Racal Instruments 1260-50C User manual

-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
•
Critical
and
expedited
services
•
Leasing
/
Rentals/
Demos
• In
stock/
Ready-to-ship
•
!TAR-certified
secure
asset
solutions
Expert
team
ITrust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Find the Astronics / EADS / Racal 1260-50D at our website: Click HERE

1260 VXI
SWITCHING CARD
1260-50C/D
200MHz
MULTIPLEXER MODULE
PUBLICATION NO. 980673-028
RACAL INSTRUMENTS
Racal Instruments, Inc.
4 Goodyear St., Irvine, CA 92618-2002
Tel: (800) RACAL-ATE, (800) 722-2528, (949) 859-8999; FAX: (949) 859-7139
Racal Instruments, Ltd.
480 Bath Road, Slough, Berkshire, SL1 6BE, United Kingdom
Tel: +44 (0) 1628 604455; FAX: +44 (0) 1628 662017
Racal Systems Electronique S.A.
18 Avenue Dutartre, 78150 LeChesnay, France
Tel: +33 (1) 3923 2222; FAX: +33 (1) 3923 2225
Racal Systems Elettronica s.r.l.
Strada 2-Palazzo C4, 20090 Milanofiori Assago, Milan, Italy
Tel: +39 (0)2 5750 1796; FAX +39 (0)2 5750 1828
Racal Elektronik System GmbH.
Technologiepark Bergisch Gladbach, Friedrich-Ebert-Strasse, D-51429 Bergisch Gladbach, Germany
Tel.: +49 2204 8442 00; FAX: +49 2204 8442 19
Racal Instruments, Ltd.
Unit 5, 25F., Mega Trade Center, No 1, Mei Wan Road, Tsuen Wan, Hong Kong, PRC
Tel: +852 2405 5500, FAX: +852 2416 4335
http://www.racalinstruments.com
PUBLICATION DATE: FEBRUARY 18, 2003
Copyright 2001 by Racal Instruments, Inc. Printed in the United States of America. All rights reserved.
This book or parts thereof may not be reproduced in any form without written permission of the publisher.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Thank you for purchasing this Racal Instruments product.
For this product, or any other Racal Instruments product that incorporates software drivers, you
may access our web site to verify and/or download the latest driver versions. The web address for
driver downloads is:
http://www.racalinstruments.com/downloads
You will be asked to register one time only to gain access to the driver and product manual
downloads sections. At registration a cookie will be placed on your computer if you choose to
accept it. This is done to facilitate your use of these sections on future visits. You may refuse to accept the
cookie and still have complete access to the software driver database but will have to re-register every time
you visit. This cookie is for ease of use only and no information is gathered for, sold, or reported to, any third
party organization.
If you have any questions about software driver downloads or our privacy policy, please contact
us at
info@racalinstruments.com.
WARRANTY STATEMENT
All Racal Instruments, Inc. products are designed and manufactured to exacting standards and in
full conformance to Racal’s ISO 9001 procedures.
This warranty does not apply to defects resulting from any modification(s) of any product or part
without Racal’s express written consent, or misuse of any product or part. The warranty also does
not apply to fuses, software, non-rechargeable batteries, damage from battery leakage, or
problems arising from normal wear, such as mechanical relay life, or failure to follow instructions.
This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty
of merchantability or fitness for a particular use. The remedies provided herein are buyer’s sole and
exclusive remedies.
For the specific terms of your standard warranty, or optional extended warranty or service
agreement, contact your Racal customer service advisor. Please have the following information
available to facilitate service.
1. Product serial number
2. Product model number
3. Your company and contact information
You may contact your customer service advisor by:
E-Mail: Helpdesk@racalinstruments.com
Telephone: +1 800 722 3262 (USA)
+44(0) 8706 080134 (UK)
+852 2405 5500 (Hong Kong)
Fax: +1 949 859 7309 (USA)
+44(0) 1628 662017 (UK)
+852 2416 4335 (Hong Kong)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

