Seco SYS-D14-MED Quick start guide

SYS-D14-MED
INSTALLATION, USE AND WARNINGS MANUAL
Edition: 11 - 2020

SYS-D14-MED
1Preliminary information....................................................................................................................................... 3
1.1 Device description........................................................................................................................................... 3
1.2 Recipients............................................................................................................................................................ 4
1.3 Warranty.............................................................................................................................................................. 4
2Identification............................................................................................................................................................. 5
2.1 Manufacturer identification......................................................................................................................... 5
2.2 Device identification....................................................................................................................................... 5
2.3 Device identification plate ........................................................................................................................... 5
3Technical specifications ....................................................................................................................................... 6
3.1 SYS-D14-MED device hardware specifications ................................................................................... 6
3.2 Software Specifications ................................................................................................................................. 7
3.3 CE reference directives .................................................................................................................................. 7
3.4 FCC disclaimer................................................................................................................................................... 8
3.5 IC disclaimer....................................................................................................................................................... 8
4Safety devices.........................................................................................................................................................10
4.1 Warnings ...........................................................................................................................................................10
4.2 Safety pictograms affixed on the device and used in the manual............................................12
5Characteristics and components of the device........................................................................................14
5.1 Measurement layout ....................................................................................................................................14
5.2 Components ....................................................................................................................................................15
6Permitted environmental conditions ...........................................................................................................17
6.1 Transport and storage environmental conditions ...........................................................................17
6.2 Operating environmental conditions ....................................................................................................17
7Installation...............................................................................................................................................................19
Information subject to change. Please visit www.seco.com to find the latest version of this manual.
Page.1 of 29

SYS-D14-MED
7.1 Installing the device......................................................................................................................................19
7.2 Versions available..........................................................................................................................................23
8Maintenance...........................................................................................................................................................24
9Waste disposal.......................................................................................................................................................24
10 Electromagnetic Compatibility........................................................................................................................25
Information subject to change. Please visit www.seco.com to find the latest version of this manual. Page.2 of 29

SYS-D14-MED
1 Preliminary information
1.1 Device description
The SYS-D14-MED device is a gateway enclosed in a metal box with a heat sink.
The SYS-D14-MED allows the connection between the LAN (local area network) and the
device to which it is connected via ETH or WiFi, also implementing some cybersecurity
measures (such as antivirus and firewall).
Its purpose is to isolate the LAN (local area network) from the device to which it is connected.
The SYS-D14-MED give to the user the possibility to take log files from the system, analyze
them and upload them to a central repository, helping to create a remote inventory database.
The technology developed by SECO S.p.A. for the SYS-D14-MED device can be used and
applied in various fields, such as:
Digital Signage
Infotainment
Edge
Computing
Robotics
Information subject to change. Please visit www.seco.com to find the latest version of this manual.
Page.3 of 29

SYS-D14-MED
1.2 Recipients
This manual is intended for ordinary people and installers (expert users).
Important! The user must read this manual before start with any kind of operation.
1.3 Warranty
The warranty shall be voided in the event of:
•failure to comply with safety regulations;
•tampering with the device;
•changes to the safety conditions established by the Manufacturer in the device
management software;
•improper use of the device;
•use of the device by untrained and/or unauthorized personnel or failure to respect
duties, as indicated in the manual;
•changes or repairs carried out by the user without written authorization from the
Manufacturer;
•partial or total failure to comply with the instructions;
•defects in the mains power supply (electricity, power supply, etc.);
•poor maintenance;
•use of non-original spare parts;
•exceptional events such as floods, fires (if not triggered by the device).
The complete warranty terms are set out in the sales contract.
Important! The Manufacturer is not liable for improper use of the device.
Information subject to change. Please visit www.seco.com to find the latest version of this manual. Page.4 of 29

