1
CHPPR2
2 Channel Prog
User Instructions
rammer
The latest ESP product manuals
can be found on-line:
Features:1
Operation Guide:
2
CHPPR2 is a two channel programmer, designed for separate
control of your heating and stored hot water. The heating and hot
water programs are independent of each other, giving you the
opportunity to save money and control your heating in the most
energy saving manner possible.
24 hour, 5/2 day and 7 day selectable
2 or 3 ON/OFF periods selectable
1,2 or 3 hour boost
Advance to next programmed event
Automatic Summer/Winter time change
Factory set time & date
Program options - ON, OFF, All day or Auto
Large and clear to read illuminated display
With/without service interval functionality
Suitable for pumped heating systems
Standard wall plate - simple plug in and replace
2.1
Open the front cover to show the hidden panel (as Fig. 1), and
complete all the settings as per below operation guide.
2.2 Configuration:
When setting time, date or changing programme times the first
screen displayed indicates the configuration as set up by the
installer. (See ‘Setting The Time section).
The 24 hour, or 5 day/2day, or 7 day programming option as set up
by the installer can also be verified at this stage by how the Monday
to Sunday indicators are displayed.
140mm
88.6mm
A M
P M
ON OFF
2 31
DATE
ADV
ON OFF
AUTO
ALL DAY
ADV
ON OFF
AUTO
ALL DAY
+ 1 H R
+ 2 H R
+ 3 H R
+ 1 H R
+ 2 H R
+ 3 H R
<6>
+HR
ADV
+HR
ADV
COPY
DAY
SET
-
NEXT
+
RESET
ON
OFF
AUTO
ALL DAY
CHPPR2
CU R R E N T SE TTINGS
Pr
ess
SETin tur
n to
show
product
Configuratio
n
(Setby youri
nstaller)Time
Date
Pr
ogr
am t
im es f
oreachchannelNorma
ldisplay
(Press+/-
toadj
ust,
NEX T
to
scr
olldate
or
prog
ram
times,
DAYtoscr
ollprogramda
ys&
CO P Y
to
cop
y
pr
ogram s
intonextd
ay)
M O DE SETTI
NG
Pr
ess
M ode buttonto
select
operating m ode for
a
channel
AU TO - O per
ate to
the setprogr
ams
O N -ContinuouslyON
O FF -
C ontinuously
OFF
ALL D A Y -On once bet
ween fir
stON andla
st
OFF
AD V A N C E (
AU TO /ALLDAY MODES)
Pr
ess
ADVtoswitch a channel
O N or
O FF temporarily
untilthe next
program m e time
US ING +HR
(NO T
IN O N M O DE)
Pr
ess
+HRto sel
ect1,2or3 H o
urs.
WhenO FF -wil
lboostf
orthetim e
WhenO N -will
extend curr
entprogrambyti
me
Eli
te
Securi
ty
Pr
oduc
ts
Uni
t7,Target
Par
k,
Shaw b an k R d ,
L akes
ide
,
Red ditch,B98 8YN
Tel
eph one:
01527 5151 50
Fax:
01527 5151
43
Email
:
info@esp uk .c
om
Web:
w w w.es
puk.com
<4>
<3>
<2>
<1>
<5>
Fig.1
Configuration Display
2 ON / OFF Pumped System 2 PU
3 ON / OFF Pumped System 3 PU
Times for Central Heating and Hot Water
can be independently set.
2 ON / OFF Gravity System 2 Gr
3 ON / OFF Gravity System
Programming Option Mon to Sun lndicators flash
3 Gr
7 DAY
5 / 2 DAY
24 HOUR
Mon to sun individually shown
Mon to Fri together then Sat & Sun together
Mon to sun together shown
2.6 Setting the Time:
A M
ON
ALL DAY
A M
Fig.2
Fig.3
Fig.4
If the unit is installed as a 24 hour programmer, the built in
programme will be the same for each day (i.e. Sat-Sun be same as
Mon-Fri above).
2.4 Factory Programme Settings:
2.3 Built in Programme:
For convenience, the programmer has a built in programme which
will be satisfactory for many people, but which can be changed
very easily (see section CHANGING PROGRAMME TIMES). Once
the unit is powered up this built in programme will run.
If the user changes from the built in programme and wishes to
return to it, then pressing the reset button with a non metallic
pointed tool will return the unit to the built in / default programme.
2.5 Selecting Operating Mode:
NOTE: Every time the reset is pressed, the time and date
must be set again.See the sections ‘Setting The Time &
Setting The Date’.


