1241044-E-01-161006
Plastic injection presses, automatic bread making ovens, nylon bag machines,
shrink packing machines, furniture presses, industrial ovens, textile machines,
ironing presses and other temperature control applications.
Application areas
• 96 x 96mm, 1/4 DIN Format.
• Digital display shows process temperature or setpoint.
• On-Off or time proportional control.
• Fe-Const thermocouple.
• Output relay de-energizes on sensor failure.
• Easy setting procedure.
• CE marked.
Dimensions
Flush
mounting
adaptor
Rubber
packing
Panel
Panel cut-out
Note:
1/2
Panel thickness
should be
max. 10mm.
105mm
99mm
90.5mm
90.5mm
For removing mounting clamps: Push out the flush-mounting clamp in direction 1 as shown in the figure above. Then, pull out the clamp in
direction 2. If there is no 60mm free space at back side of the device, it would be difficult to remove it from
the panel.
200
250
400
300
350
100
150
50
0
°C
OUT
SET
Temperature setting
knob
Control output state LED
(Light is on when control output is energized) Set key
Temperature display
96mm
99mm
1
OUT
200
250
150 °C
300100
35050
4000
SET
Technical Specifications
Supply 230V AC +10% -20%, 50/60Hz
Power consumption Max. 5VA
2.5mm² screw-terminal connection
Wiring
HOUSING
Housing type Suitable for flush-panel mounting
Dimensions W96xH96xD50mm
Weight Approx. 250g (after packing)
Enclosure material Self extinguishing plastics
CONTROL
Control type Single-setpoint control
On-Off / time proportional (optional)
Control algorithm
A/D converter 10 bits
Proportional band
Control period
Hysteresis
2% (for time proportional control)
10 second (for time proportional control)
4°C (for On-Off control)
OUTPUT
Control output Relay : 250V AC, 2A (for resistive load), NO+NC or 12V DC 20mA logic output
Mechanical 30.000.000 operation; electrical 300.000 operation
Life expectancy for relay
0 ... 400°C
1°C
For adjustment 4%, for display 0,5% (of full scale) or 1 digit± ± ±
3 digits, 7.6mm, 7 segment red LED
Scale
Sensitivity
Accuracy
Display
Data retention
EMC
Safety requirements
EN 61326-1: 2013
EEPROM (at least 10 years)
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
ENVIRONMENTAL CONDITIONS
Height Max. 2000m
80 up to 31°C decreasing linearly 50 at 40°C. % %
Ambient/storage temperature
Max. relative humidity
0 ... +50°C/-25... +70°C
Rated pollution degree According to EN 60529 Front panel : IP60
Rear panel : IP20
Do not use the device in locations subject to corrosive and flammable gases.
While cleaning the device, solvents (thinner, brnzine, acid etc.) or corrosive materials must not be used.
ELECTRICAL CHARACTERISTICS
Depth
50mm
14mm
57mm
2
EN
Please read this document carefully before using this product. The guarantee will be invalidated if the device is
damaged by not following instructions detailed in the manual. The company shall not be responsible for any damage
or losses however caused,
which
may be
experienced
as a
result of the
installation
or use
of
this product.
Instruction Manual
RS Pro Analog Thermostat with Digital Display
Stock Number: 124-1044
FOR MORE INFORMATION VISIT THIS SITE
http://www.rs-components.com/index.html
124-1044 230V AC 1