Satel Proof-TR4+ User manual

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
SATEL Proof-TR4+
SATEL Proof-TR9
SATEL Proof-R4+
Radio Modem
User Guide

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
2
TABLE OF CONTENTS
TABLE OF CONTENTS ........................................................................................ 2
IMPORTANT NOTICE ......................................................................................... 4
RESTRICTIONS ON USE –SATEL PROOF-TR4+.................................................. 5
RESTRICTIONS ON USE –SATEL PROOF-TR9 .................................................... 6
PRODUCT CONFORMITY.................................................................................... 8
WARRANTY AND SAFETY INSTRUCTIONS ......................................................... 9
1DESCRIPTION OF THE PRODUCT................................................................ 10
2SATEL PROOF-TR4+/R4+ TECHNICAL SPECIFICATIONS ............................ 11
3SATEL PROOF-TR9 TECHNICAL SPECIFICATIONS ....................................... 14
4CONFIGURATION ...................................................................................... 15
4.1 Configuration Manager software ........................................................ 15
4.2 SL commands ....................................................................................... 16
5MODEM SETTINGS ..................................................................................... 18
5.1 Default settings of SATEL Proof-TR4+.................................................. 18
5.2 Default settings of SATEL Proof-TR9 .................................................... 20
6CONNECTORS ............................................................................................ 21
6.1 Antenna connector ............................................................................... 21
6.2 Power/Data connector ......................................................................... 21
7SERIAL PORT .............................................................................................. 22
7.1 Pause length ........................................................................................ 22
7.2 Data buffering...................................................................................... 23
8RF INTERFACE............................................................................................. 24

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
3
8.1 Transmitter........................................................................................... 24
8.2 Receiver................................................................................................ 25
8.3 Encryption............................................................................................. 25
8.4 Radio state ........................................................................................... 26
8.5 Priority RX/TX....................................................................................... 27
8.6 Forward Error Correction (FEC) ............................................................ 27
8.7 Error checking ...................................................................................... 27
8.8 TX delay................................................................................................ 28
8.9 Add RSSI to data .................................................................................. 28
8.10 Separate RX/TX-frequencies................................................................ 28
8.11 Call Sign ............................................................................................... 29
8.12 Channel list .......................................................................................... 29
8.13 Repeater mode..................................................................................... 30
8.14 Radio compatibility modes .................................................................. 31
9MECHANICAL DIMENSIONS....................................................................... 35
10 INSTALLATION ........................................................................................... 36
11 GROUNDING ............................................................................................. 37
12 ACCESSORIES ............................................................................................. 38
13 PROPOSALS FOR MORE RELIABLE RADIO LINK......................................... 39
14 APPENDIX A –TRANSMISSION DELAYS..................................................... 40

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
4
IMPORTANT NOTICE
All rights to this manual are owned solely by SATEL Oy (referred to in this user guide as SATEL).
All rights reserved. The copying of this manual (without the written permission from the owner)
by printing, copying, recording or by any other means, or the full or partial translation of the
manual to any other language, including all programming languages, using any electrical,
mechanical, magnetic, optical, manual or other methods or devices is forbidden.
SATEL reserves the right to change the technical specifications or functions of its products, or to
discontinue the manufacture of any of its products or to discontinue the support of any of its
products, without any written announcement and urges its customers to ensure, that the
information at their disposal is valid.
SATEL software and programs are delivered ”as is”. The manufacturer does not grant any kind
of warranty including guarantees on suitability and applicability to a certain application. Under
no circumstances is the manufacturer or the developer of a program responsible for any
possible damages caused by the use of a program. The names of the programs as well as all
copyrights relating to the programs are the sole property of SATEL. Any transfer, licensing to a
third party, leasing, renting, transportation, copying, editing, translating, modifying into
another programming language or reverse engineering for any intent is forbidden without the
written consent of SATEL.
SATEL PRODUCTS HAVE NOT BEEN DESIGNED, INTENDED NOR INSPECTED TO BE USED IN ANY
LIFE SUPPORT RELATED DEVICE OR SYSTEM RELATED FUNCTION NOR AS A PART OF ANY OTHER
CRITICAL SYSTEM AND ARE GRANTED NO FUNCTIONAL WARRANTY IF THEY ARE USED IN ANY OF
THE APPLICATIONS MENTIONED.
Salo, FINLAND 2022

