manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CAME
  6. •
  7. Control Panel
  8. •
  9. CAME ZLX24SA User manual

CAME ZLX24SA User manual

Other manuals for ZLX24SA

1

This manual suits for next models

2

Other CAME Control Panel manuals

CAME ZE5 User manual

CAME

CAME ZE5 User manual

CAME ZLJ24 User manual

CAME

CAME ZLJ24 User manual

CAME ZC3 User manual

CAME

CAME ZC3 User manual

CAME Z Series User manual

CAME

CAME Z Series User manual

CAME Z Series User manual

CAME

CAME Z Series User manual

CAME ZL60 User manual

CAME

CAME ZL60 User manual

CAME Z Series User manual

CAME

CAME Z Series User manual

CAME ZL19N User manual

CAME

CAME ZL19N User manual

CAME IO-RS485 User manual

CAME

CAME IO-RS485 User manual

CAME ZT6 User manual

CAME

CAME ZT6 User manual

CAME Z Series User manual

CAME

CAME Z Series User manual

CAME TS07 Manual

CAME

CAME TS07 Manual

CAME Z Series User manual

CAME

CAME Z Series User manual

CAME ZLJ14 User manual

CAME

CAME ZLJ14 User manual

CAME ZL22N User manual

CAME

CAME ZL22N User manual

CAME Z Series User manual

CAME

CAME Z Series User manual

CAME Z Series User manual

CAME

CAME Z Series User manual

CAME Z Series User manual

CAME

CAME Z Series User manual

CAME ZL60 User manual

CAME

CAME ZL60 User manual

CAME ZF1N110 User manual

CAME

CAME ZF1N110 User manual

CAME Z Series User manual

CAME

CAME Z Series User manual

CAME Z 24 Series ZL170N User manual

CAME

CAME Z 24 Series ZL170N User manual

CAME ZL180 SERIES User manual

CAME

CAME ZL180 SERIES User manual

CAME ZA3P User manual

CAME

CAME ZA3P User manual

Popular Control Panel manuals by other brands

GENEVO PRiMA 6 installation manual

GENEVO

GENEVO PRiMA 6 installation manual

NAPCO X 255 - Programming instructions

NAPCO

NAPCO X 255 - Programming instructions

Next Systems UNIR1 230 instruction manual

Next Systems

Next Systems UNIR1 230 instruction manual

HORNER HE-XPW1E0 user manual

HORNER

HORNER HE-XPW1E0 user manual

DSC CLASSIC PC1555 instruction manual

DSC

DSC CLASSIC PC1555 instruction manual

Bosch Solution 2000 installation guide

Bosch

Bosch Solution 2000 installation guide

VRinsight MS Panel user manual

VRinsight

VRinsight MS Panel user manual

Zeiss SYCOP 3 Quick reference guide

Zeiss

Zeiss SYCOP 3 Quick reference guide

HULTSTEINS ECOFRIDGE DISPLAY user manual

HULTSTEINS

HULTSTEINS ECOFRIDGE DISPLAY user manual

Elkron C420 Programming manual

Elkron

Elkron C420 Programming manual

GST GST200-2 Installation and operation manual

GST

GST GST200-2 Installation and operation manual

Efka Variocontrol V810 instruction manual

Efka

Efka Variocontrol V810 instruction manual

RDZ PC-HRX user manual

RDZ

RDZ PC-HRX user manual

STG-BEIKIRCH MZ3 operation instruction

STG-BEIKIRCH

STG-BEIKIRCH MZ3 operation instruction

AMX AutoPatch CP-15 instruction manual

AMX

AMX AutoPatch CP-15 instruction manual

Cebora 208-10 instruction manual

Cebora

Cebora 208-10 instruction manual

Satel CA-6 KLED-S user manual

Satel

Satel CA-6 KLED-S user manual

Evolution IQ plus 800 installation manual

Evolution

Evolution IQ plus 800 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ZLX24SA ZLX24SR
INSTALLATION MANUAL
FA01412-EN
EN English
Page 2- Manual FA01412-EN - 01/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
GENERAL PRECAUTIONS FOR INSTALLERS
Important safety instructions.
Please follow all of these instructions. Improper installation may cause
serious bodily harm.
Before continuing, please also read the general precautions for users.
Only use this product for its intended purpose. Any other use is hazardous. •
The manufacturer cannot be held liable for any damage caused by improper,
unreasonable or erroneous use. • This product has been designed to be assembled
to partly completed machinery and/or equipment so as to build machinery as
regulated by the Machinery Directive 2006/42/EC. • The final installation must
comply with the Machinery Directive (2006/42/EC) and the European reference
standards in force. • The manufacturer declines any liability for using non-original
products, which would also void the warranty. • All operations indicated in this
manual must be carried out exclusively by skilled and qualified personnel and in
full compliance with the regulations in force. • The device must be installed, wired,
connected and tested according to good professional practice, in compliance
with the standards and laws in force. • Make sure the mains power supply
is disconnected during all installation procedures. • All the components (e.g.
