SDI HPDA-100RM-C User manual

SDI
SPECTRADYNAMICS, INC.
HIGH PERFORMANCE DISTRIBUTION AMPLIFIER
HPDA-100RM-C
OPERATING MANUAL
SPECTRADYNAMICS, INC •1849 Cherry St. Unit 2. •Louisville, CO 80027
Phone: (303) 665-1852 •Fax: (303) 604-6088
www.spectradynamics.com


Copyright © SpectraDynamics, Inc. 2010
1
The HPDA-100RM-C is a high performance distribution and isolation amplifier. The
standard unit contains three HPDA-100 modules. Each module provides five unity gain
outputs for every input signal. The HPDA-100RM-C may be modified upon request to
contain only two HPDA-100 modules.
The following specifications are valid for any HPDA-100RM-C that provides five unity
gain outputs for every input signal. Typical cross channel isolation and reverse isolation
is generally greater than 100 dB. The phase noise of the modules is exceptionally low,
typically –145 dBc/Hz @ Fourier frequency of 1 Hz and –174 dBc/Hz @ Fourier
frequency greater than 10 kHz. Both the input and output are matched to 50 ohms to
obtain better than 20 dB return loss.
Description
SDI
SPECTRADYNAMICS,INC • 1848 Cherry St Unit 2. •Louisville, CO 80027 •Phone: (303) 665-1852 •Fax: (303) 604-6088
Se habla español

Copyright © SpectraDynamics, Inc. 2010
2
CAUTION!
Voltages capable of causing injury or death are present in this instrument. Use extreme
caution whenever the instrument cover is removed.
Line Voltage
This instrument may be setup to operate on 100-120 or 220-240 VAC and a line
frequency of 50 to 60 Hz. The setup voltage for this HPDA-100RM-C is specified on
page 4.
Fuse
A 0.50 Ampere 250V slow-blow fuse is used for 100-120 VAC operation.
A 0.25 Ampere 250V slow-blow fuse is used for 220-240 VAC operation.
Only replace fuses with the same type and specifications.
Line Cord
The instrument has a detachable, three wire power cord for connection to a grounded
power source. The enclosure of the unit is directly connected to the outlet ground to
protect against electrical shock. Always use an outlet with a protective ground and do
not disable this safety mechanism.
Service
Do not attempt to service or adjust the instrument unless another person, capable of
providing first aid or resuscitation, is present. Contact SDI for any questions or repairs.
SpectraDynamics, Inc.
1849 Cherry Street Unit 2.
Louisville, CO 80027
USA
Tel: (303) 665-1852
Fax: (303) 604-6088
support@spectradynamics.com
www.spectradynamics.com
Safety and Preparation for Use
SDI

Copyright © SpectraDynamics, Inc. 2010
3
AC Power LED
The AC POWER LED will turn on when AC power is applied to unit and the unit is
operating properly.
DC Power LED
The DC POWER LED is on when DC power is applied to unit and the unit is operating
properly.
Monitor LED
The MONITOR LED of each module will turn on if all the output signals to the
corresponding module are greater than +7 dBm.
The Front Panel
SDI
The Front Panel
SDI

Copyright © SpectraDynamics, Inc. 2010
4
AC POWER ENTRY MODULE
The HPDA-100RM-C is configured to operate on:
100-120 VAC
220-240 VAC
DC POWER ENTRY MODULE
Optional Battery Backup Connector for +24 VDC Backup power source.
SMA INPUTS
The standard HPDA-100RM-C contains three amplifier modules each having one input
SMA connector. If you acquired a modified unit with only two HPDA modules the back
panel will contain only two SMA input connectors. The signal to be distributed should be
connected to the corresponding SMA jack labeled INPUT.
SMA OUTPUTS
There are five SMA OUTPUTS for each SMA INPUT. Any output may be used to drive
the input of another distribution module. The five outputs of each amplifier module are
DC isolated from the chassis ground to prevent ground loops. Make sure that the
amplifier ground does not float to a potential greater than 50 VDC from the chassis
ground. An output ground potential greater than 50 VDC will damage the amplifier and
could cause injury or death to personnel.
The Back Panel
SDI
The Back Panel
SDI

