Schaudt Electrobloc EBL 269 User manual

© 2010 Schaudt GmbH, Elektrotechnik & Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Phone +49 7544 9577-0, Telefax +49 7544 9577-29, www.schaudt-gmbh.de
811.598 BA / EN Situation: 25.06.2010
0 Instruction Manual Electrobloc EBL 269
Instruction manual
Electrobloc EBL 269
Table of contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2 Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3 Description and appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . .4
4 Suitable accessories (not supplied) . . . . . . . . . . . . . . . . . . . . . . . .5
5 Electrical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
8 Shutting down the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
9 Changing the battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
10 Technical faults, possible causes and remedies . . . . . . . . . . . . . .8
11 Customer service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
12 Block diagram - for specialist workshop only. . . . . . . . . . . . . . . .10
13 Fault report. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

2Situation: 25.06.2010 811.598 BA / EN
Instruction Manual Electrobloc EBL 269
1 Introduction
This instruction manual contains important information for safe operation of
the Electrobloc. It is essential to read and to follow the given safety informa-
tion.
The instruction manual should always be kept in the motorhome/caravan. All
safety information must be passed on to other users.
The reproduction, translation and duplication of this manual, even in parts, is
not allowed without written authorization.
2 Safety information
The design of the Electrobloc is state-of-the-art and according to approved
safety technology. Nevertheless, if the safety information in this instruction
manual is not closely followed, persons might get injured or the Electrobloc
might be damaged.
Do not use the Electrobloc if it is not in technically good order and condition.
The instruction manual must be followed.
Any technical faults affecting the safety of persons or of the Electrobloc must
be dealt with immediately by qualified personnel.
▲Failure to comply with this sign may lead to the endangerment of per-
sons.
▲Failure to comply with this sign may damage the device or the connected
consumers.
▲This sign indicates recommendations or special features.
▲The electrical system of the motorhome or the caravan must meet cur-
rent DIN, VDE and ISO regulations. Manipulations of the electrical
system will endanger the safety of persons and the vehicle, and are
therefore prohibited.
▲Never make any modifications to the Electrobloc.
▲The electrical connection may only be established by qualified person-
nel and must be carried out according to the Schaudt installation
instructions.
▲Connection work is to be carried out in tensionless condition only.
▲Riskof fatalinjury dueto electric shockor fireinthe caseof a defective
mains cable or incorrect connection!
▲Risk of fatal injury!
Never perform maintenance on the Electrobloc when it is live.

811.598 BA / EN Situation: 25.06.2010 3
Instruction Manual Electrobloc EBL 269
▲Blown fuses must only be replaced when the cause of the fault is
known and eliminated.
▲Never bridge or repair fuses.
▲Danger of burning! Blown fuses must only be changed on a zero-cur-
rent Electrobloc.
▲Only use original fuses rated as specified in the instruction manual.
▲Danger of burning! During operation the back of the Electrobloc gets
hot. Do not touch.
▲Danger of explosion from formation of detonating gas due to an incor-
rectly set battery selector switch, defective batteries, defective Elec-
trobloc or an excessively high battery working temperature (more than
30 °C).
▲The mains connection linemay only be replaced by an authorised cus-
tomer service department or by qualified persons.
▲The AES refrigerator fuse may only be used if a AES refrigerator is con-
nected. Otherwise, the living area battery may get totally discharged. Bat-
tery damage is possible.
▲An incorrectly set battery selector switch damages the living area battery.
▲Disconnect the Electrobloc from the mains before adjusting the battery
selector switch.
▲If the living area battery is changed or removed, the frost protection valve
on the heater system opens automatically. Water may be lost. For more
information, see the instruction manual of the heater system.
▲Before and after shutdown, the living area battery must be fully recharged
to avoid battery damage. For this purpose the vehicle must be connected
to mains supply for a minimum of 12 hours with an 80 Ah battery and
24 hours with a 160 Ah battery.
▲Do not operate the Schaudt solar charge regulator without a battery. This
might damage the solar charge regulator or any connected consumers. If
the battery is going to be changed or removed, take off the positive lead
"+ Solarzelle" (+ Solar Module) on the solar charge regulator.
▲Toavoidvoltage peaksduringwarm-up,do not connectthegeneratoruntil
it is running in a stable manner. Otherwise, the Electrobloc, the 12 V con-
sumers or other connected equipment might get damaged. It is essential
that the generator complies with the mains supply specifications.
▲The mains supply on board car ferries might not always be perfect. There-
fore, never connect the Electrobloc to the mains on car ferries. Otherwise,
the Electrobloc, the 12 V consumers or other connected equipment might
get damaged.

