Sakura AXSP-260HA User manual

SWIMMING POOL HEAT PUMP UNIT
Installation for Manual
Model: AXSP-260HA
SAKURA CORPORATION

CONTENTS
1. Preface 1
2. Specifications 2
2.1 Dimensions for Swimming Pool Heat Pump Unit 2
3. Installation and Connection 3
3.1 Installation of System 3
3.2 Swimming Pool Heat Pumps Location 3
3.3 How Close To Your Pool? 4
3.4 Swimming Pool Heat Pumps Plumbing 4
3.5 Swimming Pool Heat Pumps Electrical Wiring 5
3.6 Initial Start-up of the Unit 5
4.INSTRUCTION FOR WIRE CONTROLLER
Temperature Display section:
When checking the temperature, code name displays on the left side and
at the same time the corresponding temperature value displays on right side;
Code name of the temperature
T1 inlet water temperature T2 outlet water temperature
T3 pipe coil temperature T4 ambient temperature
T5,T6- reserved
The setting temperature
The actual temperature
Time Display section:
Timer On icon displays this icon when you have set Timer On function
and flashes when you are setting
Timer Off icon displays this icon when you have set Timer Off function
and flashes when you are setting
Display the time in normal state.
When in timer on/off setting and time adjusting states, the corresponding icon will flash
4.2 Display screen description
This function is activated by 43# data in EEPROM after the unit powers on.
4.3 Auto-restart function
without auto-restart function, the unit will be in stand-by when the power
supplies again. The screen only displays the time. The timer on/off function
is invalid.
If
the unit with auto-restart function, once the unit off the power abnormally,
and then the power supplies again, the unit will run as the previous condition.
If
When any malfunction occurs, the screen will display relating error code.
4.4 Alarms instruction sheet(error code display priority is from E0 to ED)
When any malfunction occurs, the screen will flash the error code.
Error
code Cause
E0
Malfunction and
Protection
Error
code
E9
Communication error
between wire controller
and the unit
( mainboard error )
Wire controller receives
abnormal signal from
mainboard
Cause
Malfunction and
Protection
Fan motor error or
lack water protection Fan motor or water
flow valve error
E1
EA
Wire controller sensor
error
Communication error
between mainboard and
wire controller
(wire controller error)
Mainboard receives
abnormal signal from
wire controller
E2
EB
Wire controller EEPROM
error
Coil sensor error Coil sensor T3 is open
circuit or short circuit
E3
EC
Inlet water temperature
sensor error
Inlet water temperature
sensor T1 is open circuit
or short circuit
High pressure protection Compressor high
pressure switch acts
E4
ED
Outlet water temperature
sensor error
Outlet water temperature
sensor T2 is open circuit
or short circuit
Low pressure protection Compressor low
pressure switch acts
E5 Outside ambient
temperature sensor error
Outside ambient
temperature sensor
T4 is open circuit or
short circuit
E6 prevent frostbite protection
in cooling state
E7 EEPROM error EEPROM is wrong in
read-write
E8 Wrong phase/ absent
phase protection
Power supply phases
don't connect in correct
order or absent some
4. Instruction for wire controller 6
4.1 Keys functions of the Wire Controller 6
4.2 Display screen description 7
4.3 Auto-restart function 7
4.4 Alarms instruction sheet 7
5. Maintenance 8
SAKURA - Total Air Conditioning Solution SAKURA - Total Air Conditioning Solution

