Royal Home Massage bathtub Series User manual

Installation and Operation Manual

1
Before operation, please read this manual
carefully, so as to use this product properly.
Preface
We heartily thank you for choosing our massage tub series product. This product, belonging to the new-generation healthy
and leisure category, has been meticulously made with carefully selected materials, with the features of simplicity, elegance,
comfort, practicality high quality and affordability, etc. It will bring you infinite relaxation and delight of shower.
Before unpacking, please check the parts and make sure no parts are lacking according to the drawing, and please carefully
analyze the product structure and installation positions of the parts. Install according to the instructions and pay attention to the
following:
1) We will provide you with high quality warranty services for the product you have chosen: To protect your interest, please
carefully fill the product warranty card. If you need other services, please contact your dealer or directly contact our
company.
2) During storage of this product, please do not place it upside down or obliquely; do not pile up things on the product; do
not storage it together with formic acid, formaldehyde organic solvents. When carrying it, please handle with care and avoid
heavy load, strong vibration and collision.
3) The warranty does no cover product damage or failure caused by improper installation by user or caused by operation
not in accordance with operation processes shown in the product manual.
4) To achieve optimal performance of this product, we suggest using original parts from our company.
5) After unpacking, the glass should be carried vertically by two persons. To prevent glass surface scratch, please mat the
glass surface with soft material before installation.
Before installation
1. Before installing this product, please make sure that water supply, power supply and sewage pipes are ready at the
installation area. For specific installation locations, please see the technical parameter diagram of this product. This product's
working water pressure is 0.1 ~0.6Mpa; water supply adopts G1/2 threaded cold/hot water connecters; please see the
electric parameter plate for the electric parameters. This product requires the installation area to reserve 1 1/2 sewage
pipeline.
2. The products of our company adopt integrated assembly technology, with different components assembled before
leaving factory. Before unpacking, please check that the product model, specs and configuration meet your order.
3. After unpacking, please carefully check if the product parts are complete and not damaged during shipping. If any
problem is found, please contact the dealer of our company.
4. Before installation, please prepare these tools: Phillips screwdriver, slotted screwdriver, level bar and wrench.
Installation tools
Level bar
Rubber hammer
Caulk Gun
Cross point
screwdriver
Drill&Assorted
Drill Bits
Pencil
Measuring tap
Claw hammer
Allen key
A drill of 6mm
diameter

2
Safety precautions
1. Installation, testing, repair or replacement of this product must be done by professional or person sent by dealer.
2. Power supply facilities connected to this product must meet national standards, and all power supply parameters must tally
with this product (See electric parameters chart). Forbid lengthen the power cable.
3. This product must be powered by a RCD with residual current not exceeding 30mA. Besides, for power supply of this
product, an all-pole disconnection power switch meeting requirements must be installed. And regularly confirm that all these
devices are effective.
4. The equipotential (the yellow and green wire) connector of this product must be permanently connected with external
equipotential connector.
5. During installation and application, forbid cutting any of the connecting wires of the product. Do not disassemble the electric
cabinet and control panel. Otherwise, our company will not take any responsibility for product failure, leakage or electric shock
resulted.
6. Acetone, ammonia water, gasoline and such organic solvent and strong acidic chemicals will dissolve and corrode different
parts of this product, so please avoid contacting such substances during installation and application.
7. The product installation area must be well ventilated, dry and without corrosive gassy. If not used for a long time, please cut
off power supply.
8. Before connecting cold and hot water pipes, please discharge the water that has been staying inside the pipes, so as to
prevent damaging water control equipment.
9. Children using this product must be accompanied by an adult. The old and patient should use this product carefully.
Cleaning and maintenance
1. For daily cleaning of the massage bathtub, please use common liquid detergent and soft cloth, but do not use detergent
containing ketone or ammonia water; do not use disinfectant containing formaldehyde for disinfection.
2. Surface stains can be cleaned by rubbing with toothpaste and soft cloth.
3. For slight surface scratches or cigarette burns, please burnish with 2000# levigation sandpaper and then do polishing.
4. For stains on electroplated parts, please wipe slightly with soft lint. Do not use coarse cloth or solvents like thinner.
5. Often clean water suction device to prevent blocking.
6. Irregularly check for inconvenience in use caused by pipe crack or folding.
7. Often check electrical wire, switches, plugs for fall-off or damage, so as to repair in-time.
8. To lengthen service life of the product, please note that continuous use should not exceed 3 hours.
Basic technical parameters
1.
Supply voltage: AC190V--240V 50-60Hz
9.
Electromagnetic valve: AC12V 8W
2.
Water pump power: AC220V 750W
10.
Music power: <15W
3.
Air pump power: AC220V 750W
11.
Frequency range: FM88--108MHz
4.
Heater power: AC220V 1500W
12.
S/N radio: >45dB
5.
Dielectric strength: 1500V 1Min
13.
Water proof scale: IPX4
6.
Electricity leakage:<0.25mA
7.
Ozone: AC 12W 8W
8.
Water lamp voltage: AC12V 20W

