9. TROUBLESHOOTING
In case of emergency, please, use the troubleshooting methods shown in tables. If it is impossible to
solve problems with these methods, apply to the service center.
Table 2
Problem Possible cause Remedy
Poor atomizing (insucient capacity)
The unit is operating in the minimized mode (low
atomizing frequency)
There is no problem. If you need to switch to the intensive
mode of operation, turn the regulator handle all the way
to the right.
The atomizer is clogged Clean the atomizer.
Temperature of water in the tank is too low Set maximum capacity. The humidier’s capacity will go
up after a while.
No atomizing The power cord is poorly connected to the outlet Connect the power cord into the outlet carefully
There is white deposit on objects around the
humidier (salts, separating out from water)
1. Lime deposits have formed on the membrane
2. There is a lot of salts in the water used (calcium
and magnesium)
1. Clean the humidier’s membrane with a special brush
2. Use ltered water
Steam has an unpleasant odor
Stale water is used Clean the unit according to the cleaning and servicing
instructions and ll the tank with fresh water
Remains of stale water or waste have accumulated in
the unit’s case or the atomizer
Condensate is formed on the upper part of the
humidier and on surrounding objects, when
it is operating.
1. High humidication intensity is set.
2. High room humidity and temperature.
Lower the humidication intensity by turning the on/o
and steam outow intensity regulator counterclockwise.
Water appears next to the humidier, when it
is operating.
1. High humidication intensity is set.
2. Lime deposits have formed on the membrane and
in grooves for water (in the unit’s base).
1. Lower the humidication intensity by turning the on/o
and steam outow intensity regulator counterclockwise.
2. Clean the unit according to the cleaning and servicing
instructions.
Water appears next to the humidier, when it is
not operating Water tank is leaking You need to contact an authorized service center