4.INSTRUCTION FOR WIRE CONTROLLER
4.1 keys functions of the Wire Controller
TIMER Key: set the desired timer on/off time and adjust the time
Running state(Press TIMER key once) Timer on / hour setting(Press it once again)
Timer on / minute setting (once again) Timer off / hour setting (once again)
Timer off /minute setting (once again) Running state
When in running state, press TIMER key for a long time, enter into time adjusting,
you can adjust the time as follow sequence:
Hour Minute Hour
After time adjusting, press TIMER key for a long time to quit.
SEARCH Key: Search temperature data and error codes;
When in normal running state, press this key, you can check the different
temperature data T1 T2 T3 T4 T1
When any malfunction occurs, press this key to check the error code.
(For example, when there are total three errors(E3,E4,E5)occur,
the controller will display as follow :E3 E4 E5 E3)
MODE Key: Mode transfer
AUTO COOLING HEATING AUTO
MODE
TIME HEAT
SEARCH
ON/OFF
RESET
Auto model
Cooling model
Heating model
Circulating
Water Pump
Defrosting operation
Auxiliary Heater
(reserved)
* Temperature
Display section
LCD screen
* Time Display
section
* Timer key
* Search key
Auxiliary Heater
key (reserved)
Turn on or turn off
the unit
Press this key, the
wired controller
restart
Press these two keys
to set temperature and
adjust time
* Mode key
1.PREFACE
In order to provide our customers with quality, reliability and versatility, this
product has been made to strict production standards. This manual includes
all the necessary information about installation, debugging, discharging and
maintenance. Please read this manual carefully before you open or maintain
the unit. The manufacture of this product will not be held responsible if someone
is injured or the unit is damaged, as a result of improper installation, debugging,
or unnecessary maintenance. It is vital that the instructions within this manual
are adhered to at all times.
The unit must be installed by qualified personnel.
1 Durable
The heat exchanger is made of PVC & titanium tube which can withstand
prolonged exposure to corrosives such as chlorine.
The unit can only be repaired by qualified installer centre personnel or an
authorised dealer.
Maintenance and operation must be carried out according to the recommended
time and frequency, asstated in this manual.
Use genuine standard spare parts only.
Failure to comply with these recommendations will invalidate the warranty.
Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the
temperature constant. The indoor unit can be discretely hidden or semi-hidden
to suit a luxury house.
This type of pump has the following characteristics:
2 Installation flexibility
The unit can be installed outdoors or indoors.
3 Quiet operation
The unit comprises an efficient rotary/scroll compressor and a low noise
fan motor, which guarantees its quiet operation.
4 Advanced controlling
The unit includes micro-computer controlling, allowing all operation
parameters to be set. Operation status can be displayed on the wire
controller. You can also choose remote controlling.
SAKURA - Total Air Conditioning Solution SAKURA - Total Air Conditioning Solution

2.SPECIFICATION
2.1 The dimensions for Swimming Pool Heat Pump Unit
108
1046
286
450
810
810
841
860
Water outlet
( 50)
Water intlet
( 50)
3.INSTALLATION AND CONNECTION
3.5 Swimming Pool Heat Pumps Electrical Wiring
NOTE: although the unit heat exchanger is electrically isolated from the rest of the unit,
it simply prevents the flow of electricity to or from the pool water. Grounding the unit is
still required to protect you against short circuits inside the unit. Bonding is also required.
3.6 Initial startup of the Unit
Note: in order for the unit to heat the pool or spa, the filter pump must be running to
circulate water through the heat exchanger.
Start up procedure - after installation is completed, you should follow these steps:
1. Turn on your filter pump. Check for water leaks and verify flow to and from the pool.
2. Turn on the electrical power supply to the unit, then press the key ON/OFF of wire controller,
it should start in several seconds.
3. After running a few minutes make sure the air leaving the top(side) of the unit is cooler
(between 5-10 ).
4. With the unit operation turn the filter pump off. The unit should also turn off automatically.
5. Allow the unit and pool pump to run 24 hours per day until desired pool water temperature is
reached. When the water-in temperature reach setting, the unit just shuts off. The unit will now
automatically restart (as long as your pool pumps is running) when the pool temperature drops
more than 2 below set temperature.
The unit has a separate molded-in junction box with a standard electrical conduit nipple already
in place. Just remove the screws and the front panel, feed your supply lines in through the conduit
nipple and wire-nut the electric supply wires to the three connections already in the junction box
(four connections if three phase). To complete electrical hookup, connect heat pump by electrical
conduit, UF cable or other suitable means as specified (as permitted by local electrical authorities)
to a dedicated AC power supply branch circuit equipped with the proper circuit breaker, disconnect
or time delay fuse protection.
Disconnect - A disconnect means (circuit breaker, fused or un-fused switch) should be located
within sight of and readily accessible from the uni, this is common practice on commercial and
residential air conditioners and heat pumps. It prevents remotely-energizing unattended equipment
and permits turning off power at the unit while the unit is being serviced.
Water Flow Switch - the unit is equipped with a flow switch that turns it on when the pool pump is
running and shuts it off when the pump shuts off. This switch is the same type used in all gas pool
heaters and is factory adjusted for normal pool installations. If the pool water level is more than a
few feet above or below the thermostat knob of the unit, your dealer may need to adjust it at initial
startup.
Time Delay - the unit is equipped with a 3 minute built-in solid state restart delay included
to protect control circuit components and to eliminate restart cycling and contactor chatter.
This time delay will automatically restart the unit approximately 3 minutes after each control
circuit interruption. Even a brief power interruption will activate the solid state 3 minute restart
delay and prevent the unit from starting until the 5 minute countdown is completed. Power
interruptions during the delay period will have no effect on the 3 minute countdown.
SAKURA - Total Air Conditioning SolutionSAKURA - Total Air Conditioning Solution

