RotoBed Home User manual

1
User Manual
ROTOBED®Home

2
Content
1. Introduction and general information……………………………………….. 3
2. Before commissioning………………………..………………………………… 4
2.1 Reception………………………………………………………………..………… 4
2.2Placement…………………………………………………………………………. 4
3. Commissioning………………………………………………………………….. 5
3.1 Mounting of mattress.………..…………………………………………………… 5
3.2 Mounting of side rails………….…………………………………………………. 5
3.3 Remote control……..…………………………………………………………….. 6
3.4 Operating RotoBed®Home……………………………………………………… 7
3.5 Important documents and video material…………………………………………. 9
4. Intended use……………………..………..…………………………………….. 9
4.1 Purposes and standards………………………………………………………… 9
4.2 Maximum load……………………………………………………………. ……… 9
5. Security……………..…………………………………………………………….. 10
5.1 Security during use….……………………………………….……………..……. 10
5.2 General instructions…………………………………………………………… … 10
5.3 Children……..………………………………………………………………….….. 11
5.4 Use of accessories…………………………………………………………….….. 11
5.5 Lifting pole………………………………………………………………….……… 11
5.6 Mattresses…………………………………………………………………….……. 12
5.7 Electricity safety……………………………………………………………….…… 12
6. Cleaning…………………………………………………………………..….……... 12
6.1 Manual cleaning……………………………………………………………….…… 12
6.2 Cleaning in washing system………………………………………………………. 13
7. Service and maintainance……………………………………………………… 13
8. Warranty……………………………………………………………………………. 14
9. Life expectancy………………………………………………………………….... 15
10. Disposal……………………………………………………………………...…….. 15
11. Technical info…………………………………………………………………….. 16
12. Troubleshooting…………………………………………………………………. 17
13. Reset motors……………………………………………………….……….…….. 18
14. Guideline for lubrication………………………………………………………… 19
15. Accessories…………………………………………………………………...….. 20
16. Type plate& symbols…………………………………………………………….. 22
17. EC Declaration of conformity………………………………………………….. 23

3
1. Introduction and general information
Thank you for choosing to buy a RotoBed®Home
RotoBed® is a high quality product that will serve you as an aid for many years to come with
proper use and maintenance.
To get the most out of your bed, please read this manual carefully. The same applies to any other
persons, such as carers or relatives who are going to operate the bed.
It is important that anyone who is to service or clean the RotoBed®Home is aware of the safety
section. This is especially true if at any time there are children in the immediate vicinity of the bed.
Please note the warranty section, including what to comply with in order to maintain the warranty.
This manual may contain inaccuracies or typographical errors. The information contained herein is
regularly updated, and changes to product care and others may be enrolled in later editions.
Changes and improvements without notice may occur. If you have any questions, you are always
welcome to contact us.
Please contact us if your needs change after the purchase of the bed. The RotoBed® Home can be
upgrated to a RotoBed®Free with height adjustment. We also have a wide range of accessories
that can help make the RotoBed®Home an even better tool for you.
We hope that your new RotoBed®Home will give you increased comfort, mobility and quality of life.
1.1 lWhat RotoBed® Home can do for you
People who are struggling to get into or out of the bed themselves can, with a RotoBed®Home,
become selfreliant and manage entry and exit without physical effort.
By holding down a single key on the remote control, the bed is raised to comfort position and
rotated perpendicular to the room. This facilitates both exit and potential transition to a wheel-
chair or stand up hoist. The movement takes less than a minute.
RotoBed®Home helps the user maintain mobility and supports the user's standing function.
The bed makes the user more selfreliant and reduces the trouble and pain of getting up and
going to bed.
The patient surface is 4-sectioned, and entry and exit is possible on both sides of the bed.
In addition to the rotary function, RotoBed®Home features electrical adjustment of backrest
and leg parts.

4
2. Before commissioning
2.1. lReception
Damage that has occurred during transport must be notified immediately upon delivery.
Check that all ordered parts are free of defects at reception. The bed must not be used if
there are errors or defects that may cause risks to people.
Contact the manufacturer or local representative if the product is damaged, if it has
other visible signs of defects or if the bed is not working.
2.2 lPlacement
Select the correct location for the bed:
Provide sufficient distance to wall / furniture, taking into account the movements of the bed.
Place the bed near a wall outlet to prevent free cables / fall risk.
Illustration of the bed's dimensions and
space requirements.
Be aware that it is possible to individually
store the inclination of the backrest. The
chosen inclination will affect the required
distance to the wall during rotation.
Standard delivery setting is a 45°
inclination and a distance to the wall of
at least 11 cm. Inclination can be stored
at any point between 35° and 55°.