actuators, photocells and sensitive edges) needed for the final installation to comply
with the Machinery Directive (2006/42/EC) and with the reference harmonised
technical standards are specified in the general CAME product catalogue or on the
website www.came.com. • Check that the temperature ranges given are suitable
for the installation site. • Make sure that no direct jets of water can wet the product
at the installation site (sprinklers, water cleaners, etc.). • Make sure you have set
up a suitable dual-pole cut-o device along the power supply that is compliant with
the installation rules. It should completely cut o the power supply according to
category III surcharge conditions. • Demarcate the entire site properly to prevent
unauthorised personnel from entering, especially minors. • Use suitable protection
to prevent any mechanical hazards due to persons loitering within the operating
range of the operator.
Page 3- Manual FA01412-EN - 01/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
• The electrical cables must pass through special pipes, ducts and cable glands
in order to guarantee adequate protection against mechanical damage. • The
electrical cables must not touch any parts that may overheat during use (such
as the motor and transformer). • Before installation, check that the guided part
is in good mechanical condition, and that it opens and closes correctly. • The
product cannot be used to automate any guided part that includes a pedestrian
gate, unless it can only be enabled when the pedestrian gate is secured. • Make
sure that nobody can become trapped between the guided and fixed parts, when
the guided part is set in motion. • All fixed controls must be clearly visible after
installation, in a position that allows the guided part to be directly visible, but far
away from moving parts. In the case of a hold-to-run control, this must be installed
at a minimum height of 1.5 m from the ground and must not be accessible to
the public. • If not already present, apply a permanent tag that describes how to
use the manual release mechanism close to it. • Make sure that the operator has
been properly adjusted and that the safety and protection devices and the manual
release are working properly. • Before handing over to the final user, check that the
system complies with the harmonised standards and the essential requirements
of the Machinery Directive (2006/42/EC). • Any residual risks must be indicated
clearly with proper signage axed in visible areas, and explained to end users.
• Put the machine’s ID plate in a visible place when the installation is complete.
• If the power supply cable is damaged, it must be immediately replaced by the
manufacturer or by an authorised technical assistance centre, or in any case, by
qualified sta, to prevent any risk. • Keep this manual inside the technical folder
along with the manuals of all the other devices used for your automation system. •
Make sure to hand over to the end user all the operating manuals of the products
that make up the final machinery.
DISMANTLING AND DISPOSAL
Page 4- Manual FA01412-EN - 01/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
CAME S.p.A. employs an Environmental Management System at its premises. This system is certified and compliant with
the UNI EN ISO 14001 standard to ensure that the environment is respected and safeguarded. Please continue safeguarding
the environment. At CAME we consider it one of the fundamentals of our operating and market strategies. Simply follow these
brief disposal guidelines:
DISPOSING OF THE PACKAGING
The packaging materials (cardboard, plastic, etc.) can be disposed of easily as solid urban waste, separated for recycling.
Before dismantling and disposing of the product, please always check the local laws in force.
DISPOSE OF THE PRODUCT RESPONSIBLY.
DISPOSING OF THE PRODUCT
Our products are made of various materials. Most of these materials (aluminium, plastic, iron and electrical cables) are
classified as solid urban waste. They can be separated for recycling and disposed of at authorised waste treatment plants.
Other components (electronic boards, transmitter batteries, etc.) may contain pollutants.
These must be removed and disposed of by an authorised waste disposal and recycling firm.
It is always advisable to check the specific laws that apply in your area.
DISPOSE OF THE PRODUCT RESPONSIBLY.
Page 5- Manual FA01412-EN - 01/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
PRODUCT DATA AND INFORMATION
Key
This symbol shows which parts to read carefully.
This symbol shows which parts describe safety issues.
This symbol shows what to tell users.