3.INSTALLATION AND CONNECTION 3.INSTALLATION AND CONNECTION
3.1 Installation illustration
Water inlet
Water outlet
Sand filter
(or other type filter)
Pool
Water supply
Valve
Installation items:
The factory only provides the main unit and the water unit ; the oter items in the illustration
are necessary spare parts for the water system , that provided by users or the installer.
Attention:
Please follow these steps when using for the first time
1.open valve and charge water.
2.make sure that the pump and the water-in pipe have been filled with water.
3.close the valve and start the unit.
3.2 Swimming Pool Heat Pumps Location
The unit will perform well in any outdoor location provided that the following three factors
are present.
1.fresh air - 2.electricity - 3.pool filter piping
The unit may be installed virtually anywhere outdoors.
For indoor pools consult the supplier. Unlike a gas heater,
it has no draft or pilot light problem in a windy area.
Do not place the unit in an enclosed area with a
limited air volume, where the units discharge air
will be re-circulated.
Do not place the unit to shrubs which can block air
inlet. These locations deny the unit of a continuous
source of fresh air which reduces it efficiencyand
may prevent adequate heat delivery.
1000mm
800mm
800mm
800mm
2000mm
Air outlet
Air inlet
Air inlet
Air inlet
3.3 How Close To You Pool ?
Normally, the pool heat pump is installed within 7.5 metres of the pool. The longer
the distance from the pool, the greater the heat loss from the piping. For the most part,
the piping is buried. Therefore, the heat loss is minimal for runs of up to 15 metres
(15 metres to and from the pump = 30 metres total), unless the ground is wet or the
water table is high. A very rough estimate of heat loss per 30 metres is 0.6 Kw-hour,
(2000BTU) for every 5 difference in temperature between the pool water and the ground
surrounding the pipe, which translates to about 3% to 5% increase in run time.
3.4 Swimming Pool Heat Pumps Plumbing
The Swimming Pool Heat Pumps exclusive rated flow titanium heat exchanger
requires no special plumbing arrangements except bypass (please set the flow rate according
to the nameplate. The water pressure drop is less than 10kpa at max. Flow rate, since there is
no residual heat or flame temperatures, the unit does not need copper heat sink piping. PVC
pipe can be run straight into the unit.
Location: connect the unit in the pool pump discharge (return) line
downstream of all filter and pool pumps, and upstream of any chlorinators,
ozonators or chemical pumps.
Standard model have slip glue fittings which accept 40mm NB
PVC pipe for connection to the pool or spa filtration piping. By using a
50NB to 40NB you can plumb 50NB PVC piping straight into the unit.
Give serious consideration to adding a quick coupler
fitting at the unit inlet and outlet to allow easy draining
of unit for winterizing and to provide easier access
should servicing be required.
PVC COUPLER
RECOMMENDED (provided)
From pool
To pool
CONDENSATION DRAIN BARB FTG
Condensation: since the heat pump cools down the air about 4-5 , water may condense on the
fins of the horseshoe shaped evaporator. If the relative humidity is very high, this could be as much
as several litres an hour. The water will run down the fins into the basepan and drain out through
the barbed plastic condensation drain fitting on the side of the basepan. This fitting is designed to
accept 3/4 clear vinyl tubing which can be pushed on by hand and run to a suitable drain.
It is easy to mistake the condensation for a water leak inside the unit.
NB: A quick way to verify that the water is condensation is to shut off the unit and keep
the pool pump running. If the water stops running out of the basepan, it is condensation.
AN EVEN QUICKER WAY IS to TEST THE DRAIN WATER FOR CHLORINE - if the is no
chlorine present, then it is condensation.
SAKURA - Total Air Conditioning SolutionSAKURA - Total Air Conditioning Solution