5
3. Commissioning
3.1 l
Mounting of the mattress
RotoBed®Home comes with a mattress consisting of a main part and a foot part.
The main mattress has 5 buttons on the back.
First place the three lower buttons in the grooves at the bottom of the bed.
Slide the mattress towards the foot end.
Now press the two buttons in the centre of the mattress into the corresponding holes
in the middle of the bed.
Similarly, the foot mattress has two buttons, which fit into the two round holes in the bed.
The mattress is best protected by using the semi-impermeable cover in stretchable
incontinence foil.
3.2 lMounting of side rails
RotoBed®Home can be delivered with side rails made of metal or oak veneer.
Regardless of material the side rails are mounted and removed in the same way:
Press the small fitting underneath while lifting the bed rail.
The side rails can simply be put back into place and will automatically lock.
NB! The side rails should only be mounted or not mounted. Do not leave them upright and
loose. This may cause squeeze risk and damage to the bed during rotation.

6
3.3 lRemote control
RotoBed®Home can rotate either left or right depending on your preference. Therefore,
the remote control can be connected to both the right and left sides of the bed. When the
remote control is not in use, you can place it on the side rail.
Backrest up
Backrest down
Leg-part up
Leg-part down
PROGRAM:
CHAIR POSITION
PROGRAM:
SLEEPING POSITION

7
3.4 l Operating RotoBed®Home
Before use:
Hold down the Chair Position key until the bed stops in exit position.
As standard, RotoBed®Home is set to run to an oblique exit position
to facilitate transfer to wheelchair or walker.
If you wish a perpendicular exit, do as follows with the bed still inside
the bed frame:
Hold the program keys Chair Position and Sleeping Position for 5
seconds until a beep sounds.
From now on, the bed will automatically move to a perpendicular exit.
In order to go back to angled exit, repeat the procedure.
NB:
For maximum comfort during rotation, see
Individual storing of backrest inclination next page.

8
Entry:
Get seated as close to the backrest as possible for the best
comfort. Hold down the Sleeping Position key until the bed
is rotated and horizontal. Now the RotoBed®Home works
like an normal bed with adjustable leg-part and backrest.
Exit:
Hold down the Chair Position key until the bed stops in an
exit position. To facilitate exit you can, by means of the
remote control, move the backrest the last bit forward.
Individual storing of backrest inclination:
Move the backrest to desired inclination during entry and
exit. Press both backrest keys simultaneously for 5 seconds
until a beep sounds. In the future this will be the inclination
when using Chair Position and Sleeping Position.
Standard delivery inclination is 45º.
Individual storing of backrest inclination:
Move the backrest to desired inclination during entry and
exit. Press both backrest keys simultaneously for 10 seconds
until a beep sounds. In the future this will be the inclination
when using Chair Position and Sleeping Position.
Standard delivery inclination is 45º. Inclination can be stored
at any point between 35º and 55º.
Individual storing of backrest inclination:
Move the backrest to desired inclination during entry and
exit. Press both backrest keys simultaneously for 5 seconds
until a beep sounds. In the future this will be the inclination
when using Chair Position and Sleeping Position.

9
3.5 lImportant documents
The following documents have been prepared for this bed:
User Manual
This instruction manual describes all aspects of the bed.
This applies to both safety and cleaning, commissioning and instructions in
relation to the location and use of the bed. General information about service,
warranty and maintenance can also be found in the User Manual.
Quick-guide
The Quick Guide is a brief, focused instruction on how to help the user enter and
exit the bed using the remote control. The guide is intended for users, staff and
relatives. It is recommended that the guide is available at the bed for daily use.
Video material
Video instructions for service and assembly can be found on
www.rotobed.com/downloads
4. Intended use
4.1 l Purposes and standards
RotoBed®Home is designed to help users with pain/physical difficulties. It facilitates entry
and exit for the user and reduces the workload for relatives in connection with transfers.
RotoBed®Home is developed for users in private homes.
RotoBed®Home is CE-Marked according to the Machinery Directive (EU) 2006/42/EF.
4.2 Maximum load
RotoBed®Home may be used only respecting the following limitations::
Rated load: 225 kg. User weight: max. 190 kg.
(user weight + other things).

