9
Jun. 2011 BF-3(T)
Verifying the Version
1. Turn down all controls completely counterclockwise (to MIN or
MOMENTARY).
2. Hold down the pedal and connect the AC adaptor to the DC IN jack.
The CHECK LED lights up and the unit enters the Test Mode.
After approximately 2 seconds, the CHECK LED lights up or flashes,
indicating the version as shown below.
Examples: Illuminated orange: Version 1.00
2 flashes: Version 2.00
* Version 1.00 is the BF-3 (older type), and version 2.00 is the BF-3A (new type).
After the version information is displayed, execution changes to 1. DSP
and CPU Check.
3. Release the pedal.
Data Backup and Restore
Operations
The setting for the sleep mode is saved on the Main Board even when the
power has been switched off, but neither verification of its status (ON or OFF)
nor backing up the setting is possible. When the Main Board has been
replaced, the sleep mode is returned to its default (ON). For more information
about the sleep mode, refer to About Sleep Mode (Owner’s Manual, p. 14).
No user data other than the setting for the sleep mode is saved.
Performing a Factory Reset
This product has no factory-reset feature.
Updating the System
A system update cannot be performed for this product. If an update is
required, replace with an updated circuit board. Updates can be accomplished
only at the factory.
Test Mode
Items Required
• AC adaptor (PSA-series device)
• Amp-equipped monitor speaker x 1
• Signal generator x 1
• Oscilloscope x 1
• Noise meter x 1
• Stabilized power supply x 1
• 47-kΩdummy plug x 1
Test Items
1. DSP and CPU Check (p. 10)
2. Volume Check (p. 10)
3. CODEC (DAC) Check (p. 10)
4. CODEC (ADC) L-channel Check (p. 11)
5. CODEC (ADC) R-channel Check (p. 11)
6. Battery Operation Check (p. 11)
7. Noise Check (p. 11)
*6. Battery Operation Check is carried out in the normal mode, and not in the
Test Mode. 7. Noise Check is carried out in its own mode.
Entering the Test Mode
1. Turn down all controls completely counterclockwise (to MIN or
MOMENTARY).
2. Hold down the pedal and connect the AC adaptor to the DC IN jack.
The CHECK LED lights up and the unit enters the Test Mode.
3. Release the pedal.
* The unit cannot enter the Test Mode unless all controls are turned down to
minimum. If the minimum value is not detected for all volume controls due to a
problem such as a defective volume control, the Test Mode cannot be entered.
Quitting the Test Mode
Depress the pedal.
* If an error occurred in 1. DSP and CPU Check, depressing the pedal does not
quit the mode. In such cases, disconnect the AC adaptor to switch off the power.
* At 5. CODEC (ADC) R-channel Check, depressing the pedal does not quit
the mode. In this case, either adjust the MODE control to any setting other than
ULTRA and depress the pedal, or disconnect the AC adaptor to switch off the
power.
Selecting a Test Item
1. Enter the Test Mode.
2. After the version information is displayed, 1. DSP and CPU Check is
carried out automatically, and if no error occurs, the CHECK LED lights
up green.
3. Use the MODE control to select the desired test item.
MOMENTARY: 2. Volume Check
GATE/PAN: 3. CODEC (DAC) Check
STANDARD: 4. CODEC (ADC) L-channel Check
ULTRA: 5. CODEC (ADC) R-channel Check