RETURN of PRODUCT
Authorization is required from Racal Instruments before you send us your product for service or
calibration. Call your nearest Racal Instruments support facility. A list is located on the last page of
this manual. If you are unsure where to call, contact Racal Instruments, Inc. Customer Support
Department in Irvine, California, USA at 1-800-722-3262 or 1-949-859-8999 or via fax at 1-949-
859-7139. We can be reached at: helpdesk@racalinstruments.com.
PROPRIETARY NOTICE
This document and the technical data herein disclosed, are proprietary to Racal Instruments, and
shall not, without express written permission of Racal Instruments, be used, in whole or in part to
solicit quotations from a competitive source or used for manufacture by anyone other than Racal
Instruments. The information herein has been developed at private expense, and may only be used
for operation and maintenance reference purposes or for purposes of engineering evaluation and
incorporation into technical specifications and other documents which specify procurement of
products from Racal Instruments.
DISCLAIMER
Buyer acknowledges and agrees that it is responsible for the operation of the goods purchased
and should ensure that they are used properly and in accordance with this handbook and any
other instructions provided by Seller. RII products are not specifically designed, manufactured or
intended to be used as parts, assemblies or components in planning, construction, maintenance or
operation of a nuclear facility, or in life support or safety critical applications in which the failure of
the RII product could create a situation where personal injury or death could occur. Should Buyer
purchase RII product for such unintended application, Buyer shall indemnify and hold RII, its
officers, employees, subsidiaries, affiliates and distributors harmless against all claims arising out
of a claim for personal injury or death associated with such unintended use.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

FOR YOUR SAFETY
Before undertaking any troubleshooting, maintenance or exploratory procedure, read carefully the
WARNINGS and CAUTION notices.
This equipment contains voltage hazardous to human life and safety, and is capable of inflicting
personal injury.
If this instrument is to be powered from the AC line (mains) through an autotransformer, ensure
the common connector is connected to the neutral (earth pole) of the power supply.
Before operating the unit, ensure the conductor (green wire) is connected to the ground (earth)
conductor of the power outlet. Do not use a two-conductor extension cord or a three-prong/two-
prong adapter. This will defeat the protective feature of the third conductor in the power cord.
Maintenance and calibration procedures sometimes call for operation of the unit with power
applied and protective covers removed. Read the procedures and heed warnings to avoid “live”
circuit points.
Before operating this instrument:
1. Ensure the instrument is configured to operate on the voltage at the power source. See
Installation Section.
2. Ensure the proper fuse is in place for the power source to operate.
3. Ensure all other devices connected to or in proximity to this instrument are properly grounded or
connected to the protective third-wire earth ground.
If the instrument:
- fails to operate satisfactorily
- shows visible damage
- has been stored under unfavorable conditions
- has sustained stress
Do not operate until performance is checked by qualified personnel.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