3.INSTALLATION AND CONNECTION 3.INSTALLATION AND CONNECTION
3.1 Installation illustration
Water inlet
Water outlet
Sand filter
(or other type filter)
Pool
Water supply
Valve
Installation items:
The factory only provides the main unit and the water unit ; the oter items in the illustration
are necessary spare parts for the water system , that provided by users or the installer.
Attention:
Please follow these steps when using for the first time
1.open valve and charge water.
2.make sure that the pump and the water-in pipe have been filled with water.
3.close the valve and start the unit.
3.2 Swimming Pool Heat Pumps Location
The unit will perform well in any outdoor location provided that the following three factors
are present.
1.fresh air - 2.electricity - 3.pool filter piping
The unit may be installed virtually anywhere outdoors.
For indoor pools consult the supplier. Unlike a gas heater,
it has no draft or pilot light problem in a windy area.
Do not place the unit in an enclosed area with a
limited air volume, where the units discharge air
will be re-circulated.
Do not place the unit to shrubs which can block air
inlet. These locations deny the unit of a continuous
source of fresh air which reduces it efficiencyand
may prevent adequate heat delivery.
1000mm
800mm
800mm
800mm
2000mm
Air outlet
Air inlet
Air inlet
Air inlet
3.3 How Close To You Pool ?
Normally, the pool heat pump is installed within 7.5 metres of the pool. The longer
the distance from the pool, the greater the heat loss from the piping. For the most part,
the piping is buried. Therefore, the heat loss is minimal for runs of up to 15 metres
(15 metres to and from the pump = 30 metres total), unless the ground is wet or the
water table is high. A very rough estimate of heat loss per 30 metres is 0.6 Kw-hour,
(2000BTU) for every 5 difference in temperature between the pool water and the ground
surrounding the pipe, which translates to about 3% to 5% increase in run time.
3.4 Swimming Pool Heat Pumps Plumbing
The Swimming Pool Heat Pumps exclusive rated flow titanium heat exchanger
requires no special plumbing arrangements except bypass (please set the flow rate according
to the nameplate. The water pressure drop is less than 10kpa at max. Flow rate, since there is
no residual heat or flame temperatures, the unit does not need copper heat sink piping. PVC
pipe can be run straight into the unit.
Location: connect the unit in the pool pump discharge (return) line
downstream of all filter and pool pumps, and upstream of any chlorinators,
ozonators or chemical pumps.
Standard model have slip glue fittings which accept 40mm NB
PVC pipe for connection to the pool or spa filtration piping. By using a
50NB to 40NB you can plumb 50NB PVC piping straight into the unit.
Give serious consideration to adding a quick coupler
fitting at the unit inlet and outlet to allow easy draining
of unit for winterizing and to provide easier access
should servicing be required.
PVC COUPLER
RECOMMENDED (provided)
From pool
To pool
CONDENSATION DRAIN BARB FTG
Condensation: since the heat pump cools down the air about 4-5 , water may condense on the
fins of the horseshoe shaped evaporator. If the relative humidity is very high, this could be as much
as several litres an hour. The water will run down the fins into the basepan and drain out through
the barbed plastic condensation drain fitting on the side of the basepan. This fitting is designed to
accept 3/4 clear vinyl tubing which can be pushed on by hand and run to a suitable drain.
It is easy to mistake the condensation for a water leak inside the unit.
NB: A quick way to verify that the water is condensation is to shut off the unit and keep
the pool pump running. If the water stops running out of the basepan, it is condensation.
AN EVEN QUICKER WAY IS to TEST THE DRAIN WATER FOR CHLORINE - if the is no
chlorine present, then it is condensation.
SAKURA - Total Air Conditioning SolutionSAKURA - Total Air Conditioning Solution