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
5
RESTRICTIONS ON USE – SATEL Proof-TR4+
SATEL Proof-TR4+ and SATEL Proof-R4+ radio modems have been designed to operate on
403-473 MHz frequency band, the exact use of which differs from one region and/or country to
another. The user of a radio modem must take care that the said device is not operated without
the permission of the local authorities on frequencies other than those specifically reserved and
intended for use without a specific permit.
SATEL Proof-TR4+/R4+ are allowed to be used in the following countries, either on license free
channels or on channels where the operation requires a license. More detailed information is
available at the local frequency management authority.
Countries: AT, AU, BE, BG, BR, CA, CH, CY, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HU, HR, IE, IS, IT, LT,
LU, LV, MT, NL, NO, PL, PT, RO, SE, SI, SK, TR, US
Antenna Gain [dBi]
Separation distance [cm]
0
23
4
36
6
45
8
56
10
71
12
89
14
112
WARNING - RF Exposure!
To comply with CE, FCC and IC RF exposure compliance requirements
the maximum antenna gain is 14 dBi and the minimum separation
distance (listed in the table below) must be maintained between the
antenna of SATEL Proof-TR4+ and all persons.
Modification warning statement
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
WARNING! Users of SATEL Proof-TR4+ radio modem in North America should be aware, that
due to the allocation of the frequency band 406.0 –406.1 MHz for government use only, the
use of radio transceiver on this frequency band without a proper permit is strictly forbidden.

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
6
RESTRICTIONS ON USE – SATEL Proof-TR9
SATEL Proof-TR9 radio modem has been designed to operate on 902-928 MHz frequency band,
the exact use of which differs from one region and/or country to another. The user of a radio
modem must take care that the said device is not operated without the permission of the local
authorities on frequencies other than those specifically reserved and intended for use without a
specific permit.
SATEL Proof-TR9 is allowed to be used in the following countries. More detailed information is
available at the local frequency management authority.
Countries: AU, BR, CA, US
The frequency band in USA and Canada is 902 –928 MHz. In Australia and Brazil the frequency
band is limited to 915 –928 MHz due to the local regulations.
This radio transmitter 2422A-SATELTA31 has been approved by Industry Canada to operate with
the antenna types listed below with the maximum permissible gain indicated. Antenna types
not included in this list, having a gain greater than the maximum gain indicated for that type,
are strictly prohibited for use with this device.
Antenna type
Manufacturer
Antenna model
Maximum gain (dBi)
Omnidirectional
Oy CompleTech Ltd
CA915H
5
Directional (yagi)
Oy CompleTech Ltd
CA930Y
6
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation,
Science and Economic Development Canada’s licence-exempt RSS(s) and part 15 of the FCC
Rules. Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause
undesired operation of the device.
WARNING - RF Exposure!
To satisfy FCC and ISED RF exposure requirements for mobile
transmitting devices, a separation distance of 25 cm or more should be
maintained between antenna of this device and persons during device
operation. To ensure compliance, operations at closer than this distance
is not recommended. The antenna used for this transmitter must not be
co-located in conjunction with any other antenna or transmitter. FCC
regulations allow up to 36 dBm equivalent isotropically radiated power
(EIRP). Therefore, the sum of the transmitted power (in dBm), the cabling
loss and the antenna gain cannot exceed 36 dBm.
df

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
7
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux
CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
Modification warning statement
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
8
PRODUCT CONFORMITY
Hereby, SATEL Oy declares that SATEL Proof-TR4+ and SATEL Proof-R4+ radio modems are in
compliance with the essential requirements (radio performance, electromagnetic compatibility
and electrical safety) and other relevant provisions of Directive 2014/53/EU. Therefore, the
equipment is labelled with CE-marking.

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
9
WARRANTY AND SAFETY INSTRUCTIONS
Read these safety instructions carefully before using the product:
-Warranty will be void, if the product is used in any way that is in contradiction with the
instructions given in this manual, or if the radio modem housing has been opened or tampered
with.
-The radio modem is only to be operated at frequencies allocated by local authorities, and
without exceeding the given maximum allowed output power ratings. SATEL and its distributors
are not responsible, if any products manufactured by it are used in unlawful ways.
-The devices mentioned in this manual are to be used only according to the instructions
described in this manual. Faultless and safe operation of the devices can be guaranteed only if
the transport, storage, operation and handling of the devices is appropriate. This also applies to
the maintenance of the products.
-To prevent damage both the radio modem and any terminal devices must always be switched
OFF before connecting or disconnecting the serial connection cable. It should be ascertained
that different devices used have the same ground potential. Before connecting any power
cables, the output voltage of the power supply should be checked.
- Any radio link can be susceptible to external interference and signal degradation by its nature.
Because of that, the effects of possible interference mechanisms and the sufficient back-up
schemes must be taken into account in the system design of the critical applications.
NOTE!
When selecting a suitable location for the radio modem it must be ensured that no water can
get into the radio modem under any conditions. Direct sunlight is also to be avoided. It is not
recommendable to install the radio modem on a strongly vibrating surface. Suitable
dampening and/or isolation materials should be used in cases where the installation surface
will be subjected to vibration.

