra low voltage (SELV) power supply. The internal power supply is protected against reverse polarity.
• To minimize ground loop currents and noise, we recommend that DC powered models use only one grounded connection.
See Step A: Install the Ground Wire on page 4 for the ground connection on these models.
• Follow all guidelines as stated in DC Power Supply Guidelines on page 3.
1
2
3
4
1
2
3
4

6Rockwell Automation Publication 6300B-IN001G-EN-P - January 2024
6300B Box PCs and 6300T Box Thin Clients Installation Instructions
Technical Data
Approximate Dimensions
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Figure 2 - 6300B-xxA and 6300T-BAx
Figure 3 - 6300B-BMB Box PC
(in.)]
4.50
(0.18) 8.00
(0.31)
4x Ø4.00
(0.16)
8.00
(0.31)
127.50
(5.02)
36.00
(1.42)
39.40
(1.55)
20.00
(0.79)
20.00
(0.79)
1.50
(0.06)
100.00
(3.94)
100.00
(3.94)
8.00
(0.31)
Front View (Vertical Upright) Side View
101.50
(4.00)
100.00
(3.94)
20.00
(0.79)
6.95
(0.27)
6.95
(0.27)
33.76
(1.33)
32.34
(1.27)
33.90
(1.33)
25.50
(1.00)
100.00
(3.94)
39.54
(1.56)
Front View (Vertical Upright) Side View
6300B-BMA, 6300T-BAB 6300B-DRA, 6300T-BAD
19.00
(0.75)
90.00
(3.54)
225.00
(8.86)
256.50
(10.10)
19.00
(0.75)
230.00
(9.06)
268.00
(10.55)
5.50
(0.22)
20.00
(0.79)
4.50
(0.18)
4.20
(0.17)
50.00
(1.97)
90.00
(3.54)
6.00
(0.24)
20.00
(0.79)
Front View (Vertical Upright) Side View
100.00
(3.94)
25.00
(0.98)
6.00
(0.24)
5.50
(0.22)
4x Ø4.00
(0.16)
19.00
(0.75)
19.00
(0.75)
4.00
(0.16)
225.00
(8.86)
230.00
(9.06)
150.00
(5.91)
4x Ø 9.00
(0.35)
268.00
(10.55)
25.00
(0.98)
256.50
(10.10)
150.00
(5.91)
Front View (Vertical Upright) Side View
6300B-BMBDNE*, 6300B-BMBDNF*, 6300B-BMBDNG* 6300B-BMBDNH*, 6300B-BMBDNI*, and 6300B-BMBDNJ*
Top View Top View

Rockwell Automation Publication 6300B-IN001G-EN-P - January 2024 7
6300B Box PCs and 6300T Box Thin Clients Installation Instructions
Figure 4 - 6300B-BMF, 6300B-BMN, and 6300T-BBB
Figure 5 - 6300B-DRF, 6300B-DRN, and 6300T-BBD
I/O Port and Peripheral Connections
Figure 6 - I/O Port and Peripheral Slot Locations
The I/O port and slot locations of your shipped product may vary from the drawings that are shown in Figure 6.
20.00
(0.79)
20.00
(0.79)
2.00
(0.08)
8.25
(0.32)
4.50
(1.85)
15.00
(0.59)
77.00
(3.03)
140.00
(5.51)
127.25
(5.00)
47.00
(18.50)
15.00
(0.59)
100.00
(3.94)
100.00
(3.94)
Front View (Vertical Upright) Side View
15.00
(0.59) 15.00
(0.9)
8.25
(0.32)
10.00
(0.39)
4.50
(1.77) 47.00
(1.85)
77.00
(3.03)
140.00
(5.51) 117.25
(4.61)
2.00
(0.79)
20.00
(0.79)
20.00
(0.79)
100.00
(3.94)
100.00
(3.94)
4x Ø4.00
(1.57)
Side ViewFront View (Vertical Upright)
6300B-BMF 6300B-BMN, 6300T-BBB
2.00
(0.08)
23.00
(0.91)
8.50
(0.33)
20.00
(0.79)
47.00
(1.85)
26.00
(1.02)
26.00
(1.02)
79.00
(3.11) 100.00
(3.94)
100.00
(3.94)
100.00
(3.94) 50.00
(1.97)
27.00
(1.06)
Side ViewFront View (Vertical Upright)
20.00
(0.79)
26.00
(1.02)
26.00
(1.02)
27.00
(1.06)
79.00
(3.11)
100.00
(3.94)
20.00
(0.79)
2.00
(0.08)
8.50
(0.33)
23.00
(0.91)
100.00
(3.94)
50.00
(1.97)
47.00
(1.85)
100.00
(3.94)
6300B-DRF 6300B-DRN, 6300T-BBD
Side ViewFront View (Vertical Upright)
Ethernet LAN Port (2 qty.)
USB 3.0 (2 qty.)
DisplayPort
RS232-DB9M
USB 3.0 (2 qty.)
future option
UPS
DC Power
Ethernet LAN
Port (2 qty.)
USB 3.0 (2 qty.)
DisplayPort
24V DC Power
24V DC Power
DisplayPort
RS232-DB9M
USB 3.0 (2 qty.)
USB 3.0 (2 qty.)
future option
UPS
Digital I/O
Ethernet LAN
Port (4 qty.)
SATA III
Removable
Drive
(2 qty.)
USB 3.0 (2 qty.)
USB 2.0 (2 qty.)
Ethernet
LAN Port (2 qty.)
Ethernet LAN Port (2 qty.)
PCIe (Gen 3)
Expansion
RS232-DB9M
DVI-D
24V DC
Power
UPS
future option
USB 3.0
CFAST
SATA III
Card
Battery
DisplayPort
PCIe (Gen 3)
Expansion
Front View (Vertical Upright) Front View (Vertical Upright) Front View (Vertical Upright)
Front View (Vertical Upright)
Top View
6300B-BxxA, 6300T-BA 6300B-BxxF
6300B-xxN and 6300T-BB
6300B-BMB