Diagram of massage tub
Installation method
Installation steps
This product adopts standard parts, so please refer to product water and electrical diagrams and electrical
parameter plate when installation.
1. Decide product installation position
Place the tub at the installation area, adjust the bottom nuts for leveling. (See the diagrams below).
2. Connect sewage pipeline
Insert the 1 1/2"plastic pipe into the sewage pipeline, then seal with tape or glass adhesive. Do not fold the pipe, so as not to
influence draining effect. (See the diagrams below).
Wall drain type connection diagram Floor drain type connection diagram
3. Connecting cold water pipe and hot water pipe
The cold water pipe and hot water pipe are high-pressure reticulated pipes. Please follow the connector indication in
connection. (Note: One valve for cold water pipe and one valve for hot water pipe must be installed.)
4. Power connection
Securely connect the power cables to the all-pole
disconnection RCD, and pay attention to waterproofing.
User must securely connect the yellow and green ground
wire (equipotential wire) with the ground wire of the house.
5. Checking, cleaning and testing
After completing all above steps, please clean the tub, open
the drainer, and use clean water for washing. Then check
for normal operation of all functions, then fill the tub with
water and make sure there is no water leakage in all
pipelines.
3
Main devices
①Massage Jet
⑦Water Force Adjustment:
②Function Changer Switch
⑧Water Suction Device
③Cold Water Control
⑨Pillow
④Hot Water Control
⑩Drainer
⑤Multifunctional Shower Head
⑪Draining switch
⑥Air Switch
⑫Waterfall
Adjustment nut
Stainless steel rack
Equipotential terminal
Yellow and green ground
wire (equipotential wire)

4
Waterfall installation
Tub surface
Hexagon positioning screw '
Waterproofing mat Waterfall nut
Waterfall inlet pipe sign Connecting function
switching single handle
Gooseneck waterfall installation diagram
Screw positioning hole
Slotted positioning screw Tub surface
Waterproofing mat Waterfall nut
Waterfall inlet pipe sign Connecting function
switching single handle
Bent pipe waterfall installation diagram
Screw positioning hole
Slotted positioning screw Tub surface
Waterproofing mat Waterfall nut
Waterfall inlet pipe sign Connecting function
switching single handle
Square pipe waterfall installation diagram
Screw positioning hole
Slotted positioning screw Tub surface
Waterproofing mat Waterfall nut
Waterfall inlet Connecting function
pipe sign switching single handle
Conical type waterfall installation diagram
Deluxe 5-piece kit configuration
The deluxe 5-piece kit includes waterfall, shower head, cold/hot water adjustment single handle (water flow switch),
waterfall/shower head switching single handle and drainer.
1. Shower head: Hand-held shower head, can be lifted according to requirement.
2. Waterfall: Main water inlet.
3. Temperature adjustment: Controls water temperature through adjusting proportion of incoming cold and hot water.
4. Function switching: Can switch between shower head/waterfall/water flow closed
Water pipeline working principle of deluxe 5-piece kit configuration
Caution: When connecting cold and hot water pipes, please note that the blue color pipe is for cold water, and the
red color pipe is for cold water and do not reverse. The hot water pipe end connecting temperature adjustment has
a one-way valve to prevent cold water entering hot water pipe due to cold water pressure higher than hot water
pressure.
Please check the configuration of the product purchased when referring to water pipeline diagram.
Water pipe diagram for round-head deluxe 5-piece kit Water pipe diagram for three-jaw deluxe 5-piece kit
Shower head Waterfall Temperature adjustment
Function switching
Tub surface
Waterfall Shower head
Function switching Temperature adjustment
Tub surface
Cold water in (Blue)
Hot water in (Red)
Cold water in (Blue)
Hot water in (Red)