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
10
1DESCRIPTION OF THE PRODUCT
SATEL Proof-TR4+ is a UHF (403…473 MHz frequency band) radio transceiver modem that
provides a transparent data link with many SATEL serial radios and with many other
manufacturers’ radio modems.
SATEL Proof-R4+ is the receive-only variant of SATEL Proof-TR4+.
SATEL Proof-TR9 is a UHF (902…928 MHz license free ISM band) radio transceiver modem that
provides a transparent data link with many SATEL serial radios and with many other
manufacturers’ radio modems.
SATEL Proof radio modems can be connected to various communication devices via RS-232
serial data interface. The Deutsch DT series connector provides the pins for data lines (TD, RD)
and power supply (+7…+27.5 VDC). Antenna is connected to the female TNC connector.
SATEL Proof-TR4+/R4+/TR9 are heavy-duty radio modems that meet the requirements of
machine control, smart farming and marine applications. They are built to last dirt, vibration,
sand, dust, liquids and lightning:
•SATEL Proof radio modems have a profound electrical protection - both the power and
data lines as well as the antenna interface are surge protected.
•SATEL Proof radio modems are IP67/IP69K rated against ingress of dust and high
temperature, high pressure water. See more detailed description on chapter “Technical
Specifications”
•Additionally, SATEL Proof radio modems provide RF filtering on GNSS frequencies to
work seamlessly in GNSS positioning applications.
Power/Data
Connector
Deutsch
DT04-6P-CL09
1 POWER
2 not connected
3 not connected
4 TD
5 RD
6 GND
SATEL Proof–TR4+ / SATEL Proof–TR9
Block Diagram
Protector / Power
Conditioner Board
TR4+ or TR9
Radio Module
RS232
Motherboard
SPSU
Surge
Protector ESD Polarity OverVolt
Surge
Protector
Band
reject
filter
Antenna
Connector
TNC (f)
RF
IP67/IP69K classified aluminium enclosure

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
11
2SATEL Proof-TR4+/R4+ TECHNICAL SPECIFICATIONS
SATEL Proof-TR4+/R4+ comply with the following international standards:
•EN 300 113
•EN 301 489
•IEC 62368-1 (safety)
•FCC CFR47 Part 90
•FCC CFR47 Part 15
SATEL Proof-TR4+/R4+ TECHNICAL SPECIFICATIONS Values are subject to change without a notice
Parameter
RECEIVER
(SATEL Proof-TR4+/R4+)
TRANSMITTER
(SATEL Proof-TR4+)
Notes
Frequency Range
403 ... 473 MHz
Tuning range
70 MHz
Minimum RF Frequency
Step
6.25 kHz @12.5 or 25 kHz channel spacing
10 kHz @ 20kHz channel spacing
Channel Bandwidth
12.5 kHz / 25 kHz
Programmable
Channel Spacing
12.5, 20 (uses 12.5kHz channel width), 25 kHz
Programmable
Frequency Stability
<1 kHz
Maximum Continuous
Receiver Input Power
without Damage
+3 dBm
Maximum Receiver Input
Power without
Transmission Errors
-10 dBm
FEC ON
Sensitivity
-112 dBm @ 25 kHz
-114 dBm @12.5 kHz
SATEL-4FSK (FEC ON)
-110 dBm @ 25 kHz
-112 dBm @12.5 kHz
SATEL-8FSK (FEC ON)
-101 dBm @ 25 kHz
-103 dBm @12.5 kHz
SATEL-16FSK (FEC ON)
Blocking
-17 dBm @ 25 kHz
-20 dBm @ 12.5 kHz
SATEL-4FSK (FEC ON)
-18 dBm @ 25 kHz
-17 dBm @ 12.5 kHz
SATEL-8FSK (FEC ON)
-29 dBm @ 25 kHz
-25 dBm @ 12.5 kHz
SATEL-16FSK (FEC ON)
Intermodulation
Attenuation
> 61 dB @ 25 kHz
> 61 @ 12.5 kHz
FEC ON
CO-Channel Rejection
> -11 dB @ 25 kHz
> -10 dB @ 12.5 kHz
FEC ON