10
5. Security
5.1 lSecurity during use
Always read the user manual before use and follow the instructions.
RotoBed®Home must not be used rotating anything other than the user to which the bed is
fitted.
The bed should only be used by a user who has sufficient mobility and cognitive
understanding to utilize the bed's functions and avoid accidents.
The rotary function must not be used with more than one person in the bed.
When the bed's functions are operated, the moving parts of the rotary bed constitute a
squeezing hazard.
When adjusting the bed's positions, all objects and persons, especially children, must
be kept clear of the moving parts of the bed.
The entire body of the user must be within the patient surface.
Be aware that the bedding does not get caught in the moving parts of the bed while
adjusting the bed's positions.
The connecting cable must be free of the rotation mechanism and capable of moving
while adjusting the bed positions.
5.2 l General instructions
The RotoBed®Home engines meet all relevant standards and norms. Electrically
adjustable beds use extremely powerful engines. To prevent overload or damage to the
bed, it is important to follow the regulations when operating the engines.
The remote control must always be available and located correctly. Keep in mind that the
remote control does not clamp between the moving parts of the bed, as this may cause the
keys to be activated without intention.

11
5.3 lChildren
RotoBed® wishes to draw users attention to the potential dangers of children who play in and
around the bed. Children are naturally curious. They find beds with moving parts exciting, but due to
the powerful engines, the bed is absolutely not suitable as a toy. In case of improper use there is a
risk of getting squeezed. The following must therefore be emphasized:
Do not let children play with the bed and its remote control / functions.
Inform visitors and persons responsible for children about the potential safety risk.
Children who stay close to the bed must be guided and not left alone.
Place the remote control away from curious eyes and hands.
Disconnect any power supply if deemed appropriate.
5.4 l Use of accessories
It is the responsibility of the user to ensure that bed and accessories are assembled and used
according to the manufacturer's instructions.
Do not use third party accessories, side rails or mattresses without the manufacturer's approval.
Violation of this may pose a safety hazard.
5.5 l Lifting pole
RotoBed®Home can be delivered with a lifting pole to be mounted on the right or left side of the bed's
headend. The lifting pole's grip is provided with a roller belt so that the height can be adjusted to the
individual user.
Maximum load of lifting pole: 75 kg.
Do not use the lifting pole outside the bed frame as this may constitute a rollover risk.
Before use and for continuous maintenance, check the lifting pole for damage to the roller belt's
stitches and cracks in the grip.

12
5.6 l Mattresses
RotoBed®Home can be delivered with different types of quality foam mattresses with pressure ulcer
prevention in stages 2 and 3, as well as a high protection mattress with documented pressure ulcer
prevention and treatment in all 4 stages.
The mattress will consist of two parts; a main part and a foot part.
Remember to attach the mattress to the bed as per the regulations (see assembly instructions
page 5). Failure to fasten can cause the mattress to not follow the bed's movements or slide off
the bed. This will pose a security risk to the user.
5.7 l Electricity safety
The electrical equipment of the bed must not be changed.
Regularly check the power cable for damage. In case of obvious damage, turn off the power
supply and seek professional advice.
Before use and service / maintenance, check all electrical wiring, power supply and connection
for cracks or other visible damage.
6. Cleaning
6.1 l Manual cleaning
Metal parts
All surfaces can be cleaned with a soft damp cloth and mild detergent.
Wipe with a cloth moistened with clean water and dry again.
Make sure all the bed's parts are dry before putting the mattress back onto the bed.
Wooden parts
Use cleaning and care products designed for wood furniture.
Make sure all the bed's parts are dry before putting the mattress back onto the bed.

