S&G SG-0007C User manual

! "#$ %&
'() Operating the system without water will cause severe damage.
'() SHOCK HAZARD! o user serviceable parts. Do not attempt to service this control. Contact your
dealer or service center for assistance. Follow all user’s manual power connection instructions. Installation must
be performed by a certified licensed electrician and all grounding connections must be properly installed.
(&(
*+ Please open the tub skirt according to instruction on it, connect the power supply correctly. If the power
supply is 220V/50HZ, the wires serving as equipotential bonding conductors shall have a cross
sectional area not less than 3×10mm2. If the power supply is 380V/50HZ, the wires serving as
equipotential bonding conductors shall have a cross sectional area not less than 5×6mm2.The protection
system should be based on a residual current device (RCD). Be sure that the earth cable connection is
correctly made. The circuit diagram of hot tub is shown as following. (Fig 1)
,$*+
-+ Before infuse water into hot tub for using, please check the valve for each pipeline. The hot tub’s drain
valve must be in normal close while valves for other pipeline must be in normal open. After confirm
1

everything is ok, fill the spa with cold water 4’’ to 6’’ (100 to 150mm) below the top edge of the spa and
after that, put the cartridge filter or filter bag into the filter area. Do not overfill as the spa’s water level
will rise as each person enters the spa. Always keep the spa water lever above the jet openings.
((&% !
(Fig 2)
● .,%/.+)Connect the power supply, press key, all the control systems are ready to
run (indicator light is on), and the circulation and Ozone disinfection system go into working
automatically (When first time connect the power supply and press key, the panel will show E1,
namely automatic system-checking for 60 seconds; and if the water temperature does not reach the pre-
set one, the heating system will start to work in 10 seconds after automatic system-checking). The
panel will display the symbols of circulation and Ozone (if the heating system is working, its symbol
will be displayed on the panel too). Meanwhile, the panel will display the detected water temperature
which will refresh once every 60 seconds.
●00.) press (PUMP1) key, its symbol will show on the panel, Pump1 will be activated;
press (PUMP2) key, its symbol will show on the panel, Pump2 will be activated (PUMP 2 is
optional for some models); press (PUMP3) key, its symbol will show on the panel, Pump3 will
be activated (PUMP 2 is optional for some models).
1) There are some air valves on the topside of spas near the seats. They are to control the
strength of hydro-massage in the seats respectively.
222.) Press key, its symbol will show on the panel, the air massage system goes to
work instantly.
3.,4+)Press key can turn on or off the Ozone disinfection system (Ozone and
circulation pump work automatically when activating the spa).
0.)When the control systems are ready to work, first press key, its symbol will show
on the panel, the underwater lights are on, the color will change automatically; second press, the color
will be fixed on a certain color; press for the third time to shut it off.
2

0.," $/ .+)Press key, the panel will display
the water temperature set last time and keep flashing: Press key to adjust temperature to highest
at 42℃; press key to adjust temperature to lowest at 10℃. It will automatically store and return
to show the current water temperature after flashing 3 seconds.
5(67.,65756 %8%+) When the control systems are
ready to work, first press key, it will go into Radio function, and the panel shows radio channel
set last time (under Radio status, press key to select pre-stored radio station); second press,
it will go into TV function (this function is optional), the panel shows TV symbol; third press, it will
go into DVD function (this function is optional), the panel shows symbols of DVD at the same time
(Under DVD status, press key to adjust the volume of DVD); press for the fourth time, the
panel will show the detected water temperature.
67. ," $/ .+) Under Radio status, first press
key, the panel will show 2-digit volume, press can adjust volume upwards or
downwards (the panel will automatically show radio frequency when stop adjusting for 3 seconds).
Second press ,the current frequency will flash, press key to adjust the current frequency ,
it will store automatically after flashing 3 seconds. Third press, the panel will show radio channel,
press key to select pre-stored radio station ( the panel will automatically show previous
radio frequency when stop adjusting for 3 seconds). Long press for 5 seconds, the system will
automatically search radio frequency again and store the searched frequency at different channel
sequentially.
9$ 8)After the control systems are ready to work, the heater will start working 10 seconds
after the circulation pump is activated unless the temperature sensor detect that the set temperature is
lower than the detected one. When the water temperature reach set temperature, the heater will stop
working automatically. When the water temperature is under 2 of the preset one, the heater will be℃
activated to work again.
1)The heater will not be activated to work if there is not enough water flow trans-fluxing it.
(!. 8"/%8% )Long press key again for 20 seconds, the
system can be converted between interlock mode or non-interlock mode (the indicator light on
key shows 5under interlock mode; while it showsunder non-interlock mode). When it
is in interlock mode, the heater will stop when you press any key of pumps and bubble. This feature is
to reduce the power needed for the spa so that it can match the power limit of some countries. In non-
interlocked mode, the heater will keep running when the other pumps are activated unless the water
temperature reaches the set temperature.
8% : !!.$ 8) When the panel shows EO which means the
3