SYS-D14-MED
2
Identification
2.1
Manufacturer identification
MANUFACTURER
SECO S.p.A
Via Achille Grandi n°20
Address
52100 Arezzo –Italy
Tel: +39 0575 26979
Fax: +39 0575 350210
2.2
Device identification
Device
SYS-D14-MED
Serial number
YYMMXXXXX
Year of manufacturing
2020
2.3 Device identification plate
The device is equipped with an identification plate located on the side. The plate features the
device identification information to be reported to Seco S.p.A. if necessary.
Caution! It is strictly forbidden to remove the identification plate and/or replace it
with other plates.
Information subject to change. Please visit www.seco.com to find the latest version of this manual. Page.5 of 29

SYS-D14-MED
3 Technical specifications
3.1 SYS-D14-MED device hardware specifications
The table below features the board hardware specifications:
Processor
Memory
Mass Storage
Network connection
USB
Video
Power Supply model
Atom E39xx
Up to 8 GB RAM
Up to 64 GB eMMC
•3x GBE
•Wi-Fi + Bluetooth module on M.2 Key E (INTEL® WIRELESS-
AC 9260, 2230) - Hot Spot e Access Point functionality
•WiFi/BT Antennas PULSE W1043
2x USB 3.0 Host ports, Type A
2x Mini DP connector (only used to set-up the BIOS and
debugging)
Manufacturer: EDAC Power Electronics Co., Ltd.; P/N: EM10681V
(22) (class.1)
Power connector
Jack 3.5mm
RTC Battery
Not rechargeable Lithium battery CR2032
Operating System
Edgehog OS
Linux
Operating temperature
0 °C ÷ +40 °C**
in user environment
Operating humidity in
5 % ÷ 85 %
user environment
Transport / storage room
- 10 °C ÷ + 50 °C
temperature range
Transport / storage
5 % ÷ 90 %
relative humidity range
Atmospheric Pressure
70 kPa ÷ 106 kPa
Altitude
Up to 2000 m
Max Freq. Oscillators
32.678 KHz; 19.2 MHz; 25 MHz; 1.8 GHz
Information subject to change. Please visit www.seco.com to find the latest version of this manual. Page.6 of 29

SYS-D14-MED
IP insulation grade
IP20
Type of installation
Fastening with screws
Attention! **The values indicated refer to the maximum temperature of the
environment of use of the device. It is the customer’s responsibility to verify that the
temperature remains within the admissible range indicated in this manual and, if
necessary, adopt any passive cooling solution together with an application-dependent
cooling system that can ensure that the heat sink temperature will not damage the
device itself and/or the connected mechanical parts.
3.2 Software Specifications
D14XXXYY.BBB software version, where:
-XXX is 000 in standard version and assumes other values in customized versions
-YY is the revision
-BBB is the BIOS version
Software version is released on the SECO website https://www.seco.com and is always updated
and available, even in later versions.
3.3 CE reference directives
SECO S.p.A. places the device on the market, equipping and providing it with:
-CE marking as IT device
-Declaration of Conformity
-User manual
Please also note that the device has been designed according to the following Directives:
-2014/30/EU Electromagnetic Compatibility Directive
-2014/53/EU (RED) (Where applicable, depending on the versions)
-2012/19/EU (WEEE)
-2011/65/EU (RoHS)
the device also meets the requirements of the following standards:
-IEC 62368-1 ed. 3.0
-IEC 60601-1 ed. 3.1
-IEC 60601-1-2 ed. 4
-IEC 60601-1-6:2010 + A1:2013
Information subject to change. Please visit www.seco.com to find the latest version of this manual. Page.7 of 29

