manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ruckus Wireless
  6. •
  7. Rack & Stand
  8. •
  9. Ruckus Wireless SmartCell Gateway 200 User manual

Ruckus Wireless SmartCell Gateway 200 User manual

Other manuals for SmartCell Gateway 200

8

This manual suits for next models

1

Other Ruckus Wireless Rack & Stand manuals

Ruckus Wireless 902-0108-0000 User manual

Ruckus Wireless

Ruckus Wireless 902-0108-0000 User manual

Ruckus Wireless 902-0178-0002 Installation instructions manual

Ruckus Wireless

Ruckus Wireless 902-0178-0002 Installation instructions manual

Ruckus Wireless T811-CM User manual

Ruckus Wireless

Ruckus Wireless T811-CM User manual

Popular Rack & Stand manuals by other brands

Dynex DX-MP3MT Quick setup guide

Dynex

Dynex DX-MP3MT Quick setup guide

Konig & Meyer 24185 manual

Konig & Meyer

Konig & Meyer 24185 manual

ECG LD 326501 instruction manual

ECG

ECG LD 326501 instruction manual

Philips SB7S19S/00 quick start guide

Philips

Philips SB7S19S/00 quick start guide

Woodline KIT-250 lb instructions

Woodline

Woodline KIT-250 lb instructions

ricoo S1222 installation instructions

ricoo

ricoo S1222 installation instructions

Kanto P301 user manual

Kanto

Kanto P301 user manual

VidaBox VB MNT FFS2 installation guide

VidaBox

VidaBox VB MNT FFS2 installation guide

PROEL PLWIN60C user manual

PROEL

PROEL PLWIN60C user manual

AllMounts PLB-43S instruction manual

AllMounts

AllMounts PLB-43S instruction manual

VMP VH-001 instruction sheet

VMP

VMP VH-001 instruction sheet

Nederman SYSTEM 920/400 instruction manual

Nederman

Nederman SYSTEM 920/400 instruction manual

Glasdon ORBIS POST MOUNTING KIT installation guide

Glasdon

Glasdon ORBIS POST MOUNTING KIT installation guide

Songmics LGR105 manual

Songmics

Songmics LGR105 manual

Grape GM401 user manual

Grape

Grape GM401 user manual

FourStarGroup 11225296 manual

FourStarGroup

FourStarGroup 11225296 manual

CHIEF FLR100 installation instructions

CHIEF

CHIEF FLR100 installation instructions

FEC XDCAM EX PMW-EX30 manual

FEC

FEC XDCAM EX PMW-EX30 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Copyright © 2013 Ruckus Wireless, Inc.
Published June 2013, Part Number 800-70456-001 Rev D Page 1 of 2
ZoneDirector™5000 and
SmartCell Gateway™200
Rack Mount Installation Guide
This Rack Mount Installation Guide provides step-by-step
instructions on how to install the Ruckus Wireless ZoneDirector
5000 or SmartCell Gateway 200 (SCG) into a server rack. Both
ZoneDirector 5000 and SCG are standard 2U form factor
designed for mounting in a standard EIA 19” server rack.
BEFORE YOU BEGIN
Before deploying your Ruckus Wireless product, verify that all
items listed in “Package Contents” below are included in the
package. If any item is damaged or missing, notify your
authorized Ruckus Wireless sales representative. Also, ensure
that you have prepared the required hardware and tools.
THIS GUIDE IN OTHER LANGUAGES
请从以下网站获得该指南的简体中文版
https://support.ruckuswireless.com.
Vous trouverez la version française de ce guide à l'adresse suivante
https://support.ruckuswireless.com.
こ の ガ イ ド の⽇本語版は https://support.ruckuswireless.com
でご覧く ださい。
이가이드의 한국어 버전은 웹사이트
(https://support.ruckuswireless.com)에서 확인하시기 바랍니다 .
Veja a versão em português (Brasil) deste guia em
https://support.ruckuswireless.com.
Puede ver la versión en español (América Latina) de esta guía en
https://support.ruckuswireless.com.
