Ruijie RG-DEMUX Series Installation and operating manual

Ruijie RG-DEMUX/MUX Series
Multiplexers and Demultiplexers
Hardware Installation and Reference Guide
Document Version: V1.2
Date: 2022.04.14
Copyright © 2022 Ruijie Networks

Copyright Statement
Copyright © 2023 Ruijie Networks
Ruijie Networks reserves all copyrights of this document.
Any reproduction, extraction, backup, modification, transmission, translation or commercial use of this
document or any portion of this document, in any form or by any means, without the prior written consent of
Ruijie Networks is prohibited.
Trademarks and are owned by Ruijie Networks.
All other trademarks or registered trademarks mentioned in this document are owned by their respective
owners.
Disclaimer
The products, services or features you purchase are subject to commercial contracts and terms. Some or all of
the products, services or features described in this document may not be within the scope of your purchase or
use. Unless otherwise agreed in the contract, Ruijie Networks does not make any express or implied statement
or guarantee for the content of this document.
Due to product version upgrades or other reasons, the content of this document will be updated from time to
time. Ruijie Networks reserves the right to modify the content of the document without any notice or prompt.
This manual is for reference only. Ruijie Networks endeavors to ensure content accuracy and will not shoulder
any responsibility for losses and damages caused due to content omissions, inaccuracies or errors.

1
Preface
Audience
This document is intended for:
Network engineers
Technical support and servicing engineers
Network administrators
Technical Support
Ruijie Networks Website: http://www.ruijie.com.cn
Ruijie Networks Services and Support Website: http://www.ruijie.com.cn/fw/
Ruijie Networks 7*24h Ruijie Intelligent Technical Assistant http://ocs.ruijie.com.cn
Ruijie Networks 7*24h Technical Service Hotline: 4008-111-000
Ruijie Networks After-sales Service Tool - Ruijie Cloud Service: http://www.ruijie.com.cn/special/fw/tool/xryf/
Ruijie Networks Technical Support and Feedback Email: 400811[email protected]
Ruijie Cloud Service APP Ruijie Services WeChat Official Account
Conventions
1. Signs
The signs used in this document are described as below:
Danger
An alert that calls attention to safety instruction that if not understood or followed when operating the device can
result in physical injury.
Warning
An alert that calls attention to important rules and information that if not understood or followed can result in
data loss or equipment.
Caution
An alert that calls attention to essential information that if not understood or followed can result in function
failure or performance.
Note
An alert that contains additional or supplementary information that if not understood or followed will not lead to
serious consequences.

Hardware Installation and Reference Guide Overview
2
Specification
An alert that contains a description of product or version support.
2. Note
Some information in this guide (such as product model, description, port type, and software interface) is for
reference only and the actual product may vary.
This guide describes the installation procedure, troubleshooting procedure, technical specifications, and optical
module specifications and usage guidelines. It is intended for users who have some experience in installing and
maintaining network hardware and assumes that the user is familiar with relevant terminology and concepts.

Hardware Installation and Reference Guide Overview
3
1 Overview
The RG-DEMUX/MUX series demultiplexers and multiplexers are passive devices for optical switching
released by Ruijie Networks for simplified optical Ethernet scenarios.
Boasting CWDM technology and 16-channel standard wavelengths ranging from 1271nm to 1571nm in 20nm
increments, this series, when used along with Ruijie Simplified Optical Ethernet solutions, can extend 10G/1G
optical fibers to each room and meet customer requirements for collapsing the distribution switch, achieving
passive distribution nodes, and reducing the configuration and O&M workloads of active distribution nodes.
Moreover, in some reconstruction scenarios, expansion of port services also becomes possible with existing
optical fiber resources, thus solving the problem of insufficient optical fiber resources.
Table 1-1 Specifications of RG-DEMUX/MUX Series
Model
Name
Number of
CWDM
16-channel
demultiplexe
r groups
Install
ation
locatio
n
Maximu
m
number
of ports
support
ed
Dimension
s (W × D ×
H)
RG-DEMUX-24LC/LC
Expansion
module for the
24-port core
demultiplexer
3 groups
Core
side
24
216.4 mm *
207 mm * 33
mm
RG-DEMUX(C)-24LC/LC
24-port
demultiplexer,
with chassis
and one
reserved
expansion slot
3 groups
Core
side
24
297.6 mm *
438.5 mm *
40.2 mm
RG-DEMUX-48LC/LC
48-port
demultiplexer
6 groups
Core
side
48
297.6 mm *
438.5 mm *
40.2 mm
RG-MUX-24LC/LC
Expansion
module for the
24-port
multiplexer
3 groups
Buildin
g side
24
216.4 mm *
207 mm * 33
mm
RG-MUX(C)-24LC/LC
24-port
multiplexer,
with chassis
and one
3 groups
Buildin
g side
24
210.2 mm *
440 mm *
39.8 mm

