Savant AMP-1640-01 User manual

AMP-1640-01/1640I-01 Quick Reference Guide 009-0339-03
Copyright 2011 Savant Systems LLC. SAVANTand RacePoint Blueprintare trademarks of Savant Systems LLC.
Savant LLC reserves the right to change product specifications without notice.
770 Main Street, Osterville, MA 02655, Phone 508.683.2500, Fax 508.683.2600, http://www.savantav.com
The AMP-1640-01/1640I-01 Quick Reference Guide provides all the steps necessary to get
the Savant AMP-1640 Multi-channel amplifier up and running. The AMP-1640 is an ultra-
efficient Class D power amplifier delivering 16 channels (8 zones) of reliable, affordable,
feature-rich amplification rated at 40 watts per channel (WPC) at 8 ohms and 50 WPC at 4
ohms. The AMP-1640 is housed in a 3U rack-space metal enclosure.
The AMP-1640 is an ideal eight-zone multi-room music system, as shown below, when paired
with a Savant multi-room audio solution. A multi-room distributed audio solution is defined by
how many listening zones it has. Within a listening zone you can only listen to one audio
source (Internet Radio, CD, Music Server, etc.) at a time.
An audio zone can consist of a single room or a group of rooms. When designing your
distributed audio system, take into account who will use the system and when they will use it.
For instance, you may wire your den for background music and your living room for surround
sound.
A multi-zone system allows different sources to be heard in each of the zones, simultaneously.
The diagram below shows four audio sources connected to the Savant SmartAudio platform
with 4 stereo preamps and 8 stereo outputs connected to the AMP-1640 for a 4 x 8 audio
distribution solution.
Specifications
Environmental
Temperature 32°to 95°F (0°to 35°C)
Humidity 10% to 80% RH (non-condensing)
BTUs 3900 BTUs per hour at maximum load
Physical
Height 5.2 in/13.2 cm
Width 17.3 in/44 cm
Depth 15 in/38.2 cm
Weight 35 lbs/16 kg
Power
Input Power
120 VAC, 60 Hz, 10A (N. America)
230 VAC, 50 Hz, 5A (Europe)
Rated Current Draw 10A (1150 max. wattageconsumption)
Fuse Rating T15AH/250V (120V AREA) / T8AL/250V (230V AREA)
Power Connection IEC 320 power connector with 3-pole detachable power cord
Operating Parameters
Rated Power 40 WPC at 8 ohms, 50 WPC at 4 ohms; (0.1% THD+N, 1kHz)
Input Impedance 33k ohms
Input Sensitivity 750mV for 40W at 8 ohms
Overall Voltage Gain 27.5 dB
Frequency Response Bandwidth limited from 20Hz to 20kHz+0.8 dB
Distortion, THD+N < 0.07% THD+N from 20Hz to 20kHz, All channels driven at 8
ohms
Signal-to-Noise Ratio > 90 dB
Input Triggers 3 – 24V AC/DC
Output Triggers 12V DC (100mA)
Regulatory
Safety and Emissions
CSA NRTL/C
FCC Part 15 Class B
CE
C-Tick
RoHS
Compliant
Installation
The AMP-1640 should be placed on a solid flat surface like a table or shelf or in an audio/video
equipment rack. It should be placed upright so that its weight rests on the unit’s four feet
(removable).
Ventilation
The AMP-1640 must be provided with adequate ventilation for proper cooling. When installing
the AMP-1640 in a cabinet, be sure that the rear of the cabinet is open to adequate air to
provide proper cooling. Be sure to leave a minimum of 3 inches clearance above and behind
the amplifier and at least 2 inches on each side. If installed in a rack, active thermal
management (such as rack fans) is recommended.
Caution: Do not block the ventilation holes on the sides and bottom of the AMP-1640.
Speaker Connectivity
When designing your system specify four to eight ohm speakers.
Cable and Wire
The AMP-1640 has multiple connections on the back panel. Savant recommends that you
clearly label all the input cables and speaker wires. Label the cables and wires with their
destination or source, rather than which terminal of the AMP-1640 they are connected to; it will
be easier to reconfigure your system in the future.
The AMP-1640 connects to your Savant multi-room audio solution via shielded line level audio
cables with RCA phono plugs. Use high quality RCA cables to connect the multi-room audio to
the amplifier inputs.
The AMP-1640 connects to your speakers using 2-conductor speaker wire. For most
applications, Savant recommends using 16 or 18 gauge wire. For wiring runs longer than 80
feet Savant recommends using 14-gauge wire. Each channel features a removable screw
terminal speaker connection for easy installation in tight spaces. The terminal connector can
accommodate up to 14-gauge stranded speaker wire.
Speaker Wire Connections
Caution: All speaker wire connections must be made with the amplifier off.
Bare Speaker Wire – Split the speaker wire insulation so that at least two inches of each
conductor are separated. Strip 1/4 inch of insulation from the end of each conductor of the
speaker wire. Twist the strands of speaker wire together and insert them into the appropriate
screw terminal speaker connection.
Caution: Do not allow a single strand of wire to touch the amplifier chassis or another
connector.
Line Level Source Inputs
Caution: The amplifier must be off whenever you make changes to the input
connections.
Savant recommends labeling all of the interconnecting cables to the sources they connect to
(for example, CD players). Use quality audio patch cables with RCA phono plugs attached to
the ends. Connect the sources by inserting the RCA plug into the amplifier’s RCA jacks.
Connect the outputs from your sources to the inputs on the amplifier.
Caution: Remember never connect a source or preamplifier’s input to the inputs of the
AMP-1640 directly.
AC Power Plug Connection
The last connection made should be the AC power using a standard IEC 3-pole detachable
power cord. Plug the attached power plug into a correctly grounded 120V 60 Hz or 230V 50
Hz wall outlet.
Front Panel
Power LED
The Power LED indicates that the AC power cord is plugged into a working AC power surge
protected receptacle. When the Power LED is Red,the amplifier is in Standby mode, and
when the Power LED is Green the amplifier is On.
Power Button (Master)
The Power button is the master power switch. No matter which turn-on modeyou have
selected, the Power button will turn off all circuitry—including the sensing circuitry. If you will
be away and/or would like to reduce powerconsumption while you are away, set the Power
button to Off (button is out). When you want to return to normal operation, set the Power
button to On (button is in).