1.Press the SET button once. The configu-
ration setting will appear on the screen(
see Fig.2).
2. Press the SET button again. The clock
icon [1] on the screen will flash(See Fig 3).
3. Press the +/- buttons to adjust the time.
Time will change quicker if pressed
continually.
4. Press SET once to move on to setting
the DATE or press multiple times to return
to RUN mode(Fig. 4).
1st ON
2 PU & 2 Gr Mon - Fri Sat - Sun
1st OFF
-
-
2nd ON
2nd OFF
1st ON
1st OFF
2nd ON
2nd OFF
3rd ON
3rd OFF
6:00am
8:30am
12:00 noon
12:00 noon
4:30 pm
10:30 pm
7:00am
9:00am
12:00 noon
12:00 noon
4:30 pm
11:30 pm
3 PU & 3Gr
ON
OFF
AUTO
ALL DAY
ON
AUTO
Central Heating and Hot Water is ON
continuously
ALL
DAY
OFF
Central Heating and Hot Water will be switched
Central Heating and Hot Water will be switched
ON only once each day between the first ON
time and last OFF time
Central Heating and Hot Water is OFF continuously
ON or OFF as programmed
You can review or edit the date you have set
just by pressing NEXT button again and
repeating the sequence above. To confirm
the date and move on to PROGRAM mode
press SET button once or press SET button
multiple times to return to RUN mode.
2.7 Setting the Date:
Press SET button until tap icon [3] flashes in the display and 1 ON
[4] appears. This indicates the time shown on the display is the first
ON time of hot water(see Fig. 10) and proceed in same manner as
‘To change the Central Heating Times’ above.
2.8 Change Central Heating Times:
2.9 Change Hot Water Times:
DATE
DATE
DATE
Fig.6
Fig.5
Fig.7
If the unit is installed as a 7 day programmer, the initial programme
displayed will be for Monday.You can go to any date of the week by
pressing the DAY button repeatedly.
The ON/OFF times can be changed for each day as described
above in the section “CHANGING PROGRAMME TIMES”.
If you press the COPY button, the current programme will be
copied onto the next day.
If the unit is installed as a 5 day/2 day programmer, the initial
programme displayed will be for Monday to Friday.
Pressing the DAY button will take you to the programme for Satur-
day and Sunday.
The ON/OFF times can be changed for each day group as
described above in the section “CHANGING PROGRAMME
TIMES”.
7 Day Programmer Option:
5/2 Day Programmer Option:
The built in programme can easily be changed to better suit your
lifestyle.
NOTE: Programming is in 10 minute segments.
Press SET button until radiator icon [3] flashes in the display and
1 ON [4] appears.This indicates the time shown on the display is
the first ON time(see Fig.8).
By pressing the +/- buttons you can alter the ON time to the time
you want.
Press NEXT button, display will now show 1 OFF [4].
By pressing the +/- buttons you can alter the OFF time to the time
you want(see Fig.9).
Press NEXT button to access remaining ON/OFF periods and
alter in same manner as above.
To return to RUN mode, press the SET button until the display
return to run mode(Fig.4)
NOTE: it is not possible to copy Sunday to Monday.

1.Press the SET button until the Y:XX icon
(year)appears and the D(DATE)icon [2]
flashes(see Fig.5).
2.Press the +/- button to set the year.
3.Press NEXT button. M:XX appears(month
)(see Fig.6).
4.Press +/- button to set month.
5.Press NEXT button. D:XX appears(Day)(
see Fig.7).
6.Press +/- button to set day.
P M
ON1
Fig.10
A M
ON
1
A M
OFF
1
Fig.8 Fig.9
If the unit is installed as a 24 hour programmer, the built in
programme will be the same for each day.
The COPY & DAY buttons have no affect if installed as a 24 hour
programmer.
The unit will automatically return to normal running mode if a period
of 30 seconds passes without any buttons being pressed.
Programming past midnight is NOT allowed. To overcome this the
program needs to be split in two parts from midnight as per
example-
Desired program period - on 10:00pm off 7:00am
make Prog 1 - on 12:00am off 7:00am
make Prog 2 - on 10:00pm off 12:00am
2.10 Programming Notes:
If you press COPY button, the current programme will be copied
onto the next day group.
24 Hour Programmer Option:
The ADVANCE function allows the user to move to the next ON or
OFF programme for a “one off” event, without having to change the
programme or change the operating mode.
As a safety feature, after reset the unit will be in OFF operating
mode. Reselect your required operating mode.
Press the Central Heating channel ADV button. This will turn the
Central heating ON if it is in an OFF period and OFF if it is in an ON
period. It will stay in this state until either ADV button is pressed
again, or until a programmed ON/OFF period commences. The
word ADV [5] will appear in the left hand of the LCD.
Press the Hot Water channel ADV button. This will turn the Hot
Water ON if it is in an OFF period and OFF if it is in an ON period.
It will stay in this state until either ADV button is pressed again, or
until a programmed ON/OFF period commences. The word ADV
[5] will appear in the tleft of the LCD.
Warning:The ADVANCE function is only available when
programme is in AUTO or ALL DAY operating modes.

