Satloc INTELLIFLOW 3 User manual

IntelliFlow 3 Liquid Installation Guide 1875-3000-100 Rev A1
LIQUID INSTALLATION GUIDE
875-3000-100 Rev A1
Overview: is installation guide lists all the parts in the
IntelliFlow 3 (IF3) liquid kits and provides instructions on how to install
the IF3 components, associated cables, and switches.
Read this manual thoroughly before beginning the installation.
If you have any questions, contact your local dealer or Satloc Customer Service.

IntelliFlow 3 Liquid Installation Guide 2875-3000-100 Rev A1
PRODUCT DESCRIPTION AND DETAILS
With the IntelliFlow 3™ (IF3) control system on board, the installed GPS, working with IF3, automatically controls
aerial spray rates. is produces an accurate constant ow rate or a variable rate based on prescription maps
(PMAPs) and/or 3rd party soware. e required ow rates can be pilot selected, or PMAPs can be created using
Satloc MapStar® desktop soware.
Enter desired rates through the GPS interface, and the IF3 system will regulate and maintain selected rates. Once
installed, the G4 or Bantam GPS controls the IntelliFlow 3™ system settings. Spray rates are automatically controlled
with an accurate constant ow rate or a variable rate based on application selections or prescription maps (PMAPs)
in the GPS system. Fine-tune applications through the rate bump feature for more precise applications.
e Satloc G4™ will switch between liquid and dry settings with ease. Control your Transland Hydraulic 5”, 7.5”, or
10” gate system inside the Satloc G4™ and IntelliFlow 3™ connections. e IntelliFlow 2™ control system comes with
a controller, associated cabling, and required unlocks. Liquid kits include a valve with a motor and a meter with a
magnetic sensor.
Features:
LiquidandDrycontroloptions
Regulateandmaintainselectedrates
Flowcontroloptionsin0.5”,1”1.5”,2”,and3”versions
Finetuneapplicationwithratebump
Displaypressureonscreenandlightbarwithoptionaltransducer
Liquid Applications Include:
Aerialagriculturalcropapplications
Forestryapplications
Demandingeradicationsuppressionsprayprogram
This system sprays precise patterns
using constant rate ow control,
thereby reducing:
Fuel
Flyingtime
Applicationcosts
Pilotfatigue

IntelliFlow 3 Liquid Installation Guide 3875-3000-100 Rev A1
SAFETY INFORMATION
Read and Follow Safety Messages
• In these instructions, you may see the heading and/or the safety alert symbol . ey indicate
a hazardous situation that, if not avoided, could result in death or serious injury. e safety messages provide
information to identify a hazard associated with potential injury.
• Read and understand this manual and all the warnings below before installing, operating, or performing maintenance
or service. FAILURE TO DO SO MAY CAUSE IRREVERSIBLE DAMAGE TO YOUR SYSTEM.
• Keep this manual and all related safety information with the manuals for your aircra.
Plan your installation by considering the following:
• Cable lengths
• Clearance space
• Power source
• Aircra structure
• Visibility
Consider using existing hardware and hardware locations. Avoid drilling holes that may damage other
equipment (such as structural frame members, electrical cables, or uid lines).
Do not obstruct the view of, or access to, other instruments or the ying visibility of the operator.
Do not allow anyone to operate without instruction.
For trouble-free operation and maintenance of your IF3 system, adhere to the following
recommendations.
• Avoid using IF3 in extreme environmental conditions (40-140°F is recommended operating
temperature range).
• Wash the hopper/boom system thoroughly and methodically aer spray sessions to avoid
gumming up the ow meter unit.
TABLE OF CONTENTS
Safety Information 3
Parts Covered by this Installation Guide 4
Installing IntelliFlow 3 6
Flow Meter and Valve Installation 8
Technical Support 9
Coypright Notice
Satloc, a company of Texas Transland, LLC
Copyright Satloc © (2021). All rights reserved.
No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system or translated into any language or computer language, in any form
or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of Satloc.
Latest Version of the IntelliFlow 3 Liquid Installation Guide
Satloc is dedicated to providing updated versions of installation guidebooks for its customers. Scan
the QR code to verify you have the latest version of the IntelliFlow 3 Liquid Installation Guide or
click this link to make sure this is the latest version _____________.