AMP-1640-01/1640I-01 Quick Reference Guide 009-0339-03
Copyright 2011 Savant Systems LLC. SAVANTand RacePoint Blueprintare trademarks of Savant Systems LLC.
Savant LLC reserves the right to change product specifications without notice.
770 Main Street, Osterville, MA 02655, Phone 508.683.2500, Fax 508.683.2600, http://www.savantav.com
Protection Modes
The AMP-1640 provides three protection modes. Note that the AMP-1640 does not shut down
in a protection mode; only the faulty zone/channel is disabled.
•Central potential protection mode (LED indication)
The central potential protection mode is the only mode, which activates the Protection
LEDs on the front panel. This mode is more commonly known as the DC potential
protection mode and is designed to protect the connected speakers from any DC voltage
that is output from the AMP-1640. When the central potential protection mode is activated,
the LED for that respective channel will be turned on (Red). When a channel is in the
central potential protection mode other active channels will remain operational unless they
are in a protection mode. After the fault is fixed, the AMP-1640 will automatically restart the
disabled zone/channel.
•Speaker short protection mode (no LED indication)
This mode will disable a zone/channel until the fault is fixed. After the fault is fixed, the
AMP-1640 will automatically restart the disabled zone/channel.
•Overload protection mode (no LED indication)
This mode will disable a zone/channel until the fault is fixed. After the fault is fixed, the
AMP-1640 will automatically restart the disabled zone/channel.
Protection LEDs
The eight zone LEDS indicate the status of each zone, or pair ofchannels when in the central
potential protection mode. A Red LED indicates that thecentral potential protection mode has
been enabled to protect a zone/channel (see above for description).
Rear Panel
Turn-on Mode Switch
The rear panel turn-on mode switch determines when and how the amplifier will turn on.
This switch provides two options for turning the AMP-1640 on and off.
•Constant (manual turn-on via the front panel master Power button)
•3-24 AC/DC Voltage Trigger (External)
Constant – In this mode the front panel master Power button is in the On position. The
amplifier is always on. The front panel master Power button operates the amplifier.
3 – 24V AC/DC Voltage Trigger – This mode provides for the following:
•The master Power button on the front panel must be in the On position.
•The amplifier is off when there is not a 3 - 24V AC or DC voltage applied to the voltage
trigger input.
•Once the sensing circuitry detects a voltage, all adjacent pairs of amplifier channels that
are receiving an audio signal turn on.
•Once the voltage stops, the sensing circuit instantly turns the amplifier off.
•Voltage triggers can be supplied by Savant control platforms, some video projectors, or
some surround sound processors.
External Trigger Connection Diagram
External Trigger Connection Diagram - Daisy Chained
Caution: Do not use a DC wall adapter. The long discharge time of the DC adapter’s
filter capacitor will delay the turn-off of the amplifier.
Note: The 3-24 AC/DC Voltage Trigger mode allows you to configure the amplifier to
turn on automatically.
12V Trigger Control Output
This terminal provides a 12V DC signal suitable for triggering an additional Savant AMP-1640
amplifier. This voltage is present only when the amplifier is active or on. When the amplifier
turns off, the 12V signal is off.
Gain
The output level of each channel can be fined tuned using the gain control for each channel on
the rear panel.
120/230 VAC Voltage Selector
The 120/230 VAC Voltage Selector consists of two switches to power the AMP-1640.
Depending on the voltage required, both switches must be set to either 120 VAC or 230VAC.
Important: The voltage selector is factory set to either 120 VAC or 230 VAC and
secured in position with both locking plates.
DC Voltage Signal Protection
In the event a damaging DC signal becomes present on any of the speaker terminals, the DC
protection circuit shuts down the entire amplifier and the associated red LED under Protection
illuminates. To reset the amplifier you must set the front panel master Power switch to Off and
then On.
Cleaning and Maintenance
The internal parts of the AMP-1640 are electronic and require no maintenance. Once a year it
is appropriate to twist the RCA connectors on each input to remove any oxidation and improve
conductivity. You can clean only with dry cloth. Do not use any spray-type, abrasive cleaners
on the amplifier.
Additional Documentation
Additional documentation for the AMP-1640-01/1640I-01 is available at:
http://www.savantav.com/ >Dealer Login > Knowledge Base > Products.
•Refer to the GPIO Hardware Setup Guide for information on input and output triggers and
GPIO input and outputs to Savant Controllers.
•Refer to the RacePoint Blueprint
Programming Guide on how to configure the AMP-
1640 into a Savant System.
This manual suits for next models
1
Other Savant Amplifier manuals

Savant
Savant Pro Audio 4 Quick reference guide

Savant
Savant IP Audio 1 User manual

Savant
Savant AMP-8040 Series User manual

Savant
Savant AMP-2000-00 User manual

Savant
Savant AMP-8125 User manual

Savant
Savant AMP-1640-20 User manual

Savant
Savant AMP-2000 Series User manual

Savant
Savant AMP-2000-00 User manual