temperature sensor is disconnected, check the wiring of temperature sensor to see whether it is
disconnected. When the panel shows E1 which means the temperature sensor is short-circuited,
replace the temperature sensor with a new one. The heating system can not be activated under the
above two situations.
'!.$%! 8!!%8%)In daily usage, the blockage of
filtration medium (cartridge filter or filter bag) will occur. The severe blockage will lead to the
intermittent lack of water for the filtration pump. When lack of water, the filtration pump and heater
will stop working automatically. At this moment, the symbol of filtration pump on control panel
will flash unceasingly, which reminds the user that it is time to clean or replace the filtration medium.
After cleaning or replacing the filtration medium, press several times so that it can evacuate the
air inside the pipe until the filtration pump work normally.
4$ 8) After power on to enter standby status (the indicator light on key
flashes), the anti-freezing system will be activated instantly. The circulation pump and heating system
will automatically stop at the default temperature of above 10 . When the water temperature in the℃
spa drops below 9 , the circulation pump, heater and air blower will work automatically, Pump1 will℃
automatically start to work in about 85 seconds; and it will stop after working about 85 seconds; then
Pump 2 (if equipped) will start to work for about 85 seconds and stop; finally comes for Pump 3 (if
equipped) working for about 85 seconds then stops. Pump1, Pump2 and Pump3 will continuously
cycle among them. When the detected water temperature reaches 10 , all the pumps and heater will℃
stop working. When this system is running, the screen background light is on. When the water
temperature reaches 10 , the screen returns to the standby status. ℃
8.) When enjoy the massage functions, in order to ensure the cleanness of water in the spa,
please switch the spa into manual mode.
8!/.$8)(The factory-setting for the spa is automatic mode)
Long press key for 3 seconds to enter automatic mode (the indicator light on key will
show ). The circulation pump will start to run automatically for 60 minutes and then stops for
180 minutes. It will repeat the cycle continuously. During the running time, key will show
, and the panel will display “O ”, detected water temperature and the symbol of ozone
alternately. The heater will go to work instantly if the water temperature is 2 lower than the preset℃
temperature. And its symbol will be displayed on the panel. During the stop running time, key
will show , and the panel will display “OFF” and detected water temperature alternately.
When the water temperature is 2 lower than the preset temperature, the circulation pump, ozone℃
generator and heater will go to work instantly until it reaches the preset temperature. The keys
are non-functional keys, they act as indicating keys.
1)
If the spa is in automatic working mode, please don’t turn off the spa when you don’t use it and
make sure to keep the spa always “;.
When enters into automatic mode, the filtration pump will be controlled by temperature. If the
4

water temperature is lower than the preset one, the filtration pump and heater will work till the
water temperature reaching the preset one. Then, the filtration pump will return to work for 1
hour and stop for 3 hours repeatedly. When quit from the automatic mode, the filtration pump
won’t controlled by temperature.
Each time when turn on the spa, the system will go into the mode set last time. Long press
or key (the indicator will show ) to switch between automatic mode and manual
mode.
When enters into automatic mode:
A: The preset temperature is lower than the actual water temperature: only the filtration pump
works while the heater does not work.
B: The preset temperature is higher than the actual water temperature: when under the state of
“stop”, if the water temperature has not reached the preset one, the filtration pump and heater
will continue to work until the water temperature reaches the preset one. The Ozone will
automatically work together with the filtration pump and heater in automatic mode.
Control box environmental overheat protection function: When the inside temperature of the
control box exceed an appropriate temperature, the control system will be shut down
automatically. When the temperature returns to appropriate temperature, the indicator light of
O /OFF key flashes and the control panel recovers to standy status. Pressing O /OFF, the
control system can be used as normal.
Water overheat protection function: When the water in spa reaches to 43℃,some parts stop
working and “OH” shows on the screen. The above parts includes air blower, heater and all
massage pumps. When the temperature down to 40 , “OH” disappears. The functions can be℃
used as normal by controling the control panel.
Screen protection function: The backlight of screen will be turned off after 1 minute switching on
the control panel. The indicator lights of function keys on the panel stay lit.
Time controls functions: The massage pump and air blower will be shut down automatically after
running 1 hour. All indicator lights of functional keys lit. The heater and circulation pump are
controled by temperature.
Automatic cleaning function :Keep the spa power on. The system will do the clean
automatically every 12 hours from shutting off the spa by pressing the O /OFF key. All the
equipments will go into working for one minute in turn and stop working automatically. Their
order is air blower and circulation pump (working in the same time), PUMP1, PUMP2 and
PUMP3, four cycles in total. After one equipment stopping, the next one will go into working
automatically, until the last (fourth) cycle.
(((&( ! "8"!.0: <
The preset number to open the combination lock at 0-0.
You can reset the combination to your own number as follows: Open your combination lock. Use
your ball point pen or other small strike to press in the reset button. Rotate the dial to the number that
you want to set while keeping the reset button depressed. Release the reset button and reset the other
side of the lock by the same way.
(7&$ !
5

Do not use cleaners or compounds containing harsh abrasives. Also, avoid using heavy-duty
rubbing or buffing compounds. Use a soft liquid cleaner. A gentle mixture of any mild soap and
warm water will generally dissipate most common soil from the surface. Using a soft cloth, wash the
area to be cleaned and rinse. If stubborn dirt remains, as a stain embedded in the grain of the vinyl,
use a soft brush, and if necessary, a touch of cleaning powder. In both situations, rinse and dry with a
soft cloth.
7&( ! /
1) Open the skirt panel of drain valve to open the red ball valve (the ball valve connecting to the black
drain valve is closed when it is out of factory).
2) Take out the small plug and then connect a hose to it. Loose the drain vale anticlockwise to open the
drain valve and the water will come out. After finishing draining, screw down the drain valve
clockwise again to close it.
8.)
1) The remaining water at the bottom of spa needs to be emptied by hand and small cup.
2) If you need to dry the hot tub completely, please activate the air blower running for a while to drain
the water in the air pipeline.
6
Table of contents
Popular Control Panel manuals by other brands

HIK VISION
HIK VISION AX DS-PWA32-H manual

VisionNet
VisionNet 63303 Installation & operating guide

Fire-Lite
Fire-Lite The Sensiscan 200 Installation, operation, and programming manual

HIK VISION
HIK VISION DS-PK-LRT User manual & operation command

Spectron
Spectron spectrocem BE56-2 user manual

Technoalarm
Technoalarm TP4-20 user manual