2.12 Using Advance:
To Advance Central Heating:
To Advance Hot Water:
Press the reset button with a non-metallic pointed tool to restore
the built in programme.As well as restoring the built in programme,
it also resets the time to 12:00pm and the date to 01/01/2020.
Initially the display shows all segments lit for a few seconds, but
then will show the current configuration. See ‘Setting The Time’
section to continue.
2.11 Reset:
2
Health & Safety
Regulations.
proceeding.
may be subject to change without prior notice.
Health & Safety
This unit must be installed by a suitably qualified person in accordance with the latest IEE Wiring
Regulations.
Isolate mains supply before commencing installation. Please read all installation instructions before
proceeding.
Example circuit diagrams for typical installations are shown. These diagrams are schematic and should
be used as a guide only. Please ensure that all installations comply with the current IEE regulations. For
reasons of space and clarity not every system has been included and the diagrams have been simplified,
for instance some Earth connections have been omitted. Other control components shown in the
diagrams i.e. Valves, Room Stats etc. are general representations only. However, the wiring detail can
be applied to the corresponding models of most manufacturers.
Your product is not user serviceable. Do not dismantle this product.
Due to our policy of continuous product improvement and development, the specifications in this guide
may be subject to change without prior notice.
Elite Security Products
Unit 7, Target Park, Shawbank Road,
Lakeside, Redditch, B98 8YN
Tel: 01527 515150
Fax: 01527 515143
Email: [email protected]
Web: www.espuk.com
If the Central heating operating mode is OFF, then it will switch on
for the extra hours selected. If the Central heating mode is AUTO
or ALL DAY, then during an OFF period,it will switch on for the
extra hours selected. If during an ON period, then it will temporarily
extend that programme by the number of hours selected.
Warning: The +HOUR function is only available when
programme is in AUTO,ALL DAY or OFF operating
modes.

Warning: The +HOUR function is only available when
programme is in AUTO,ALL DAY or OFF operating modes.

Press the Central Heating channel +HR button to make the desired
selection with one,two or three hours extra heating [6] and cancel
options offered.
2.13 Using +HR Boost:
For +Hr Central Heating:
Press the Hot Water channel +HR button to make the desired selec-
tion with one, two or three hours extra heating [6] and cancel options
offered.
For +Hr Hot Water:
A visual warning message 15, rUn, SEr, dUE indicates the
installer has set the programmer for a Partial Shutdown and your
heating/hot water will operate for a random15 minute portion of
each programmed hour only Therefore, to ensure your comfort
level is maintained, it is important to respond to any requests for a
gas safety check/boiler service appointment and to keep to the
appointment. Contact details for the installer/landlord may be
shown on a Service Contact label affixed to the product. The
installer will cancel or reset the Service Interval Timer as part of the
safety check/ boiler service.
2.16 Service Interval Function Setting:
If you are a tenant, under The Gas Safety (Installation & Use)
Regulations 1998, your private landlord, local authority or hous-
ing association must carry out a 12 monthly gas safety check to
make sure gas fittings and appliances are safe to use.
2.15 Power Interruption :
In the event of a mains supply failure, the screen will go blank, but
the programmer continues to keep the time and retain your stored
programme.
When power is restored, if there has been no change to the rear
DIP switch, the programmer returns to its expected operating
condition.
If the configuration setting on the rear DIP switch has been altered
during the power interruption, the screen will initially show the new
configuration. And the appropriate factory default programme (see
BUILT IN PROGRAMME section) will be installed.
Press SET button to return to RUN mode.
The display backlight will also flash on and off from 7 days prior to
the boiler service due date. During this warning period, the
programmer will continue to operate normally and you have full
access to all its features.
If the boiler is not serviced within the 28 days then the programmer
will operate only according to one of two settings (selected by the
installer on installation). All buttons will be disabled. The display
backlight will continue to flash.
A visual warning message OFF, SEr, dUE indicates the installer
has set the programmer for a Total Shutdown and your heating/hot
water will no longer operate.
If set by the installer, 28 days prior to the boiler service due date, a
rotating visual warning message SEr, dUE, dXX will remind you
that a service is due (XX shows the number of days remaining in
the warning period).
Warning: The Holiday function is only available in AUTO,
ALL DAY or ON operating modes.

