INSTALLATION MANUAL
SEAS 4030
Line amplier for 32 outlets and 30 dB
Sea Systems AB - Terminalgatan 19A - SE 235 39 Vellinge - Sweden
Tel.: +46 40420250 - www.seasystems.se
- 3/4 -
All specications stated are subject to change without notice.
TECHNICAL SPECIFICATION
Size (H) 230 x (W) 165 x (D) 82 mm
Housing Aluminium Die-casting, Finishing: Black painted
Connectors IN,OUT: 5/8”-24 NEF F-Female to 3/8”-32 UNEF F-Female Adaptor
S-IN: 3/8”-32 UNEF F-Female Connector
Weight 2.32Kg
Electrical Specication
RF Amplication Push-Pull Hybrid Module
Operation Gain (w/ RA) 100 KHz 6.5 dB min.
5 MHz 12.0 dB min.
IN-OUT 27 MHz 16.0 dB min.
(w/ MS-86/18) 47~860 MHz 30.0 dB min.
(w/ E/SM) 47~230 MHz 30.0 dB min.
470~860 MHz 30.0 dB min.
Operation Gain (E/SM IN-OUT) 300~400 MHz 30.0 dB min.
Gain Control 0~ -18.0 dB (adj.)
Slope Control (w/ MS-86/ 18 Module optional) 0~ -18.0 dB (adj.)
Auto Level Control (w/ ALC) +/-5.0 dB (Low Freq. range)
+/-3.5 dB (Low Freq. range)
Noice Figure 47~860 MHz 6.0 dB typ. 8 dB max.
Output Level (Reference) 55/ 550/ 860 MHz 77 NTSC chs. +312 MHz digital*
(97 / 102 / 94 dBu V)
Composite Second Order (CSO) -61 dBc
Composite Triple Beat (CTB) -61 dBc
Cross Modulation (XMOD) -61 dBc
Return Loss 100~300 KHz 6 dB min.
(w/ Jumpers) 300 KHz~27 MHz 14 dB typ. 12 dB min.
47~860 MHz 12 dB typ. 10 dB min.
General Specications
Input Voltage 117/230 VAC +10-15%
Line Frequency 47 ~ 63 Hz
Antenna and Amplier Voltage 15 VDC +/- 5%
Current Antenna Current 300 mA max.
Amplier Current 200 mA max.
Input & Output Test Ports -20 +/- 2 dB F-Female
Input & Output Impedance 75 Ohm
Surge Protection 7000 V for 1.2 x 50 us
Power Supply 117 alt. 230 Vac/ 50/60 Hz
Fuse (For Power Supply) 0.2 A / 250 V (230 Vac)
Power Consumption (Including Powering output to Antenna) 16 W, (25W)
AC Cord Schuko type § 4.8 mm 2 Round pin +
Ground port, 1.5 m cord
Operating Temperature -40 to +60°C
EMC & Safety
EMC EN50083-2, EN61000-3-2/3-3
Safety EN60065, EN60728
Dieletric Strength Test** >2M Ohm, <1m A @2120VDC
Protective Earth Connection*** <0.1 Ohm
*) For digital channels at 550~862 MHz, carriers arc -10 dB lower ralative to analog channels.
**) Test by Hi-Pot tester
***) Test by Voltage Meter applied between the protective earth contact of the mains plug and all accessible
conductive parts.