4Situation: 25.06.2010 811.598 BA / EN
Instruction Manual Electrobloc EBL 269
3 Description and appropriate use
The Electrobloc EBL 269 is designed as a main power distibutor for
motorhomes. The Electrobloc is a permanent installation. The Electrobloc is
for charging batteries and supplying 12 V appliances with power.
The electrical management system "Electrobloc" consists of:
●The LAS 1218 charger module
●The 12 V distribution
●Fuses for the 12 V circuits
●Other control and monitoring functions
The charger module is a primary controlled switch-mode power supply. This
modern switching technology achieves high charging performance at a com-
pact size and low weight.
Acontroland switchpanelhas to beconnected for operation.Thiscontrol and
switch panel controls the electrical functions in the living area of the
motorhome, including accessories.
There are connections for an auxiliary charging unit and a solar charge regu-
lator.
Fig. 1 Electrobloc EBL 269 front view
1 Mains connection
2 Flat vehicle fuses
3 Battery selector switch
4 Connections block 8
5 Connections block 7
6 Connections block 6
7 Connections block 4: Solar charge regulator
8 Connections block 5: Control and switch panel
9 Connections block 3: Auxiliary charging unit
10 Connections block 2
11 Connections block 1
12 Fuse value 1)
1) The various types have differing fuse values.
▲This device is not intended to be used by persons (including children) with
limited physical, sensory or mental aptitude or lack of experience and/or
knowledge unless they are supervised by a person responsible for their
safety or have received instruction from this person as to how the device
is used.
▲Children are to be supervised so as to ensure they do not play with the
device.
▲This device is exclusively designed for installation into a vehicle.
SDT00294
1 2 34
58912 671011

811.598 BA / EN Situation: 25.06.2010 5
Instruction Manual Electrobloc EBL 269
4 Suitable accessories (not supplied)
Control and switch panel IT 269-3, LT 300
Auxiliary charging unit Schaudt battery charging unit type LAS... with up to 18 A charge current
Additional 2-pin charging cable, lengths supplied on request
Solar charge regulator Schaudt solar charge regulator type LR... for solar modules with a total cur-
rent of 14 A incl. 0.5 m connection cable and connector plug
5 Electrical data
6 Operation
6.1 Operating controls
Flat vehicle fuses
The flat vehicle fuses protect the various circuits.
Start up the system Switch on the system using the 12 V main switch at the control and switch
panel. Follow the instruction manual of the control and switch panel.
Shutting down the system
Switch off the system using the 12 V main switch at the control and switch panel.
Type no. Fuse value
911.520 2.5 A slow blow
911.525 2.5 A slow blow
911.521 3.15 A slow blow
911.526 3.15 A slow blow
Mains connection 230 V AC ± 10 %, 47 to 63 Hz sinusoidal, protection class I
Suitable batteries 6-cell lead acid or lead gel batteries of at least 55 Ah
Current-carrying capacity 12 V outputs No more than 90 % of the rated current
of the appropriate fuse may be drawn,
see the block diagram.
▲Blown fuses must only be replaced when the cause of the fault is
known and eliminated.
▲Never bridge or repair fuses.
▲Danger of burning! Blown fuses must only be changed on a zero-cur-
rent Electrobloc.
▲Only use original fuses rated as specified in the instruction manual.
▲Before starting up:
●Make sure the living area battery is connected.
●Make sure the battery selector switch is set for the correct type of bat-
tery.
●Make sure the AES fuse is only used if the compressor/AES refrigera-
tor is connected. Otherwise, the living area battery may get totally dis-
charged. Battery damage is possible.

6Situation: 25.06.2010 811.598 BA / EN
Instruction Manual Electrobloc EBL 269
Battery selector switch
Theswitchingoptionprovidedbythe batteryselectorswitch ensuresoptimum
charging of the two different types of battery, lead acid and lead gel. The
switch must be set to the correct battery type: lead acid or lead gel.
Use a thin object (e.g. a ballpoint pen cartridge) to move the battery selector
switch.
Set lead gel battery: Set the battery selector switch to "Blei-Gel" (lead gel).
Set lead acid battery: Set the battery selector switch to "Blei-Säure" (lead
acid).
12 V main switch (on the
control and switch panel) The 12 V main switch on the control and switch panel switches all consumers
and the panel on and off.
Exceptions:
●Frost protection valve
●Heater
●Step
●AES/compressor refrigerator
●For EBL 269 and EBL 269 A: Circuit 1, awning light
●For EBL 269-2 and EBL 269-2 A: Circuit 4, circuit 5
For more information, see the instruction manual of the control and switch
panel.
6.2 Additional functions
Automatic switch function
for AES/compressor
refrigerator
This relay supplies the AES/compressor refrigerator with power from the
starter battery when the vehicle engine is running and the D+ connection is
live. An AES/compressor refrigerator is powered by the living area battery
when the vehicle engine is switched off.
Automatic switch function
for absorber refrigerator This relay supplies the absorber refrigerator with power from the starter bat-
tery when the vehicle engine is running and the D+ connection is live.
Mains charging of starter
battery This feature provides an automatic float charge for the starter battery at up to
2 A when the 230 V mains is connected to the Electrobloc.
▲Danger of explosion from formation of detonating gas due to an incor-
rectly set battery selector switch, defective batteries, defective Electrob-
loc or an excessively high battery working temperature (more than
30 °C).
▲An incorrectly set battery selector switch damages the living area battery.
▲Disconnect the Electrobloc from the mains before adjusting the battery
selector switch.