8Rockwell Automation Publication 6300B-IN001G-EN-P - January 2024
6300B Box PCs and 6300T Box Thin Clients Installation Instructions
LED Status Indicators and Buttons
‘’
ATTENTION: When you connect power to your box PC or thin client for the first time, these actions occur:
• The default UEFI setting automatically starts your box PC or thin client after it is plugged into a power source.
• For 6300B box PCs with a Microsoft Windows® operating system (OS), you must read and accept an End-User Setup procedure.
Do not disconnect power from the system until after the Microsoft Windows Setup procedure is completed.
If power is disconnected during this procedure, it can result in a corrupted system image.
Table 3 - Description of LED Status Indicators and Buttons
Cat. No. Note No. Description Color Status/Function
6300B (-BMA, -BMF, -BMN, -DRF, -DRN) Box PCs
and 6300T Thin Clients 1Standby /
Power On
No color The box PC or thin client is powered off.
Green The box PC or thin client is powered on.
Yellow The box PC or thin client is safe to power off; the OS has been shut down successfully.
Flashing Green The box PC or thin client is in a low-power state; the current session information is
being stored in RAM.
2 Mass Storage Yellow When lit, access to a mass storage device (SSD or CF) is happening through a SATA
channel.
3⚠— Not implemented.
4Thermal Alarm/
Low Battery
Red A thermal sensor on the motherboard near the CPU has exceeded the thermal limit of
85 °C (185 °F).
Flashing Red The clock battery power is below 2.5V; consider replacing.
IMPORTANT: At 2V, data and time loss is possible.
5Power /
System Reset —For the main reset of the system.
Press this button once to restart and reset the system state.
6WDR — Not implemented.
7 Datalink
No color No Datalink is present.
Green Datalink is established.
Flashing Green Datalink is established and there is data transfer.
8 Data Speed
No color 10 Mbps
Green 100 Mbps
Yellow 1000 Mbps (1 Gbps)
6300B-BMB Box PCs
1PowerOn
No Color The box PC or thin client is powered off.
Green The box PC or thin client is powered on.
Yellow The box PC or thin client is safe to power off; the OS has been shut down successfully.
2UPS(optional)
No Color No UPS battery pack is installed.
Green The box PC or thin client is powered by an external 24V DC source.
Yellow The UPS battery pack is disconnected.
Flashing Green The external 24V DC source is lost, and the box PC or thin client is powered by the UPS.
3 Mass Storage Yellow When lit, access to a mass storage device (SSD or CFast) is happening through a
SATA channel.
4Thermal Alarm /
Low Battery
Red A thermal sensor on the motherboard near the CPU has exceeded the thermal limit of
+85 °C (+185 °F).
Flashing Red The real-time clock (RTC) battery is lower than 2.5V. Replace before the battery goes
lower and risks loss of date and time.
5Watchdog Green The watchdog is working.
Red The watchdog timer has expired.
6PLC —Notapplicable.
7BUS
8PowerOnButton — Turns the box PC on or off.
9SystemReset —
Forces an internal reset, as if power was lost temporarily and then returned.
IMPORTANT: Use system reset only if there are no better options, like keyboard or
mouse commands. System reset can cause data loss and corruption to the OS.
10 Watchdog Reset — Turns off the watchdog LED (Note No. 5).
11 PLC Run / Stop /
Reset — Not implemented.
12 Datalink
No Color No Datalink is present.
Green Datalink is established.
Flashing Green Datalink is established and there is data transfer.
13 Data Speed
No Color 10 Mbps
Green 100 Mbps
Yellow 1000 Mbps (1 Gbps)
1
2
3
4
5
6
RST
WDR
8
7
Front View
(Vertical Upright)
8
1
29
3
45
7
611
10
12
13
12
13
POWER
UPS
HDD
OT/LB
WD
PLC
BUS
Front View
(Vertical Upright)
Top View