IntelliFlow 3 Liquid Installation Guide 4875-3000-100 Rev A1
PARTS COVERED BY THIS INSTALLATION GUIDE
is guide is applicable to all IntelliFlow 3 liquid installations for both G4 and Bantam and covers all IntelliFlow 3 kits.
Each table describes the parts that may be included in your installation.
750-0046-000
0.5”x1”x1”, NPTM
750-0122-000
1”x1”x1”, NPTM
750-0091-222
1.5”x2”x 2”, Barbed
752-0010-01
1.5”x1.5”x1.5”, NPTM
752-0015-01
1.5”x2”x2”, NPTM
752-0011-01
2”x2”x2”, NPTM
752-0012-01
3”x3”x3”, Flange
806-1050-000
1”x1”x1”, NPTF
806-1025-000
1.5”x2”x2”, Barbed
806-1033-000
1.5”x1.5”x1.5”, Barbed
806-1049-000
2”x2”x2”, NPTF
806-1022-000
2”x3”x 3”, Barbed
806-1090-000
3”x3”x 3”, Flange
Table 1: Flow Meters (Reference letter is for all ow meters)
Table 2: Valve/Motor (Reference letter is for all valve/motor assemblies)

IntelliFlow 3 Liquid Installation Guide 5875-3000-100 Rev A1
050-2509-000
G4 IF3 Cable
(1) (red cable)
Connects part I’s CONTROLLER
to G4’s FLOW port
050-2508-000
Bantam IF3 Cable
(1) (red cable)
Connects part I’S CONTROLLER to
Bantam’s FLOW port
054-0101-000
Power Cable
(1) (black and white cable)
Connects part I’s POWER cable to
aircra power source, see item K
050-2503-000
IF3 Motor Cable
(1) (red cable)
Connects part I VALVE MOTOR to
valve/motor part B
050-2500-000
IF 3 Pre-amp Sensor Extension
Cable (1) (red cable)
Connects part I FLOW METER to part N
050-2502-000
IF 3 Trim Pressure Switch Cable
(1) (red cable)
Connects part I’s TRIM/PRESSURE
cable to pressure switch part J and
optional pressure transducer part R
806-5002-000
IF3 Controller
(1) (blue box with 6 ports)
Liquid and Dry Controller
075-0035-222
Boom Pressure Switch
(1)
Detects Boom Pressure
424-0004-222
Power Switch/Circuit Breaker
(1, 10A)
Use with cable E, wire in with aircra power
750-0110-03 (1”)
or
750-0109-03 (2”)
or
750-0107-03 (3”)
Aviation Hose
( 1x19.75 of 1”, 2” or 3”)
Use between spray valve and meter; meter
and valve; valve and boom. Attach with
part M.
682-1053-222 (2.25”)
or
682-1054-222 (2.75”)
or
682-1056-222 (3.75”)
Hose Clamp
(4 of 2.25”, 2.75”, or 3.75”)
Attach to Hose L
121-0004-000
3-Pin Flowmeter Sensor
(1)
Magnetic pick-up sensor to use with
ow meter part A
Kit #710-2001-000
Horizontal Mounting Bracket
(2)
Kit #710-2001-000
M4 Screw (4) - part Pa Bolt, 6-32 x 3/8” (8) - part Pd
Washer, split-lock (4) - part Pb Washer, (8) Pe
Vibration Isolator (4) - part Pc Nut, locking 6-32 (8) - part Pf
Use items as required for your specic installation
Kit #711-1001-01
IF System Control Label
(2)
Use with switch on part F
Kit #711-1001-01
Terminal Ring
(2)
121-0033-01
Pressure Transducer
(Optional, not included in kits)
If used, connect to cable H. Can set data
panel or lightbar to display the pressure
reading (option is ‘Primary Boom PSI’).
601-1313-000
(Optional, not included in kits)
Mounting Layout Template for
Falcon/IF3 Rack Mount
601-1317-000
(Optional, not included in kits)
Mounting Layout Template for
Falcon/IF3 Horizontal Mount
Table 3: IntelliFlow 3 Liquid Installation Parts

