Sanako Lab 100 User manual

Dubai – Leeds – Lyon – New York – Shanghai – Turku
Release Date:19.3.2008 Page: 1 / 5
Document number: 0807903
Document type: Technical Document
Product name and version: SANAKO Lab 100 Master Cassette
SANAKO Corporation
P.O.Box 41, Kaurakatu 46, FI-20741 Turku, Finland,
http:// www.sanako.com
SANAKO User Club and Discussion Forum
http://members.sanako.com
SANAKO LAB 100 MASTER CASSETTE USER GUIDE
OVERVIEW
A durable plug-and-play cassette recorder designed especially for using C-cassette based
teaching materials with the SANAKO Lab 100 digital language lab. Unlike other cassette
decks the Lab 100 cassette recorder contains a special digital input and output interface to
the SANAKO Lab 100 system.
In addition to standard cassette recorder functions the unit allows for adjustment of the
program playback speed. This means the teacher can adjust the program to the listening
level of the class.
With its built in Program Source Interface (Lab 100 PSI), the SANAKO Lab 100 Master
Cassette can be used to connect a second audio program source (e.g. CD player) to the
Lab 100 system.
This document explains how you can connect the SANAKO Lab 100 Master Cassette to
the SANAKO Lab 100 language learning systems in order to play audio material from
cassettes to students.

Dubai – Leeds – Lyon – New York – Shanghai – Turku
Release Date:19.3.2008 Page: 2 / 5
Document number: 0807903
Document type: Technical Document
Product name and version: SANAKO Lab 100 Master Cassette
SANAKO Corporation
P.O.Box 41, Kaurakatu 46, FI-20741 Turku, Finland,
http:// www.sanako.com
SANAKO User Club and Discussion Forum
http://members.sanako.com
SANAKO LAB 100 MASTER CASSETTE CONNECTORS
SCU Interface to Lab 100 SCU32/SCU64. When connected to SCU, Lab
100 Master Cassette is powered by the SCU.
RJ25 connectors Not used
GLI ON/OFF Jumper to enable/disable the built-in Ground Loop Isolator. GLI can
be set to the ON position when used with an external
source/amplifier if ground noise occurs.
Line Out R L Line level stereo output for external amplifier
Lab 100 Source (R) Line level mono input for Lab 100 system. External sources
connected to this input can be used with Lab 100 when configured
as PSI source right channel in Lab 100 Config.
Input Level Adjusts the input level of Lab 100 Source (R) –input
12V Voltage input for external power source. An external power source is
needed when the unit is used as a standalone cassette deck (not
connected to SCU).
Voltage requirements: 12V DC, 200mA

Dubai – Leeds – Lyon – New York – Shanghai – Turku
Release Date:19.3.2008 Page: 3 / 5
Document number: 0807903
Document type: Technical Document
Product name and version: SANAKO Lab 100 Master Cassette
SANAKO Corporation
P.O.Box 41, Kaurakatu 46, FI-20741 Turku, Finland,
http:// www.sanako.com
SANAKO User Club and Discussion Forum
http://members.sanako.com
CONNECTING THE SANAKO LAB 100 MASTER CASSETTE
SANAKO Lab 100
Connect a Cat5 cable between the Lab 100 Master Cassette port marked with ‘SCU’ and
the Lab 100 SCU port.
In the Lab 100 Config application, define the SCU port where the Lab 100 Master Cassette
is connected. The ‘Source type’ is Dual Channel PSI (L). Change the source name to e.g.
Cassette.
The ‘Lab 100 Source (R)’ connector can be setup as Dual Channel PSI (R) with the
Cassette Recorder port to connect an external source.
Lab 100 Config set up with Lab 100 Master Cassette and with Lab 100 Source (R) configured for an
external source.

Dubai – Leeds – Lyon – New York – Shanghai – Turku
Release Date:19.3.2008 Page: 4 / 5
Document number: 0807903
Document type: Technical Document
Product name and version: SANAKO Lab 100 Master Cassette
SANAKO Corporation
P.O.Box 41, Kaurakatu 46, FI-20741 Turku, Finland,
http:// www.sanako.com
SANAKO User Club and Discussion Forum
http://members.sanako.com
Connecting two Lab 100 Master Cassettes to SANAKO Lab 100
Connect the primary Lab 100 Master Cassette with a Cat 5 cable. Connect the secondary
Lab 100 Master Cassette from the ‘Line Out R L’ connector to the primary cassette ‘Lab
100 Source (R)’ connector with a stereo to mono Y-cable.
Audio connection between two Lab 100 Master Cassettes using the same SCU port.
Lab 100 Config settings:
Two Lab 100 Master Cassettes using one SCU port
Alternative solution to connect two Lab 100 Master Cassettes:
Secondary Lab 100 Master Cassette can also be connected to free SCU port if available. This way
only a standard Ethernet cable is needed instead of stereo to mono Y-cable.

Dubai – Leeds – Lyon – New York – Shanghai – Turku
Release Date:19.3.2008 Page: 5 / 5
Document number: 0807903
Document type: Technical Document
Product name and version: SANAKO Lab 100 Master Cassette
SANAKO Corporation
P.O.Box 41, Kaurakatu 46, FI-20741 Turku, Finland,
http:// www.sanako.com
SANAKO User Club and Discussion Forum
http://members.sanako.com
For use as stand alone cassette player
Connect a +12 V (DC) power source to the voltage input of the Lab 100 Master Cassette.
Connect the external amplifier with line level input to the ‘Line Out’ connectors. All other
functions except recording are available.
Notes:
•The Modular6 / RJ25 headset connectors are not used. No audio can be heard
or recorded from headsets connected to the Lab 100 Master Cassette player.
•No cables are included in the Lab 100 Master Cassette package.
•The cable between the Lab 100 Master Cassette and the SCU is a Cat 5 UTP
Ethernet cable. The cable can be ordered separately from SANAKO.
•The cable type between the Lab 100 Master Cassette Line Out and the external
amplifier is a normal 2xRCA stereo cable. Alternatively e.g. 2xRCA - 3,5mm
minijack cable can be used.
•The cable type between the Lab 100 Master Cassette and an external audio source
is a mono cable with RCA connector. E.g. stereo to mono Y-cable with RCA
connectors can be used to connect an external stereo audio source to the Lab 100
Master Cassette source input. A Y-cable is needed to hear both connected
channels.
Table of contents