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
12
Adjacent Channel
Selectivity
-33 dBm @ 25 kHz
-36 dBm @ 12.5 kHz
SATEL-4FSK (FEC ON)
-34 dBm @ 25 kHz
-34 dBm @ 12.5 kHz
SATEL-8FSK (FEC ON)
-43 dBm @ 25 kHz
-40 dBm @ 12.5 kHz
SATEL-16FSK (FEC ON)
Spurious Rejection
> 67 dB
FEC ON
Typical Power
Consumption
RX
12 V: 1.32 W
TX
12 V: 5.8 W @ 1 W RF
Transmitter Power
(programmable)
0.01, 0.02, 0.05, 0.1, 0.2,
0.5, 1 W
TX-mode, 50Ωload
Adjacent Channel Power
acc. to EN 300 113
TX-mode
Transient Adjacent
Channel Power
acc. to EN 300 113
TX-mode
Carrier power stability
< ±1.5 dB
Communication Mode
Half-Duplex
Data speed of Radio
Interface
4FSK FEC OFF:
19200 bps (25 kHz) / 9600 bps (12.5 kHz)
4FSK FEC ON:
14400 bps (25 kHz) / 7200 bps (12.5 kHz)
8FSK FEC OFF:
28800 bps (25 kHz) / 14400 bps (12.5 kHz)
8FSK FEC ON:
19200 bps (25 kHz) / 9600 bps (12.5 kHz)
16FSK FEC ON:
28800 bps (25 kHz) / 14400 bps (12.5 kHz)
Air Interface Encryption
AES128 (AES256 optionally)
(product variants without encryption available)
Programmable
Modulation
4FSK, 8FSK, 16FSK, GMSK
Serial Data Interface
RS-232 asynchronous data 1200 –115200 bps
Operating Voltage
+7 … +27.5 Vdc (+15%/-20%)
Typical Power
Consumption
RX 1.32 W (12 V)
TX 5.8 W (12 V) @ 1 W transmitter power
Temperature Ranges
-30 °C ... +65 °C Operational
-40 °C … +75 C Absolute min / max
-25 °C ... +55 °C Complies with standards
-40 °C … +85 C Storage
Antenna Connector
50 , TNC female
Interface Connector
Deutsch DT04-6P-CL09
Housing
Shielded / bare PCB inside a metal housing
Size L x W x H
174 x 95 x 46 mm
Mechanical standards
IEC60068-2-32,
ISO9022-36-08, ISO9022-31-06, ISO9022-33-06
Weight
<500 g

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
13
IP rating
IP67/IP69K
See Note 1 below
ESD-failure threshold
8 kV contact, 15 kV air discharge
Immunity
>10 V/m
Vibration
>20 G (20 Hz…2 kHz sinusoidal/random)
Note 1: IP67/IP69K rating of the device requires the mating connector to be correctly assembled
and connected into the device’s Deutsch connector. See details from the connector
manufacturer’s datasheet.