IntelliFlow 3 Liquid Installation Guide 6875-3000-100 Rev A1
INSTALLING INTELLIFLOW 3
Controller Installation
Mount the controller in an available space on the aircra, for example, in or around the baggage compartment. Ensure
there is enough space for making connections and cable bend radius. Access is needed behind the mounting surface to
attach the nuts to the bolts (part P). When you have selected the mounting location, use one of the plate stencils (part S or
part T) as a template to mark fastener positions. Use drill bit sizes 16 or 28 to drill holes for the fasteners and secure the IF3
Controller (part I) to the aircra using hardware (part P).
Rack Mounting: It is recommended to use the
Mounting Layout Template (PN 601-1313-000) to
assure accuracy for locating the correct position of
the vibration isolators. Thistemplateisavailablefor
purchase.
Horizontal Mounting: It is recommended to use the Mounting
Layout Template (PN 601-1317-000, Part T) to assure accuracy
for locating the correct position of the vibration isolators. This
templateisavailableforpurchase.
1. CPU Rack Mounted Upright (PN 601-1313-000, Part S)
a) Vibration Isolators (Part Pc) With Template (Part S)
i) Place the template (Part S) in the desired location while heeding the above recommendations.
ii) Use the template to mark the fastener hole locations of the four vibration isolator feet (Part Pc). ere
are eight holes at #28 drill bit (0.140”).
iii) Drill holes being careful not to cause damage.
iv) Use parts Pd, Pe, and Pf to attach Pc to the airframe.
v) Use parts Pa and Pb to attach the CPU rack system to vibration isolators (Part Pc).
b) Vibration Isolators Without Template
i) Using parts Pa and Pb attach vibration isolators (Part Pc) to the CPU rack system.
ii) Place CPU in the desired location while heeding the above recommendations.
iii) Mark airframe fastener locations using the open holes in the vibration isolator feet.
iv) Drill holes being careful not to cause damage.ere are eight holes at #28 drill bit (0.140”).
v) Use parts Pd, Pe, and Pf to attach vibration isolators (Part Pc) to approved structure.
2. CPU Horizontally Mounted With Vibration Isolators
a) Horizontal Mounts With Template (PN 601-1317-000, Part T)
i) Place the template (Part T) in the desired location while heeding the above recommendations.
ii) Use the template to mark the fastener hole locations of the four vibration isolator feet (Part Pc). ere
are eight holes at #28 drill bit (0.140”).
iii) Drill holes being careful not to cause damage.
iv) Use hardware from the pre-assembled rack mount system to attach horizontal mounting brackets
(Part O) to the CPU.
v) Use parts Pd, Pe, and Pf to attach vibration isolators (Part Pc) to approved structure.
vi) Use parts Pa and Pb to attach vibration mounts to horizontal mounting brackets (Part O).

IntelliFlow 3 Liquid Installation Guide 7875-3000-100 Rev A1
• Store excess cable lengths with a minimum six-inch bend radius.
• Do not coil cables (introduces noise).
• Avoid high-temperature exposure (for example - the exhaust, exhaust manifold) when routing.
• Hand tighten connections only; do not use tools (overtighten).
Cable Connection Steps to IF3 Controller
1. Connect part C or part D (depending upon the use of a G4 or Bantam GPS) to
the CONTROLLER port of part I.
2. Connect part C or D to the respective G4’s or Bantam’s FLOW port.
3. Connect part E to part I’s POWER port.
4. With part E and part K, ensure part K is a) wired into the aircra’s power
supply and b) cockpit-mounted within easy reach of the pilot. (Install per pilot’s
preference.)
5. Connect part F’s MOTOR cable to Part I’s VALVE MOTOR port.
6. Ensure the bypass switch on part F is cockpit-mounted within easy reach of the
pilot. (Install per pilot’s preference.)
7. Connect part F to part B.
8. Connect part G to part I’s FLOW METER port.
9. Securely connect part N to part A.
10. Connect part G to part N.
11. Connect part H to part I’s TRIM/PRESSURE port.
12. Ensure the trim bump switch on part H is cockpit-mounted within easy reach
of the pilot. (Install per pilot’s preference.)
13. Connect part H’s BOOM SENSOR wires to part J. (Note: Part H’s PRESSURE
TRANSDUCER cable is optional. Use with optional part R.)
b) Horizontal Mounts Without Template
i) Use hardware from the pre-assembled rack mount system to attach horizontal mounting brackets
(Part O) to the CPU.
ii) Use parts Pa and Pb to attach vibration isolators (Part Pc) to horizontal mounting brackets.
iii) Place CPU in the desired location while heeding the above recommendations.
iv) Mark the fastener hole locations of the four vibration isolator feet. ere are eight holes at #28 drill bit
(0.140”).
v) Drill holes being careful not to cause damage.
vi) Use parts Pd, Pe, and Pf to attach vibration isolators (Part Pc) to approved structure.
3) CPU Horizontally Mounted Without Vibration Isolators
a) Horizontal Mounts With Template (PN 601-1317-000, Part T)
i) Place the template (Part T) in the desired location while heeding the above recommendations.
ii) Use the template to mark the fastener hole locations of the 4 fastener locations. ere are four holes at
#16 drill bit (0.177”).
iii) Drill holes being careful not to cause damage.
iv) Use hardware from the pre-assembled rack mount system to attach horizontal mounting brackets
(Part O) to the CPU.
v) Use locally sourced hardware to attach the CPU to approved structure.
b) Horizontal Mounts Without Template
i) Use hardware from the pre-assembled rack mount system to attach horizontal mounting brackets
(Part O) to the CPU.
ii) Place CPU in the desired location while heeding the above recommendations.
iii) Mark the fastener hole locations of the four fastener locations. ere are four holes at #16 drill bit
(0.177”).
iv) Drill holes being careful not to cause damage.
v) Use locally sourced hardware to attach the CPU to approved structure.
Part I: IF3 Controller