5
Water pipe diagram for waistdrum deluxe 5-piece kit
Waterfall Shower head
Function switching Temperature adjustment
Tub surface
Water pipe diagram for conical deluxe 5-piece kit
Waterfall Shower head
Function switching Temperature adjustment
Tub surface
Water pipe diagram for square-shaped deluxe 5-piece kit
Waterfall Shower head
Function switching Temperature adjustment
Tub surface
Pipeline working principle
Caution: When connecting cold and hot water pipes, please note that the blue color pipe is for cold water, and the
red color pipe is for hot water and do not reverse. The hot water pipe end connecting temperature adjustment has
a one-way valve to prevent cold water entering hot water pipe due to cold water pressure higher than hot water
pressure.
Please check the configuration of the product purchased when referring to water pipeline diagram.
Water pipe diagram for round-head 5-piece kit Water pipe diagram for three-jaw kit
Shower head
Waterfall Temperature adjustment
Function switching
Tub surface
Water pipe diagram for waistdrum kit
Shower head
Waterfall Temperature adjustment
Function switching
Tub surface
Waterfall Shower head
Function switching Temperature adjustment
Tub surface
Water pipe diagram for square-shaped kit
Waterfall Shower head
Temperature adjustment
Function switching
Tub surface
Cold water in (Blue)
Hot water in (Red)
Cold water in (Blue)
Hot water in (Red)
Cold water in (Blue)
Hot water in (Red)
Cold water in (Blue)
Hot water in (Red)
Cold water in (Blue)
Hot water in (Red)
Cold water in (Blue)
Hot water in (Red)
Cold water in (Blue)
Hot water in (Red)

6
Water pipe diagram for conical kit
Shower head
Waterfall Function switching Temperature adjustment
Tub surface
Installation drawing
Radio antenna
Cold water in (Blue)
Hot water in (Red)

7
System wiring drawing
Control panel function description
Warning:
Qualified technician is requiried to install the system. The leakage protection switch should be installed in the right
place. Or manufacture will not be responsible for user because of it.
Please make sure all wirings install well before use it
If any technical information changed we will not inform

8
Remote control use
Main switch ON/OFF
(Telephone dial-up 0) Heater
(Telephone dial-up 2) Water inflow or outflow
(Telephone dial-up 1) Temperature set
(Telephone dial-up 4) O3
(Telephone dial-up 5) Underwater lamp
(Telephone dial-up 7) Massage pump
(Telephone dial-up 8) Air bubble
Channel down
VOL-
Telephone
FM/CD exchange
Memory (Telephone dial-up 3)
TUN+ (Telephone dial-up 6)
TUN- (Telephone dial-up 9)
VOL+
Channel up
Operation instructions
1. Massage section:
1) The operation of system be on or off: get through the leakage plug, then press the main switch . the LCD will show
"YOU ARE WELCOME" when it works. At the same time, also in the left corner of it will show the present water temperature
(10°C-50°C), but system will show the setting is 40°C. AII can be worked as user's need. Press main switch" t then
close down all system.
2) Water inflow or outflow function: press: Water inflow control valve starts, LCD will show after 5 mins it will be
closed by automatically. (all use by user's need)
3) Massage function: This function controlled by water level, if lack of water will be show. And water pump will not
work. Till the normal water level, then will be disappeared, and massage pump will be started also last 60 mins
then closed by automatically.
4) Heater functions: 1.: lf only start the water pump, press then the heater works. The heater will be closed when
water pump closed.
Heater is controlled by temperature setting, when water temperature is lower than the temperature your setting, it works