SYS-D14-MED
-IEC 62366:2007 + A1:2014
During the IEC 60601-1-2 ESD test it might be happening monitor DP video interface splash. It
is normal because DP video interface will be used only for maintenance and updating.
3.4 FCC disclaimer
This device complies with the FCC Rules and Contains Transmitter Module FCC ID: 2ALZB-D14MED
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
-This device complies with Parr 15 of the FCC Rules. Operation is subject to the
following two conditions.
-(1) this device my not casue harmful interference, and
-(2) this device must accept any interference received, including interference that may
cause undesired operation.
3.5 IC disclaimer
This device complies with the IC Rules and Contains Transmitter Module IC: 22688-
D14MED This Class B digital apparatus complies with Canadian ICES-003.
Operation is subject to the following two conditions: (1) this device may not cause harmful
interference and (2) this device must accept any interference received, including interference that
may cause undesired operation.
CAN ICES-3(B)/NMB-3(B)

SYS-D14-MED
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the
following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage;
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and
compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and
compliance.
Le dispositif rencontre l'exemption des limites courantes d'évaluation dans la section 2.5 de RSS
102 et la conformité à l'exposition de RSS-102 rf, utilisateurs peut obtenir l'information canadienne
sur l'exposition et la conformitéde rf.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter. This equipment should be installed and operated with a minimum distance of 20
centimeters between the radiator and your body.
Cet émetteur ne doit pas être Co-placéou ne fonctionnant en même temps qu'aucune autre
antenne ou émetteur. Cet équipement devrait être installéet actionnéavec une distance
minimum de 20 centimètres entre le radiateur et votre corps.
Information subject to change. Please visit www.seco.com to find the latest version of this manual. Page.9 of 29

SYS-D14-MED
4 Safety devices
4.1 Warnings
Caution! It is the user’s responsibility to apply preventive and protective measures, in
accordance with the legislation of the country of installation and use of the device.
Caution! Only use the power supply, screw for ground connection, power cord and
antennas supplied by the manufacturer.
Caution! Only connect certified peripherals / devices to the device.
Important! Operations on the device must be carried out by specialized and
authorized personnel only.
Caution! Always disconnect the electrical power supply before carrying out any
work on the device.
Caution! Check that the electrical voltage meets the values indicated in this manual
before connecting the device.
Caution! Disconnect the device from any power source before cleaning.
Warning! The enclosure of the device must be cleaned only with a dry cloth.
Caution! Do not pour liquids of any kind on the device. This may cause fires and/or
electric shocks.
Caution! Keep the device away from exposure to moisture values outside the
admissible range indicated in this manual.
Caution! The device must always be fixed to a machine before proceeding with any
type of operation and/or use.
Caution! To avoid the risk of electric shock, this equipment must only be
connected to a supply mains with protective earth.
Information subject to change. Please visit www.seco.com to find the latest version of this manual. Page.10 of 29

SYS-D14-MED
Caution! It is strictly forbidden to modify the appliance in order not to compromise
the characteristics relating to the declared requirements.
Caution! Make sure that any part of the device cannot come in contact with an
unconscious, anaesthetized or incapacitated patient.
Warning! Keep the device at a distance > 20 cm from the human body (SAR
requirements).
Warning! It is strictly forbidden to cover the device during operation.
Warning! It is strictly forbidden for the patient/operator to touch the device
during operation.
Warning! Personnel training is a responsibility of the manufacturer of the device to
which the SYS-D14-MED will be connected.
Warning! Earth connection must be made correctly and the screw must not loosen
during use.
Information subject to change. Please visit www.seco.com to find the latest version of this manual.
Page.11 of 29

SYS-D14-MED
4.2 Safety pictograms affixed on the device and used in the manual
The device and the manual are equipped with symbols, as indicated in the table below:
PICTOGRAM
DESCRIPTION
CE marking
FCC mark
Danger of hot surfaces!
Skin burns in case of contact.
Do not touch with your hands or other body parts
Symbol used to identify important warnings for the safety of the
user and/or of the device
Symbol used to identify important warnings regarding electrical
hazards
Symbol used to indicate the need to consult the instruction
manual before using the equipment
Warning! Read the manual before use
Symbol used to indicate the need to consult the instruction
manual before using the equipment
Protective earth
Information subject to change. Please visit www.seco.com to find the latest version of this manual. Page.12 of 29

