IntelliFlow 3 Liquid Installation Guide 7875-3000-100 Rev A1
• Store excess cable lengths with a minimum six-inch bend radius.
• Do not coil cables (introduces noise).
• Avoid high-temperature exposure (for example - the exhaust, exhaust manifold) when routing.
• Hand tighten connections only; do not use tools (overtighten).
Cable Connection Steps to IF3 Controller
1. Connect part C or part D (depending upon the use of a G4 or Bantam GPS) to
the CONTROLLER port of part I.
2. Connect part C or D to the respective G4’s or Bantam’s FLOW port.
3. Connect part E to part I’s POWER port.
4. With part E and part K, ensure part K is a) wired into the aircra’s power
supply and b) cockpit-mounted within easy reach of the pilot. (Install per pilot’s
preference.)
5. Connect part F’s MOTOR cable to Part I’s VALVE MOTOR port.
6. Ensure the bypass switch on part F is cockpit-mounted within easy reach of the
pilot. (Install per pilot’s preference.)
7. Connect part F to part B.
8. Connect part G to part I’s FLOW METER port.
9. Securely connect part N to part A.
10. Connect part G to part N.
11. Connect part H to part I’s TRIM/PRESSURE port.
12. Ensure the trim bump switch on part H is cockpit-mounted within easy reach
of the pilot. (Install per pilot’s preference.)
13. Connect part H’s BOOM SENSOR wires to part J. (Note: Part H’s PRESSURE
TRANSDUCER cable is optional. Use with optional part R.)
b) Horizontal Mounts Without Template
i) Use hardware from the pre-assembled rack mount system to attach horizontal mounting brackets
(Part O) to the CPU.
ii) Use parts Pa and Pb to attach vibration isolators (Part Pc) to horizontal mounting brackets.
iii) Place CPU in the desired location while heeding the above recommendations.
iv) Mark the fastener hole locations of the four vibration isolator feet. ere are eight holes at #28 drill bit
(0.140”).
v) Drill holes being careful not to cause damage.
vi) Use parts Pd, Pe, and Pf to attach vibration isolators (Part Pc) to approved structure.
3) CPU Horizontally Mounted Without Vibration Isolators
a) Horizontal Mounts With Template (PN 601-1317-000, Part T)
i) Place the template (Part T) in the desired location while heeding the above recommendations.
ii) Use the template to mark the fastener hole locations of the 4 fastener locations. ere are four holes at
#16 drill bit (0.177”).
iii) Drill holes being careful not to cause damage.
iv) Use hardware from the pre-assembled rack mount system to attach horizontal mounting brackets
(Part O) to the CPU.
v) Use locally sourced hardware to attach the CPU to approved structure.
b) Horizontal Mounts Without Template
i) Use hardware from the pre-assembled rack mount system to attach horizontal mounting brackets
(Part O) to the CPU.
ii) Place CPU in the desired location while heeding the above recommendations.
iii) Mark the fastener hole locations of the four fastener locations. ere are four holes at #16 drill bit
(0.177”).
iv) Drill holes being careful not to cause damage.
v) Use locally sourced hardware to attach the CPU to approved structure.
Part I: IF3 Controller