manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SAINT-GOBAIN
  6. •
  7. Fan
  8. •
  9. SAINT-GOBAIN CertainTeed RVG55ML User manual

SAINT-GOBAIN CertainTeed RVG55ML User manual

This manual suits for next models

9

Popular Fan manuals by other brands

Minka Group minkaAire Wave F843 instruction manual

Minka Group

Minka Group minkaAire Wave F843 instruction manual

Airflow Adroit DV50 instruction manual

Airflow

Airflow Adroit DV50 instruction manual

Vornado 270 Series owner's guide

Vornado

Vornado 270 Series owner's guide

comfort air TH-10D instruction manual

comfort air

comfort air TH-10D instruction manual

Livoo DOM386 instruction manual

Livoo

Livoo DOM386 instruction manual

Holmes BLIZZARD HAOF-90 owner's guide

Holmes

Holmes BLIZZARD HAOF-90 owner's guide

Taurus GRECO 16 ELEGANCE manual

Taurus

Taurus GRECO 16 ELEGANCE manual

Quorum PINNACLE installation instructions

Quorum

Quorum PINNACLE installation instructions

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Craftmade UH52 installation guide

Craftmade

Craftmade UH52 installation guide

Jocel JVA030658 instruction manual

Jocel

Jocel JVA030658 instruction manual

MIKA MFB1211/GR user manual

MIKA

MIKA MFB1211/GR user manual

Harbor Breeze RLG52NWZ5L manual

Harbor Breeze

Harbor Breeze RLG52NWZ5L manual

Allen + Roth L1405 instruction manual

Allen + Roth

Allen + Roth L1405 instruction manual

ViM KUBAIR F400 ECOWATT Technical manual

ViM

ViM KUBAIR F400 ECOWATT Technical manual

HIDRIA R10R-56LPS-ES50B-04C10 user guide

HIDRIA

HIDRIA R10R-56LPS-ES50B-04C10 user guide

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

Triangle Engineering HEAT BUSTER SPL Series owner's manual

Triangle Engineering

Triangle Engineering HEAT BUSTER SPL Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTALLATION INSTRUCTIONS

www.certainteed.com http://blog.certainteed.com
CertainTeed Corporation
P.O. Box 860
Valley Forge, PA 19482
Professional: 800-233-8990
Consumer: 800-782-8777
© 2015 CertainTeed Corporation, Printed in the U.S.A.
Code No. 20-20-3548
Part #18958
ASK ABOUT ALL OF OUR OTHER CERTAINTEED®PRODUCTS AND SYSTEMS:


INSTALLATION INSTRUCTIONS






Airhawk RVG 55 Ventilación Galvanizada para Techos con Inclinación Posterior está fabricado por Air Vent, Inc.,