Rockwell Automation Publication 6300B-IN001G-EN-P - January 2024 9
6300B Box PCs and 6300T Box Thin Clients Installation Instructions
Additional Resources
This publication provides basic installation instructions. For more information, see the following Rockwell Automation publications at https://rok.auto/literature.
Resource Description
ASEM 6300B Book/DIN Mount Box PCs and 6300T Book/
DIN Mount Thin Clients User Manual, publication 6300B-UM001 Provides details on how to install, configure, operate, and troubleshoot the 6300B book mount box PCs and
6300T book mount thin clients (Cat. Nos. 6300B-BMA, 6300B-BMB, and 6300T-BAx1).
ASEM 6300B Wall Mount Box PCs User Manual, publication 6300B-UM002 Provides details on how to install, configure, operate, and troubleshoot the 6300B wall mount PCs
(Cat. Nos. 6300B-PBCx and 6300B-PBDx).
ASEM 6300B Machine Mount Box PC, publication 6300B-UM003 Provides details on how to install, configure, operate, and troubleshoot the 6300B machine mount box PCs
(Cat. No. 6300B-MM).
ASEM 6300 Industrial Computer and Monitor Specifications Technical Data,
publication 6300-TD001 Provides technical specifications for ASEM 6300 industrial computers and monitors.
Wall-mount and DIN Rail Brackets for 6300B Box PCs and
6300T Thin Clients, publication 6300V-IN002 Provides installation instructions to secure 6300V-BWALLA wall-mount brackets or 6300V-BDINA DIN Rail bracket
to a 6300B box PC or 6300T thin client.
FactoryTalk Edge Manager User Manual, publication 95055-UM007-EN-P
Provides instructions on operating the FactoryTalk Edge Manager, applicable to these catalog numbers with
EVE-OS installed:
• 6300B-BMBDNE-3DBAE01FNNBNN-NN1S
• 6300B-BMBDNE-7EDAE01FNNDNN-NN1S • 6300B-BMBDNE-3DBAE01NNNBNN-NN1S
• 6300B-BMBDNE-7EDAE01NNNDNN-NN1S
FactoryTalk Edge Manager Quick Start Guide, publication 95055-QS003-EN-P
Provides quick start instructions for FactoryTalk Edge Manager, applicable to these catalog numbers with
EVE-OS installed:
• 6300B-BMBDNE-3DBAE01FNNBNN-NN1S
• 6300B-BMBDNE-7EDAE01FNNDNN-NN1S • 6300B-BMBDNE-3DBAE01NNNBNN-NN1S
• 6300B-BMBDNE-7EDAE01NNNDNN-NN1S
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines to install a Rockwell Automation industrial system.
Product Certifications website, rok.auto/certifications Provides declarations of conformity, certificates, and other certification details.

Publication 6300B-IN001G-EN-P - January 2024 | | Supersedes Publication 6300B-IN001F-EN-P - February 2023
Copyright © 2024 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur
Vendor Code 80460002.06
DIR 10005614692 (Version 06)
Allen-Bradley, ASEM, Edge, expanding human possibility, FactoryTalk, Rockwell Automation, and ThinManager are trademarks of Rockwell Automation, Inc.
Microsoft and Windows are trademarks of Microsoft Corporation.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
*PN-592308*
PN-592308
Waste Electrical and Electronic Equipment (WEEE)
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
At the end of life, this equipment should be collected separately from any unsorted municipal waste.
Rockwell Automation Support
Use these resources to access support information.
Documentation Feedback
Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback.
Technical Support Center Find help with how-to videos, FAQs, chat, user forums, Knowledgebase, and product notification updates. rok.auto/support
Local Technical Support Phone Numbers Locate the telephone number for your country. rok.auto/phonesupport
Technical Documentation Center Quickly access and download technical specifications, installation instructions, and user manuals. rok.auto/techdocs
Literature Library Find installation instructions, manuals, brochures, and technical data publications. rok.auto/literature
Product Compatibility and Download Center (PCDC) Download firmware, associated files (such as AOP, EDS, and DTM), and access product release notes. rok.auto/pcdc
This manual suits for next models
9
Table of contents
Other Rockwell Automation Server manuals
Popular Server manuals by other brands

Dell
Dell POWEREDGE R710 Getting started guide

Western Digital
Western Digital ActiveScale X100 Support guide

Fujitsu
Fujitsu PRIMERGY BX924 S3 operating manual

Supermicro
Supermicro SUPERSERVER 1015B-M3 user manual

Dell EMC
Dell EMC PowerEdge T340 Installation and service manual

Dell
Dell DL4300 Getting Started With Your System

NEC
NEC Univerge SV8100 Features and specifications manual

Dell EMC
Dell EMC PowerEdge R6415 Installation and service manual

ANTAIRA
ANTAIRA ute-404k installation guide

Dell
Dell PowerEdge T710 Hardware installation instructions

Supero
Supero 2U Twin3 SuperServer 2015TA-HTRF user manual

IBM
IBM BladeCenter JS21 Types 8844 Service guide