This page was left intentionally blank.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
i
Table of Contents
Chapter 1
INTRODUCTION ........................................................................................................................ 1-1
1260-50C/D 200MHz Multiplexer Module ................................................................................ 1-1
Specifications .......................................................................................................................... 1-3
Ordering Information ............................................................................................................... 1-6
Chapter 2
INSTALLATION INSTRUCTIONS............................................................................................... 2-1
Unpacking and Inspection ....................................................................................................... 2-1
Reshipment Instructions.......................................................................................................... 2-1
Option 01 Installation............................................................................................................... 2-1
Module Installation................................................................................................................... 2-1
Chapter 3
MODULE SPECIFIC SYNTAX .................................................................................................... 3-1
1260-50C/D Module Specific Syntax ....................................................................................... 3-1
Syntax.................................................................................................................................. 3-1
OPEN............................................................................................................................... 3-1
CLOSE............................................................................................................................. 3-2
PSETUP........................................................................................................................... 3-2
PDATAOUT...................................................................................................................... 3-2
Chapter 4
DRAWINGS................................................................................................................................ 4-1
Chapter 5
PARTS LIST ............................................................................................................................... 5-1
Chapter 6
OPTIONAL HARNESS ASSEMBLIES ........................................................................................ 6-1
Chapter 7
PRODUCT SUPPORT ................................................................................................................ 7-1
Product Support ...................................................................................................................... 7-1
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
ii
Reshipment Instructions...........................................................................................................7-1
Support Offices ........................................................................................................................7-2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
iii
List of Figures
Figure 1-1, 1260-50C/D .............................................................................................................. 1-1
Figure 1-2, 1260-50C/D Functional Diagram............................................................................... 1-2
Figure 1-3, 1260-50C/D Front Panel and J200-J203 Connector Pin Configuration .................... 1-5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
iv
This page was left intentionally blank.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
Introduction 1-1
Chapter 1
INTRODUCTION
1260-50C/D
200MHz
Multiplexer
Module
The 1260-50C/D provides eight/sixteen 1 x 4 multiplexers (refer
to the Functional Diagram Figure 1-2). Relays CHI9, 29,..., 159
provide for the connections between the adjacent 1 x 4 groups
under software control. Thus, the 1260-50C/D module can be
configured as multiplexers up to 1 x 39/1 x 79 size. The 200
MHz bandwidth is guaranteed for all possible multiplexer sizes.
The only restriction is the groups not needed for a connection
between any two channels have to be disconnected to achieve
200 MHz bandwidth.
Figure 1-1, 1260-50C/D
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
Introduction 1-2
J200
K5 CH04
K4 CH03
K2 CH02
K1 CH01
K3 CH00
E
D
C
B
A
K6
CH19
K11 CH14
K10 CH13
K8 CH12
K7 CH11
K9 CH10
L
K
J
H
F
K12
CH29
K17 CH24
K16 CH23
K14 CH22
K13 CH21
K15 CH20
S
R
P
N
M
K18
CH39
K23 CH34
K22 CH33
K20 CH32
K19 CH31
K21 CH30
X
W
V
U
T
K24
CH49
J201
K29 CH44
K28 CH43
K26 CH42
K25 CH41
K3 CH40
E
D
C
B
A
K30
CH59
K44 CH54
K45 CH53
K43 CH52
K47 CH51
K46 CH50
L
K
J
H
F
K48
CH69
K41 CH64
K39 CH63
K37 CH62
K38 CH61
K40 CH60
S
R
P
N
M
K42
CH79
K35 CH74
K33 CH73
K31 CH72
K32 CH71
K34 CH70
X
W
V
U
T
27
J202
K53 CH84
K51 CH83
K49 CH82
K50 CH81
K52 CH80
E
D
C
B
A
K54
CH99
K59 CH94
K57 CH93
K55 CH92
K56 CH91
K58 CH90
L
K
J
H
F
K60
CH109
K65 CH104
K64 CH103
K62 CH102
K61 CH101
K63 CH100
S
R
P
N
M
K66
CH119
K71 CH114
K70 CH113
K68 CH112
K67 CH111
K69 CH110
X
W
V
U
T
K72
CH129
J203
K77 CH124
K76 CH123
K74 CH122
K73 CH121
K3 CH120
E
D
C
B
A
K78
CH139
K83 CH134
K82 CH133
K80 CH132
K79 CH131
K81 CH130
L
K
J
H
F
K80
CH149
K89 CH144
K88 CH143
K86 CH142
K85 CH141
K87 CH140
S
R
P
N
M
K90
CH159
K95 CH154
K94 CH153
K92 CH152
K91 CH151
K93 CH150
X
W
V
U
T
75
1260-50C
1260-50D