13
6.2 l Cleaning in washing system
RotoBed®Home is classified IPX6W and can be cleaned in a washing system.
When cleaning in washing systems, follow the RotoBed® washing instructions. You will find these at
www.rotobed.com under downloads.
7. Service and maintenance
RotoBed®Home does not require much maintenance, but it will minimize any problems if you keep the
bed clean and follow the instructions for use and cleaning.
1. Control of electrical parts
Check all power cables for damage.
Check the power plug condition.
Check the remote control functions.
2. Control of mechanical parts
Check all frame components for wear, damage and corrosion.
Check that backrest and leg parts are running smoothly and at full power using the remote
control.
Check that the rotary engine is running smoothly and for full power.
Check that all joints (nuts, screws, etc.) are tightened.
Check the lifting pole (if mounted).
Apply grease to all moving parts and remove excess grease.
4. Control of side rails
Check the function of the side rails
Check the side rail grips for damage.

14
8. Warranty
RotoBed®Home is a high quality product which is to ensure many years of trouble-free use.
If the bed is purchased as new, there is a three year guarantee on the bed. This warranty covers
spare parts and repair of defects in the product during this period, unless otherwise stated in the
sales agreement.
The warranty covers problems due to defects in the design or production of the bed - however, only if
the bed has been used in accordance with these instructions. Faults and defects that arise during the
warranty period must be reported immediately to the dealer or manufacturer, who will determine if
the bed is to be repaired, replaced or discarded.
Incorrect use of the bed, abuse and accidental damage is not covered by the warranty, and in that
case there will be a fee for the repair. A minor breach of warranty will not affect the continuation of
the warranty. Under certain circumstances, actions that cause fundamental damage to the bed will
lead to invalidation of the warranty for the rest of the warranty period.
Events that are not covered by the warranty include:
Damage caused by overload or improper use of the bed.
Damage caused by washing or cleaning where instructions are not followed.
Damage caused by missing or improper maintenance.
Accidental damage to the remote control, for example, if it is dropped in liquid or
run over by a wheelchair.
Damage to cables, for example if they are caught in the moving parts of the bed.
Damage to mechanical or electrical parts under the bed due to incorrect use of
lifting or hoisting equipment.
Damage to mattress and upholstery for any reason.
Damage to the wall or adjoining furniture due to improper placement of the bed.
Damage to the electrical outlet for any reason.
Damage caused by electrical parts being opened or used improperly.
The bed is designed to carry a defined maximum weight. Maximum user weight and label load
must not be exceeded. The above are examples, and the list is therefore not readable as all-
encompassing.

15
Wood is a natural product and undergoes a natural aging process. Over time, environmental
impacts such as humidity, heat and UV radiation will cause changes in the surface of the wood.
Changes caused by natural aging are not covered by the warranty.
9. Life expectancy
RotoBed® Home has an expected lifetime of minimum 10 years depending on maintenance /
treatment.
The use of beds that are not in good quality- and safety condition can lead to dangerous
situations.
Use, cleaning, maintenance and service according to the manufacturer's regulations will affect
the lifetime of the bed. It will also extend the lifetime when wear parts are replaced as required
and according to the manufacturer's instructions.
10. Disposal
RotoBed® focuses on recycling and environmentally sound production. Disposal of beds or bed
parts must take into account the environment and comply with national legislation. Local authorities
can provide information on how and where used equipment can be delivered.
The bed can be divided into waste fractions metal, plastic, electronics and cables.
When disposing the bed can be divided into the following material groups:
PRODUCT
MATERIAL
HANDLING
RotoBed®Home
Electronics, wires and cables
Metal
Laminate
Plastic
Tree
Textiles
Electronics waste
Recycling
Burnable
Burnable
Burnable
Burnable
Mattress
Plastic
Cold foam
Textile
Burnable
Burnable
Burnable
Upholstery for side rails
Textile
Burnable
Lifting Pole
Metal
Plastic
Recykling
Burnable

16
11. Technical info
A= 0-86° lB= 0-20° lC= 0-74° lD= 0-16,7°
WEIGHT AND LOAD
User weight max
190 kg
Accessories max
35 kg
Headboard
22 kg
Foootboard
20 kg
Frame
104 kg
Total weight
146 kg
PATIENT SURFACE (4-sectioned with electric setting)
Length (mattress)
205-225 cm
Width (mattress)
85/100 cm
Height of patient surface, min/max
From floor to patient surface 32-52 cm
BED (outer measure)
Length
228 cm
Width
94 cm
Free space over floor
> 15 cm