2.SPECIFICATION
2.1 The dimensions for Swimming Pool Heat Pump Unit
108
1046
286
450
810
810
841
860
Water outlet
( 50)
Water intlet
( 50)
3.INSTALLATION AND CONNECTION
3.5 Swimming Pool Heat Pumps Electrical Wiring
NOTE: although the unit heat exchanger is electrically isolated from the rest of the unit,
it simply prevents the flow of electricity to or from the pool water. Grounding the unit is
still required to protect you against short circuits inside the unit. Bonding is also required.
3.6 Initial startup of the Unit
Note: in order for the unit to heat the pool or spa, the filter pump must be running to
circulate water through the heat exchanger.
Start up procedure - after installation is completed, you should follow these steps:
1. Turn on your filter pump. Check for water leaks and verify flow to and from the pool.
2. Turn on the electrical power supply to the unit, then press the key ON/OFF of wire controller,
it should start in several seconds.
3. After running a few minutes make sure the air leaving the top(side) of the unit is cooler
(between 5-10 ).
4. With the unit operation turn the filter pump off. The unit should also turn off automatically.
5. Allow the unit and pool pump to run 24 hours per day until desired pool water temperature is
reached. When the water-in temperature reach setting, the unit just shuts off. The unit will now
automatically restart (as long as your pool pumps is running) when the pool temperature drops
more than 2 below set temperature.
The unit has a separate molded-in junction box with a standard electrical conduit nipple already
in place. Just remove the screws and the front panel, feed your supply lines in through the conduit
nipple and wire-nut the electric supply wires to the three connections already in the junction box
(four connections if three phase). To complete electrical hookup, connect heat pump by electrical
conduit, UF cable or other suitable means as specified (as permitted by local electrical authorities)
to a dedicated AC power supply branch circuit equipped with the proper circuit breaker, disconnect
or time delay fuse protection.
Disconnect - A disconnect means (circuit breaker, fused or un-fused switch) should be located
within sight of and readily accessible from the uni, this is common practice on commercial and
residential air conditioners and heat pumps. It prevents remotely-energizing unattended equipment
and permits turning off power at the unit while the unit is being serviced.
Water Flow Switch - the unit is equipped with a flow switch that turns it on when the pool pump is
running and shuts it off when the pump shuts off. This switch is the same type used in all gas pool
heaters and is factory adjusted for normal pool installations. If the pool water level is more than a
few feet above or below the thermostat knob of the unit, your dealer may need to adjust it at initial
startup.
Time Delay - the unit is equipped with a 3 minute built-in solid state restart delay included
to protect control circuit components and to eliminate restart cycling and contactor chatter.
This time delay will automatically restart the unit approximately 3 minutes after each control
circuit interruption. Even a brief power interruption will activate the solid state 3 minute restart
delay and prevent the unit from starting until the 5 minute countdown is completed. Power
interruptions during the delay period will have no effect on the 3 minute countdown.
SAKURA - Total Air Conditioning SolutionSAKURA - Total Air Conditioning Solution