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
14
3SATEL Proof-TR9 TECHNICAL SPECIFICATIONS
SATEL Proof-TR9 complies with the following international standards:
•FCC CFR47Part 15
•EN 301 489-1, EN 301 489-5
•IEC 62368-1 (safety)
•IC RSS-247, ICC RSS-Gen
SATEL Proof-TR9 TECHNICAL SPECIFICATIONS Values are subject to change without a notice
Frequency Range
902-928 MHz
Spreading Method
Frequency Hopping
Occupied Bandwidth
230 kHz
Frequency Stability
<1 kHz
Maximum Receiver Input Power
without Transmission Errors
-3 dBm
Sensitivity
typ. -109 dBm for BER 10-4
Transmitter Power
0.01, 0.02, 0.5, 0.1, 0.2, 0.5, 1 W
Carrier power stability
< ±1.5 dB
Modulation Method
2-GFSK
Hopping Bands
7, user selectable
Hopping Patterns
15 per band, 105 total, user selectable
Hopping Channels
50-112, user selectable
Frequency Zones
16 Zones, 7 Channels per Zone
Serial Data Interface
RS-232 asynchronous data 9600 –115200 bps
Operating Voltage
+7 … +27.5 Vdc (+15%/-20%)
Typical Power Consumption
RX 1.32 W (12 V)
TX 5.8 W (12 V) @ 1 W transmitter power
Temperature Ranges
-30 °C ... +65 °C Operational
-40 °C … +75 C Absolute min / max
-25 °C ... +55 °C Complies with standards
-40 °C … +85 C Storage
Antenna Connector
50 , TNC female
Interface Connector
Deutsch DT04-6P-CL09
Housing
Shielded / bare PCB inside a metal housing
Size L x W x H
174 x 95 x 46 mm
Mechanical Standards
IEC60068-2-32, ISO9022-36-08, ISO9022-31-06, ISO9022-33-06
Weight
<500 g
IP rating
IP67/IP69K (see Note 1 below)
ESD-failure threshold
8 kV contact, 15 kV air discharge
Immunity
10 V/m
Vibration
>20 G (20 Hz…2 kHz sinusoidal/random)
Note 1: IP67/IP69K rating of the device requires the mating connector to be correctly assembled
and connected into the device’s Deutsch connector. See details from the connector
manufacturer’s datasheet.

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
15
4CONFIGURATION
The configuration of SATEL Proof radio modem can be modified via the serial interface by using
SATEL Configuration Manager software or specific SL commands.
4.1 Configuration Manager software
This easy-to-use software for Windows provides access to the user settings, including the
channel list editor for creating the channel lists, and the functions for restoring the factory setup
and making firmware updates. The software is available from the dealers or at www.satel.com.
QuickStart
Preliminary settings:
1. Save the SATEL Configuration Manager files in the same
directory.
2. Connect the modem to the PC using a proper interface
cable.
3. Connect power to the modem. Before connecting,
check that you have correct supply voltage.
4. Open the SATEL Configuration Manager program. Check from the “Program Preferences”
tab, that you have selected correct COM-port number and that the serial port settings
match to the modem. Default settings are 115200 bps, 8 bit, none parity, 1 stop bit.
5. To establish connection between the modem and the PC, click the blue Connect tab. To
get the radio modem info, click blue Read Settings tab.
6. Check the settings and modify if needed.
7. Store settings to a modem using “Write settings” –button.
8. More information about Configuration Manager can be found from user guide.

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
16
4.2 SL commands
A terminal device can command or configure the radio modem via the serial data interface by
using SL commands (similar to AT commands in traditional wired modems) that are applicable
especially in cases where radio modems are to be integrated seamlessly inside a system behind
the integrator’s own user interface.
4.2.1 Command mode
Firmware provides the Command mode in which the data transfer is blocked, thus making the
use of SL commands easier without received data disrupting the interpretation of the SL
command responses. The command mode is activated by entering three successive plus
characters separated by a time delay greater than defined by Pause length setting:
<pause>+<pause>+<pause>+
The Command mode is terminated (and Data mode is activated) by entering three successive
minus characters:
<pause> - <pause> - <pause> -
The modem responds the above sequences with OK message.
Note. SL commands operate in the command mode independent from the value of SL
Commands mode setting.
4.2.2 Operation of SL commands
Depending on the active value of SL command mode setting, SL commands work in one of the
four operational modes:
•OFF
oSL commands work only in the Command mode but not in the Data mode
oCR/LF feature is OFF.
•ON
oSL commands are always ON –both in the Command mode and in the Data mode
oCR/LF feature is OFF
•ON-CR/LF
oSL commands are always ON –both in the Command mode and in the Data mode
oCR/LF feature is ON
•OFF-CR/LF
oSL commands work only in the Command mode
oCR/LF feature is ON
Note. Due to legacy reasons some SL command responses are terminated by CR character,
some not. CR/LF feature appends the combination of CR and LF characters to the end of
the response message (unless the message already ends with it), thus making the parser
design easier for system integrators.