IntelliFlow 3 Liquid Installation Guide 8875-3000-100 Rev A1
FLOW METER AND VALVE INSTALLATION
Install the ow meter and valve/motor assembly in the aircra’s existing boom supply tube. Figure 2 shows the
recommended conguration of IntelliFlow 3’s ow meter and valve/motor assembly. If you cannot install the ow meter
and valve/motor vertically (as shown) because of the physical limitations of the aircra, you may vary the rotational
position of either as required.
Figure 2: Recommended Conguration of Flow Meter and Valve/Motor Assembly
e ow meter must be installed before the valve/motor assembly to avoid excessive turbulence. To minimize the
turbulence around the ow meter, cut the hoses (at step 1 below) to maintain the following minimum hose-length to
diameter ratios (i.e., 10:1 or 6:1).
The length between the bypass valve and the owmeter is the most critical; this section should be as long and straight as
possible, exceeding the minimums below when possible. However, it is acknowledged that the recommended minimum
distances are very oen not possible. In such cases, install the meter and valve as far apart as possible.

IntelliFlow 3 Liquid Installation Guide 9875-3000-100 Rev A1
To install the ow meter and valve/motor:
1. Measure and cut hoses to connect (see warning above):
• Spray valve to the ow meter
• Flow meter to the valve/motor assembly
• Valve/motor assembly to the boom
2. Secure the hoses using two clamps at each connection. is now constitutes the ‘IntelliFlow 3 assembly’.
3. Attach the IntelliFlow 3 assembly to the boom supply plumbing.
4. Install one or two support ttings from supporting structures of the belly skin of the aircra close to the valve and ow
meter.
Do not connect support ttings directly to the owmeter or valve/motor. Use stainless wrap-around straps and supports.
Table 4: Minimum Hose Length Between Components
Flow Meter Size Distance Between Spray Valve
and Flow Meter
Distance Between Flow Meter
and Flow Control Motor
3” 10:1 Recommended Min – ≥ 30”
Due to aircra limitations 18” is acceptable
absolute minimum
6:1 Recommended Min – ≥ 18”
2” 10:1 Recommended Min – ≥ 20”
Due to aircra limitations 18” is acceptable
absolute minimum
6:1 Recommended Min – ≥ 12”
1.5” 10:1 Recommended Min – ≥ 15” 6:1 Recommended Min – ≥ 9”
1” 10:1 Recommended Min – ≥ 10” 6:1 Recommended Min – ≥ 6”
.5” 10: 1 Recommended Min – ≥ 5” 6:1 Recommended Min – ≥ 3”
Table of contents
Other Satloc Avionic Display manuals
Popular Avionic Display manuals by other brands

Garmin
Garmin GIA 6300 Installation information

Garmin
Garmin G500 manual

L3 Aviation Products
L3 Aviation Products Lynx NGT-9000 Flight Manual Supplement

Garmin
Garmin GNC 420 installation manual

NAV SD
NAV SD Flymaster NAV SD user manual

Trio Avionics
Trio Avionics EZ Series Operation and installation manual