4.INSTRUCTION FOR WIRE CONTROLLER
4.1 keys functions of the Wire Controller
TIMER Key: set the desired timer on/off time and adjust the time
Running state(Press TIMER key once) Timer on / hour setting(Press it once again)
Timer on / minute setting (once again) Timer off / hour setting (once again)
Timer off /minute setting (once again) Running state
When in running state, press TIMER key for a long time, enter into time adjusting,
you can adjust the time as follow sequence:
Hour Minute Hour
After time adjusting, press TIMER key for a long time to quit.
SEARCH Key: Search temperature data and error codes;
When in normal running state, press this key, you can check the different
temperature data T1 T2 T3 T4 T1
When any malfunction occurs, press this key to check the error code.
(For example, when there are total three errors(E3,E4,E5)occur,
the controller will display as follow :E3 E4 E5 E3)
MODE Key: Mode transfer
AUTO COOLING HEATING AUTO
MODE
TIME HEAT
SEARCH
ON/OFF
RESET
Auto model
Cooling model
Heating model
Circulating
Water Pump
Defrosting operation
Auxiliary Heater
(reserved)
* Temperature
Display section
LCD screen
* Time Display
section
* Timer key
* Search key
Auxiliary Heater
key (reserved)
Turn on or turn off
the unit
Press this key, the
wired controller
restart
Press these two keys
to set temperature and
adjust time
* Mode key
1.PREFACE
In order to provide our customers with quality, reliability and versatility, this
product has been made to strict production standards. This manual includes
all the necessary information about installation, debugging, discharging and
maintenance. Please read this manual carefully before you open or maintain
the unit. The manufacture of this product will not be held responsible if someone
is injured or the unit is damaged, as a result of improper installation, debugging,
or unnecessary maintenance. It is vital that the instructions within this manual
are adhered to at all times.
The unit must be installed by qualified personnel.
1 Durable
The heat exchanger is made of PVC & titanium tube which can withstand
prolonged exposure to corrosives such as chlorine.
The unit can only be repaired by qualified installer centre personnel or an
authorised dealer.
Maintenance and operation must be carried out according to the recommended
time and frequency, asstated in this manual.
Use genuine standard spare parts only.
Failure to comply with these recommendations will invalidate the warranty.
Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the
temperature constant. The indoor unit can be discretely hidden or semi-hidden
to suit a luxury house.
This type of pump has the following characteristics:
2 Installation flexibility
The unit can be installed outdoors or indoors.
3 Quiet operation
The unit comprises an efficient rotary/scroll compressor and a low noise
fan motor, which guarantees its quiet operation.
4 Advanced controlling
The unit includes micro-computer controlling, allowing all operation
parameters to be set. Operation status can be displayed on the wire
controller. You can also choose remote controlling.
SAKURA - Total Air Conditioning Solution SAKURA - Total Air Conditioning Solution