Galvanized Slant Back Roof Vent
Aluminum Slant Back Roof Vent
Plastic Slant Back Roof Vent
Ventilación Galvanizada para Techos
con Inclinación Posterior
Tubos de Ventilación Biselados
de Aluminio
Tubos de Ventilación Biselados
de Techo de Plástico
1. Positioning the vents on the roof
Position the vents evenly spaced across the roof, below the ridgeline so that the vents can only be seen from
one side of the house, yet no greater than 2 feet below the ridgeline.
2. Drill the guide hole
Adjust placement of the vents to avoid drilling through any rafters.
Drill a guide hole near the center position of each vent.
3. Outlining the hole
Mark correct diameter for the vent you have selected using the chart below.
4. Cutting the hole in the roof
Using a saber saw, cut and remove all the roof shingles (and deck) inside the diameter circle you have marked.
Next, cut back approximately 1-inch of the SHINGLES ONLY out of the top half of the hole to allow space for placing
and positioning the ange.
5. Positioning the base
Make sure the base ange parallels the ridgeline of the roof. Slip the upper half of the ange under the shingles.
Center the unit over the hole. For the SLP61, the shingles should stop at the midpoint of the ange while still covering the
nails. For all other static roof metal vents, the shingles should lay on top of the ange all the way down to the lower side of
the opening. The ange from this point should rest on top of the shingles. If nail holes are provided in the vent they should
be used for attaching the vent to the roof deck.
6. Securing the base
Attach the ange securely to the roof with at least 8 galvanized roong nails. Nails should be at least 2" long
and should penetrate the vent, shingles and decking. Use a nail in each corner of the ange and along the middle
of each side of the vent. Use caulk to seal around each nail. If ange ribbing is present, vents should be shingled
down to side ange ribbing only.
1. Posicione las aberturas de ventilación en el tejado
Coloque las aberturas de ventilación separadas de forma pareja a lo largo del tejado, debajo de la línea de la
cumbrera de tal forma que las aberturas de ventilación sólo puedan verse desde una parte de la casa, y nunca más
grandes que 2 pies por debajo de la línea de la cumbrera.
2. Perfore el agujero guía
Ajuste la colocación de las aberturas de ventilación para evitar la perforación a través de algún cabio.
Perfore un agujero guía cerca de la posición central de cada abertura de ventilación.
3. Perle el agujero
Marque el diámetro correcto para la abertura de ventilación que usted haya escogido utilizando la gráca de abajo.
4. Corte el agujero en el tejado
Utilizando una sierra sable, corte y saque todas las tejas (y plataforma) dentro del círculo del diámetro que haya
marcado. Después corte aproximadamente 1 pulgada de las TEJAS SOLAMENTE de la mitad superior del agujero
para dejar espacio para posicionar la aleta.
5. Posicionamiento de la base
Asegúrese de que la aleta base esté paralela a la línea de la cumbrera del techo. Deslice la mitad superior de la
aleta por debajo de las tejas. Centre la unidad encima del agujero. Para la SLP61, las tejas deben terminar a la mitad
de la aleta y deben asimismo cubrir los clavos. Para todas las demás ventilaciones metálicas estáticas de tejados, las
tejas se deben colocar por encima de la aleta hacia abajo hasta el lado inferior de la abertura. A partir de este punto,
la aleta deberá descansar en la parte superior de las tejas. Si la ventilación viene provista con agujeros para clavos,
estos deberán usarse para acoplar la ventilación a la supercie del tejado.
6. Sujeción de la base
Sujete bien la aleta al tejado al menos con 8 clavos galvanizados para tejados. Los clavos deberán ser de 2
pulgadas de largo y deberán penetrar la abertura de ventilación, las tejas y la supercie del tejado. Use un clavo
en cada esquina de la aleta y a lo largo del medio de cada lado de la abertura de ventilación. Use masilla para
sellar alrededor de cada clavo. Si la aleta es estriada, las ventilaciones deben escalonarse hacia abajo hasta la
estría lateral de la brida únicamente.
Use the following chart to determine proper size of opening,
based on the model of vents you are installing.
Description Model# Net Free Area Roof Pitches Diameter of Opening
Galvanized Vent RVG55ML 50 sq. inches 3/12 to 12/12 8"
RVG55BL 50 sq. inches 3/12 to 12/12 8"
RVG55BR 50 sq. inches 3/12 to 12/12 8"
RVG55WW 50 sq. inches 3/12 to 12/12 8"
Aluminum Vent SLAGR 50 sq. inches 3/12 to 12/12 8"
SLABL 50 sq. inches 3/12 to 12/12 8"
SLABR 50 sq. inches 3/12 to 12/12 8"
SLAWW 50 sq. inches 3/12 to 12/12 8"
Plastic Vent SLP61BL 61 sq. inches 3/12 to 12/12 9"
SLP61WW 61 sq. inches 3/12 to 12/12 9"
Siga la siguiente gráca para determinar el tamaño apropiado de la abertura,
basándose en el modelo de ventilación que esté instalando.
Descripción N° de modelo Área libre neta Inclinaciones del tejado Diámetro de abertura
Ventilación RVG55ML 50 pulgs2 3/12 a 12/12 8 pulgs.
galvanizada RVG55BL 50 pulgs2 3/12 a 12/12 8 pulgs.
RVG55BR 50 pulgs2 3/12 a 12/12 8 pulgs.
RVG55WW 50 pulgs2 3/12 a 12/12 8 pulgs.
Ventilación SLAGR 50 pulgs2 3/12 a 12/12 8 pulgs.
de aluminio SLABL 50 pulgs2 3/12 a 12/12 8 pulgs.
SLABR 50 pulgs2 3/12 a 12/12 8 pulgs.
SLAWW 50 pulgs2 3/12 a 12/12 8 pulgs.
Ventilación SLP61BL 61 pulgs23/12 a 12/12 9 pulgs.
de plástico SLP61WW 61 pulgs23/12 a 12/12 9 pulgs.
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS
Ventilaciones de escape con dorso inclinado para tejados
