*44487049*
44487049
Input 120/240 VAC, 2.4 A, 50/60Hz, High Voltage Class 1 Wiring Required
Output 6 Amp DC @ 12/24 VDC
Enclosure 14” H x 12” W x 4” D (8 knockouts, 1/2” or 3/4” )
Temperature Range 32°-120° F (0°- 49° C)
Fuse F1, T6.3A
250 VAC
Compliance UL 294, ULC-S318, RoHS, & FCC Part 15, Class 1 Output
Compatible Boards
(Optional, 3 boards maximum)
900-2RS
900-4R
900-4RL
900-8F
900-8P
Fire Alarm Input Board (Optional) 900-FA (Requires one option board above)
Battery Backup Board (Optional) 900-BB
AC Monitor Output Form C Contacts, 30 VDC, 1 Amp, Resistive Load
These instructions cover the following parts:
PS906 Power Supply - Pages 1-3
900-KL Keylock (optional) - Page 2
900-BB Battery Backup (optional) - Page 3
F1
DANGER
!
!
DANGER:
!
WARNING:
!
WARNING:
INST. INSTRUCTIONS - 24125007
INST. INSTRUCTIONS - 44487106
INST. INSTRUCTIONS - 44487080
INST. INSTRUCTIONS - 44487106
INST. INSTRUCTIONS - 44487106
INST. INSTRUCTIONS - 44487072
INST. INSTRUCTIONS - 44487064
PS906 Power Supply Specications:
Power Supply
PS906
Installation Instructions
DANGER
To avoid risk of electric shock, turn off AC power before
installing or servicing PS906 power supply
CAUTION
For protection against risk of re, replace fuse with same type and rating