Safety Guidelines
SAFETY AND OPERATION INSTRUCTIONS
Read Instructions thoroughly before assemblage. Metal Conducts Electricity
Avoid use of unit near or in contact of power lines or live
electrical sources.
Do Not Over Encumber
This Unit was designed for a maximum capacity load of 1,111 LBS
(504 kg). Weight Capacity DECREASES with stacking. Only use
Scaffoldmart outriggers and stacking units.
Non-compliance with guidelines may result in serious injury or death.
Refrain from using scaffolding if you are unwell, taking medication, consuming alcohol, mind-altering drugs or
experiencing any other condition that may impair your ability to work
Only use scaffold unit as intended and complying with local, state and national guidelines and legislation.
A competent person should inspect outriggers before every use.
46” outriggers should be installed such that they extend out the side of the multifunction unit. They should be
oriented parallel to the rungs of the frames.
Do not turn the outriggers inward such that they point towards one another, this causes an unstable condition.
Outriggers must be installed in parallel with the end frames (ladders) for stability. Do not use outriggers installed
Outriggers must be installed in parallel with the end frames (ladders) for stability. Do not use outriggers installed
perpendicular to the end frames.
Only use ScaffoldMart outriggers and safety rail system when stacking units.
A competent person should inspect scaffolding unit and accessories in their entirety before using this product.
Never use any component if any part is damaged missing.
Before stacking scaffold units, a set of (4) outriggers with casters must be installed on the base section of
scaffolding and guardrails must be in use.
Outrigger must be tight against end frames and casters must be in contact with a solid, level surface.
Outrigger must be tight against end frames and casters must be in contact with a solid, level surface.
Safety guardrail system must be installed on all sides of scaffold platform where a fall from a height of 6 ft (1.8 m)
or greater may occur.
Always secure guardrail system to the structure using span pins before use.
Manually inspect scaffolding prior to use, ensuring that casters, siderails, and platform properly locked as well as
that any additional components are secured with proper fasteners.
Two side rails must be installed on each level defined by one 6’ multifunction unit, and spaced evenly throughout
Two side rails must be installed on each level defined by one 6’ multifunction unit, and spaced evenly throughout
the scaffold. Scaffold collapse is possible with uneven placement.
Secure casters in frames with span pins before use.
Never climb until all casters are locked. This includes locking the caster on outriggers as well as those in the
scaffold frames.
Only use on level, even surfaces. Avoid using scaffold on surfaces that are soft, muddy, debris filled, holey or
otherwise obstructed.
Only use ScaffoldMart caster jacks to adjust height of casters. Never attach any other material to extend leg of
Only use ScaffoldMart caster jacks to adjust height of casters. Never attach any other material to extend leg of
unit. Do not increase height of scaffold units by any means other than utilizing manufacturer parts designated for
that purpose.
Acids are corrosive and exposure diminishes the integrity of scaffold unit. Do not expose to corrosive materials.
Keep scaffold free of clutter and unnecessary equipment to avoid tripping while in use.
Keep body centered inside structure of scaffold to avoid tipping.
Remove or fasten all tools, material or equipment before moving scaffolding. Never move scaffold while a person
Remove or fasten all tools, material or equipment before moving scaffolding. Never move scaffold while a person
is on unit. Be careful when moving unit to avoid tipping.
Never move scaffold with living things on or under unit.
Never use powered devices to propel this scaffold unit. Be mindful using scaffold near machinery.
Never use scaffold on uneven surfaces.
Never use scaffold during high winds or inclement weather.
Maintain a constant firm grip while climbing scaffold.
Never modify scaffolding parts. They are designed by the
manufacturer to perform in a certain way, modifications
compromise their integrity and safety.
Never use scaffold to bridge between objects.
AVAILABLE UPGRADES
3 - 4 Guard
Rail System
MFGRSET3/4
Set of 18”
Outriggers
MFOUTR18A
Stability Kit
MFSTABKIT
Never modify scaolding parts. They are designed by the
manufacturer to perform in a certain way, modications
compromise their integrity and safety.
Never use scaold to bridge between objects.
Metal Conducts Electricity
Avoid use in proximity to power
lines or other live electrical circuits
Read instructions throroughly before assembling unit.
Failure to read and follow instructions may result in serious injury or death.
Do Not Over Encumber
6’ Multifunction unit was
designed for a max capacity of
1,000 lb.
Weight capacity decreases
with stacking.