The measurements, unless otherwise stated, are in millimetres.
Description
801QA-0060
ZLX24SA - Multifunction control panel, with 230 VAC power supply, for 24 V swing gates with two leaves, with graphic
programming display and signalling, safety device self-diagnostics, adaptive speed and torque technology, BUS CXN, 4 safety
inputs and memory space for up to 1000 users.
801QA-0080
ZLX24SR - Multifunction control panel, with 120 VAC power supply, for 24 V swing gates with two leaves, with graphic
programming display and signalling, safety device self-diagnostics, adaptive speed and torque technology, BUS CXN and 4
safety inputs.
Technical data
MODELS ZLX24SA ZLX24SR
Power supply (V - 50/60 Hz) 230 AC 120 AC
Motor power supply (V) 24 DC 24 DC
Board power supply (V) 24 DC 24 DC
Standby consumption (W) 33
Power (W) 260 260
Transformer thermal protection (°C) 120 120
Colour RAL 7040 RAL 7040
Operating temperature (°C) -20 ÷ +55 -20 ÷ +55
Cycles/hour 20 20
Consecutive cycles 20 20
Protection rating (IP) 54 54
Insulation class II
Fuse table
MODELS ZLX24SA ZLX24SR
Line fuse 3.15 A F 4 A F
Control-board fuse 1.6 A T 1.6 A T
Accessory fuse 1.6 A F 1.6 A F
Page 6- Manual FA01412-EN - 01/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Description of parts
1Line fuse
2Power supply terminal board
3Terminal board for connecting control devices
4Terminal board for connecting the safety devices
5Terminal board for B1-B2 output
6Memory Roll card connector
7Connector for CAME KEY
8Display
9Programming buttons
10 RSE card connector
11 RIO CONN card connector
12 Connector for plug-in radio frequency card (AF)
13 Earthing star point
14 Terminal board for CRP connection
15 Terminal board for connecting the antenna
16 Terminal board for BUS accessories
17 Terminal boards for connecting micro limit switches (NC
contact)
18 Terminal board for connecting the gearmotor with
encoder or with slowdown switch and electric lock
19 Accessories fuse
20 Control board fuse
21 Terminal board for connecting the signalling devices
22 Terminal board for power supply to the control board
23 Transformer
Page 7- Manual FA01412-EN - 01/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Optional accessories
24 RGSM001 module (806SA-0010)
25 SMA module (009SMA)
26 RLB battery charger board (002RLB)
ZLX24S can use two dierent types of emergency battery, installed on an external panel:
- Two 7Ah batteries (846XG-0030) to manage all motors required for the control panel.
- Two 2.3Ah batteries (846XG-0020) to manage motors with low current draw.
Page 8- Manual FA01412-EN - 01/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Size
210
125
240 140
242
296
320
==
Cable types and minimum thicknesses
Cable length (m) up to 20 from 20 to 30
Power supply 230 V AC 3G x 1.5 mm² 3G x 2.5 mm²
24 V AC/DC flashing beacon 2 x 0.5 mm² 2 x 0.5 mm²
TX Photocells 2 x 0.5 mm² 2 x 0.5 mm²
RX photocells 4 x 0.5 mm² 4 x 0.5 mm²
12 V DC electric lock 2 x 1 mm² 2 x 1.5 mm²
Command and control devices *no. x 0.5 mm² *no. x 0.5 mm²
* no. = see product assembly instructions
Warning: the cable cross-section is indicative and varies according to the motor power and cable length.
When operating at 230 V and outdoors, use H05RN-F cables compliant with 60245 IEC 57 (IEC); when operating
indoors, use H05VV-F cables compliant with 60227 IEC 53 (IEC). For power supplies up to 48 V, you can use FROR 20-22 II
cables compliant with EN 50267-2-1 (CEI).
To connect the antenna, use RG58 cable (up to 5 m).
To connect to the CRP, use a UTP CAT5 cable (up to 1,000 m long).
If the cable lengths dier from those specified in the table, define the cable cross-sections according to the actual
power draw of the connected devices and in line with regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, recalculate the values in the table according to the actual power
draw and distances. For information on connecting products not covered in this manual, please see the documentation
accompanying the products themselves.
To connect the encoder, use a FROHE 300/500 V shielded cable (3 x 0.5 mm²).
BUS cable table
We recommend using a FROR 2 x 0.5 mm cable, maximum 50 m in length from the control board.
Single branch length (m) max. 50 m
BUS cable 2 x 0.5 mm²
The total length of all branches can be a maximum of 150 m.
The cable cannot be shielded.
Page 9- Manual FA01412-EN - 01/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
INSTALLATION
Preparing the control panel
Page 10 - Manual FA01412-EN - 01/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Fastening the control panel
DIN rail
242
125
==
Standard
296
210