K36
CH89
Figure 1-2, 1260-50C/D Functional Diagram
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
Introduction 1-3
Specifications Minimum Option 01 Firmware Revision
User Connector
Housing:
Contact:
Maximum Switchable Voltage
(Signal to Ground)
Maximum Switchable Current Per
Channel
Maximum Carry Current Per Channel
Life Expectancy
Typical at Signal Level <1.0 V, .010 A
DC Performance
Path Resistance
(1X4 Multiplexer)
(1X79 Multiplexer)
AC Performance
Impedance
Bandwidth (-3 dB)
Insertion Loss
(1 x 4 Multiplexer)
Crosstalk Across Groups 50 Ohm
Termination
Isolation Between Channels 50 Ohm
Termination
VSWR (50 Ohm Termination) (1 x 4
Multiplexer)
24.1
Burndy MSD20PM-118
Burndy RMDX60-36D28
for RG316 Coaxial
Cable
200V DC/Peak AC
Resistive Load
0.5A DC/Peak AC
Resistive Load
1A DC/Peak AC
Resistive load
250 x 106
<0.7W
<2.0W
50 Ohm
>200 MHz
<0.70 dB at 100 MHz
10 MHz: <= -40 dB
100 MHz: <= -40 dB
200 MHz: <= -35 dB
10 MHz: <= -40 dB
100 MHz: <= -40 dB
1.3 :1 at 100 MHz
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
Introduction 1-4
Rise Time
(Typical 1 x 4 Multiplexer)
Fall Time
(Typical 1 x 4 Multiplexer)
Propagtion Delay Time
(Typical 1 x 4 Multiplexer)
Switching Time
Cooling Requirements
Airflow
Backpressure
Power Requirements ('pm)
+5 V
+12 V
Weight
1.6 ns
1.6 ns
3 ns
39 ±5mS
4 litres / sec
0.5 mm H20
2.5 A
0.5 A
1.174 Kg (2.59 lbs)
without Option 01
1.315 Kg (2.90 lbs)
with Option 01
Coaxial Cable, Optional
Racal Instruments P/N Length, Feet Insert ion Loss
@200 MHz
VSWR @ 100 MHz
407368-001 2 <.5 dB 1.2:1
407368-003 6 < 1.0 dB 1.2:1
407368-006 12 <2.0 dB 1.2:1
Coaxial cables have been tested to 1GHz, and are available as
an option. Each cable contains a coaxial pin at each end. The
cables are available in 2, 6, and 12 feet, and can be cut by
customers to any length. (Example: The 6-foot cable can be cut
to two 3-foot or one 2-foot and one 4-foot cable.) Coax pins (P/N
602220-900) suitable for RG316 coaxial cable may be purchased
separately. The 1260-50C requires 40, and the 1260-50D
requires 80. To crimp coaxial pins, use crimp tool Hytool M10S-1
from Burndy.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
Introduction 1-5
Figure 1-3, 1260-50C/D Front Panel
and J200-J203 Connector Pin Configuration
A
BC
DF
E
HK
J
LN
M
P
R
S
TV
X
W
U
A
BC
DF
E
HK
J
LN
M
P
R
S
TV
X
W
U
A
B
C
DF
E
HK
J
LN
M
P
R
S
TV
X
W
U
FAIL
Racal
Instruments
1260-50C
J
2
0
0
J
2
0
1
!
!
A
B
C
DF
E
HK
J
LN
M
P
R
S
TV
X
W
U
A
BC
DF
E
HK
J
LN
M
P
R
S
TV
XW
U
A
B
C
DF
E
HK
J
LN
M
P
R
S
TV
X
W
U
A
BC
DF
E
HK
J
LN
M
P
R
S
TV
XW
U
FAIL
Racal
Instruments
1260-50D
J
2
0
2
J
2
0
3
!
!
J
2
0
0
J
2
0
1
!
!
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
Introduction 1-6
Ordering
Information
Model Number Description Part Number
1260-50C 8 1X4 50WMultiplexer 40 Channels 407366-001
1260-50D 16 1X4 50WMultiplexer 80 Channels 407366-002
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
Installation Instructions 2-1
Chapter 2
INSTALLATION INSTRUCTIONS
Unpacking and
Inspection
1. Before unpacking the switching module, check the exterior of
the shipping carton for any signs of damage. All
irregularities should be noted on the shipping bill.
2. Remove the instrument from its carton, preserving the
factory packaging as much as possible.
3. Inspect the switching module for any defect or damage.
Immediately notify the carrier if any damage is apparent.
4. Have a qualified person check the instrument for safety
before use.
Reshipment
Instructions
1. Use the original packing when returning the switching
module to Racal Instruments for calibration or servicing.
The original shipping carton and the instrument’s plastic
foam will provide the necessary support for safe reshipment.
2. If the original packing is unavailable, wrap the switching
module in plastic sheeting and use plastic spray foam to
surround and protect the instrument.
3. Reship in either the original or a new shipping carton.
Option 01
Installation
Installation of the Option 01 to the 1260-50C/D is described in
the Installation section of the 1260 Series VXI Switching Cards
Manual.
Module
Installation
Installation of the 1260-50C/D Switching Module into a VXI
mainframe, including the setting of DIP switches, is described in
the Installation section of the 1260 Series VXI Switching Cards
Manual. The ID byte DIP switch, SW1-5 should be set OFF for
the 1260-50C module and ON for the 1260-50D module.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
Installation Instructions 2-2
This page was left intentionally blank.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
Module Specific Syntax 3-1
Chapter 3
MODULE SPECIFIC SYNTAX
1260-50C/D
Module Specific
Syntax
NOTE
The 1260-50C/D Coaxial switching module is
supported by the Option 01 Operating Systems at
Revision levels 24.1 and above.
The 1260-50C/D RF Multiplexer supports the OPEN, CLOSE,
PSETUP, RESET and PDATAOUT commands.
Syntax The module specific syntax for the 1260-50C/D RF Multiplexer is
as follows:
OPEN OPEN <module address>.<channel>[ ;<module address> . <channel>J
where <module address> is the address.
<channel> is the relay to be closed to connect an input to
the output.
Note that Channels remain closed until opened by an OPEN
command, RESET command, VXI hard or soft reset, or power-
off.
The range of values for <channel> is:
1260-50C: 00-04, 10-14, 19, 20-24, 29, 30-34, 39, 40-44, 49,
50-54, 59, 60-64, 69, 70-74, 79
1260-50D: 00-04, 10-14, 19 20-24, 29, 30-34, 39, 40-44, 49,
50-54, 59, 60-64, 69, 70-74, 79, 80-84, 89, 90-94,
99, 100-104, 109, 110-114, 119, 120-124, 129,
130-134, 139, 140-144, 149, 150-154, 159
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