Copyright © SpectraDynamics, Inc. 2010
5
Description
The battery backup module allows the HPDA-100RM-C instrument to be powered by a
+24 VDC power source in case of loss of the main AC power. The switch from AC to
DC supply operation is affected by a Schottky diode network and charge storage
capacitors to ensure glitch free operation. The +24 VDC power source connector is
located on the back panel of the instrument. The +24 VDC ground is not connected to
the instrument case ground internally, however both ground connections are available
at the DC power connector and may be connected together at this point.
DC Voltage
The +24 VDC may be used as backup power to prevent loss of signal during power
outages. The DC power supply should be able to provide +24 VDC at 2A. For
optimum performance the following specifications should be used for the power supply.
DC Supply +24 VDC, 2 A
Line regulation +/- 0.05% for a 10% line change
Load regulation +/- 0.05% for a 50% load change
Output ripple < 5mV peak-to-peak
DC Fuse 2.0 Ampere 250V slow-blow
Fuse
A 2.0 Ampere 250V slow-blow fuse is used for +24 VDC operation.
Replace fuses with the same type and specifications
Service
Do not attempt to service or adjust the instrument unless another person, capable of
providing first aid or resuscitation, is present. Contact SDI for any questions or repairs.
Operation
To operate the unit on DC power, locate the DC power entry connector on the rear
panel and connect the power cable. When DC power is applied to the unit, the LED
located on the front panel labeled DC POWER should light up. Connection of the
+24 VDC supply is optional.
Battery Backup Module
SDI

Copyright © SpectraDynamics, Inc. 2010
6
WARNING!
DO NOT APPLY AC VOLTAGE TO THIS UNIT THROUGH THE 6 PIN CONNECTOR
ON THE REAR OF THE UNIT!
Failure to follow these directions will cause injury or death to personnel, cause
irreparable damage to the instrument and void all warranties.
WARNING!
DO NOT REVERSE THE POLARITY OF THE SUPPLY VOLTAGE!
Reversing the polarity of the power supply will cause damage to the unit and void
all warranties.
WARNING!
The chassis of the instrument is internally connected to DC ground.
The +24 VDC connector is wired as follows:
Pin 1 NC
Pin 2 NC
Pin 3 NC
Pin 4 +24 VDC GND return
Pin 5 +24 VDC power
Pin 6 Chassis GND / Earth GND
DC Connector
SDI
DC Connector
SDI

Copyright © SpectraDynamics, Inc. 2010
7
This unit is designed to operate only with the specified AC voltage on page 4
and +24 VDC. For conversion to a different voltage of operation contact
SpectraDynamics, Inc.
To operate the unit, locate the AC power entry module on the rear of the enclosure
and/or the DC connector and connect the power cord(s). Plug the unit into an
appropriate power outlet. The LED on the front panel labeled AC POWER will turn on
when you apply the AC voltage. If you also apply the DC voltage the LED labeled DC
POWER on the front panel should light up. Attach the signal to be distributed to one of
the SMA input connectors on the back panel. Any HPDA-100RM-C output may be used
to drive the input of another distribution module.
Absolute Maximum Ratings
Input power +20dBm Maximum
Reverse Power +20dBm Maximum
Input DC Voltage 10 VDC Maximum
Output DC Voltage 50 VDC Maximum
Storage Temperature -10 to +75 ºC
Operation Environment 0 to +50 ºC
Rack Mount Chassis 1U H, 19“ W, 14” D
Operation
SDI

Copyright © SpectraDynamics, Inc. 2010
8
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
Max. Input Power
1 dB compression
15
16
-
dBm
Bandwidth
+/- 1 dB
80 - 120
-
-
MHz
Gain
@ 100 MHz
-
-
+/- 0.5
dB
Impedance
input
output
-
-
50
50
-
-
Ohms
Return Loss
input(S11) 5MHz
output(S22) 5MHz
-
-
-22
-30
-20
-25
dB
Distortion
+13 dBm
-
-40
-48
dBc
Isolation
output to output
output to input
95
105
100
110
-
-
dB
Phase Noise
10 Hz
100 Hz
1 kHz
10 kHz
-
-
-
-
-158
-165
-171
-174
-155
-162
-168
-171
dBc/Hz
All tests done at 100 MHz and +13 dBm input unless otherwise specified.
Specifications
SDI

Copyright © SpectraDynamics, Inc. 2010
9
The HPDA-100RM-C is warranted to be free of defects under normal operating
conditions, as specified, for one year from date of original shipment from
SpectraDynamics, Inc (SDI). SDI’s obligation and liability under this warranty is
expressly limited to repairing or replacing, at SDI’s option, any product not meeting the
said specifications. This warranty shall be in effect for one (1) year from the date a
HPDA-100RM-C is sold by SDI. SDI makes no other warranty, express or implied, and
makes no warranty of the fitness for any particular purpose. SDI’s obligation under this
warranty shall not include any transportation charges or costs of installation or any
liability for direct, indirect, or consequential damages or delay. Any improper use,
operation beyond capacity, substitution of parts not approved by SDI, or any alteration or
repair by others in such manner as in SDI’s reasonable judgement affects the product
materially and adversely shall void this warranty. No employee or representative of SDI
is authorized to change this warranty in any way or grant any other warranty.
SDI
Warranty
SDI
SPECTRADYNAMICS,INC •1849 Cherry St. Unit 2. •Louisville, CO 80027 •Phone: (303) 665-1852 •Fax: (303) 604-6088
Se habla español

HPDA-100RM-C:3I-15O/R02
Other manuals for HPDA-100RM-C
1
Table of contents
Other SDI Amplifier manuals