INSTALLATION MANUAL
All specications stated are subject to change without notice.
SEAS 4040
Line amplier for 48 outlets; 36/44 dB
Sea Systems AB - Terminalgatan 19A - SE 235 39 Vellinge - Sweden
Tel.: +46 40420250 - www.seasystems.se
- 3/4 -
INSTALLATION
Never install the line amplier with out looking at the instructions inside! Make
sure to know which connections go where before connecting cables etc.
TECHNICAL SPECIFICATION
Size (H) 265 x (W) 190 x (D) 110 mm
Housing Aluminium Die-casting, Finishing: Black painted
Connectors IN: 5/8”-24 NEF F-Female to 3/8”-32 UNEF F-Female Adaptor
OUT: F-Female Connector (4 pcs)
Weight 3.50 Kg
Electrical Specication
RF Amplication Push-Pull Hybrid Module
Operation Gain (w/ RA-30) 100 KHz 16.5 dB min.
5 MHz 22.0 dB min.
IN-OUT 27 MHz 27.0 dB min.
47~862 MHz 36.0 dB min. w. 4 outputs
47~862 MHz 42.0 dB min. w. 1 output
Operation Gain 44.0 dB min.
Gain Control 0~ -18.0 dB (adj.)
Slope Control (w/ MS-86/ 18) 0~ -18.0 dB (adj.)
Auto Level Control (w/ ALC-12) +/-12.0 dB
Noice Figure 47~862 MHz 8.0 dB typ. 9.0 dB max.
Output Level (Reference) 55/ 550/ 862 MHz 77 NTSC chs. +312 MHz digital*
(97 / 102 / 94 dBu V)
Composite Second Order (CSO) -60 dBc
Composite Triple Beat (CTB) -60 dBc
Cross Modulation (XMOD) -60 dBc
Return Loss 100~300 KHz 6 dB min.
(w/ Jumpers) 300 KHz~27 MHz 14 dB typ. 12 dB min.
47~862 MHz 12 dB typ. 10 dB min.
General Specications
Input Voltage 100-230 VAC +/-5% / 50/60Hz.
Input & Output Test Ports -20 +/- 2 dB, F-Female
Input & Output Impedance 75 Ohm
Surge Protection 7000 V for 1.2 x 50 µs
Fuse (For Power Supply) 0.2 A / 250 V (230 Vac)
Power Consumption (Including Powering output to Antenna) 35 W
AC Cord AC Inlet Module; 1,5m cord w. Schuko
Operating Temperature -40 to +60°C
Muting Build-in relay activated by singel pole switch.
EMC & Safety
EMC EN55027-2, EN61000-3-2/3-3/4-2-4-6
Safety EN60945, EN60950, EN60601
Dieletric Strength Test** >2M Ohm, <1m A @2120VDC
Protective Earth Connection*** <0.1 Ohm
*) For digital channels at 550~862 MHz, carriers arc -10 dB lower ralative to analog channels.
**) Test by Hi-Pot tester
***) Test by Voltage Meter applied between the protective earth contact of the mains plug and all
accessible conductive parts.