User Manual 1260-50C/D
Module Specific Syntax 3-2
CLOSE The Module Specific Syntax for the CLOSE command is the
same as for the OPEN command.
PSETUP The PSETUP command causes the specified module setup to be
transmitted to the VXI Controller. The syntax used is:
PSETUP <module address> [ ;<module address>] [;<module address>]
where <module address> is the address.
The responses to the PSETUP command for the 1260-50C/D
multiplexer is as follows:
1260-50C:
<module address>.1260-50C, 8 (1x4) 200 MHz MULTIPLEXER MODULE
<module address>.B BM
<module address>.END
1260-50D:
<module address>.1260-50D, 16 (1X4) 200 MHz MULTIPLEXER MODULE
<module address> .B BM
<module address> .END
PDATAOUT The PDATAOUT command causes the specified module to
transmit the CLOSED state of the relays fitted to the switching
module to the 1260 Controller. The syntax used is:
PDATAOUT <module address>[ <module address>] [;<module address>]
The responses to the PDATAOUT command is as follows:
1260-50C:
<module address>. 1 260-50C 8 (1 x4) 200 MHz MULTIPLEXER MODULE
<module address> .<channel>[,<channel>] [,<channel>]
<module address> END
1260-50D:
<module address>.1260-50D 16 (1x4) 200 MHz MULTIPLEXER
MODULE
<module address>.<channel>[,<channel>] [,<channel>]
<module address>.END
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
This manual suits for next models
1
Table of contents
Other Racal Instruments Multiplexer manuals

Racal Instruments
Racal Instruments 1260-38T User manual

Racal Instruments
Racal Instruments 1260-112 User manual

Racal Instruments
Racal Instruments 1260 VXI User manual

Racal Instruments
Racal Instruments 1260-100X X Series User manual

Racal Instruments
Racal Instruments MULTIPLEXER PLUG-IN 1260-134 User manual

Racal Instruments
Racal Instruments 1260-X133 User manual

Racal Instruments
Racal Instruments 1260-30 Series User manual