SYS-D14-MED
WEEE/RAEE
Indicates the separate collection of electronic and electrical
equipment according to Directive 2012/19/EU.
Symbol on the packaging of the device indicating
the upper and lower
Transportation temperature limit
Symbol on the packaging of the device indicating
that it must be protected from the rain
“This way up” symbol on the packaging of the device
“Fragile, handle with care” symbol on the packaging of the
device
“Use no hooks” symbol on the packaging of the device
Information subject to change. Please visit www.seco.com to find the latest version of this manual.
Page.13 of 29

SYS-D14-MED
5 Characteristics and components of the device
The SYS-D14-MED device is a gateway enclosed in a metal box with a heat sink.
Caution! When running, the device can reach very high temperatures, causing the
danger of burns when in contact with the heat sink.
A back cover with 4 universal fastening points is fastened to the connection frame.
The inserts are the only fastening system to integrate the device on any of the customer’s
machines.
5.1 Measurement layout
Length (A)
162.3 mm
Width (B)
111.8 mm
Height
42.2 mm
Centre-to-centre distance of
147 mm (side A) / 58 mm (side B)
fastening holes (C)
Information subject to change. Please visit www.seco.com to find the latest version of this manual. Page.14 of 29

SYS-D14-MED
6 Permitted environmental conditions
6.1 Transport and storage environmental conditions
The table below features permissible environmental conditions for transport and storage.
Room temperature range
- 10 °C ÷ + 50 °C
Relative humidity range
5 % ÷ 90 %
6.2 Operating environmental conditions
Use of the device and of associated control systems that differ from those listed below is not
permitted.
In particular, the installation and operation environment must not be:
-Exposed to environmental temperatures exceeding 0 °C to + 40 °C;
-Exposed to limit areas of 2,000 m.a.s.l.;
-Exposed to excessive humidity (minimum 5%, maximum 85 %) and rapid changes in
relative humidity (above 0.005 p.u./h);
-Exposed to corrosive fumes;
-Exposed to excessive dust;
-Exposed to abrasive dust;
-Exposed to oil vapours;
-Exposed to powder or gas explosive mixtures;
-Exposed to salt air;
-Exposed to vibrations, impacts or abnormal shocks;
-Exposed to weather conditions beyond the limits permitted or dripping;
-Exposure to unusual transport or storage conditions;
-Exposure to high or rapid thermal changes (above 5K/h);
-Presence of nuclear radiation.
Information subject to change. Please visit www.seco.com to find the latest version of this manual. Page.17 of 29

SYS-D14-MED
Caution! Environmental conditions that differ from those specified may seriously
damage the device. Positioning the device in environments that do not correspond to
those indicated shall render the warranty null and void for the parts to be replaced.
SECO S.p.A. shall not be held liable if these instructions are not complied with.
Information subject to change. Please visit www.seco.com to find the latest version of this manual. Page.18 of 29
Table of contents
Popular Gateway manuals by other brands

ZyXEL Communications
ZyXEL Communications EMG2306-R10A user guide

Alcatel-Lucent
Alcatel-Lucent 500V Series user manual

TRUlink
TRUlink W03 installation guide

National Instruments
National Instruments NI 9796 Getting started guide

Soyal
Soyal AR-321H manual

Pathway connectivity solutions
Pathway connectivity solutions Pathport OCTO 64 Series user guide

Shenzhen Allywll info & tech Co.
Shenzhen Allywll info & tech Co. EIA2000 user manual

Elcomponent
Elcomponent MMTCPBCONV user guide

AudioCodes
AudioCodes MediaPack 114 Configuration guide

Eaton
Eaton LumenSafe installation instructions

ZyXEL Communications
ZyXEL Communications ZyWALL USG Series Application note

Honeywell
Honeywell Notifier 002-467 manual