9
normal, will be shown. When water temperature higher or the same as the temperature your setting, it will be non-work
(constant temperature). Will be shown. During constant temperature, water temperature must be 2°C lower than the
temperature your setting then can be work again.
Temperature set: Press press or can adjust the temperature.
The range of temperature setting: 20°C-45°C
The range of temperature show: 10°C-50°C
Warning of excess temperature: When water temperature higher than 50°C, LCD shows "HEAT"
5) Air bubble function: Press air bubble can start or close it. When start LCD will show dynamic digital display .
After 60mins will be closed by automatically.
6) Underwater lamp function: Underwater lamp will start when start water pump.
(Display switch) Also can press to start or close it. When starts the LCD will show dynamic digital display
Press for 2 seconds, LCD shows LOCK and , means lock panel, or means unlock.
7) O3function: press can start or close it. When starts, LCD shows O3and lasts 30 mins then closed by automatically.
8) Telephone function: When start the panel or during FM or AUX, if calling need answer to, FM or AUX will be closed, the
speaker ring, and LCD shows , at the time, can press, , the telephone key shows then can get through calling. After
calling then press Telephone key again, the FM or AUX will be recovered, LCD shows FM or AUX. If need call to anybody, just
need press Telephone key, then press the numbers shows in LCD is OK.
2. Radio section:
1) Put the radio antenna in the right place, press FM radio switch , LCD will show frequency of radio, the volume DB will be
increased from 0 to 08 DB., Speaker has little sounds.
2) Press shows , then press or choose channels. If press it over 2 seconds, frequency will up or
down by automatically, till get channels. If no good signal or bad condition, we advise choose channels by hands. If get good
channel please press memory key . lt will show in , means can keep that channel in this key, the most memory
channels are 20.
(Before keep channel memory must choose channle.or press just up or down).
or to choose channels press KEY.
The temperature you setting shows

10
3) AUTO Channel:
Press for 2 seconds then be in AUTO channel selection model, LCD shows . Then system will search
channels (87.5-108Mhz), LCD will show the frequency you are searching. When search channel, LCD shows 1CH,
means system searchs the first channel, also memroy it. Then system will search channels by automatically, till 20 Channels or
all frequency. (The quantity of channels are according to your local frequency, this system can save 20 channels at most).
Finished searching, system will come back and listen to the first channel.
Relisten step: Press memory key to choose channels
4) CD: Connect the AUX input wire and Electric cabinet wire, press make sure in AUX, then press VOL+ or VOL- to
choose vol.
5) VOL adjust: Press or can adjust, LCD will show DB
3. OFF
Press can turn off all function, LCD shows GOOD BYE OFF. AII system is off, if not use for long time, please cut off
the power.
Electrical installation
1. The electrical facilities should meet national safety standards. Power voltage and frequency should tally with parameters on
product electrical plate. Special attention should be paid to install leakage protection switch and verify that the grounding is
effective.
2. Power supply connection to massage tub should be permanent fixed-type wiring with 3 cores, and with each core exceeding
1 mm2(i.e. 3 x 1 mm2) in sectional area. Power cable crossing wall should have protective galvanized flexible tube till power
socket.
3. Connect the massage tub ground wire with house electrical ground wire and verify effectiveness.
4. Power must connect to special power wire, and make sure to shut off power supply after every use.
Water supply facilities
1. This product's water supply pressure: 0.2MPa-0.4MPa; cold/hot water connector: G1/2"
2. The water supply point of the massage tub should be set at the place easy to be hidden by the tub, and should be connected
with hose to the massage tub faucet. Water pipe diameter shall be decided by user.
3. Water supply pipe must have independent valve, and should be closed after every use.
This manual suits for next models
1
Table of contents
Popular Bathtub manuals by other brands

American Standard
American Standard Savona Corner Whirlpool 2902.028 parts list

MCBATH
MCBATH BLOCK installation manual

Artweger
Artweger TWINLINE TL1 Series Assembly instructions

DURAVIT
DURAVIT Vero Air 760418 Mounting instructions

RAVAK
RAVAK New Day 150x150 Assembly

Kohler
Kohler Jacob Delafon E6D034-00 installation guide

Kohler
Kohler K-702-H2 Homeowner's guide

Jacuzzi
Jacuzzi THE ESSENTIALS Series manual

Renaissance Baths
Renaissance Baths EXCEL 300 installation instructions

MAAX
MAAX 106839 installation instructions

Jacuzzi
Jacuzzi ARGA FREE-STANDING Installation

Porcelanosa
Porcelanosa Noken CITY USA 160234 N710001174 manual