Hardware Installation and Reference Guide Overview
4
reserved
expansion slot
RG-MUX-48LC/LC
48-port
multiplexer
3 groups
Buildin
g side
48
210.2 mm *
440 mm *
39.8 mm
Caution
The multiplexer in this series should be used along with a Ruijie CWDM transceiver!
1.2 RG-DEMUX(C)-24LC/LC
1.2.1 Specifications
Table 1-2 Specifications
Model
RG-DEMUX(C)-24LC/LC
Description
24-port demultiplexer, with 3 multiplexing ports (number of fiber trunk cables
connected)
Center wavelength
1271 nm to 1571 nm (CWDM)
Channel spacing
20 nm
Channel bandwidth
±6.5 nm
Insertion loss
≤ 4 dB (demultiplexer and multiplexer)
Return loss
> 45 dB
Polarization
dependent loss
> 0.3 dB
Adjacent channel
isolation
> 25 dB
Non-adjacent channel
isolation
> 35 dB
Connector
LC/UPC
Operating
Temperature
-40°C to 85°C (WDM products are not pressure sensitive and have no
requirement for altitude)
Storage Temperature
-40°C to 85°C
Operating Humidity
10% to 90% RH
Storage Humidity
5% to 90% RH
Standards
GR-1221-Core and GR-1209-Core

Hardware Installation and Reference Guide Overview
5
Weight
3.05 kg (net weight)
1.2.2 Appearance
Integrating 3 groups of CWDM 16-channel passive wavelength division demultiplexers,
RG-DEMUX(C)-24LC/LC supports 24 access ports, and has 3 multiplexing ports. The peer end should be used
together with a multiplexer (RG-MUX(C)-24LC/LC or RG-MUX-48LC/LC). RG-DEMUX(C)-24LC/LC reserves
one expansion slot.
Figure 1-2 RG-DEMUX(C)-24LC/LC
Installation location: RG-S7800C series chassis or 19 RU rack on the core side, wall-mounting also supported.
1. Front Panel
The device contains one expansion module. The enlarged view of the expansion module on the front panel is
shown below:
Note
●Multiplexing Port A - correspond to the first group of 16 channels
M
E
S
e
x
M

Hardware Installation and Reference Guide Overview
6
●Multiplexing Port B - correspond to the second group of 16 channels
●Multiplexing Port C - correspond to the third group of 16 channels
●Demultiplexing Port 1 should be connected to Core 1 CWDM transceiver
●Demultiplexing Port 2 should be connected to Core 2 CWDM transceiver
●Demultiplexing Port 3 should be connected to Core 3 CWDM transceiver
●Demultiplexing Port 4 should be connected to Core 4 CWDM transceiver
●Demultiplexing Port 5 should be connected to Core 5 CWDM transceiver
●Demultiplexing Port 6 should be connected to Core 6 CWDM transceiver
●Demultiplexing Port 7 should be connected to Core 7 CWDM transceiver
●Demultiplexing Port 8 should be connected to Core 8 CWDM transceiver
2. Back Panel
1.3 RG-DEMUX-48LC/LC
1.3.1 Specifications
Table 1-3 Specifications
Model
RG-DEMUX-48LC/LC
Description
48-port demultiplexer, with 6 multiplexing ports (number of fiber trunk cables
connected)
Center wavelength
1271 nm to 1571 nm (CWDM)

Hardware Installation and Reference Guide Overview
7
Channel spacing
20 nm
Channel bandwidth
±6.5 nm
Insertion loss
≤4 dB (demultiplexer and multiplexer)
Return loss
> 45 dB
Polarization
dependent loss
> 0.3 dB
Adjacent channel
isolation
> 25 dB
Non-adjacent channel
isolation
> 35 dB
Connector
LC/UPC
Operating
Temperature
-40°C to 85°C (WDM products are not pressure sensitive and have no
requirement for altitude)
Storage Temperature
-40°C to 85°C
Operating Humidity
10% to 90% RH
Storage Humidity
5% to 90% RH
Standards
GR-1221-Core and GR-1209-Core
Weight
3.49 kg (net weight)
1.3.2 Appearance
Integrating 6 groups of CWDM 16-channel passive wavelength division demultiplexers, RG-DEMUX-48LC/LC
supports 48 access ports, and has 6 multiplexing ports. The peer end should be used together with a
multiplexer (RG-MUX(C)-24LC/LC or RG-MUX-48LC/LC).
Figure 1-3 RG-DEMUX-48LC/LC

Hardware Installation and Reference Guide Overview
8
Installation location: RG-S7800C series chassis or 19 RU rack on the core side, wall-mounting also supported.
1. Front Panel
The device contains two expansion modules. The enlarged view of the expansion module on the front panel is
shown below:
Note
●Multiplexing Port A - correspond to the first group of 16 channels
●Multiplexing Port B - correspond to the second group of 16 channels
●Multiplexing Port C - correspond to the third group of 16 channels
●Demultiplexing Port 1 should be connected to Core 1 CWDM transceiver
●Demultiplexing Port 2 should be connected to Core 2 CWDM transceiver
●Demultiplexing Port 3 should be connected to Core 3 CWDM transceiver
●Demultiplexing Port 4 should be connected to Core 4 CWDM transceiver
●Demultiplexing Port 5 should be connected to Core 5 CWDM transceiver
●Demultiplexing Port 6 should be connected to Core 6 CWDM transceiver
●Demultiplexing Port 7 should be connected to Core 7 CWDM transceiver
●Demultiplexing Port 8 should be connected to Core 8 CWDM transceiver
2. Back Panel
This manual suits for next models
7
Table of contents
Popular Multiplexer manuals by other brands

ADTRAN
ADTRAN Frameport 768 Specifications

Elo TouchSystems
Elo TouchSystems E247 Operation manual

Paradyne
Paradyne Hotwire 8786 installation instructions

RFL Electronics
RFL Electronics 9508D UCC instruction manual

Miranda
Miranda AMX-101i Guide to installation and operation

ShipModul
ShipModul MiniPlex-AIX NMEA-0183 manual