811.598 BA / EN Situation: 25.06.2010 7
Instruction Manual Electrobloc EBL 269
7 Maintenance
The Electrobloc requires no maintenance.
Cleaning Clean the Electrobloc with a soft, slightly damp cloth and mild detergent.
Never use spirit, thinners or similar substances.
Do not allow fluid to penetrate the inside of the Electrobloc.
8 Shutting down the system
Switch off the system if you are not going to use the vehicle for a lengthy peri-
od (for example during the winter).
Disconnecting the living
area battery from the 12 V
power supply
Carry out the following work steps in the correct sequence:
1. Switch off the 12 V main switch on the control and switch panel.
2. Remove the plug "+ Solarzelle" (+ Solar Module) on the solar charge reg-
ulator.
3. Remove the clamps from the battery poles.
9 Changing the battery
Only use batteries of the same type and capacity and those installed by the
manufacturer.
You can change from lead acid to lead gel batteries.
You cannot change from lead gel to lead acid batteries. Ask your dealer for
advice.
▲Before and after shutdown, the living area battery must be fully recharged
to avoid battery damage. For this purpose the vehicle must be connected
to mains supply for a minimum of 12 hours with an 80 Ah battery and
24 hours with a 160 Ah battery.
▲Do not operate the Schaudt solar charge regulator without a battery. This
might damage the solar charge regulator or any connected consumers. If
the battery is going to be changed or removed, take off the positive lead
"+ Solarzelle" (+ Solar Module) on the solar charge regulator.
▲Batteries may only be changed by qualified personnel.
▲Follow the instructions of the battery manufacturer.
▲Charging unsuitable types of battery may irreparably damage them.
▲Only use the Electrobloc for connecting the 12 V power supply to 6-cell
lead gel or lead acid batteries.
▲Danger of explosion from formation of detonating gas due to an incor-
rectly set battery selector switch, defective batteries, defective Electrob-
loc or an excessively high battery working temperature (more than
30 °C).

8Situation: 25.06.2010 811.598 BA / EN
Instruction Manual Electrobloc EBL 269
Theswitchingoptionprovidedbythe batteryselectorswitch ensuresoptimum
charging of the two different types of battery, lead acid and lead gel. The
switch must be set to the correct battery type: lead acid or lead gel.
Use a thin object (e.g. a ballpoint pen cartridge) to move the battery selector
switch.
Set lead gel battery: Set the battery selector switch to "Blei-Gel" (lead gel).
Set lead acid battery: Set the battery selector switch to "Blei-Säure" (lead
acid).
10 Technical faults, possible causes and remedies
If you are unable to solve a fault using the following tables, please contact our
customer service address.
If this is not possible, e.g. if you are abroad, you can have the Electrobloc
repaired at a specialist workshop.
Inexpert repairs invalidate the guarantee for the Electrobloc and Schaudt
GmbH takes no liability for any resulting damage.
▲An incorrectly set battery selector switch damages the living area battery.
▲Disconnect the Electrobloc from the mains before adjusting the battery
selector switch.
Fault Possible cause Remedy
Living area battery is not
charged during 230 V
operation (battery voltage
constantly below 13.3 V)
No mains voltage Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Defective Electrobloc Call customer service
Living area battery is over-
charged during 230 V
operation (battery voltage
constantly above 14.5 V)
Defective Electrobloc Call customer service
Starter battery is not
charged during 230 V
operation (battery voltage
constantly below 13.0 V)
No mains voltage Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Defective Electrobloc Call customer service
Living area battery is not
charged during mobile
operation (battery voltage
below 13.0 V)
Defective alternator Have the alternator
checked
No voltage at D+ input Have the fuse and wiring
checked
Defective Electrobloc Call customer service
The living area battery is
overchargedduringmobile
operation (battery voltage
constantly above 14.3 V)
Defective alternator Have the alternator
checked