REQUIRED HARDWARE AND TOOLS
• 3/8-inch hex driver or wrench
• Phillips (crosshead) screwdriver, #1 and #2 bits
• Anti-static wrist strap and conductive foam pad
(recommended)
PACKAGE CONTENTS
A complete rack mount installation kit includes all of the items
listed below:
NOTE: This kit includes two sets of 8-32 x 1/2" screws. One set
of eight has a larger screw head size than the second set of
eight. Use the set of 8-32 x 1/2" screws that best fits the rack in
which you are installing the rail kit.
• Outer rail slide assembly (see A in Figure 1)
• Inner rail slide assembly (see B in Figure 1)
• Plastic bag #1, which contains the following items:
- Four hex head shoulder screws (see A in Figure 4)
- Two rack mounting ears (see A in Figure 7)
- Two #10-32 x 3/8” screws (see B in Figure 7)
• Plastic bag #2, which contains the following items:
- Outer slide rail screws, 8 #8-32 x 1/2 (see D in Figure 1)
- Inner slide rail screws, 8 #6-32 x 1/4 (see D in Figure 1)
- Rack screws, 2 #8-32 x 3/4 (see D in Figure 1)
•ThisRack Mount Installation Guide
Figure 1: Rail assemblies and rail screws
STEP 1: SEPARATE THE SLIDE RAILS INTO THE INNER
AND OUTER PARTS
1Extend the inner rail (see 1 in Figure 2) until it locks.
2Press down the spring safety lock (see 2 in Figure 2) to
release the inner rail.
3Remove the inner rail from the rail assembly (see 3 in Figure
2).
Figure 2: Separating the slide rails
STEP 2: INSTALL THE OUTER RAIL SLIDES TO THE
RACK POSTS
NOTE: The two rail assemblies that are included are NOT
interchangeable. Each assembly needs to be installed into the
rack by its orientation (right or left) when standing in front of the
rack. The right rail assembly is identified with a BLUE sticker and
the left rail assembly is identified with a GREEN sticker.
Attach the outer rail slides to the rack posts using two #8-32 x
1/2 screws at the front posts and two #8-32 x 1/2 screws at the
rear posts.
Figure 3: Installing the outer rails
Copyright © 2013 Ruckus Wireless, Inc.
Published June 2013, Part Number 800-70456-001 Rev D Page 2 of 2
STEP 3: FASTEN THE SHOULDER SCREWS TO THE
SERVER
Fasten two hex head shoulder screws on each side of the server.
Figure 4: Fastening the shoulder screws
STEP 4: INSTALL THE INNER RAILS ON THE SERVER
Install the inner rails onto the hex head shoulder screws, and
then slide the inner rails forward.
Figure 5: Installing the inner rails
STEP 5: FASTEN THE INNER RAILS TO THE SERVER
Secure the inner rails with one #6-32 x 1/4 screw for each rail.
Figure 6: Securing the inner rails
STEP 6: ATTACH THE MOUNTING EARS TO THE RAIL
ASSEMBLY
Attach the rack mounting ears to each side of the server using
the #10-32 x 3/8 screws.
Figure 7: Attaching the mounting ears
STEP 7: SLIDE THE RAIL ASSEMBLY INTO THE OUTER
RAILS AND SECURE TO THE RACK
1Align the inner rails (attached to the server chassis) with the
outer rail assemblies (attached to the rack).
2Engage the matching rails, and then slide the server chassis
into the rack until the two spring safety locks snap into
position.
3Press down the two spring safety locks (one on each side).
See 1 in Figure 8.
4Slide the server chassis all the way into the rack. See 2 in
Figure 8.
5Use the rack screws (#8-32 x 3/4) to secure the chassis and
rack handles into the rack. See 3 in Figure 8.
Figure 8: Securing the server to the rack
Congratulations! You have completed mounting the
ZoneDirector 5000 or SCG into your server rack.