Safire SF-VIMOD-CAM-2 User manual

Door Station
Installation Guide

Door Station Installation Guide
i
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol
Description
Danger
Indicates a hazardous situation which, if not avoided, will or could
result in death or serious injury.
Caution
Indicates a potentially hazardous situation which, if not avoided,
could result in equipment damage, data loss, performance
degradation, or unexpected results.
Note
Provides additional information to emphasize or supplement
important points of the main text.

Door Station Installation Guide
ii
Contents
Chapter 1 Appearance.................................................................................................................... 1
Chapter 2 Terminal and Wiring ......................................................................................................3
2.1 Terminal Description......................................................................................................... 3
2.2 Wiring Description ............................................................................................................4
2.2.1 Power Supply Wiring.............................................................................................. 4
2.2.2 Door Lock Wiring.................................................................................................... 5
2.2.3 Door Magnetic Wiring............................................................................................ 6
2.2.4 Exit Button Wiring.................................................................................................. 7
Chapter 3 Installation..................................................................................................................... 8
3.1 Configure Sub Module Address......................................................................................... 8
3.2 One-Module Installation................................................................................................... 9
3.2.1 Surface Mounting................................................................................................... 9
3.2.2 Flush Mounting .................................................................................................... 12
3.3 Two-Module Installation................................................................................................. 17
3.3.1 Two-Module Surface Mounting ........................................................................... 17
3.3.2 Two-Module Flush Mounting............................................................................... 21
3.4 Three-Module Installation ..............................................................................................26
3.4.1 Three-Module Surface Installation....................................................................... 26
3.4.2 Three-Module Flush Mounting............................................................................. 31
3.5 More-Than-Three Module Installation ........................................................................... 35
3.5.1 More-than-Three Module Surface Mounting....................................................... 35
3.5.2 More-Than-Three Module Flush Mounting..........................................................41

Door Station Installation Guide
1
Chapter 1 Appearance
Front and Side Panel
Figure 1-1 Front and Side Panel
Table 1-1 Appearance Description
No.
Description
1
Microphone
2
Low Illumination IR Supplement Light
3
Built-in Camera
4
Loudspeaker
5
Call Button
6
Nametag
7
TAMPER

Door Station Installation Guide
2
Bottom Panel
Figure 1-2 Bottom Panel
Table 1-2 Appearance Description
No.
Description
8
Network Interface
9
Module-connecting Interface (output)
10
Terminals

Door Station Installation Guide
3
Chapter 2 Terminal and Wiring
2.1 Terminal Description
Figure 2-1 Terminals and Interfaces
Table 2-1 Descriptions of Terminals and Interfaces
No.
Interface
Description
A1
NC1
Door Lock Relay Output (NC)
A2
NO1
Door Lock Relay Output (NO)
A3
COM
Common Interface
A4
NC2
Door Lock Relay Output (NC)
A5
NO2
Door Lock Relay Output (NO)
A6
GND
Grounding
A7
12 VDC
Power Supply Output
A8
GND
Grounding
B1
AIN1
For the access of Door Magnetic 2
B2
AIN2
For the access of Door Magnetic 1
B3
AIN3
For the access of Exit Button 1
B4
AIN4
For the access of Exit Button 2
B5
485-
Module-connecting Interface
B6
485+
B7
12 V OUT

Door Station Installation Guide
4
No.
Interface
Description
B8
GND
C
LAN
Power and Network Interface
2.2 Wiring Description
2.2.1 Power Supply Wiring
Caution
Make sure all the related equipment is power-off during the installation.
Wire the devices with power supply cables as picture shown below.
Door station should be connected to CH6 of the video/audio distributor with two-wire cables.
Indoor Station should be connected to any terminal of CH1 to CH5 of the video/audio distributor
with two-wire cables.
Figure 2-2 Wiring Description

Door Station Installation Guide
5
2.2.2 Door Lock Wiring
Figure 2-3 Door Lock Wiring
Note
●Terminal NC1/COM is set as default for accessing magnetic lock/electric bolt; terminal
NO2/COM is set as default for accessing electric strike.
●Lock should be powered by itself. Max. voltage and current for relay is 30V and 1A.

Door Station Installation Guide
6
2.2.3 Door Magnetic Wiring
Figure 2-4 Door Magnetic Wiring
Note
AIN1 and AIN2 are defaulted to connect door magnetic. Door magnetic connected to AIN1 detects
status of the lock that connected to NC1/NO1; Door magnetic connected to AIN2 detects the
status of the lock connected to NC2/NO2.

Door Station Installation Guide
7
2.2.4 Exit Button Wiring
Figure 2-5 Exit Button Wiring
Note
AIN3 and AIN4 are set as default for connecting exit button. Exit button connected to AIN3 opens
the lock connected to NC1/NO1; Exit button connected to AIN4 controls the lock that connected
to NC2/NO2.