17
12. Troubleshooting
SYMPTOM
POSSIBLE CAUSE
HANDLING
1
The bed does not respond to the remote control.
The remote control is not
connected to the bed.
Plug the remote control into
the control box.
2
The remote is connected, but the bed does not
respond.
Is defect
Replace remote control and
associated cable.
The engine of the bed is not
adjusted and does not work
for that reason.
Check that all sockets are
properly installed and that
the power is connected to
the bed. Use the remote
control reset function, see
"Reset motors".
May occur after service or if
engine plug has been
removed.
Use the remote control reset
function, see "Reset
motors".
3
Only some of the electrical features respond when
pressing the remote control
Cable is plugged into the
wrong control box
Plug cable in the correct
control box
Motor is damaged
Change defect part
Control or remote control
is defect
Change defect part
Control box is defect
Change defect part
4
The bed says a strange sound when set with the
remote control.
Motor is damaged
Change defect part
Wires or parts are clamped
If the cord or bed parts are
damaged, replace the part.
Send bed for service.
The bed needs lubiration
Follow the guide page 19
5
The motors often have to be reset.
Check that all cables are
well connected
Check if any of the
connected devices such as
actuators, remote controls,
cables, etc. are defect.
Control box is defect
6
The bed smells warm or runs irregularly.
The bed is overloaded.
Send the bed for service.

18
13. Reset of motors
If the bed is not working as expected, it can be reset via the remote control.
NB! In the event of disconnection of the motor cable, it may be necessary to reset the system.
NB! If the bed is equipped with bed rails, these must be removed before resetting.
Simultaneously press both sides of the leg-part key on the remote
control (leg-part up + leg-part down)
There is now a constant beep sound for about 10 seconds.
Continue to hold the keys even after the beep stops.
The bed will now move all engines to their outermost positions. This
may take up to one and a half minutes.
The bed is now reset and ready for use.
If the need for reset is repeated, the bed must be serviced.

19
14. Guideline for lubricating the bed
Move the backrest to an upright position. Make sure to fix it before you start removing bolts, otherwise it will fall down.
All the moving parts (A) where the frame is connected must be sprayed with Teflon. Very important: do not tighten
the nuts/bolt (A) too much; they must be a little bit loose. Repeat the procedure on the other side of the bed.
1) Remove the upper clips
2) Remove the bolt
3) Apply grease (see below right)
4) Insert the bolt and clips again
5) Follow the same procedure
with the bolt at the other end of
the motor.
(A)
(A)
(A)

20
Raise the leg-part to a horizontal position, find the point where the bolt at the foot-motor is loose.
Now follow the same procedure as for lubricating the backrest:
1) Remove the upper clips. 2) Remove the bolt. 3) Apply grease. 4) Reinsert bolt and clips.
5) Follow the same procedure with the bolt at the other end of the motor.
Gas spring: Remove the bolt and nuts. Apply grease to the bolt and reinsert it. Follow the same procedure at the other
end of the gas spring –and on the gas spring on the other side. Very important: do not tighten the outer nut (B) too
much; it must still be a little bit loose.
Spray some Teflon into the U-Profile (under the leg-part) on both sides.
Use following grease or similar type: OKS 470 –White Universal High-Performance Grease
Description: Universal grease with white solid lubricants and NSF H2 approval - Lubrication of normal-load friction, rolling and
pivoting bearings - Lubrication of moving parts at fine-mechanical devices –Waterproof.
Use following Teflon Spray or similar type: Würth HHS 2000 Lubricating Oil 500ml (spray) Description: High-
pressure resistant- Extraordinarily tear-resistant lubricating film with outstanding noise and vibration damping properties - High creep
capacity - Excellent lubricating properties with close tolerances - Reliably protects against corrosion - Active adhesive effective. No
throwing off of the lubricant with turning and rotating parts - Splash and saltwater-resistant, withstands weak acids and alkaline
solutions - Contains no silicone, resin or acid.
(B)
(B)
Other manuals for Home
1
Table of contents
Other RotoBed Indoor Furnishing manuals
Popular Indoor Furnishing manuals by other brands

Argos
Argos ASTON 152/5546 Assembly instructions

Next
Next Corsica Console Bookcase Assembly instructions

Martha Stewart Living
Martha Stewart Living LYNN 48 Assembly instructions

Trasman
Trasman 5010 MSPACE Assembly manual

MANCHESTER WOOD
MANCHESTER WOOD AMERICANA 48 BENCH Assembly instructions

Multistore
Multistore EXC-750H2 Assembly instruction