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
17
4.2.3 Syntax of SL commands
An SL command is a one continuous string of specific characters, which is separated from other
data by pauses that are equal or greater than the time defined by Pause Length setting (default
value is 3 characters). The continuous here means that there are no pauses between the
adjacent characters inside the SL command on the serial line.
The syntax of an SL command is: SL<Command><CR><LF>, where:
<Command> is the actual character string defining the actual command.
<CR> is Carriage Return (ASCII character 13, 0x0d in hexadecimal)
<LF> is LineFeed (ASCII character 10, 0x0a in hexadecimal).
Note that the use of <CR> <LF> is optional but recommended.
The radio modem will acknowledge all commands by returning "OK" (command carried out or
accepted) or the requested value, or "ERROR" (command not carried out or interpreted as
erroneous) message.
If multiple SL commands are sent to the radio modem, the next command can be given after
receiving the response ("OK" or "ERROR") of the proceeding command. In addition, it is
recommended to implement a timeout to the terminal software for recovering the case when no
response is received from the radio modem.
SL commands are described in separate documentation, contact SATEL for more information.

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
18
5MODEM SETTINGS
5.1 Default settings of SATEL Proof-TR4+
The radio modem is delivered with the configuration below unless otherwise ordered.
DEFAULT VALUES OF THE ADJUSTABLE SETTINGS ( the user can change these settings later)
Setting
Default value
Range
Radio frequency
Operating TX frequency
438.000 MHz
Range: 403-473 MHz
Operating RX frequency
438.000 MHz
Range: 403-473 MHz
Reference Frequency
438.000 MHz
Range: 403-473 MHz
Channel Bandwidth
12.5 kHz / 25 kHz
Channel Spacing
12.5 kHz
12.5, 20 (uses 12.5kHz channel width), 25 kHz
Min. RF Frequency Step
6.25 kHz (10kHz @20kHz channel spacing)
Radio settings
TX Power
1000 mW
Range: 10, 20, 50, 100, 200, 500 or 1000 mW
Signal threshold
-115 dBm
- 80 … -118 dBm
TX-Start Delay
0 ms
0-65535 ms
Radio Compatibility
(Available set depends on
the factory configuration)
SATELLINE-3AS
SATELLINE-3AS
PacCrest-4FSK
PacCrest-GMSK
PacCrest-FST
TrimTalk450s(P)
TrimTalk450s(T)
SATELLINE-2ASxE (ask availability from SATEL)
SOUTH
SATEL-8FSK-1 (FEC OFF)
SATEL-8FSK-2 (FEC ON)
SATEL-16FSK-1 (FEC ON)
Addressing
RX Address
OFF
ON/OFF
TX Address
OFF
ON/OFF
Serial port
Data speed
115200 bps
1200 –115200 bps
Data bits
8
8
Parity bits
None
None, Even, Odd.
Stop bits
1
1

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
19
Handshaking
Handshaking lines apply to the DATA-port.
Pause length
3 bytes
3….255
Additional setup
Error correction, FEC
OFF
ON/OFF
Error check
OFF
OFF, CRC8Partial, CRC8Full, CRC16Full
Repeater Mode
OFF
ON/OFF
SL-commands
ON
ON/OFF
TX Delay
0
0 …. 65535 ms
Over-the-Air-Encryption
OFF
ON/OFF
Use Channel List
OFF
ON/OFF
Power Save Mode
OFF
ON/OFF
Add RSSI to Data
OFF
ON/OFF
Radio State
TX
TX/RX
Priority
TX
TX/RX

SATEL Proof-TR4+/R4+/TR9
User Guide, Version 2.2
20
5.2 Default settings of SATEL Proof-TR9
The radio modem is delivered with the configuration below unless otherwise ordered.
DEFAULT VALUES OF THE ADJUSTABLE SETTINGS (the user can change these settings later)
Operation Mode
Default value
Range
Point-to-Multipoint Slave
3
Set Baud Rate
Baud Rate
115200
Data Parity
0
Modbus RTU
0
RS232/485
0
Setup Port
3
TurnOffDelay/OnDelay
0/0
FlowControl
0
Radio Parameters
FreqKey
5
Hop Table Version
0
Hop Table Size
112
Hop Freq Offset
0
Frequency Zone
All 1s (Enabled)
Max Packet Size
8
Min Packet Size
9
Xmit Rate
1
RF Date Rate
3
RF Xmit Power
1000
Slave Security
0
RTS to CTS
0
Retry Timeout
255
Low Power Mode
0
High Noise
0
MCU Speed
0
Remote LED
0
Multipoint Parameters
Number of Repeaters
1
Master Packet Repeat
3
Max Slave Retry
9
Retry Odds
9
DTR Connect
0
Repeater Frequency
0
Network ID
255
Multimaster Sync
0
Slave/Repeater
0
Subnet ID
“Disabled”
This manual suits for next models
2
Table of contents
Other Satel Modem manuals