811.598 BA / EN Situation: 25.06.2010 9
Instruction Manual Electrobloc EBL 269
11 Customer service
Customer service address Schaudt GmbH, Elektrotechnik & Apparatebau
Planckstraße 8
88677 Markdorf
Germany
Phone: +49 7544 9577-16
Email: kundendienst@schaudt-gmbh.de
Sending in the device Returning a defective device:
Always use well-padded packaging.
Fill in and enclose the fault report, see section 13.
Send it to the addressee delivered free.
Disposal instruction When theproduct servicelife isover,disposeof thedevice inaccordancewith
the applicable regulations.
The refrigerator does not
work during mobile opera-
tion
No power supply to the
refrigerator Have the fuse and wiring
checked
Defective Electrobloc Call customer service
Defective refrigerator Have the refrigerator
checked
Solar charger does not
work (power supply and
engine are off)
Solar charge regulator not
plugged in Plug in the solar charge
regulator
Defective fuse or wiring Have the fuse and wiring
checked
Defective solar charge reg-
ulator Have the solar charge reg-
ulator checked
12 V power supply in the
living area does not work 12 V main switch for the liv-
ing area battery is
switched off
Switch on the 12 V main
switch for the living area
battery
Defective fuse or wiring Have the fuse and wiring
checked
Defective Electrobloc Call customer service
Fault Possible cause Remedy
▲If the device becomes too hot due to excessive ambient temperature or
lackofventilation,thechargingcurrentisautomaticallyreduced. However,
always prevent the device from overheating.
Opening hours Mon to Thu
Fri 8 to 12 a.m., 1 to 4 p.m.
8 to 12 a.m.

10 Situation: 25.06.2010 811.598 BA / EN
Instruction Manual Electrobloc EBL 269
12 Block diagram - for specialist workshop only
Fig. 2 Block diagram of Electrobloc EBL 269
!
!
!
!
!
!
!
3 !
!
%
!
!
!
!
!
!
3(5.4
!
!
!
!
!
!
!
!
!
!
!
!
%&
!
!
!
!
!
!
!
!
!
!
6'7
Charging relay for
starter battery
MNL socket cap 2x - block 3
Negative auxiliary charging unit
LAS...
14.3 V - 18 A + Auxiliary charging unit
70A battery cut-off
relay The negative pole of the living
area battery must be connected
externallytothenegativepoleof
the starter battery.
230 V mains ~ 50Hz
Standard mains socket Switch between
lead gel/
lead acid + Starter battery
+ Living area battery
Negative living area
battery
Plug connector MSFQ/0 12x - block 5
Shunt battery
Shunt consumer
Mains indicator
12 V on
12 V off
12 V indicator
+ Living area battery sensor
60 A main
switch relay Negative living area battery sensor
Pin rail MSFQ/0 4x - block 8 + Starter battery
12 V off Pump switch
Spare
12 V on
12 V indicator Light
Negative living area
battery sensor MNL socket cap 5x - block 2
+ Starter battery for
refrigerator *
Negative living area battery sensor
+ Living area battery sensor
Negative starter batteryfor refrigerator *
Absorber
refrigerator D+ input
MNL socket cap 4x - block 1
D+ base
Negative refrigerator
Compressor
refrigerator + Absorber refrigerator
+ Compressor/AES refrigerator
MNL socket cap 12x - block 7
D+ base
+ Pump
Switching
stage Constant negative to pump
Connected negative pole of pump
TV *Refrigeratorlinesmustbe
lead to the battery poles
withoutbeing connected to
other battery supplies.
** Only applies for
EBL 269-2 and
EBL 269-2 A
Light 1
Light 2
Spare
MNL socket cap 9x - block 6
Frost protection valve
Arenotswitchedoff
via the main 12 V
switch on the
instrument panel.
MNL socket cap 3x - block 4 (15A**) Circuit1(circuit4**)
Solar
charge
regulator
type LR...
Heater
Step
(15A**)
Solar module Awning light
(circuit 5**)
Circuit board KPL EBL 269 type no. 771.498

811.598 BA / EN Situation: 25.06.2010 11
Instruction Manual Electrobloc EBL 269
13 Fault report
In the event of damage, please return the defective device together with the
completed fault report.
There is the following defect:
(please tick)
Other remarks:
Device type:
Type no.:
(please enter)
EBL 269
Battery not
being charged
during power
operation
Battery not
being charged
during mobile
operation
The following
electrical con-
sumers do not
work:
Constant fault
Temporary
fault/loose con-
tact

12 Situation: 25.06.2010 811.598 BA / EN
Instruction Manual Electrobloc EBL 269
Table of contents
Other Schaudt Power Distribution Unit manuals
Popular Power Distribution Unit manuals by other brands

brennenstuhl
brennenstuhl Professional BSV 5 5/4 N5160 AT operating instructions

SMA
SMA MULTICLUSTER-BOX 12 operating manual

LEGRAND
LEGRAND Raritan PX3-4000 Series user guide

Flintec
Flintec KEK-4 Technical manual

Eaton
Eaton Pow-R-Line P2R Series instruction manual

DRIESCHER
DRIESCHER MINEX-E Operation – and Assembly Instruction