The number of days will decrease at midnight each day.
The +HR boost override can be used during a holiday period.
1. Press & Hold DAY button for 4 seconds to enter the holiday
function , d:01 flashes(see Fig. 12).
2. Press +/- button to set the holiday days.
3. Press DAY button to activate.
4. Press & Hold DAY button for 4 seconds to cancel a holiday
period.
2.14 Holiday Mode:
The Holiday function allows the user to turn all channels to the OFF
operating mode, for a settable amount of days from 01-99 days.
During this function, a suitcase icon will be displayed(see Fig 11).

If the Hot Water operating mode is OFF, then it will switch on for
the extra hours selected.
If the Hot Water mode is AUTO or ALL DAY, then during an OFF
period, it will switch on for the extra hours selected. If during an ON
period, then it will temporarily extend that programme by the
number of hours selected.
NOTE: If the programmer is in the OFF mode and then +HR
button is pressed (+1 HR, +2 HR, or + 3 HR) and the
resulting time of the boost overlaps a START / ON time in
the AUTO mode programme memory,then the boost will
disengage. If this happens simply press +HR button again
and then it will temporarily extend that programme by the
number of hours selected.
Fig.12
P M
OFF
Fig.11
Date Issued
J20 A30-CHPPR2-01-2 Rev.1
Issue No Description

Other Sangamo Motherboard manuals

Sangamo CHPPR3 User manual

Sangamo

Sangamo CHPPR3 User manual

Sangamo CHPPR1 User manual

Sangamo

Sangamo CHPPR1 User manual

Sangamo Choice PR3n User manual

Sangamo

Sangamo Choice PR3n User manual

Sangamo Choice PR1n User manual

Sangamo

Sangamo Choice PR1n User manual

Sangamo Choice PR2n User manual

Sangamo

Sangamo Choice PR2n User manual

Popular Motherboard manuals by other brands

Gigabyte GA-B150M-D3H-GSM user manual

Gigabyte

Gigabyte GA-B150M-D3H-GSM user manual

Biostar Hi-Fi Z87S2 Setup manual

Biostar

Biostar Hi-Fi Z87S2 Setup manual

Asus P4V800D-X user guide

Asus

Asus P4V800D-X user guide

GIGA-BYTE TECHNOLOGY A520 AORUS ELITE user manual

GIGA-BYTE TECHNOLOGY

GIGA-BYTE TECHNOLOGY A520 AORUS ELITE user manual

MSI Z87M-G43 Series user manual

MSI

MSI Z87M-G43 Series user manual

LeddarTech LeddarEngine LCA3 user guide

LeddarTech

LeddarTech LeddarEngine LCA3 user guide

Asus Pro Q670M-C quick start guide

Asus

Asus Pro Q670M-C quick start guide

Unicorn SBC-210 user manual

Unicorn

Unicorn SBC-210 user manual

Gigabyte GA-945PL-S3E user manual

Gigabyte

Gigabyte GA-945PL-S3E user manual

Intel BLKD410PTL Product guide

Intel

Intel BLKD410PTL Product guide

ADLINK Technology NuPRO-865 user manual

ADLINK Technology

ADLINK Technology NuPRO-865 user manual

LevelOne LXD970A user guide

LevelOne

LevelOne LXD970A user guide

AXIOMTEK SBC84833 Series user manual

AXIOMTEK

AXIOMTEK SBC84833 Series user manual

MSI K8N Neo Platinum user guide

MSI

MSI K8N Neo Platinum user guide

Asus PRIME H770-PLUS D4 manual

Asus

Asus PRIME H770-PLUS D4 manual

Asus M5A88-M EVO user manual

Asus

Asus M5A88-M EVO user manual

Asus TUF B450-PLUS GAMING manual

Asus

Asus TUF B450-PLUS GAMING manual

Texas Instruments SN6507DGQEVM user guide

Texas Instruments

Texas Instruments SN6507DGQEVM user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.