Door Station Installation Guide
8
Chapter 3 Installation
Note
●Make sure the device in the package is in good condition and all the assembly parts are
included.
●Make sure the place for surface mounting is flat.
●Make sure all the related equipment is power-off during the installation.
●Tools that you need to prepare for installation:
Drill (ø6), cross screwdriver (PH1*150 mm), and gradienter.
3.1 Configure Sub Module Address
You need to set the sub module address via DIP before installation.
Steps
1. Remove the rubber cover on the sub module rear panel to expose the DIP switch.
Figure 3-1 DIP Switch
2. Set the sub module address according to the DIP rules, and install the rubber cover back.
Note
●Digit 1, 2, 3, 4 are used to coding the sub module address; Digit 5, 6, 7 are reserved; Digit 8 is
a resistance (120Ω) is you set it as on.
●Valid sub module address range is 1 to 8. The No. should be unique for sub modules that
connected to the same main unit.
The sub module address and corresponding switch status as below.

Door Station Installation Guide
9
Table 3-1 Description
Sub Module
Address
Digit 1
Digit 2
Digit 3
Digit 4
1
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
ON
3.2 One-Module Installation
3.2.1 Surface Mounting
Before You Start
Figure 3-2 Mounting Frame

Door Station Installation Guide
10
Note
●The dimension of one module mounting frame is: 117(W)×107(H)×32.7(D) mm.
●The dimensions above are for reference only. The actual size can be slightly different from the
theoretical dimension.
Steps
1. Paste the installation Sticker 1 onto the wall. Make sure the sticker is placed leveled via
measuring with the gradienter.
2. Chisel 4 holes with drill align to the screw holes on the sticker.
Note
●The suggested size of hole is 6 (diameter) × 25 (depth) mm.
●The suggested length of cables left outside is 100 mm.
Figure 3-3 Chisel Screw Hole
3. Remove the stricker and insert the expansion sleeves into the screw holes.

Door Station Installation Guide
11
4. Fix the mounting frame onto the wall with 4 expansion bolts.
Figure 3-4 Fix the Mounting Frame
5. Connect the cables to the corresponding interfaces of the main unit and insert it into the frame.
Figure 3-5 Insert the Main Unit
6. Fix the cover onto the frame.

Door Station Installation Guide
12
Figure 3-6 Fix the Cover
3.2.2 Flush Mounting
Before You Start
Figure 3-7 Front and Side View of the Gang Box

Door Station Installation Guide
13
Figure 3-8 Gang Box
Note
●The dimension of one-module gang box is: 115(W)×134(H)×56(D) mm.
●The dimensions above are for reference only. The actual size can be slightly different from the
theoretical dimension.
Steps
1. Cave the installation hole, and pull the cable out.
Note
●The suggested dimension of installation hole is 118(L)×108(W)×45.5(D) mm.
●The suggested length of cables left outside is 100 mm.

Door Station Installation Guide
14
Figure 3-9 Cave the Installation Hole
2. Remove the plastic sheet in the cable entry.
3. Insert the gang box into the hole and pull out the cables through the cable entry. Mark the
screw holes' position with a marker, and take out the gang box.
Figure 3-10 Mark the Screw Holes
4. Chisel 4 holes with drill align to marks on the wall, and insert the expansion sleeves into the
screw holes.
Note
The suggested size of hole is 6 (diameter) × 45 (depth) mm.
5. Fix the gang box with 4 expansion bolts.

Door Station Installation Guide
15
Figure 3-11 Fix the Gang Box
6. Fill and level up the gap between the gang box and wall with concrete. Remove the 4 mounting
ears with tool after concrete is dry.
Figure 3-12 Remove the Mounting Ears
7. Insert the mounting frame together with the locating plates into the hole, and fix it with 4
expansion bolts.
8. Connect the cables to the corresponding interfaces of the main unit and insert it into the gang
box.

Door Station Installation Guide
16
Figure 3-13 Insert the Main Unit
9. Use the hexagon wrench in the package fix the cover.
Figure 3-14 Fix the Cover

Door Station Installation Guide
17
3.3 Two-Module Installation
3.3.1 Two-Module Surface Mounting
Before You Start
Figure 3-15 Mounting Frame
Note
●The dimension of two-module mounting frame (W × H × D) is: 219 mm × 107 mm × 32.7 mm.
●The dimensions above are for reference only. The actual size can be slightly different from the
theoretical dimension.
Steps
1. Paste the installation Sticker 1 onto the wall. Make sure the sticker is placed horizontally via
measuring with the gradienter.
2. Drill 4 holes according to the screw holes on the sticker. The suggested size of hole is 6
(diameter) × 25 (depth) mm. The suggested length of cables left outside is 270 mm.