CONTENTS
1. Preface 1
2. Specifications 2
2.1 Dimensions for Swimming Pool Heat Pump Unit 2
3. Installation and Connection 3
3.1 Installation of System 3
3.2 Swimming Pool Heat Pumps Location 3
3.3 How Close To Your Pool? 4
3.4 Swimming Pool Heat Pumps Plumbing 4
3.5 Swimming Pool Heat Pumps Electrical Wiring 5
3.6 Initial Start-up of the Unit 5
4.INSTRUCTION FOR WIRE CONTROLLER
Temperature Display section:
When checking the temperature, code name displays on the left side and
at the same time the corresponding temperature value displays on right side;
Code name of the temperature
T1 inlet water temperature T2 outlet water temperature
T3 pipe coil temperature T4 ambient temperature
T5,T6- reserved
The setting temperature
The actual temperature
Time Display section:
Timer On icon displays this icon when you have set Timer On function
and flashes when you are setting
Timer Off icon displays this icon when you have set Timer Off function
and flashes when you are setting
Display the time in normal state.
When in timer on/off setting and time adjusting states, the corresponding icon will flash
4.2 Display screen description
This function is activated by 43# data in EEPROM after the unit powers on.
4.3 Auto-restart function
without auto-restart function, the unit will be in stand-by when the power
supplies again. The screen only displays the time. The timer on/off function
is invalid.
If
the unit with auto-restart function, once the unit off the power abnormally,
and then the power supplies again, the unit will run as the previous condition.
If
When any malfunction occurs, the screen will display relating error code.
4.4 Alarms instruction sheet(error code display priority is from E0 to ED)
When any malfunction occurs, the screen will flash the error code.
Error
code Cause
E0
Malfunction and
Protection
Error
code
E9
Communication error
between wire controller
and the unit
( mainboard error )
Wire controller receives
abnormal signal from
mainboard
Cause
Malfunction and
Protection
Fan motor error or
lack water protection Fan motor or water
flow valve error
E1
EA
Wire controller sensor
error
Communication error
between mainboard and
wire controller
(wire controller error)
Mainboard receives
abnormal signal from
wire controller
E2
EB
Wire controller EEPROM
error
Coil sensor error Coil sensor T3 is open
circuit or short circuit
E3
EC
Inlet water temperature
sensor error
Inlet water temperature
sensor T1 is open circuit
or short circuit
High pressure protection Compressor high
pressure switch acts
E4
ED
Outlet water temperature
sensor error
Outlet water temperature
sensor T2 is open circuit
or short circuit
Low pressure protection Compressor low
pressure switch acts
E5 Outside ambient
temperature sensor error
Outside ambient
temperature sensor
T4 is open circuit or
short circuit
E6 prevent frostbite protection
in cooling state
E7 EEPROM error EEPROM is wrong in
read-write
E8 Wrong phase/ absent
phase protection
Power supply phases
don't connect in correct
order or absent some
4. Instruction for wire controller 6
4.1 Keys functions of the Wire Controller 6
4.2 Display screen description 7
4.3 Auto-restart function 7
4.4 Alarms instruction sheet 7
5. Maintenance 8
SAKURA - Total Air Conditioning Solution SAKURA - Total Air Conditioning Solution

5.MAINTENANCE
Check the water supply device and the release often. You should avoid the
condition of no water or air entering into system, as this will influence unit s
performance and reliability. You should clear the pool/spa filter regularly to
avoid damage to the unit as a result of the dirty of clogged filter.
The area around the unit should be dry, clean and well ventilated. Clean the
side heating exchanger regularly to maintain good heat exchange as conserve
energy.
The operation pressure of the refrigerant system should only be serviced by
a certified technician.
Check the power supply and cable connection often, should the unit begin to
operate abnormally, switch it off and contact your certified technician.
Discharge all water in the water pump and water system, so that freezing of
the water in the pump or water system does not occur. You should discharge
the water at the bottom of water pump if the unit will not be used for an
extended period of time. You should check the unit thoroughly and fill the
system with water fully before using it for the first time after a prolonged
period of no usage.
SAKURA - Total Air Conditioning Solution
SAKURA CORPORATION
Tel: +81-45-949-8550 Fax: +81-45-949-8551
2-17-1, Eda-minami, Tsuzuki-ku, Yokohama, Kanagawa,224-0007, Japan
Table of contents
Popular Swimming Pool Heater manuals by other brands

Raypak
Raypak raytherm P-1223 Specifications

Hayward
Hayward H-Series manual

Sungrabber
Sungrabber Solar Pool Heater Installation & owner's manual

Sengoku
Sengoku CT1100 owner's manual

Hayward
Hayward ABG1001 Installation, operation & service procedures

SmartPool
SmartPool S220 Installation and operation manual

fluidra
fluidra Astral Pool IHPt127 Installation instructions manual

Hayward
Hayward SUMHEAT HP5171DT3 Installation instructions manual

Comfort Zone
Comfort Zone CZ2020O owner's manual

Sun Heat
Sun Heat 1500 Operation manual and warranty

Astral Pool
Astral Pool ECO ELECTRICHEAT Start-up and operation

Zibro
Zibro LC - 320 operating manual